Beta 601CA User manual

601CA
ISTRUZIONI PER L’USOI
INSTRUCTIONS FOR USEEN
MODE D’EMPLOIF
GEBRAUCHSANWEISUNGD
INSTRUCCIONESE
INSTRUÇÕES DE USOPT
GEBRUIKSAANWIJZINGNL
INSTRUKCJA OBSŁUGIPL
h
ef
±
d
a
b
c
601CA.indd 1 08/09/16 10:54

7
ISTRUZIONI PER L’USO I
INSTRUCTIONS FOR USE EN
DIGITAL TORQUE AND ANGLE GAUGE ITEM 601CA
OPERATION MANUAL AND INSTRUCTIONS FOR THE DIGITAL ANGLE GAUGE MANUFACTURED BY:
BETA UTENSILI S.P.A.
Via A. Volta 18,
20845, Sovico (MB)
ITALY
Original documentation drawn up in ITALIAN.
Store the safety instructions with care and hand them over to the users.
PURPOSE OF USE
The digital gauge can be used for the following purpose:
• measuring the right-hand/left-hand torque or angle on screws and nuts in combination with ratchets
or levers.
The following operations are not permitted:
• the digital gauge must not be used in humid or wet environments, and must not be exposed to heat,
rain or snow
• the maximum capacity of the gauge must not be exceeded
• the digital gauge must not come into contact with chemical and corrosive substances
• the digital gauge must not be used for any applications other than recommended ones.
WORK AREA SAFETY
Do not operate the digital gauge in environments containing potentially explosive atmospheres,
because sparks may be generated, which can ignite the dust or fumes.
Keep children away from the digital gauge.
Do not use the digital gauge near ammable material. .
DIGITAL GAUGE SAFETY
• Before use, check that the digital gauge has not been damaged, and that no parts are worn.
• Do not force the electronic circuit of the digital gauge.
PERSONNEL SAFETY
Stay alert; watch what you are doing. Do not use the digital gauge while tired or under the inuence of
drugs, alcohol, or medication.
BATTERY INSTALLATION/REPLACEMENT
Install or replace the batteries as follows.
• Loosen the four screws of the battery compartment on the back.
IMPORTANT! READ THIS MANUAL THOROUGHLY BEFORE USING THE
DIGITAL GAUGE. FAILURE TO COMPLY WITH THE SAFETY STANDARDS
AND OPERATING INSTRUCTIONS MAY RESULT IN SERIOUS INJURY.
CAUTION
601CA.indd 7 08/09/16 10:54

8
ISTRUZIONI PER L’USO I
INSTRUCTIONS FOR USE EN
• Remove the at batteries, and install the new batteries, paying attention to the polarity (2 AAA batteries).
• Close the battery compartment, and tighten the four screws.
• Remove the batteries, if the digital gauge is not used for an extended period.
• If the battery is at, the battery symbol will be shown on the display.
DIGITAL GAUGE SAFETY
• Do not drop or hit the digital gauge.
• Do not use the digital gauge in humid or wet environments.
• To clean the digital gauge, use a dry cloth. Do not use alcohol or diluents.
• Do not place the digital gauge near magnetic elds.
• Do not modify the digital gauge. Changes may affect operation.
TECHNICAL DATA
KEY TO SYMBOLS
a: LED indicators
b: buzzer
c: digital display
d: start of measurement / menu button (C)
e: unit selection button (U/S)
f: pulsante memoria (M)
f: memory button (M)
+ button
- button
h: battery compartment
DISPLAY
PRECISIONE ANGOLO
TORQUE MEASURING RANGETORQUE
ACCURACY
RESOLUTION
SCALE
SQUARE DRIVE
SELECTABLE UNITS OF MEASUREMENT
PROGRAMMABLE VALUES
STORED VALUES
POWER SUPPLY
OPERATING TEMPERATURE
STORAGE TEMPERATURE
HUMIDITY
WEIGHT
0 ---> 999,0
± 2°
10 ÷ 200 N.m
Clockwise ±3% - Anticlockwise ±4%
0.1°
360° (increment 0.1°)
1/2"
N.m, ft.lb, in.lb, kg.cm, gradi
9
50 max
2 AAA batteries
-10°C ÷ 60°C
-20°C ÷ 70°C
max 90%
260 g
>
>
601CA.indd 8 08/09/16 10:54

9
ISTRUZIONI PER L’USO I
INSTRUCTIONS FOR USE EN
DIGITAL GAUGE OPERATION
This device has been designed to measure right-hand/left-hand torque or angle values on screws and
nuts in combination with ratchets or levers.
Two driving torque measurement modes are available:
PEAK HOLD: the display shows the instant driving torque, the maximum achieved value being shown
at the end.
TRACK: the display only shows the instant driving torque; after the measurement has been completed,
the gauge is ready for a new measurement. When the set value is reached, the LED indicator will turn
on and the buzzer will sound.
• Lay the gauge on a at surface and press the ON button (C). When the symbol 0000 is shown on the
display, wait a few seconds.
NB: Do not move the gauge while setting the required value.
• After the required value has been set, the display will show the previously set torque or angle.
• Press button U/S to change the unit of measurement of the torque or select the value in degrees.
Set the new torque or angle value by pressing buttons and . The new selected value will
automatically be saved. Then press button (M).
• Place the socket with the ratchet on the gauge. Tightening can then be started.
• When 80% of the selected value is reached, the rst green LED will turn on and the buzzer will sound.
• When the maximum set value is reached, the red LED will turn on.
• In the PEAK HOLD mode, press button (M) to store the value of the driving torque or angle
(max. stored values: 50). The number where the value has been stored will blink on the display.
CAUTION: In the PEAK HOLD mode, if the tightening process is interrupted for a few seconds, the
display will blink, showing the value reached upon interruption. When the tightening process is
resumed, the value will be calculated from the value reached before.
• To reset the device and start a new measurement, press button (C).
If the device is not used for approximately 2 minutes, the device will automatically turn off.
SETTING UP MENU
Press button (C) to turn the gauge on.
Keep button (U/S) pressed to enter the conguration menu. Press button (U/S) several times to enter
the menus: PEAK HOLD/TRACK, UNITS OF MEASUREMENT OF DRIVING TORQUE AND ANGLES,
TORQUE MEMORIES, RESETTING TORQUE MEMORIES and TIGHTENING COUNT.
To quit the conguration menu and go back to the preset memories, press button (U/S) again.
PEAK HOLD/TRACK MENU
• During the tightening process, the instant driving torque will be displayed.
• In the PEAK HOLD mode, upon release, the maximum reached value will be displayed.
• In the TRACK mode, upon release, the maximum preset value will be displayed.
The gauge is ready for a new tightening process.
• The TRACK mode does not allow the reached values to be stored.
• In the PEAK mode, the display will show ModE and, in the right bottom corner, a P.
If the display is in the TRACK mode, it will show a T.
• Press buttons and to change the mode.
• To quit the menu, press button (U/S) several times.
TORQUE UNIT OF MEASUREMENT MENU FOR MEASURING ANGLES
• When angles are measured, the device will also measure the simultaneously applied driving torque.
• When the tightening process has been completed, if the device is in the PEAK HOLD mode, the torque
and angle values will be displayed alternatively.
• This menu allows the unit of measurement of the torque to be selected.
CAUTION: When the value of the device is saved, only the angle will be recorded, whereas the torque
will not.
• The display will show A-UI and, on the right, the currently selected unit of measurement.
• Press buttons and to change the unit of measurement.
• To quit the menu, press button (U/S) several times.
>
>
>
>
>
>
601CA.indd 9 08/09/16 10:54

10
ISTRUZIONI PER L’USO I
INSTRUCTIONS FOR USE EN
TORQUE MEMORIES MENU
• This menu provides the values of the measured and stored torque or angle (up to 50 values stored).
• If no values have been stored in the menu, the display will show nonE.
• The display will show the stored torque value for each memory area (n005<--> 20.3°).
• Press buttons and to select the stored values.
• To delete one of the stored values, press button (C) twice in the memory area.
• To quit the menu, press button (U/S) several times.
RESETTING TORQUE MEMORIES MENU
• This function allows all the values stored in the TORQUE MEMORIES menu to be deleted.
• The display will show ClrA
• To delete all the stored values, press button (C): the display will show no?
• To delete all the stored values, press button (C) again. To cancel the operation, press button (U/S).
• To quit the menu, press button (U/S) several times.
TIGHTENING COUNT MENU
• The device will store the torque at a torque value equal to, or higher than, 60% of its maximum capacity.
• The count cannot be reset until the next calibration.
• For example, if the display shows
(n-0 <--> 0160) , it means that 160 torque values have been set.
If it shows (n-1 <--> 2500), it means that 12,500 torque values have been set.
• To quit the menu, press button (U/S) twice.
ERROR MESSAGES
• Er0 > indicates that the gauge has been subjected to a driving torque higher than 110% of the maximum
value.
• Er4 > indicates that the value has not been set correctly. Press button (C) to repeat the operation.
Do not move the gauge while setting it.
• Er5 > indicates that the gauge is not working correctly. Proceed with the RESET.
• Er---> indicates that the gauge was rotated too quickly during a measurement. Press button (C) to repeat
the operation.
• Full > indicates that no data can be stored in the memory because the memory is full. Delete some
of the 50 stored data.
RESET
• The gauge can be reset by removing the batteries.
MAINTENANCE
Maintenance, repair and calibration jobs must be carried out by trained personnel only. For such jobs,
you can contact Beta Utensili S.P.A.’ s repair centre.
DISPOSAL
The crossed-out wheelie bin symbol on the equipment or packaging means that the product should be
collected separately from other types of urban waste at the end of its useful life.
Any user who is going to dispose of this tool can:
• deliver it to an appropriate collection facility for electronic and electrotechnical equipment;
• return it to the dealer upon purchase of a new, equivalent item of equipment;
• in case of a product for professional use only, contact the manufacturer which will arrange for the
product to be properly disposed of.
Proper disposal of this product allows the raw materials contained in it to be reused and prevents da-
mage to the environment and human health.
Illegal disposal of this product is a violation of the provision concerning the disposal of hazardous waste
and will give way to the application of such nes as provided for under current regulations.
>
>
601CA.indd 10 08/09/16 10:54

11
ISTRUZIONI PER L’USO I
INSTRUCTIONS FOR USE EN
WARRANTY
DECLARATION OF CONFORMITY EU
This digital gauge is manufactured and tested in accordance with current EU regulations. It is covered
by a 12-month warranty for professional use or a 24-month warranty for nonprofessional use.
We will repair any breakdowns caused by material or manufacturing defects by xing the defective
pieces or replacing them at our discretion.
Should assistance be required once or several times during the warranty period, the expiry date of this
warranty will remain unchanged.
This warranty will not cover defects due to wear, misuse or breakdowns caused by blows and/or falls.
In addition, this warranty will no longer be valid if any changes are made, or if the digital gauge is
forced or sent to the customer service in pieces.
This warranty explicitly excludes any damage to people and/or things, whether direct or consequential.
We hereby declare, assuming responsibility, that the described product complies with the relevant
provisions of the following Directives:
• Electromagnetic Compatibility Directive (EMC) 2014/30/EU;
• Directive concerning the restriction of the use of certain hazardous substances in electric and
electronic equipment (RoHS) 2011/65/EU.
The Technical Brochure is available at:
BETA UTENSILI S.P.A.
Via A. Volta 18,
20845 Sovico (MB)
ITALY
601CA.indd 11 08/09/16 10:54
Table of contents
Other Beta Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

General
General 50-EB-3 Setup & operation manual

ABB
ABB ScreenMaster RVG200 Battery Replacement Procedure

PCB Piezotronics
PCB Piezotronics 350M88 Installation and operating manual

GE
GE N60 instruction manual

Flow vision
Flow vision FS20-dbEX Instructions for installation and adjustment

Konica Minolta
Konica Minolta RANGE7 brochure