Beta Presto Spectro User manual

INSTRUCTION MANUAL
678910 11 12 13
Y/M M/C
1
2
3
5
99
98
97
95
1
2
3
5
99
98
97
95
1
2
3
5
99
98
97
95
1
2
3
5
99
98
97
95
RES
RES
RES
RES 50% 50%50%
S P E C T R O - D E N S I TO M E T E R
S P E C T R O - D E N S I TO M E T E RS P E C T R O - D E N S I TO M E T E R
PRESTO SPECTRO
PRESTO SPECTROPRESTO SPECTRO
PRESTO
PRESTO
SPECTRO
SPECTROPRESTO
L ‘0’
L ‘0’L ‘0’
L ‘100’
L ‘100’L ‘100’
-a
-a-a
+b
+b+b
-b
-b-b
+a
+a+a
L a b L a b
***
Delta EDelta E
SCTV
NEW!
PRESTO
& PRESTO DELTA E
Low cost, high quality
solution for Density, Dot
Gain, Gray Balance, &
Spot Color Matching. The
Spectro version features
Delta E.
BETACOLOR
XPRESS
DENSITOMETERS
Advanced User Friendly
LED technology. No light
b u l b s t o r e p l a c e ,
ch arger s o r cabl es .
Seven year warranty on
LED’s
BETA QUALITY
CONTROL PRODUCTS
BETAFLEX PRO
FLEXO IMAGE
ANALYZER
Measure HD Flexo Plates,
Masks, Stain Density, Dot
Area, Screen Ruling,
Film, & Offset Plates. 3D
q u a l i t y c o n t r o l D o t
Imaging index.
DIGITAL
MICROMETERS
Precise measurements
of paper, plates, blankets
and packing. Display
0.0005 in. or 0.01mm.
Spring loaded anvil
ass u r e s accuracy.
PRECISION
RULERS
Precise, non-contact
m e a s u r e m e n t o f
distances on films, plates,
dies, & prints. Available
as Electronic Ruler or
Video Ruler.
BETAFOLD
CREASE & FOLD
ANALYZER
Portable, hand-held
analysis of crease
height, width, angles,
and symmetry.
78910 11
Y/M Y/C M/C
1
2
3
5
99
98
97
95
RES 50%50%
50%
SPECTRO
DENSITOMETER
DENSITOMETER
3D
Highlight
Dot
Verification
Metric and Inch
IN
0.0065
FOLD
Beta
FREE 10-DAY TRIAL
707 Commercial Ave. Carlstadt, NJ 07072
Tel: 201-939-2400 [email protected]
The Quality Control Company
www.betascreen.com www.betascreen.net
DOT AREA
DOT AREADOT AREA
DOT GAIN
DOT GAINDOT GAIN
TRAPPING
TRAPPINGTRAPPING
DENSITY
DENSITYDENSITY
GRAY BALANCE
GRAY BALANCEGRAY BALANCE
STOP
GO
Ever Bright
Display
2-Year
Warranty
7-Year on
LED’s
Zero
Maintenance
No Chargers
Traffic
Lights
Y/M Y/C C/M
COLOR MATCH
COLOR MATCHCOLOR MATCH
Precision Easy
Glide Track
Never Touches
Wet Ink

2
Slide the
PRESTO
SPECTRO
forward and
hold until the
measurement
information is
displayed.
The display
will continue
to show
information
even in power
down mode
with no
battery usage.
LED lights will flash when the measurement is GREEN
within tolerance or when out of tolerance.RED
219
ERGONOMIC DESIGN BETA EYE SCAN COLOR BARS
The BETA EYE SCAN CUSTOM GRAY BALANCE COLOR
BAR SYSTEM is designed for faster make ready, precise press
monitoring and quicker turn around using a densitometer for
objective measurements and optical tools for subjective
evaluation. This SEE IT and MEASURE IT system is a precise, cost
effective control system guaranteed to produce the highest quality
printing. The heart of the system is a customized color bar
designed to match the size of your press and numbered ink keys in
exact alignment to the ink keys of the press thereby making faster
and more accurate corrections.
Targets of solid yellow, magenta, cyan, black, and gray balance
appear in every ink zone for ultimate control across the full
width of the sheet. Trapping, dot gain, and resolution targets
are centered for smaller sheets.
CMYK and Gray Balance appear in every ink
zone. 50% and Gray Balance appear every 4th zone
RESOLUTION TARGETS WITH
MICRO DOTS of 1%, 2%, 3%, and
5% minimum printable dot targets
detect press slur and doubling.
Maximum printable dot targets of
95%, 97%, 98% and 99% indicate
press slur, print contrast problems
and/or plate production errors.
Call for more information
99%
98%
97%
95%
2%
1%
3%
5%
The marvel of miniaturization has reduced the size, and
weigh of the PRESTO SPECTRO into a precision color
measuring instrument with unique advanced features that will
increase measurement speed by more than 300%.
TRAFFIC allow the operator total control without the LIGHTS
inevitable errors associated with remembering long strings of
confusing numbers.
BAL
YMCK
25% 75%50%
RES
1% 99%
2% 98%
3% 97%
5% 95%
RES
1% 99%
2% 98%
3% 97%
5% 95%
1% 99%
2% 98%
3% 97%
5% 95%
RES RES
1% 99%
2% 98%
3% 97%
5% 95%
Memorize any color from multiple sources
Y/M Y/C C/M

18
BETA COLOR VIEWER BETA COLOR VIEWER BETA COLOR VIEWER
Mark lll with UV
18
THE WORLD STANDARD FOR VIEWING COLOR
BETA COLOR VIEWER BETA COLOR VIEWER BETA COLOR VIEWER
Mark lll with UV
THE BEST COLOR TOOL SINCE THE DENSITOMETER
Yellow Looks Almost BLACK!BLACK!
High Contrast CMYK Enhancement
Magnifications from 10X-100X
Yellow Looks Almost BLACK!
Getting Started. . . . . . . . . . . . . . . . . . . . . . . 4
Density . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Dot Gain Measurements . . . . . . . . . . . . . . . . . . 5
Balance Mode . . . . . . . . . . . . . . . . . . . . . . . 7
MGM [Magic Color Match] . . . . . . . . . . . . . . . . 8
Trapping . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Color Mode . . . . . . . . . . . . . . . . . . . . . . . . 9
Select Delta E Calculations Formula . . . . . . . . . . . 9
Color Reference Library . . . . . . . . . . . . . . . . . 10
Edit Density & Tolerances . . . . . . . . . . . . . . . . 11
Edit Dot Gain & Tolerances. . . . . . . . . . . . . . . . 12
Edit Gray Balance Tolerance . . . . . . . . . . . . . . . 13
Absolute White Calibration . . . . . . . . . . . . . . . . 13
Density Calibration . . . . . . . . . . . . . . . . . . . . 13
Certification & Reset . . . . . . . . . . . . . . . . . . . 14
Select Delta E Calculation Formula . . . . . . . . . . . 14
Select Color Space . . . . . . . . . . . . . . . . . . . . 14
Select USB Output Format . . . . . . . . . . . . . . . . 14
Optional Color Library Software . . . . . . . . . . . . . 15
3
YMCK
Y/M Y/C C/M
25%
25%25%
75%
75%75%
50%
50%50%
Density Dot Gain Gray Balance
Color Memory
Trapping Color Match
Ver. 2.12
TABLE OF CONTENTS

4
new exclusive with Lab COLORCOLOR REFERENCEREFERENCE LIBRARYLIBRARY
The PRESTO SPECTRO is designed to automatically ZERO
to paper and measure DENSITY and DOT GAIN without
changing programs.
The LED will flash when the measurements are GREEN
within TOLERANCE thereby increasing speed and accuracy
of measurements. TOLERANCES can be changed
according to the quality control requirements.
The LED cautions the operator to look at the display RED
and make corrections accordingly.
Color matching with CMYK is simply done in AUTO DENSITY
mode using the MCM (Magic Color Match) feature or in the
new exclusive with Lab COLOR REFERENCE LIBRARY
Delta E that stores up to 32 colors in 4 separate channels
for fast, accurate AUTO color matching. Ideal for Flexo.
To start, open the AUTO MODE screen and Zero to paper.
Measure DENSITY, DOT GAIN and DOT AREA.
Press KEY D to advance to the other programs.
GETTING STARTED
There are 4 Primary Screens
Automatic Density Balance
Trapping Color
17
Technology For Today’s FlexoTechnology For Today’s FlexoTechnology For Today’s Flexo
Measure
& Control
H D F L E X O (3D Measuring)
& More
.5% Highlights & Better (2D)
BetaFlex PRO
BetaFlex PRO BetaFlex PRO
PLATE & IMAGE
PLATE & IMAGE
ANALYZER
ANALYZER
PLATE & IMAGE
ANALYZER
Better, More Cost Effective Flexo From Superior Image
Analysis In One Affordable Easy-To-Use Device
STOP
GO
TRAFFIC LIGHTS

Precise, Non-contact Measurement of Large and Small Distances
Small details such as barcode lines can be measured within the
eyepiece of the 50x microscope, while the cross hair in the
microscope is used
to locate larger details
VIDEO RULERS
Exact Measurement of Materials and Stretch
BETA VIDEO
& ELECTRONIC RULERS
Data/Image Capture,
Video Micrometer,
CMYK / Spot Color
C o n t r a s t / I m a g e
Enhancement to More
Easily See, Capture
a n d R e c o r d A l l
Information
Optimized for
Extremely
Precise Non-
Contact USB
Measurement
of Films,
Plates, Dies,
and Prints
ELECTRONIC RULERSELECTRONIC RULERSELECTRONIC RULERS
ŸZERO to paper
ŸMeasure the Solid target
ŸMeasure Dot Gain target of
the same color
Select next measurement mode
Note: Status T PRESTO SPECTRO instruments are
delivered with 25%, 50% and 75% Dot Gain target values.
Status E instruments are set at 25%, 40%, and 80%.
These set points can be changed in the Configuration Mode.
5
AUTO Mode DENSITY
In AUTO MODE measure DENSITY, DOT GAIN and DOT AREA.
The unit will automatically ZERO to paper with a DENSITY lower
than 0.15D.
RELATIVE DENSITY MODE with MM (Magic Memory).
ZERO to paper or press and hold Key A to force Zero.
Measure a specific CMYK solid.
To memorize that color press Key A. The display will
show Target Density Updated. Measuring another
Density Target of the same color will cause a or RED
GREEN light according to the TOLERANCE setting.
Note: TOLERANCE Settings are +/- 5.0 dE & changeable
DOT AREA - ZERO to paper, measure solid, then press
Key B and measure DOT AREA.
Press Key C to force a DENSITY measurement and
temporarily disable DOT GAIN and ZERO detection.
YM
CK
DOT GAIN MEASUREMENTS
75%
75%75%
25%
25%25%
100%
100%100%
50%
50%50%

DOT GAIN MEASUREMENTS
Dot gain is inherent in the printing process.
It is composed of two components;
MECHANICAL DOT GAIN is the actual physical growth
of the dot on the substrate and varies according to paper
type, slurring, pressure, ink/water balance, etc.
OPTICAL DOT GAIN is the scattering of light within the
substrate which results in a higher than expected dot gain
when measured with a densitometer using the
Murray/Davies equation.
Slur, Doubling or Ink Water Imbalance result in
unexpected DOT GAIN
6
Mechanical
Dot Gain
Optical
Dot Gain
Total
Dot Gain
+ 6% + 7% 13%
Solid
0.95 D
75% TintSolid
0.95 D1.40 D
Note: When measuring DENSITY targets, the measurement
may occasionally show a false Dot Gain in the display. This
is caused by an abnormally low DENSITY target
erroneously interpreted as a high Dot Gain target.
If this occurs, Zero to paper and measure any questionable
DENSITY target again.
15
OPTIONAL COLOR LIBRARY SOFTWARE
PrestoConnect
Color Library Management Software
The optional
PrestoConnect
Windows software
allows the user to
create, collect, and
manage an unlimited
number of colors in
conjunction with the
new Beta Presto
Spectro portable
spectrodensitometer.
The database organizes the work by Color, Customer, and Job
making it easy for production personnel to use and understand the
system.
Physical samples are measured with the instrument and automatically
written to the database with Lab and Density values, a user-entered color
name, and delta E and density tolerances. A representation of the color is
generated on-screen for confirmation to the operator. Once the sample is
measured the operator has the option to accept the entry, as shown here.
Once the color sample is named and accepted it becomes part of the List
of Colors as shown.

7
0.00
Gray Balance Targets are composed of Yellow, Magenta and
Cyan tints balanced to produce a neutral gray when all the
pre-press conditions are in control.
Making press corrections for slurring, doubling, ink water
imbalance, etc. are fast and easy with ink key adjustments
without stopping the press or wasted paper or downtime.
GRAY BALANCE MODE
Y=40%
M=40%
C=50%
K=50%
For Visual
Comparison
7
14
SELECT USB OUTPUT FORMAT
Select Delta E1976 (not
recommended except for
compatibility)
Select Delta E2000 (the current
international standard)
Select next configuration
Exit
SELECT DELTA E CALCULATION FORMULA
E
Select CIE Lab color space
Select CIE LCh color space
Select next main configuration
function
Exit
SELECT COLOR SPACE
.Measure any Gray Balance Patch 3
without pressing any Keys.
The display arrow will indicate the
greatest difference and direction
followed by the remaining colors.
Select ALL Output format
Select DX Output format
Move to next main configuration function
Exit the configuration mode
CERTIFICATION & RESET
Select the calibration mode
to check the calibration date.
Click the Factory Setting Icon
Key to reset all settings
Balance Tolerance can be changed
up to 7.0 dE.The factory default dE is
5.0 Edit instructions are on page 13.
.Open BALANCE MODE1
2.Zero a 50% Black
tint or an OK sheet
CMY Balance patch
with Key A.
NOTE: The LED’s will flash when measurementsGREEN
are within dE 5.0 or when out of TOLERANCE.RED
1
2
3
BA L50%

Trapping is the result of solid yellow, magenta, and cyan
inks printed in two color combinations to produce red,
green and blue solids.
Trapping efficiency is the ability of the second color to be
accepted or trapped by the first color.
Measure overprint target (for example Red, composed of
Magenta and Yellow)
Matching the color sequence is necessary to match
previous print jobs.
Measure Magenta or Yellow
Measure the second color
Open Trap Screen and
measure Trap Color
See first and second color
sequence and % efficiency
TRAPPING
8 13
Increase highlighted value (L,a,b) Decrease value
Select next value (L,a,b) Return to calibration mode
FLASHING LED’S
ABSOLUTE WHITE CALIBRATION
FLASHING LED’S
DENSITY CALIBRATION
Measure
the white
Lab
plaque
43
2
1
Press Key A - Zero to paper.
Measure solid Cyan, Magenta,
Yellow or Black from a
Calibration Chart
Adjust each Density to agree
with Calibration Chart.
Increase Density
Decrease Density
1.Open the PRESTO Screen
by holding Key A and then
press Key D
2. Press Key B
3. Press Key C 2X

12
6.Press Key A. The Icon will
appear at 3/4 75%.
Press to raise or to lower
target values
3. Press Key C
3X to open DOT FORMULA screen.
4. Select Murray Davies for
standard Dot Gain measurements
on paper or SCTV for Packaging or
special colors. **
1. Open the reset
Screen by holding
Key A and then
press Key D *
*The reset screen can also be opened by
pressing the recessed button on the underside.
** SCTV (Spot Color Tone Value)
Measure a Reference color
with Key A depressed.
Measure print without
pressing any key.
Delta E will display and the
arrow will indicate correction.
9
Auto
E
SPECTRO - Lab DELTA E
Colors can be
configured to use
Lab or Lch in
COLOR SPACE
program.*
SELECT REFERENCE - SAMPLE MEASUREMENTS
L ‘100’
L ‘100’L ‘100’
L ‘0’
L ‘0’L ‘0’
+a
+a+a
-a
-a-a
-b
-b-b
+b
+b+b
Level 1Level 1 - 2.0 dE 2000 the most color critical applications.
- 3.0 dE 2000, color critical applications, e.g. Level 2 Level 2
- 4.5 dE 2000, pleasing process color printingLevel 3Level 3
- 6.0 dE 2000, non critical colorLevel 4Level 4
Level 1 - 2.0 dE 2000 the most color critical applications.
- 3.0 dE 2000, color critical applications, e.g. Level 2
commercial printing
- 4.5 dE 2000, pleasing process color printingLevel 3
- 6.0 dE 2000, non critical colorLevel 4
* See SELECT COLOR SPACE page14
FLASHING LED’S
DELTA E ACCEPTANCE LEVELS
1
3
2
5. Press Key C to open
DOT GAIN MD or SCTV if selected
7. Press Key C to adjust
DOT GAIN REF
8. Press Key C to adjust
+ or - TOLERANCE
Press Key C to continue DOT GAIN adjustments
2. Press Key A to open
COLOR SPACE SCREEN
EDIT DOT GAIN & TOLERANCES

Ink/water Balance
11
EDIT DENSITY & TOLERANCES
Open the PRESTO Screen by
holding Key A and then press
Key D
Press Key A again to open
COLOR SPACE Screen
Press Key D 4X to open the
DENSITY REF screen.
Press Key A to place
on the DENSITY REF screen.
Press KEYS A or B
to adjust CMYK DENSITY
values to match the enclosed
calibration card or to match
shop standards.
Press KEY C to adjust + or -
TOLERANCE values for CMYK
DENSITIES.
Press KEY D to exit.
YMCK
NOTE: The CMYK DENSITY values can be manually
entered, or memorized by direct measurement of a
Calibration Card, or by measuring a live print job.
The +/- TOLERANCE values can only be changed manually.
Activating the reset Icon returns CMYK DENSITY and
TOLERANCE values to factory settings.
10
COLOR REFERENCE LIBRARY
PrestoSpectro will store 32 color References, conveniently
organized in 4 Sections (A,B,C,D), each with 8 Colors.
The AUTO Mode will recognize each of the 8 colors within
the 4 Sections when a sample is measured. For example:
Section A is CMYK plus RGB, Gray Balance or spot color.
Section B is CMYK plus OGV and White ink
Section C and D are any random colors on a print job.
*
*
*
Suggested values
If the selected Volume is empty, SPECTRO Mode will
open as shown here.
Press Key C to open the Library. Volume A is
shown here, B, C, and D are also available with Key C.
Zero to white paper with Key A to erase previous
imeasurements. Measure your REFERENCE to load A001.
1
1
3
2
4
Press Key B to advance to A0002, measure your
REFERENCE to load the value in A0002. Repeat as needed
for A0003, A0004, etc. Press Key D to save Volume A.
AUTO Mode will now open, high-lighting the recognized
REFERENCEin reverse type, displaying the Lab delta E, and
the correction needed.
45
5
The or LED’s will flash to indicate in or out of RED GREEN
TOLERANCE and is adjustable in E TOLERANCE Prog.
The Default setting is dE 5.0 and the range is dE 1.0 - 7.0
23
X
A
B
C
D
Table of contents
Other Beta Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Parkside
Parkside PZM 2 A1 Operation and safety notes

Polimaster
Polimaster PM1403 Operation manual

Sunforest
Sunforest H-100 series user manual

Keeler
Keeler D-KAT Z Instructions for use

Panametrics
Panametrics DigitalFlow XMT868i Service manual

MADDALENA
MADDALENA ElecTo SJ Instructions for installation, use and maintenance