1
ANTELOPE.TECHWEAR
This user manual forms part of the delivery scope of the
ANTELOPE.TECHWEAR.
The instruction manual is aimed at the end user. You must be in
a position to read and understand the information contained in
this instruction manual and the accompanying documents.
This instruction manual must be kept in a well-known, easily ac-
cessible location at all times, and ANTELOPE - part of the Beurer
group - BEURER GmbH must be consulted if any issues or slight-
est doubts arise.
ANTELOPE - part of the Beurer group - BEURER GmbH accept
no liability for damage to persons, animals, property or to the
product itself which arise from improper use, failure to observe
or inadequate observation of the safety criteria contained in this
user manual, or any alterations to the ANTELOPE.TECHWEAR or
the use of unsuitable replacement parts (non-original parts).
The ANTELOPE.TECHWEAR user manual carefully indicates sit-
uations and risks by means of symbols and safety instructions.
IMPORTANT:
Please always refer to this user manual in order to avoid mal-
function and injury.
There are generally four warning levels, identied by the corre-
sponding symbols:
CAUTION Indicates a hazard with a low level of
risk which, if not avoided, could result
in minor or moderate injury.
WARNING Indicates a hazard with a medium lev-
el of risk which, if not avoided, could
result in serious injury and equip-
ment damage.
DANGER Indicates a hazard with a high level of
risk which, if not avoided, will result in
death or serious injury.
NOTE Indicates information helpful in par-
ticular areas or functions.

ANTELOPE - part of the Beurer group - BEURER GmbH
TABLE OF CONTENTS
1. INTRODUCTION .............................................................4
2. INTENDED USE ...............................................................4
3.PURPOSE .........................................................................4
4. INDICATIONS .................................................................5
5. DISCLAIMER ...................................................................5
6. CONTRAINDICATIONS...................................................6
PRECAUTIONS: .................................................................... 6
7. SCOPE OF SUPPLY..........................................................7
7.1 ANTELOPE.SHIRT .......................................................... 7
7.2 ANTELOPE.SHORTS ...................................................... 7
7.3 ANTELOPE.8C-BOOSTER .............................................. 7
7.4 ANTELOPE.TANK-TOP................................................... 8
7.5 ANTELOPE.CALF-GUARDS............................................ 8
7.6 ANTELOPE.2C-BOOSTER .............................................. 8
7.7 ANTELOPE.APP.............................................................. 9
7.8 ANTELOPE.SPRAY.......................................................... 9
7.9 BOOSTER Charging Cable............................................ 9
8. INSTRUCTIONS FOR USE ...............................................10
8.1 Putting on the ANTELOPE.SUIT................................... 10
8.2 Putting on the ANTELOPE.TANK-TOP......................... 10
8.2.1 Connecting the ANTELOPE.TANK-TOP and the
ANTELOPE.2C-BOOSTER .......................................... 11
8.3 Putting on the ANTELOPE.CALF-GUARDS .................. 11
8.3.1 Connecting the ANTELOPE.CALF-GUARDS and the
ANTELOPE.2C-BOOSTER .......................................... 11
8.4 Switching the ANTELOPE.2C-BOOSTER and
ANTELOPE.8C-BOOSTER ON/OFF ..................................... 11
8.5 Connecting the ANTELOPE.2C-BOOSTER and .......... 12
ANTELOPE.8C-BOOSTER to the ANTELOPE.APP via
Bluetooth ...................................................................... 12
8.6 Starting the Stimulation............................................... 12
8.7 Regulating Stimulation................................................. 12
8.7.1 Ending the Stimulation ............................................ 13
8.8 Using the ANTELOPE.2C-BOOSTER and
ANTELOPE.8C-BOOSTER.............................................. 13
8.8.1 Battery status............................................................. 13
8.8.2 Charging the BOOSTER............................................. 13

3
ANTELOPE - part of the Beurer group - BEURER GmbH
9. TROUBLE SHOOTING.....................................................14
10. SAFETY INSTRUCTIONS ...............................................16
11. CARE AND MAINTENANCE..........................................17
11.1 BOOSTER CARE ........................................................... 17
11.2 Washing instructions.................................................. 17
12. DISPOSAL......................................................................17
13. CLAIMS FOR DEFECTS / WARRANTY...........................18
14. LABELS ..........................................................................19
15. TECHNICAL SPECIFICATIONS ......................................20
15.1 ANTELOPE.8C-BOOSTER............................................ 20
15.2 ANTELOPE.2C-BOOSTER............................................ 20
16. COMPANY INFORMATION ..........................................21

4
ANTELOPE - part of the Beurer group - BEURER GmbH
1. INTRODUCTION
ANTELOPE.TECHWEAR uses Electrical Muscle Stimulation (EMS)
for high intensity training units
A condition of safe use is the responsible handling of ANTELOPE.
TECHWEAR. In order to reduce risk this user manual must be
carefully read before use of ANTELOPE.TECHWEAR.
SCOPE OF SUPPLY:
• ANTELOPE.SUIT
ANTELOPE.SHIRT
ANTELOPE.SHORTS
• ANTELOPE.8C-BOOSTER
• ANTELOPE.TANK-TOP
• ANTELOPE.CALF-GUARDS
• ANTELOPE.2C-BOOSTER
• BOOSTER Charging Cable
• ANTELOPE.SPRAY
• ANTELOPE.APP
Available to download on iOS and Andriod.
• IOS: https://itunes.apple.com/de/app/antelope-de/
id1139453110?mt=8
• ANDROID: https://play.google.com/store/apps/details?id=-
club.antelope.app&hl=en
2. INTENDED USE
The ANTELOPE.TECHWEAR is an Over-The-Counter device in-
tended to stimulate healthy muscles in order to improve or facil-
itate muscle performance. This product should be used by adults
only.
The ANTELOPE.TECHWEAR is not intended for adjunctive ther-
apy in the treatment of medical diseases and conditions of any
kind. None of the ANTELOPE.TECHWEAR stimulation programs
are designed for injured or disease aicted muscles. Its use on
such muscles is contraindicated. The stimulation imposed on the
muscles by the ANTELOPE.TECHWEAR programs is denitely not
suitable for rehabilitation and physiotherapy.
Electrical muscle stimulation may therefore be considered a
technique of muscle training and should only be used for this
purpose.
3.PURPOSE
The ANTELOPE.TECHWEAR series stimulates the healthy muscles
to improve performance of human body or general well being. It
is intended to be used by healthy adults only.

5
ANTELOPE - part of the Beurer group - BEURER GmbH
4. INDICATIONS
The ANTELOPE.TECHWEAR is intended to stimulate healthy mus-
cles in order to improve or facilitate muscle performance. It is to
be used by adults only.
Depending on the parameters of the electrical impulses (pulse
frequency, duration of contraction, duration of rest, total session
duration), dierent types of muscle work can be imposed on the
stimulated muscles.
Only use the ANTELOPE.TECHWEAR when you are fully regener-
ated. Follow our workout instructions and also work out without
the ANTELOPE.TECHWEAR regularly.
5. DISCLAIMER
Before using ANTELOPE.TECHWEAR please consult a physi-
cian. The following points should be taken into account. If
one or more of the following apply to you, you must NOT use
ANTELOPE.TECHWEAR for safety reasons:
• You have a cardiac pacemaker or other electrical implant(s)
• You are pregnant
• You have a severe neurological, cardiovascular or tumour
diseases
• You have a serious disease (i.e. fever, infections, inamma-
tions)
• You have muscle ache/soreness
• You have muscle spasms
CAUTION
Do not use the ANTELOPE.TECHWEAR on injured skin or to stim-
ulate the muscles of an aicted limb or joint.
A possible side-eect of unfamiliar and intensive training is
damage to the muscle tissue. This comes with the partial loss
of strength, delayed muscle soreness and a signicant increase
of muscle protein levels (e.g. ceratine kinase levels) found in the
blood. Especially after the rst intense training sessions with the
ANTELOPE.TECHWEAR there is a heightened risk of muscular
damage.
Please follow our instructions carefully to avoid some of the
problems mentioned before.

6
ANTELOPE - part of the Beurer group - BEURER GmbH
6. CONTRAINDICATIONS
Powered muscle stimulators should not be used on patients with
cardiac demand pacemakers.
1. The long-term eects of chronic electrical stimulation are
unknown.
2. Stimulation should not be applied over the neck or mouth.
Severe spasm of the laryngeal and pharyngeal muscles may
occur and the contractions may be strong enough to close
the airway or cause diculty in breathing.
3. Stimulation should not be applied across the chest in that
the introduction of electrical current into the heart may
cause cardiac arrhythmias.
4. Stimulation should not be applied to the head.
5. Stimulation should not be applied over swollen, infected, or
inamed areas or on skin eruptions.
6. Stimulation should not be applied over, or in proximity to,
cancerous lesions.
PRECAUTIONS:
1. Safety of powered muscle stimulators for use during preg-
nancy has not been established.
2. Caution should be used for users with suspected or diag-
nosed heart problems.
3. Caution should be used for users with suspected or diag-
nosed epilepsy.
4. Caution should be used in the presence of the following:
a. When there is a tendency to bleed because of injury;
b. Following recent surgical procedures when muscle contrac-
tion may disrupt the healing process;
c. Over the menstruating or pregnant uterus; and
d. Over areas of the skin which lack normal sensation.
5. Some patients may experience skin irritation or hypersensi-
tivity due to the electrical stimulation or the electrodes.
6. Electrode placement and stimulation settings should be fol-
lowed in accordance with this manual.
7. Powered muscle stimulators should be kept out of the reach
of children.
8. Powered muscle stimulators should be used only with the
leads and electrodes recommended for use by the manufac-
turer.
9. Powered muscle stimulators should not be used while driv-
ing, operating machinery, or during any activity in which in-
voluntary muscle contractions may put the user at undue
risk of injury.
ADVERSE REACTIONS
Skin irritation and burns beneath the electrodes have been
reported with the use of powered muscle stimulators. The fol-
lowing points may indicate serious damage to the muscle tissue
(rhabdomyolysis). If you nd yourself displaying one of these
symptoms please contact a physician:
• Brown urine
• Myalgia (severe muscular pain)
• Extreme swelling of the muscle

7
ANTELOPE - part of the Beurer group - BEURER GmbH
7. SCOPE OF SUPPLY
7.1 ANTELOPE.SHIRT
The fabric of the ANTELOPE.SHIRT consists of 54% polyamide,
36% polypropylene and 10% elastane. The ANTELOPE.SHIRT
includes ten silicone electrodes integrated into the compres-
sion fabric. A baseplate with magnetic buttons attached to
the shirt enables the textile to be connected with the ANTE-
LOPE.8C-BOOSTER.
The ANTELOPE.SHIRT is only intended for training the neck,
upper arm, chest, abdomen and back. In combination with the
ANTELOPE.SHORTS, the ANTELOPE.SHIRT comprises the ANTE-
LOPE.SUIT.
NOTE
The shirt can be connected individually to the ANTE-
LOPE.8C-BOOSTER. A muscle stimulating training without the
ANTELOPE.SHORTS is possible.
7.2 ANTELOPE.SHORTS
The fabric of the ANTELOPE.SHORTS consists of 54% polyamide,
36% polypropylene and 10% elastane. The ANTELOPE.SHORTS
includes six silicone electrodes integrated into the compression
fabric. A connection cable with magnetic buttons hangs from the
ANTELOPE.SHORTS to enables the textile to be connected with
the ANTELOPE.8C-BOOSTER.
The ANTELOPE.SHORTS are only intended for training the ham-
strings and gluteal muscles. In combination with the ANTELOPE.
SHIRT, the ANTELOPE.SHORTS comprise the ANTELOPE.SUIT.
NOTE
The ANTELOPE.SHORTS cannot be used directly without the
shirt. If you only want to use the functions of the shorts, please
put on the complete ANTELOPE.SUIT and choose the relevant
muscle parts in the ANTELOPE. APP.
7.3 ANTELOPE.8C-BOOSTER
The ANTELOPE.8C-BOOSTER is the energy source of the ANTE-
LOPE.SUIT. The 8C-BOOSTER is equipped with a rechargeable
lithium-ion battery.
The stimulation intensity is adjustable by pressing the [+/-] but-
ton on the BOOSTER.
• By pressing [+] you increase the intensity of all channels by
one unit
• By pressing [-] you decrease the intensity of all channels by
one unit
The ANTELOPE.2C-BOOSTER should be charged using the Boost-
er Charging Cable and a standard USB-Charger. The ANTE-
LOPE.8C-BOOSTER is intended only to power and regulate the
electrical stimulation for the ANTELOPE.SUIT.

8
ANTELOPE - part of the Beurer group - BEURER GmbH
7.4 ANTELOPE.TANK-TOP
The fabric of the ANTELOPE.TANK-TOP consists of 54% polyam-
ide, 36% polypropylene and 10% elastane.
The ANTELOPE.TANK-TOP includes four silicone electrodes inte-
grated into the compression fabric. Magnetic buttons attached
to the ANTELOPE.SUIT enables the textile to be connected with
the ANTELOPE.2C-BOOSTER with external cables.
The ANTELOPE.TANK-TOP is only intended for training the abdo-
men and back.
7.5 ANTELOPE.CALF-GUARDS
The fabric of the ANTELOPE.CALF-GUARDS consists of 54% poly-
amide, 36% polypropylene and 10% elastane.
The ANTELOPE.CALF-GUARDS include two silicone electrodes in-
tegrated into the compression fabric. Magnetic buttons attached
to the ANTELOPE.CALF-GUARDS enables the textile to be con-
nected with the ANTELOPE.2C-BOOSTER with external cables
The ANTELOPE.CALF-GUARDS are only intended for training the
calves.
7.6 ANTELOPE.2C-BOOSTER
The ANTELOPE.2C-BOOSTER is the energy source of the AN-
TELOPE.TANK-TOP and ANTELOPE-CALF-GUARDS. The ANTE-
LOPE.2C-BOOSTER is equipped with a rechargeable lithium-ion
battery.
The stimulation intensity is adjustable by pressing the [+/-] but-
ton on the BOOSTER.
• By pressing [+] you increase the intensity of all channels by
one unit
• By pressing [-] you decrease the intensity of all channels by
one unit
The ANTELOPE.2C-BOOSTER should be charged using the Boost-
er Charging Cable and a standard USB-Charger.
The ANTELOPE.2C-BOOSTER is intended only to power and reg-
ulate the electrical stimulation for the ANTELOPE.TANK-TOP and
ANTELOPE.CALF-GUARDS.

9
ANTELOPE - part of the Beurer group - BEURER GmbH
7.7 ANTELOPE.APP
The ANTELOPE.APP acts as an alternative external control sys-
tem to regulate the stimulation of ANTELOPE.TECHWEAR.
Without connecting the ANTELOPE.APP with the ANTELOPE.
BOOSTER it is not possible to begin electrical stimulation.
The following stimulation programs are available via the ANTE-
LOPE.APP:
Endurance Strength Massage
Frequency 40 Hz 60-100 Hz 60 Hz
Impulse Wide 400 µs 350 µs 200 µs
Impulse Typ Contrast 4-second
interval
2,5 seconds
stimulation 1
second ramp
7.8 ANTELOPE.SPRAY
The ANTELOPE.SPRAY is a medically certied liquid that is pur-
posed to improve the consistency of electrical stimulation.
7.9 BOOSTER Charging Cable
The BOOSTER Charging Cable is a micro USB cable which con-
nects to the ANTELOPE.8C-and ANTELOPE.2C-BOOSTER for the
purpose of charging.

10
ANTELOPE - part of the Beurer group - BEURER GmbH
8. INSTRUCTIONS FOR USE
NOTE
We recommend using ANTELOPE.Techwear at least once to max.
twice a week for 20 minutes. Between training sessions, su-
cient time for regeneration should be allowed. Before, during
and after your training you should drink enough water.
8.1 Putting on the ANTELOPE.SUIT
1. Open the three zippers of the ANTELOPE.SHIRT - one on
each side and one in the middle.
2. Put on the shirt and make sure that the electrodes lie at on
your skin without folds or wrinkles.
3. Close the zippers.
4. Put on the ANTELOPE.SHORTS
NOTE
The electrodes must be placed directly onto the skin. Excessi-
ve hair growth or extremely dry skin can aect the stimulation.
Ensure that the electrodes are placed directly on the targeted
muscle.
8.1.1 CONNECTING THE ANTELOPE.SUIT AND THE
ANTELOPE.8C-BOOSTER
DANGER
DO NOT CONNECT THE ANTELOPE.SUIT WITH ANTELOPE.
8C-BOOSTER IF THE BOOSTER IS TURNED ON.
1. On the back of the BOOSTER there is a grid of buttons. Han-
ging from your ANTELOPE.SHORTS there is a connector with
buttons. To connect the two, place the shorts connector on
the lower-most buttons of the BOOSTER.
2. On the side of your ANTELOPE.SHIRT there is another grid of
buttons – this is the baseplate. To connect your shirt to the
BOOSTER, place the BOOSTER on the baseplate.
8.2 Putting on the ANTELOPE.TANK-TOP
1. Open the zippers on front and on each side of the TANK-TOP
2. Put on the TANK-TOP and make sure that the electrodes lie
at on your skin without folds or wrinkles.
3. Close the zippers.
8.2.1 Connecting the ANTELOPE.TANK-TOP and the
ANTELOPE.2C-BOOSTER
DANGER
DO NOT CONNECT THE ANTELOPE.TANK-TOP WITH ANTELOPE.
2C-BOOSTER IF THE BOOSTER IS TURNED ON.
1. Connect the magnetic button ending of the external cables
to the magnetic buttons on the textile. One cable pair should
connect to the front buttons of the textile and the other pair
to the back.
2. Connect the jack plugs of the external cables to the jack plug
input at the bottom of the 2C-BOOSTER.

11
ANTELOPE - part of the Beurer group - BEURER GmbH
NOTE
Be sure to observe which channel (I or II) the external cables are
connected to.
8.3 Putting on the ANTELOPE.CALF-GUARDS
1. Open the zipper on each CALF-GUARD.
2. Put on the CALF-GUARDS and make sure that the electrodes
lie at on your skin without folds or wrinkles.
3. Close the zippers.
8.3.1 Connecting the ANTELOPE.CALF-GUARDS and the AN-
TELOPE.2C-BOOSTER
DANGER
DO NOT CONNECT THE ANTELOPE.CALF-GUARDS WITH
ANTELOPE.2C-BOOSTER IF THE BOOSTER IS TURNED ON.
1. Connect the magnetic button ending of the external cable
to the magnetic buttons on the textile. Only one cable pair
should be used to connect both CALF-GUARDS.
2. Connect the jack plugs of the external cables to the jack plug
input at the bottom of the 2C-BOOSTER.
NOTE
Be sure to observe which channel (I or II) the external cables are
connected to.
8.4 Switching the ANTELOPE.2C-BOOSTER and ANTELOPE.8C-
BOOSTER ON/OFF
• On: Press and hold the [+]-button for three seconds.
• O: Press and hold the [-]-button for three seconds.

12
ANTELOPE - part of the Beurer group - BEURER GmbH
8.5 Connecting the ANTELOPE.2C-BOOSTER and
ANTELOPE.8C-BOOSTER to the ANTELOPE.APP via Bluetooth
NOTE
The ANTELOPE.APP must rst be downloaded via the App Store
or Google Play Store before connecting.
1. Hold the [+] button on the BOOSTER until the blue shining
LED begins to ash. This indicates the BOOSTER is searching
for a compatible device via Bluetooth.
2. Switch the Bluetooth ON from your compatible device
3. Open the ANTELOPE.APP on your device and select the “con-
nect” tab. Your Booster appears on this page. Tap on the
Booster to connect and select the options in the elds to
continue.
NOTE
• After switching on the BOOSTER and before connecting to a
Bluetooth device, the BOOSTER will display a constant green
LED.
• After connecting to the APP via Bluetooth, the LED will
change to a constant blue light.
•
DANGER
If the connection to a Bluetooth device is interrupted for sev-
eral minutes, the BOOSTER DOES NOT switch o automatically.
If a connection between a Bluetooth device and the BOOSTER
is interrupted, immediately disconnect the connection between
BOOSTER and Baseplate. (see 8.7.1)
8.6 Starting the Stimulation
NOTE
Stimulation can only be started from the ANTELOPE.APP. App
and BOOSTER must be connected before.
1. Tap the EMS tab of the ANTELOPE.APP and select a program.
NOTE
The duration of each program can be adjusted.
2. Tap the “start” button at the bottom of the screen to begin
stimulation.
8.7 Regulating Stimulation
• Once the stimulation has been started it can be regulated us-
ing the ANTELOPE.APP and/or directly from the ANTELOPE.
BOOSTER.
• Pressing the [+] on the EMS tab of the ANTELOPE.APP OR on
the BOOSTER, will increase the intensity by one unit on all
channels.
• Pressing the [-] on the EMS tab of the ANTELOPE.APP OR
on the BOOSTER, will reduce the intensity by one unit on all
channels.
DANGER
If stimulation cannot be felt at an intensity of 25%, SWITCH OFF
the BOOSTER and APPLY ANTELOPE. SPRAY directly to the elec-
trodes in the textile. Then restart the ANTELOPE.APP and make

13
ANTELOPE - part of the Beurer group - BEURER GmbH
sure that all intensity levels are set to 0. Once this process is
completed, restart using your ANTELOPE.TECHWEAR according
to the instructions in this manual. (see 8.1).
NOTE
Tapping the muscle groups on the EMS tab of ANTELOPE.APP
will enable individual regulation of specic muscle groups.
8.7.1 Ending the Stimulation
Stimulation can be ended by:
• Pressing the [-] button on the BOOSTER for 3 Seconds.
• Pressing “pause” on the ANTELOPE.APP.
OR
DANGER
• Directly detaching the BOOSTER from the Baseplate or Exter-
nal Cables by pulling with force.
8.8 Using the ANTELOPE.2C-BOOSTER and ANTELOPE.
8C-BOOSTER
NOTE
Please fully charge the ANTELOPE.8C-BOOSTER before initial
use.
8.8.1 Battery status
• Whilst charging the BOOSTER will display a ashing green
LED.
• Once you disconnect the BOOSTER from the charger, the
LED will switch o.
• Once the remaining charge drops under 20%, the BOOSTER
will display a red LED.
8.8.2 Charging the BOOSTER
The BOOSTER takes approximately one hour to fully charge and
it provides approximately 6 sessions.
To avoid damage to your equipment please check the following
requirements before charging the BOOSTER:
• Your charging plug is compatible with your country’s power
socket.
• The nominal voltage in your electrical network ts the re-
quirements of the charging device you are using.

14
ANTELOPE - part of the Beurer group - BEURER GmbH
9. TROUBLE SHOOTING
Problem POSSIBLE CAUSE SOLUTION
Unpleasant
feeling from
Stimulation
Skin condition is dry
• Spray the ANTELOPE.SPRAY directly on the electrodes.
• Drink enough water before, during and after training.
• If necessary, start your training with a light warm-up without stimulation.
DANGER If stimulation cannot be felt at an intensity of 25%, SWITCH OFF the BOOSTER and
APPLY ANTELOPE. SPRAY directly to the electrodes in the textile. Then restart the ANTELOPE.APP
and make sure that all intensity levels are set to 0. Once this process is completed, restart using
your ANTELOPE.TECHWEAR according to the instructions in this manual. (see 8.1).
Stimulation intensity is
too high
• Reduce stimulation intensity
• Stop stimulation
Defect electrode Please contact our Customer Care-Team.
Stimulation is
weak / Cannot
feel Stimulation
Skin Condition is dry
Apply ANTELOPE.SPRAY directly onto the electrodes in the textile.
DANGER If stimulation cannot be felt at an intensity of 25%, SWITCH OFF the BOOSTER and
APPLY ANTELOPE. SPRAY directly to the electrodes in the textile. Then restart the ANTELOPE.APP
and make sure that all intensity levels are set to 0. Once this process is completed, restart using
your ANTELOPE.TECHWEAR according to the instructions in this manual. (see 8.1).
Stimulation Intensity is
too low
Gradually increase stimulation intensity.
DANGER If stimulation cannot be felt at an intensity of 25%, SWITCH OFF the BOOSTER and
APPLY ANTELOPE. SPRAY directly to the electrodes in the textile. Then restart the ANTELOPE.APP
and make sure that all intensity levels are set to 0. Once this process is completed, restart using
your ANTELOPE.TECHWEAR according to the instructions in this manual. (see 8.1).
Defect electrode Please contact our Customer Care-Team.

15
ANTELOPE - part of the Beurer group - BEURER GmbH
Problem POSSIBLE CAUSE SOLUTION
BOOSTER will not
connect to
ANTELOPE.APP
GPS is not activated on
your Android device Activate GPS on your Android device.
Bluetooth connection
was not established via
ANTELOPE.APP
Always establish Bluetooth connection within the ANTELOPE.APP, not via the Bluetooth search on
your device.
Bluetooth compatibility
issues
• Close or reinstall the app in task manager.
• Log in.
• Start the search for your BOOSTER.
• Turn on the BOOSTER.
• Tap once on the displayed BOOSTER.
• If a connection is still not possible, clear the Bluetooth cache and restart the search.
The stimulation
is too strong in
some areas and
too weak in
others
Stimulation of all musc-
le groups has been
increased at once
Deselect the muscle groups from the ANTELOPE.APP and adjust accordingly.
Skin Condition varies
DANGER SWITCH OFF the BOOSTER and APPLY ANTELOPE. SPRAY directly to the electrodes in
the textile. Then restart the ANTELOPE.APP and make sure that all intensity levels are set to 0. Once
this process is completed, restart using your ANTELOPE.TECHWEAR according to the instructions in
this manual. (see 8.1).
Defect electrode Please contact our Customer Care-Team.

16
ANTELOPE - part of the Beurer group - BEURER GmbH
10. SAFETY INSTRUCTIONS
Please follow the safety instructions. Doing otherwise may cause
damage to the device and injury.
• Store the ANTELOPE.TECHWEAR out of the reach of children
in order to prevent them from swallowing parts of the prod-
uct.
• You must not try to replace the battery pack yourself. Opening
the BOOSTER yourself may cause damage.
• Do not touch the electrodes with your ngers while operating
your device.
• Do not use the ANTELOPE.TECHWEAR while driving, operating
machines or manual labour.
• Do not use the ANTELOPE.TECHWEAR in wet conditions such
as heavy rain or snow, while bathing, showering or swimming.
• Never put the BOOSTER or the cables into the washing ma-
chine. The textile including the electrodes is washable by
hand.
• Start at low intensities and slowly increase the power. Do not
deviate from the instructions given in this manual.
• While working out actively with the ANTELOPE.TECHWEAR al-
ways keep your muscles tense or keep moving.

17
ANTELOPE - part of the Beurer group - BEURER GmbH
11. CARE AND MAINTENANCE
11.1 BOOSTER CARE
• Store your BOOSTER in a cool, dry place.
• Charge your BOOSTER at least every six months.
11.2 Washing instructions
The textile consists of 54% polyamide, 36% polypropylene and
10% elastane. It is hand-washable WITHOUT the BOOSTER. To
ensure maximum durability of the ANTELOPE.TECHWEAR please
follow the instructions:
• The textile is washable per hand (max. 30°C ).
• Do not tumble-dry. Hang damp garment from line or bar, in
or out doors.
NOTE
Textile colour may bleed during washing.
12. DISPOSAL
Products with an ANTELOPE logo must not be disposed of with
your household waste. Please dispose it in compliance with
statutory regulations. The equipment cannot be discarded with
household refuse. The equipment must be delivered to a suit-
able collection point for disposal. By doing so, you will be con-
tributing to the safeguarding of natural resources and health.

18
ANTELOPE - part of the Beurer group - BEURER GmbH
13. CLAIMS FOR DEFECTS / WARRANTY
For all ANTELOPE.PRODUCTS we have a warranty period of 24
months according to the legal regulations, towards entrepre-
neurs the period is 12 months.
The electrodes are consumable materials which are subject to
natural wear and tear. In addition to the general life span of ap-
prox. one year, the durability depends strongly from the han-
dling and the right care. For these reasons, no guarantee of du-
rability can be given.
If your electrodes have exceeded their service life of approx. one
year, we will gladly exchange them for a corresponding material
and processing fee. In addition, there is a service charge of 19.90
€ and shipping costs for the outward and return delivery of 19.00
€.* These are valid from the 6th month after purchase. These will
be invoiced to you after completion of the return.
Within the rst 6 months the service at rate and the shipping
costs will be paid by us.
You will not receive guarantees in the legal sense from us, unless
these are
expressly stated in the order conrmation for the respective arti-
cle. Damage that is not covered by the warranty can be repaired
at a charge. The respective costs will be determined and com-
municated.
If you have any further questions regarding claims for defects
and warranty please contact our Customer Care Team.
* all prices listed are gross prices and valid from June 2020
Table of contents
Other Beurer Fitness Equipment manuals

Beurer
Beurer BEURAB01 User manual

Beurer
Beurer EM 59 Heat User manual

Beurer
Beurer EM 32 Reference guide

Beurer
Beurer 8sense PC 100 User manual

Beurer
Beurer EM 38 User manual

Beurer
Beurer EM25 User manual

Beurer
Beurer EM 36 User manual

Beurer
Beurer ANTELOPE Evolution User manual

Beurer
Beurer EM 29 User manual

Beurer
Beurer ANTELOPE.SUIT Origin User manual
Popular Fitness Equipment manuals by other brands

Power Plate
Power Plate pro7 Instructions for use

HOMCOM
HOMCOM A91-194 Assembly & instruction manual

Matrix
Matrix MAGNUM SERIES Quick installation guide

Merrithew Health & Fitness
Merrithew Health & Fitness Stability Chair owner's manual

LeMond
LeMond Revolution quick start guide

Weider
Weider 220 user manual