Now you have chosen your settings you can set up the keypad
• Open the safe door with a valid user or master code
• Press the [CLEAR] key twice, the screen will display ‘PROG’
• Enter the code ‘751019’
• The screen will display the current setup, enter the 6 digits you have
chosen from the setup list i.e. [1][4][1][3][2][!]
• Press the [LOCK] key
• The screen will now display ‘EEEEEE’ enter the date in the format
DD MM YY followed by the [LOCK] key
• The screen will now display ‘EEEEEE’ enter the time in the format
HH MM SS followed by the [LOCK] key
• Enter your user code followed by the [LOCK] key,
the keypad is now set up
NOTE: If you change the code length setting, after entering the date and time, follow the
How to close the safe/change the code’ before closing the safe door
Keypad setup
• With the safe closed press the [LOCK] key
• If screen shows ‘bA-HI’ the batteries are fine
• If screen shows ‘bA-LO’ the batteries are low and need changing
• Open the safe and the battery compartment to change the batteries.
Burton Safes recommend the Duracell brand.
Current supply / Battery change
All hotel safes are supplied with the same factory default
master code. For security reasons it is important that you
change the master code on all of your safes
• Open the safe door with a valid user or master code
• Press the [CLEAR] key twice, the screen will display ‘PROG’
• Enter the current master code (the factory default is 000000’)
• The screen will display ‘NEU’
• Enter a new 6-digit code for your master code;
the screen will display AGAIN’
• Re-enter the new 6-digit code followed by the [LOCK] key to confirm
• The screen will display ‘DONE’
You can customise certain settings of your hotel safe through a programming menu.
Read through the following options to see how you want your safe to function, then follow the
programming instructions.
Digit 1 - Code and beep settings
Digit 2 - The length of your code
3 = 3 digits
4 = 4 digits
5 = 5 digits
6 = 6 digits
NOTE: This should be kept as 4 digits for your hotel guests
Digit 3 - Penalty time length
0 = there will be no penalty lockout time (not recommended)
1 = After 4 incorrect entries there is a penalty time of 15 minutes
2 = After 4 incorrect entries there is a penalty time of 30 minutes
Digit 4 - Master code
2 = off
3=on
NOTE: Burton Safes recommends to keep the master code on
Digit 5 - Audit trail
0 = record safe openings, can close safe door on low power
1= record safe openings and closures, can close safe door on low power
2 = record safe openings, safe door cannot close if power is low
3 = record safe openings and closures, safe door cannot close is power is low
Digit 6 - Mode
1 = hotel mode
Setup options
How to change the master code
NOTE: Do not change your master code to 751019
0 = code will NOT be displayed on the screen. A beep WILL sound when
you press each key
| = code WILL be displayed when typed AND when safe is opened/closed,
a beep WILL sound when you press each key
2 = code WILL be displayed when typed only. A beep WILL sound when
you press each key
3 = code will NOT be displayed on the screen. A beep WILL NOT sound
when you press each key
4 = code WILL be displayed when typed AND when the safe is opened/
closed. A beep WILL NOT sound when you press each key