8
) Avoid operating the product in places where it may be affected by direct
sunlight, water or oil.
(
9
) If the product remains connected to its supply pressure for a long time
while leaving the power turned off, the output pressure may increase to the
level of the supply pressure. For safety, when there is a problem, use the
valve on either the inlet or outlet side. It is recommended to set up the
system for safe operation.
(
10
) If the power is turned off when the unit is up to control pressure, the pres-
sure will be maintained. In this case, if you need to be in an exhaust state,
lower the control pressure first and then turn off the power or use the ex-
haust valve. However, the maintained pressure is not guaranteed to last for
very long.
(
11
) Since the working pressure is supposed to provide the exact control pres-
sure, it is important for the working pressure not to drop below “Control
pressure + Maximum control pressure
×
0.1”.
In particular, if the primary pressure is supplied for a long period of time
with the secondary pressure specified in a range that exceeds 0MPa up to
12% F.S., this will shorten the life span of the product and thus the product
should not be used in this way.
(1
2
) The MEVT Series regulators may oscillate if a leak occurs to the secondary
side piping. When connecting pipes to the regulator, connect them firmly
to prevent leaks. Do not use the regulator for blowing or in any other ap-
plication where the secondary side can be affected by back pressure. If
used in such applications, the regulator will not be able to achieve the spec-
ified pressure. Moreover, a large oscillation noise will be heard and the
product’s durability will be greatly reduced.
(1
3
) In the wiring of the MEVT common terminal stand type and D-Sub con-
nector type, the power grounding line and the signal common line are used
commonly. Therefore, when the MEVT-series product is driven by one
PLC and D/A unit, the correct signals may not be output due to wiring de-
pending on the circuit method of the D/A unit. Before starting the opera-
tion, always contact the PLC manufacturer.
(1
4
) Don’t supply the input signal over maximum control pressure, because an
excessive input signal exerts a bad influence on the deterioration of the
characteristic and also the durability.
(1
5
) Keep the exhaust port (R) open to the air to allow the release of the exhaust
into the air.
(1
6
) When it is maintained the condition where the power is on and the working
pressure isn’t supplied or the condition where the power is on and the input
signal is missing from the control range, the deterioration of the character-
istic and also life occur. Therefore, the product should not be used in this
way.