Electrical Control Interface with AC Crestron CNECI-4A
Leading Specifications of the CNECI-4A
SPECIFICATION DETAILS
Power Requirements 24VDC, load factor of 5.0 watts,
100 -125VAC or 220 - 250VAC, 50 - 60Hz
AC Fuse Type & Rating Slo-Blo, 5 x 20mm, glass; 250V, 160mA
Relay Closure Rating 5A, 1/3HP @ 125 or 250VAC,
10A @ 30VDC
Default Network ID 7F
SIMPL Windows Version 1.30.01 or later1with the add-
ition of smwlib45.exe and smwlib45.txt
CNX Operating System Version 5.01.09x or later
CNX Monitor Version 2.00 or later
CNMS, CNRACK, CNLCOMP Version 3.16.08 or later
Operating System
ST-CP Operating System Version 4.00.29 or later
ST-CP Monitor Version 1.29 or later
VisionTools Pro (VT Pro) Version 1.2.0 or later 1, 2
Enclosure Metal, gray semi-gloss
Enclosure Conduit Knock-outs 3/4 in (1.91 cm) dia., five on three sides
Dimensions & Weight Height: 11.00 in (27.94 cm)
Width: 7.00 in (17.78 cm)
Depth: 2.50 in (6.35 cm)
Weight: 5.40 lb (2.40 kg)
1The latest software versions can be obtained from the Software Downloads page
(Simplwin and Touchpnl Libraries) of Crestron’s website (www.crestron.com).
New users are required to register in order to obtain access to the FTP site.
2VisionTools Pro is required only for SmarTouch programming. Otherwise, it is
not needed.
As of the date of manufacture, the CNECI-4A has been tested and found to comply
with specifications for CE marking.
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) these devices may not cause harmful interference,
and (2) these devices must accept any interference received, including interference
that may cause undesired operation.
Setup
Network Wiring
When calculating the wire gauge for a particular network run, the length of the run
and the power factor of each network unit to be connected must be taken into
consideration. If network units are to be daisy-chained on the run, the power factor
of each network unit to be daisy-chained must be added together to determine the
power factor of the entire chain. If the network unit is a home-run from a Crestron
system power supply network port, the power factor of that network unit is the power
factor of the entire run. The length of the run in feet and the power factor of the run
4 •Electrical Control Interface with AC: CNECI-4A Operations Guide - DOC. 8149