SVA 2xxx/SVA 2xxxF Commissioning instructions
060646-45532 – 05/2023 3
Automatically opening installation example
Fig.1
12
5
3
S G
4
6 7 8 9
11
10
Barrier-free installation situation (example)
(1) Active door leaf with SVA2xxx/2xxxF
(2) Passive door leaf with SVI2xxxF
(3) Panic door fitting
(4) Cable transfer CT, cable spiral CS and if
necessary detachable cable transfer DT
(5) Connecting cable SVP-A1100/2100
(6) Operator inc. control unit (e.g. ED100/250)
(7) Sequential locking control
(8) Door contact TK
(9) Carry bar
(10) SVP-S 4x / 3x (CH) control unit
(11) Access control components
3.1 Parts included
• SVAlock
• Screws required for mounting
• Commissioning instructions SVA2xxx/SVA2xxxF
3.2 Door fittings required
Inner side of the door: Door handle or panic bar
Outer side of the door: Door knob (without function)
Locking pin: 9 mm square for interchangeable fittings
3.3 Technical data
Supply voltage: 24VDC stabilized (+/- 10%)
Power consumption: 0.05A (max. 0.3A)
Bus operation: DCW bus or
CAN bus (ISO11898-3)
“Locked” signal: output switches to GND,
30mA at max. 30 V DC
Tubular
frame locks
Solid door
locks
Rear backset: 15mm 33mm
Distance between
door handle and
locking cylinder:
92mm
for profile
cylinder
94mm
for round
cylinder
72 mm
profile
cylinder
74 mm round
cylinder
Bolt throw: 20mm 20mm
Temperature range: -25°C to +70°C
Relative humidity: up to 95% at 55°C
no condensation
3.4 Variants
(F) = Version with integrated Power Reserve module.
These versions cannot be switched "permanently
open".
Variants for rebated solid doors
Forend: 235 x 20mm, for profile cylinder:
• SVA2271(F): Backset 65mm, DIN left
• SVA2272(F): Backset 65mm, DIN right
• SVA2281(F): Backset 80mm, DIN left
• SVA2282(F): Backset 80mm, DIN right
• SVA2291(F): Backset 100mm, DIN left
• SVA2292(F): Backset 100mm, DIN right
Forend: 235 x 20mm, for round cylinder:
• SVA2371(F): Backset 65mm, DIN left
• SVA2372(F): Backset 65mm, DIN right
• SVA2381(F): Backset 80mm, DIN left
• SVA2382(F): Backset 80mm, DIN right
• SVA2391(F): Backset 100mm, DIN left
• SVA2392(F): Backset 100mm, DIN right
Variants for solid butt doors
Forend: 235 x 24mm, for profile cylinder:
• SVA2277(F): Backset 65mm, DIN left/right
• SVA2287(F): Backset 80mm, DIN left/right
• SVA2297(F): Backset 100mm, DIN left/right
Forend: 235 x 24mm, for round cylinder:
• SVA2377(F): Backset 65mm, DIN left/right
• SVA2387(F): Backset 80mm, DIN left/right
• SVA2397(F): Backset 100mm, DIN left/right
Variants for tubular frame doors
Forend: 270 x 24, for profile cylinder:
• SVA2719(F): Backset 35mm, DIN left/right
• SVA2729(F): Backset 40mm, DIN left/right
• SVA2739(F): Backset 45mm, DIN left/right
Forend: 270 x 24, for round cylinder:
• SVA2819(F): Backset 35mm, DIN left/right
• SVA2829(F): Backset 40mm, DIN left/right
• SVA2839(F): Backset 45mm, DIN left/right
3.5 Integrated Power Reserve module
(only version SVA2xxxF)
The internal Power Reserve module is tested 5 mins
after the power is turned on and then every 48 hrs. If
the test completes with an error, the corresponding
flashing code appears once according to the error
messages (see Chapter 7). The test is then performed
a second time after a further 5 minutes. If this test
is also negative, the flashing code is permanently
displayed.