The P56201 thermostat is designed for controlling heating and air-conditioning
systems.
Important
Before the rst use, make sure to carefully read the instruction manual for the
thermostat, as well as the manual for the boiler or air-conditioning equipment.
Turn o power supply before installing the thermostat!
Installation should be carried out by a qualied person!
Follow applicable standards during installation.
Technical specications:
Switched load: max. 230 V AC; 6 A for resistive load; 2 A for inductive load
Temperature measurement: 0 °C to 40 °C with 0.1 °C resolution; accuracy
±1 °C at 20 °C
Temperature setting: 5 °C to 35 °C in 0.5 °C increments
Temperature dierential setting: 0.2 °C to 2 °C in 0.1 °C increments
Operating temperature: 0 °C to 40 °C
Power supply: 230 V AC/50 Hz
Dimensions: 138 × 88 × 33 mm
Description of the Thermostat – Icons and Buttons (see g. 1)
1 – day number
2 – time
3 – WiFi signal reception
4 – cooling /heating mode
5 – set temperature
6 – menu lock
7 – holiday mode
8 – temporary change of temperature
9 – HOLD mode
10 – current room temperature
11 – programme settings
12 – data and time settings
13 – function selection, conrmation
14 – temporary change of temperature; navigation in the settings
15 – return to main menu
Installing the Thermostat (see g. 2)
Description of the Back of the Thermostat (see g. 3)
1 – contact connection cover
2 – mounting holes
3 – mounting direction
Mobile Application
The thermostat can be controlled using a mobile application for iOS or Android.
Download the EMOS GoSmart app for your device.

14
QR code for downloading the Android app
QR code for downloading the iOS app
Description of Registering and Logging into the Application (see g. 4)
To use the mobile application, you must rst register by tapping the Sign Up button.
Enter your country and e-mail address, check o your consent with the end user
licence agreement and tap Get Verication Code.
Enter the verication code sent to your e-mail.
Then, set the password for your account and tap Done.
Choose whether you want to enable Data Analysis/Personalisation and tap Go
to App.
Connecting the Thermostat to a Wi-Fi network for Control via the
Mobile App (see g. 5)
Tap Add Device in the app and enable location access.
Choose add manually and select Small Home Appliances – Thermostat (Wi-Fi)
or Others – Others (Wi-Fi).
Select a 2.4 GHz Wi-Fi network, enter the password and tap Next.
Check o Conrm that the indicator is ashing rapidly and tap Next.
The chosen thermostat should appear in the app within 2 minutes.
Tap the green arrow on the right; the thermostat will be added into the app.
Then tap the thermostat icon in the app to open the main control menu.
Note:
If the thermostat fails to pair, repeat the process.
5 GHz Wi-Fi networks are not supported.
The thermostat can only be controlled via the app by 1 user at a time. If another
user wants to control the thermostat, the previous user must log out.
Description of the Main Menu of the Mobile App.
Tap the thermostat icon in the app to open the main control menu (see g. 6).
1. Thermostat status (ON/OFF) – Anti-freeze mode, temperature xed to 5 °C
2. Work mode setting (detailed information in the WORK MODES chapter of
this manual)
Automatic
Manual – see HOLD mode
Temporary – see Temporary change mode

15
Boost – see Timed temporary change mode
Holiday – see Holiday mode
3. Schedule (see g. 7)
1 – add a time period
2 – delete a time period
3 – day display
7 days (Mon → Sun)
5+2 days (Mon → Fri + Sat → Sun)
24-hour
Every day can be divided into a maximum of 6 periods.
When in 7 day mode, you can copy the temperature settings from one day into
other days (see g. 8).
Example:
Long-press the Thursday icon; a menu of other days will open. Mark them orange
by tapping them and conrm.
Thursday‘s schedule will copy over to Monday, Tuesday and Wednesday.
4. Setting (see g. 9)
1 – reset the thermostat to factory settings
2 – key lock
3 – correction of ambient temperature (-3 °C to +3 °C in 0.5 °C increments)
4 – heating/cooling system mode
5 – calendar mode (7 days, 5+2, 24 h)
5. Thermostat mode icon
heating
cooling
o
6. Work mode icon
7. Adjust temperature
8. Current room temperature
9. Current set temperature
10. Adjust temperature
11. Network information about the device, change the name in the app,
location information, add an icon to the home screen and other similar
settings
Deleting the Thermostat from the App (see g. 10)
Long-press the thermostat icon, check o the thermostat and tap the dustbin
icon to delete the thermostat.
User Overview/Password Change/App Update
Tap the icon in the bottom right and then the icon in the top right.
This will open a new menu with settings.

16
INSTALLATION
Attention:
Before changing the thermostat, disconnect the heating system from the mains
power in your home. This will prevent potential injury by electric current.
Installing the Thermostat
1. Remove the rear cover of the thermostat (see g. 2).
2. Mark the spots for holes.
3. Drill two holes, carefully insert the plastic wall plugs into them and use two
screws to fasten the rear thermostat cover.
4. Connect the wires to the labelled terminals according to the wiring diagram
found under the cover.
5. Complete the installation by tting the thermostat onto the mounted rear
cover.
Placement of the Thermostat
The placement of the thermostat (transmitter unit) signicantly aects its
functioning.
Choose a location where members of the family spend most of their time,
preferably near an inside wall where air circulates freely, with no direct sunlight.
Do not place the thermostat in the vicinity of heat sources (such as TV sets, radi-
ators, fridges), or close to a door. Failure to comply with these recommendations
will prevent proper control over room temperature.
Wiring Diagram:
Pump/Motorised Valve Connection Diagram
Pump/
valve
Floor Heating Connection Diagram
Connected
device

17
Boiler Connection Diagram
Boiler
• The pre-installed wire coupler will not be connected.
Expansion Valve/Electric Drive Connection Diagram
Connected
device
PUTTING THE DEVICE INTO OPERATION
Setting the Clock, Calendar
Press the button; the values will start ashing.
Use the buttons to set the following values (holding the button down
accelerates the value change):
Day – Month – Year – Hour – Minute.
Conrm the set value by pressing .
To end setting, press the button or wait 30 seconds.
After setting is complete, the current day number will be displayed:
1 – Monday
2 – Tuesday
3 – Wednesday
4 – Thursday
5 – Friday
6 – Saturday
7 – Sunday
WORK MODES
Holiday Mode
Sets a constant temperature for an extended period of time.
Long-press (5 seconds) the button; the time value will start ashing.
Release the button and press it again for 5 seconds.
The icon will appear and the number of days will start ashing.
Repeatedly press the button to set the number of days (from 1 to 99).
Conrm the set number of days by pressing ; the temperature value will
begin ashing.
Repeatedly press the button to set the temperature.
Conrm by pressing ; the icon will appear.

18
If you want to go back and change the temperature for holiday mode, press the
button repeatedly.
You can cancel holiday mode by pressing or .
Temporary Change Mode
Short-term manual change of temperature.
While in Auto mode, use the buttons to change the temperature setting;
the value will be saved automatically.
The icon will appear.
This mode will be automatically cancelled by the rst programmed temperature
change (the time remaining until the change + clock will be alternating in the top
left corner) or it can be cancelled manually by pressing .
OFF Mode
Anti-freeze mode, temperature xed to 5 °C.
While in Auto mode, press the button 2×; a temperature of 5 °C will appear
in the top right corner.
To cancel the mode, press .
Timed Temporary Change Mode
Temporary manual change in temperature for 1 to 9 hours.
While in Auto mode, long-press the button; the time setting will start ashing
in the top left corner.
Use the buttons to set the duration of the temperature change, from 1 to
9 hours, with 1 h resolution.
Conrm by pressing . Then set the temperature of choice using the
buttons.
The remaining set time + the clock will be alternating in the top left corner; you
can cancel the mode prematurely by pressing .
HOLD Mode
Permanent manual temperature change.
While in Auto mode, press the button; the HOLD will appear in the bottom right.
Set the temperature of choice using the buttons; the value will be saved
automatically.
The set temperature will be maintained until HOLD mode is cancelled.
Any programmed temperature change will not be carried out.
To cancel HOLD mode, press .
Heating Programme Setting Mode
Sets temperature over the course of the whole day (6 temperature changes
in the day).
Press the PRG button. The day number will start ashing (1–7 = Monday to
Sunday).
Press repeatedly to select the days of choice.
Dierent each day programme – the number of the selected day ashes
Monday to Friday programme – ashes
Saturday to Sunday programme – ashes
All week programme – ashes
Select your programme of choice and conrm with .

19
The time of the rst temperature change will be ashing; you can set the time
by repeatedly pressing (10 minute increments), then conrm with .
The temperature value will begin ashing; set by repeatedly pressing .
P1 will appear below the set temperature, indicating the 1st temperature
change in the day.
Conrm by pressing . Continue by setting the start of the second temperature
change (P2 will appear under the temperature).
Set the time and temperature by following the same steps as when setting the
1st temperature change.
Continue the process until all 6 temperature changes (P1 to P6) are set.
Factory pre-set times and temperatures are as follows:
Monday to Friday
Temperature change Time Temperature
P1 6:30 20 °C
P2 8:30 16 °C
P3 12:00 16 °C
P4 14:00 16 °C
P5 16:30 21 °C
P6 22:30 7 °C
Saturday to Sunday
Temperature change Time Temperature
P1 7:30 20 °C
P2 9:30 20 °C
P3 11:30 20 °C
P4 13:30 20 °C
P5 16:30 20 °C
P6 22:30 15 °C
Screen Illumination
Pressing any button will illuminate the screen for 15 seconds.
Other Technical Settings
Long-press the button for about 5 seconds.
Repeatedly pressing the button selects from the functions below, values are
adjusted using the buttons.
Connecting the Thermostat to WiFi (COFI)
Long-press the button for about 5 seconds.
Then press and hold the button for 3 seconds.
E2 will appear on the screen and the icon will be ashing.

20
Complete the pairing of the thermostat in the mobile app.
See instructions for Connecting the Thermostat to a WiFi Network for Control
via the Mobile App.
Switching Heating/Cooling Mode
Long-press the button for about 5 seconds.
Press the button once.
Use the buttons to switch to heating (HEAT) or cooling (COOL) mode.
Conrm with .
Setting the Temperature Dierential
The temperature dierential (hysteresis) is the dierence in temperature required
for switching the system on and o. If, for example, you set the temperature in
the heating system to 20 °C and the dierential to 0.2 °C, the thermostat activates
heating as soon as room temperature drops to 19.8 °C and switches heating o
when temperature reaches 20.2 °C.
Long-press the button for about 5 seconds.
Press the button 2× and use the buttons to set the temperature
dierential value (0.2 °C to 2 °C in 0.1 °C increments).
Conrm with .
Ambient Temperature Calibration (CAL)
The temperature sensor in the thermostat is calibrated from production, but
additional calibration can be done to optimise the thermostat further, for instance
by comparing the measured room temperature with a reference thermometer.
Long-press the button for about 5 seconds.
Press the button 3× and use the buttons to set the calibration value
(-3 °C to +3 °C in 0.5 °C increments).
Conrm with .
Time Synchronisation (SYNC)
Long-press the button for about 5 seconds.
Press the button 4× and use the buttons to set:
ON – time will be automatically synchronised with the Wi-Fi network;
OFF – time will not be synchronised with the Wi-Fi network and the time you
set manually will be used.
Conrm with .
Software Version
Long-press the button for about 5 seconds.
Press the button 5×; the software version of the thermostat will be displayed.
Return by pressing .
Resetting the Thermostat (rESE)
Long-press the button for about 5 seconds.
Press the button 6×; rESE will appear on the screen.
Press the PRG button; -- -- will be displayed.
Press the PRG button again; the thermostat‘s menu will be reset and all set
values will be deleted.
Other manuals for P56201
1
Table of contents
Languages:
Other Emos Thermostat manuals
Popular Thermostat manuals by other brands

MICROclimate International
MICROclimate International B1ME user guide

American Standard
American Standard ASYSTAT300C owner's guide

Horstmann
Horstmann ThermoPlus AS2-RF user guide

EBECO
EBECO EB-Therm 55 manual

Secure
Secure SRT323 User and installation instructions

Ocean Breeze
Ocean Breeze QU-800 user manual