READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product must be installed by a competent
person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal service. Using this tting
in any other environments may result in a shortened
working life, for example where there is prolonged
periods of use or higher than normal ambient
temperatures.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
Disconnect the driver from the electrical supply
before ash or high voltage testing.
Do not connect to a circuit which also has inductive
loads connected; switching of inductive loads will
generate spikes which may damage electronic
components within your driver.
This unit is suitable for indoor use only.
This product is designed for permanent connection
to xed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
Make sure that the xings are strong enough to
support the considerable weight of the tting and
hold it rigidly.
The chosen location of your new tting should
allow for the product to be securely mounted (e.g.
to a ceiling joist) and safely connected to the mains
supply (lighting circuit).
When making connections ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This product must be connected to earth
termination.
This product is not intended to be used by children
and persons with sensory, physical and/or mental
impairments that would prevent them from using it
safely.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specied in the current IEE wiring and
building regulations.
OPERATION CHECKS:
Periodic testing should be carried out to ensure
emergency lighting is operating correctly.
Interruption of the supply, causing the tting to be
energised from the battery, should be carried out by
the operation of a local keyswitch or other isolation
device. During this period all ttings should be
examined visually to ensure that they are functioning
correctly. At the end of the test period the supply
shall be restored and all indicator lamps or devices
checked to ensure that the normal supply has been
restored.
DAILY:
Visual inspection of the battery charge LED.
EACH MONTH:
Isolate the power supply for a period sucient to
ensure that each lamp is illuminated. Endorse the
test record form supplied.
ONCE EACH YEAR:
Isolate the power supply and check that the light is
still illuminated after 3 hours. Endorse the test record
form.
Because of the possibility of a failure of the normal
lighting supply occurring shortly after a period of
testing of the emergency lighting system or during
the subsequent recharge period, all full duration
tests shall wherever possible be undertaken
preceding time of low risk to allow for battery
recharge.
NOTE: please keep this instruction booklet and
the test record in a safe place. A re ocer or
other authorised person may want to see your
record of inspection and testing.
EMERGENCY DOWNLIGHT
SPECIFICATION:
EBLF: 0.92
INSTALLATION:
01) Choose the location of your new tting giving
consideration to all of the conditions listed above
and the position of the entry points for the mains
supply cable.
02) Being cautious not to damage the tting,
carefully remove the central metal tray using a
at-head screwdriver to prise open at one end
and then completely detach to allow access to the
internal body of the luminaire.
03) Using the back of the tting as a template, mark
the location of the xing holes on your mounting
surface.
04) If xing to a solid surface, drill holes and insert
suitable plastic plugs.
05) Secure tting in position, ensuring the xings
used are suitable to your installation. Take care
not to over tighten xing screws to prevent
damaging the case.
06) Thread the supply cable through the cable
entry at the centre of the housing. Alternatively,
carefully drill out marked 20mm side entries and
t a gland / nut assembly.
07) Make connections into the terminal block
according to the following colour code:
Neutral – Blue
Earth – Green and Yellow
Live – Brown or Red
08) Connect the emergency driver to the battery and
emergency downlight and write commissioning
date on battery. (See below for diagram).
09) Replace the central metal tray.
10) Restore the power supply and switch on.
11) The emergency downlight will illuminate green
on normal operation, which indicates the tting
is charging. On mains power failure the LED will
illuminate white light continuously for a minimum
of 3 hours.
L’ LN
NEUTRAL
(Blue)
SWITCHED
LIVE (Brown)
PERMANENT
LIVE (Brown)
EARTH
(Green/Yellow)
DRIVER
L
E
N
BATTERY
INPUT 220-240VAC
50/60Hz
1.4W LED