manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eterna
  6. •
  7. Lighting Equipment
  8. •
  9. Eterna PERLED20 User manual

Eterna PERLED20 User manual

Model:
PERLED20
20W LED Perimeter Light
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
874/2012
MODELNO.
PERLED20
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST  DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Disconnect the power and clean the exterior only of
this tting with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
Pack contents:
20W perimeter LED light with
IP rated wiring connection box
and wall mounting bracket
LAMP SPECIFICATIONS:
Lumens total ux 1800 lm
Rated Wattage 20W
Rated luminous ux 1800 lm
Nominal life time of the lamp 25,000 hrs
Colour temperature 3000K
Number of switching cycles
before premature lamp
failure
20,000
Warm-up time up to 60 % of
the full light output Instant full light
Dimmable No
LED strip dimensions (L/W) 270 x 60mm
Nominal beam angle 160°
Rated power 20W
Rated lamp lifetime 25,000 hrs
Lamp power factor 0.85
Lumen maintenance factor at
end of nominal life 70%
Starting time <0.5s
Colour rendering >80
Colour consistency Within 6 step
Macadam ellipse
Rated peak intensity 540cd
Rated beam angle 160°
Voltage 240V
Email: [email protected].uk / [email protected].uk
Visit our website: www.eterna-lighting.co.uk Made in ChinaIssue 1016
READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product must be installed by a competent
person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal service. Using this tting
in any other environments may result in a shortened
working life, for example where there is prolonged
periods of use.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
This unit is suitable for outdoor use.
This product is designed for permanent connection
to xed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
This product is suitable for installation on surfaces
with normal ammability e.g. wood, plasterboard
and masonry.
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
Make sure that the xings are strong enough to
support the considerable weight of the tting and
hold it rigidly.
The lamp must be positioned so that there is at least
0.5m (500mm) between the bulb and any illuminated
surface.
When choosing the location for your new tting,
ensure that the xings will be anchored in a solid
surface e.g. concrete, brick or a joist—do not x
directly onto panelling, cladding, plasterboard etc.
Do not attach to surfaces which are damp, freshly
painted or otherwise electrically conductive (e.g.
metallic surfaces).
When making connections ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This tting is double insulated; do not connect any
part to earth.
This product is not intended to be used by children
and persons with sensory, physical and/or mental
impairments that would prevent them from using it
safely.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specied in the current IEE wiring and
building regulations.
IMPORTANT:
PERLED20 PHOTOCELL - Do not install under
eaves or in a location of frequent shadow that will
prevent the light from switching o when required.
Do not install near other sources of bright light that
will prevent the light from switching on when the
ambient light level falls.
DO NOT CARRY OR LIFT THE PERIMETER
LIGHT BY THE MAINS SUPPLY CABLE!
PLEASE NOTE:
THE PHOTOCELL OPERATES IN NATURAL
LIGHT, THIS SHOULD NOT BE TESTED
USING ARTIFICIAL LIGHT (LED, ENERGY
SAVING LAMP ETC).
LAMP REPLACEMENT:
INSTALLATION:
1. Choose the location for your new light tting
giving considerations to the points listed opposite
and take account of mounting height for area to
be lit.
2. Isolate mains.
3. Mark xing points by using the xing bracket as a
template and drill xing holes, according to your
chosen xing method.
4. Make connections in the IP65 rated connection
box, ensuring the Live, and Neutral polarities are
observed.
5A) Connect blue wire to Neutral terminal marked
(N).
5B) Connect brown wire to live terminal marked (L)
(light to stay on continuously) or connect brown
cable to terminal marked LI (if you want photocell
operation).
6. Restore power and test the luminaire.
Connection Box
Connect BLUE wire to (N)
N
STEP 5A
Connection Box
Connect BROWN wire to (L)
L
STEP 5B
CONTINUOUS LIGHT OPTION
Connection Box
Connect BROWN wire to (LI)
LI
STEP 5B
PHOTOCELL OPTION
Based On Maintenance Factor 0.8
PERLED20 Illuminance Area
0
0m
5m
3m 4.5m
8.5m
7.5 10 15 20 30
Illuminance (Lux)
EXAMPLE FOR MEDIUM TRAFFIC PARKING AREAS
>=10 LUX AVERAGE
Oce buildings • Plants • Sports & Multipurpose Building Complexes
3m
high
4.25m 4.25m
The light source contained in this luminaire
shall only be replaced by the manufacturer,
service agent or a similar qualied person.
CAUTION, RISK OF ELECTRIC SHOCK.
The light source is designed to last the lifetime of the
luminaire.

Other Eterna Lighting Equipment manuals

Eterna GDL50SS Setup guide

Eterna

Eterna GDL50SS Setup guide

Eterna EML3MISO User manual

Eterna

Eterna EML3MISO User manual

Eterna ML5040 User manual

Eterna

Eterna ML5040 User manual

Eterna TUS6NL User manual

Eterna

Eterna TUS6NL User manual

Eterna EMLED3M User manual

Eterna

Eterna EMLED3M User manual

Eterna RDL12 User manual

Eterna

Eterna RDL12 User manual

Eterna VECOEM3M User manual

Eterna

Eterna VECOEM3M User manual

Eterna PLDGEM3 User manual

Eterna

Eterna PLDGEM3 User manual

Eterna LEDREM3 User manual

Eterna

Eterna LEDREM3 User manual

Eterna SELMDDEM3 User manual

Eterna

Eterna SELMDDEM3 User manual

Eterna SEMEM3 User manual

Eterna

Eterna SEMEM3 User manual

Eterna SEEMLED3M User manual

Eterna

Eterna SEEMLED3M User manual

Eterna SAP70MINI User manual

Eterna

Eterna SAP70MINI User manual

Eterna SFLWW9 Setup guide

Eterna

Eterna SFLWW9 Setup guide

Eterna YD630M Setup guide

Eterna

Eterna YD630M Setup guide

Eterna VECOMEM3 User manual

Eterna

Eterna VECOMEM3 User manual

Eterna SL1WH Setup guide

Eterna

Eterna SL1WH Setup guide

Eterna TAB10PIRWH User manual

Eterna

Eterna TAB10PIRWH User manual

Eterna LDLEM3 User manual

Eterna

Eterna LDLEM3 User manual

Eterna D040 Setup guide

Eterna

Eterna D040 Setup guide

Eterna BH60BK Setup guide

Eterna

Eterna BH60BK Setup guide

Eterna MSCSLEDCR User manual

Eterna

Eterna MSCSLEDCR User manual

Eterna EXITBOXM Series Setup guide

Eterna

Eterna EXITBOXM Series Setup guide

Eterna SELDLEM3 User manual

Eterna

Eterna SELDLEM3 User manual

Popular Lighting Equipment manuals by other brands

Emergi-Lite Lux-Ray LED manual

Emergi-Lite

Emergi-Lite Lux-Ray LED manual

Generac Power Systems CTF 10mt owner's manual

Generac Power Systems

Generac Power Systems CTF 10mt owner's manual

MJ LED LIGHTNING MJ-2042CR user manual

MJ LED LIGHTNING

MJ LED LIGHTNING MJ-2042CR user manual

Cree C-LITE C-WP-A-FCT3 Series installation instructions

Cree

Cree C-LITE C-WP-A-FCT3 Series installation instructions

RUTEC VARDAFLEX Select Ultra quick start guide

RUTEC

RUTEC VARDAFLEX Select Ultra quick start guide

Yeelight YLFWD-0013 user manual

Yeelight

Yeelight YLFWD-0013 user manual

American DJ INNO POCKET SPOT User instructions

American DJ

American DJ INNO POCKET SPOT User instructions

Light Sky TX0760 user manual

Light Sky

Light Sky TX0760 user manual

Emos ZR2212 quick start guide

Emos

Emos ZR2212 quick start guide

EuroLite LED Z-2000 user manual

EuroLite

EuroLite LED Z-2000 user manual

WDT GRANUDOS 10-V61 operating instructions

WDT

WDT GRANUDOS 10-V61 operating instructions

ESDDI PS-055 manual

ESDDI

ESDDI PS-055 manual

LIGMAN TANGO 30 installation manual

LIGMAN

LIGMAN TANGO 30 installation manual

Denali D3 quick start guide

Denali

Denali D3 quick start guide

Knightsbridge SPIKEGUBK Installation & maintenance manual

Knightsbridge

Knightsbridge SPIKEGUBK Installation & maintenance manual

Govee H605C user manual

Govee

Govee H605C user manual

Martin RUSH MH 6 Wash CT user manual

Martin

Martin RUSH MH 6 Wash CT user manual

Pixapro StormIII 400 instruction manual

Pixapro

Pixapro StormIII 400 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.