Eterna SQPRISMW User manual

Model:
SQPRISMW / SQOPALMW
CIRPRISMW / CIROPALMW
IP65 LED Utility Fitting With Multi-Function Sensor
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Email: [email protected].uk / [email protected].uk
Visit our website: www.eterna-lighting.co.uk Made in ChinaIssue 1216
Pack contents:
1 x Base
1 x Diuser
874/2012
MODELNO.
Fresh Prince Range
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST  DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Clean this tting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
LED LAMP SPECIFICATIONS:
Luminaire lumens (opal) 1400 lm
Luminaire lumens (prismatic) 1600 lm
Lumens from chip (no diuser) 1750 lm
Rated Wattage 18W
Rated luminous ux (Opal) 1350 lm
Rated luminous ux (Prismatic) 1550 lm
Nominal life time of the lamp 35,000 hrs
Colour temperature 4000K
Number of switching cycles
before premature lamp failure 15,000
Warm-up time up to 60% of the
full light output Instant full light
Dimmable No
LED array dimensions SQUARE (L) 215 x (H) 215mm
LED array dimensions CIRCLE 240mmØ
Nominal beam angle 120°
Rated power 18W
Rated lamp lifetime 35,000 hrs
Lamp power factor >0.9
Lumen maintenance factor at end
of nominal life ≥0.70
Starting time <0.1s
Colour rendering 80 Ra
Colour consistency Within 6 step
Macadam ellipse
Rated peak intensity 520cd
Rated beam angle 120°
Voltage / Frequency 240V~50Hz
Not suitable for accent lighting
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product must be installed by a competent
person in accordance with the current building and
IEE wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal domestic service. Using
this tting in any other environments may result in
a shortened working life, for example where there
is prolonged periods of use or higher than normal
ambient temperatures such as lighting public or
shared spaces or in nursing /care home facilities.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse or lock o
MCB.
Suitable for outdoor use.
This product is suitable for use in living areas,
Bathroom Zone 2 and outsides of zones.
If being tted in a bathroom a 30mA RCD must
be used.
This product is designed for permanent connection
to xed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
This product is suitable for installation on surfaces
with normal ammability e.g. wood, plasterboard
and masonry. It is not suitable for use on highly
ammable surfaces (e.g. polystyrene, textiles).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
The chosen location of your new tting should
allow for the product to be securely mounted (e.g.
to a ceiling joist) and safely connected to the mains
supply (lighting circuit).
When making connections ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This product must be connected to earth
termination.
This product is not intended to be used by children
and persons with sensory, physical and/or mental
impairments that would prevent them from using it
safely.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specied in the current IEE wiring and
building regulations.
INTRODUCTION:
The LED utility light incorporates a microwave
sensing device which continuously scans the
operating zone and immediately switches the
light on when it detects movement in that area.
This means that whenever movement is detected
within the range of the sensor the light will switch
on automatically and illuminate the area you have
selected to light. While there is movement within
range of the unit the light will remain on.
A microwave sensor is an active motion detector
emitting high-frequency electro-magnetic waves at
5.8GHz and receiving their echo. The sensor detects
change in the echo pattern within its detection
zone and the light is then triggered. The wave can
pass through doors, glass and thin walls and will
continually monitor the signal within the detection
area.
LAMP REPLACEMENT:
INSTALLATION:
Isolate mains and lock o.
Choose the location for your new tting according to
the conditions listed opposite.
01) Unscrew gear tray screw and allow the gear tray
to rest on its hinge.
02) Drill holes in the back of your tting for your
xing screws, take care and drill gently to
ensure a clean hole through. Use a drill bit sized
appropriately to your xing screws (not supplied).
03) Using the back of your tting as a template,
mark the position of your xing holes on your
mounting surface.
04) Prepare the holes in your mounting surface as
appropriate for your xings.
05) Pierce the rubber grommet in the back of your
tting making a hole just large enough to make a
tight t around the incoming mains cable.
06) Thread the cable through the grommet and oer
the tting to the ceiling / wall.
07) Secure the tting in place. Note, if protection
against ingress of moisture is required, the heads
of screws must be covered with a silicone or
similar sealant.
08) Check that the grommet is still correctly tted in
the cable entry hole and around the incoming
cable.
09) Make the electrical connections according to the
symbols, adjacent to the connector block, Brown
to live (L) Blue to neutral (N) and earth green &
yellow (E).
10) Set the multi-function sensor. (See
“understanding the controls” instructions on next
page).
11) Oer the diuser and decorative trim onto the
top of the tting and turn clockwise until they are
held securely.
12) Restore the power and switch on.
225cm
60cm240cm
60cm
radius
from tap
ZONE 1
ZONE 0
ZONE 2
ZONE 2
Bathroom Zones Diagram
The light source contained in this luminaire
shall only be replaced by the manufacturer,
service agent or a similar qualied person.
CAUTION, RISK OF ELECTRIC SHOCK.
The light source is designed to last the lifetime of the
luminaire.
MULTIFUNCTION SENSOR
SPECIFICATIONS:
UNDERSTANDING THE CONTROLS:
Refer to the table (g. 1) below.
The sensor is an active motion detector: it emits a
high frequency electromagnetic wave 5.8GHz and
receives its echo. The sensor detects the change
in echo from movement in its detection zone. A
microprocessor then triggers the switch light ON
command. Detection is possible through doors,
panels of glass and thin walls.
DETECTION AREA:
This determines the eective range of the motion
detector and is set up by DIP switches at the sensor,
refer to g. 2 opposite. Note that reducing the
sensitivity will also narrow the detection range.
The following settings are available:
I - Detection Range 100%
II - Detection Range 75%
III - Detection Range 50%
IV - Detection Range 10%
HOLD TIME:
This determines the time the tting remains at
100% level on motion detection and is set with DIP
switches at the sensor, refer to g. 2 opposite. The
walk test setting is useful when installing the tting
to establish correct operation and range.
The following settings are available:
I - Walk test mode 5s
II - 90s
III - 3 minutes
IV - 10 minutes
DAYLIGHT SENSOR:
This setting holds o the 100% light output should
there be sucient daylight and is set using DIP
switches at the sensor, refer to g. 2 opposite.
The following settings are available:
I - Photocell disabled
II - 50 lux twilight operation
III - 15 lux twilight operation
IV - 5 lux darkness operation only
*In daylight setting the lamp(s) will always be on
with motion detected and operate at 100% light
output, even in bright daylight.
CORRIDOR FUNCTION:
This setting determines how long the tting should
operate at 10% output after the hold time has
elapsed and is set by DIP switching at the sensor,
refer to g. 2 opposite.
NOTE: Setting at 0s disables this function; setting
at + ∞leaves it permanently at 10% output until
activated again.
The following settings are available:
I - 0s
II - 30s
III - 10 minutes
IV - + ∞
Detection Area Hold Time Daylight Sensor Corridor Function
1 2 3 4 5 6 7 8
I ON ON 100% I ON ON 5s I ON ON Disable I ON ON 0s
II - ON 75% II - ON 90s II - ON 50Lux II - ON 30s
III ON - 50% III ON - 3min III ON - 15Lux III ON - 10min
IV - - 10% IV - - 10min IV - - 5Lux IV - - +∞
ON
OFF
Model number MLC16C-P
Operating voltage 220-240Vac, 50/60Hz
Output constant current 300mA / 350mA, set via DIP
switch
Output voltage 28-48Vdc
Eciency ≥80%
Power factor ≥0.9
HF system 5.8GHz ± 75MHz, ISM wave
band
Transmitting power <0.5mW
Detection zone max. 16m (D) x 6m (H)
Dectection sensitivity 10% / 50% / 75% / 100%
Hold time 5s / 90s / 3 min / 10 min
Corridor function 0s / 30s / 10 min / Disable
Daylight sensor 5lux / 15lux / 50lux / Disable
Standby dimming level 10% - can be customised
Mounting height 6m Max.
Motion detection 0.5~3m/s
Detection angle 150° (wall installation)
360° (ceiling installation)
Fig 1
Detection
Area
Daylight
Sensor
Hold
Time
Daylight
Sensor
Corridor
function
Fig 2
RED DIRECTIVE Eterna Lighting Ltd
Microwave Occupancy Sensor
Full declaration available at www.eterna-lighting.co.uk

This manual suits for next models

3

Other Eterna Lighting Equipment manuals

Eterna EAC158EM3 Setup guide

Eterna

Eterna EAC158EM3 Setup guide

Eterna SAP70MINI User manual

Eterna

Eterna SAP70MINI User manual

Eterna PLDGEM3 User manual

Eterna

Eterna PLDGEM3 User manual

Eterna ML5040 User manual

Eterna

Eterna ML5040 User manual

Eterna SELDLEM3 User manual

Eterna

Eterna SELDLEM3 User manual

Eterna EXITBOXM Series Setup guide

Eterna

Eterna EXITBOXM Series Setup guide

Eterna YD630M Setup guide

Eterna

Eterna YD630M Setup guide

Eterna SFLWW9 Setup guide

Eterna

Eterna SFLWW9 Setup guide

Eterna LEDREM3 User manual

Eterna

Eterna LEDREM3 User manual

Eterna PERLED20 User manual

Eterna

Eterna PERLED20 User manual

Eterna ELEGAN5EM3 User manual

Eterna

Eterna ELEGAN5EM3 User manual

Eterna TAB10PIRWH User manual

Eterna

Eterna TAB10PIRWH User manual

Eterna MSCSLEDCR User manual

Eterna

Eterna MSCSLEDCR User manual

Eterna TUS6NL User manual

Eterna

Eterna TUS6NL User manual

Eterna SEMEM3 User manual

Eterna

Eterna SEMEM3 User manual

Eterna EMLED3M User manual

Eterna

Eterna EMLED3M User manual

Eterna SL1WH Setup guide

Eterna

Eterna SL1WH Setup guide

Eterna SELMDDEM3 User manual

Eterna

Eterna SELMDDEM3 User manual

Eterna BH60BK Setup guide

Eterna

Eterna BH60BK Setup guide

Eterna RDL12 User manual

Eterna

Eterna RDL12 User manual

Eterna VECOMEM3 User manual

Eterna

Eterna VECOMEM3 User manual

Eterna LDLEM3 User manual

Eterna

Eterna LDLEM3 User manual

Eterna VECOEM3M User manual

Eterna

Eterna VECOEM3M User manual

Eterna EML3MISO User manual

Eterna

Eterna EML3MISO User manual

Popular Lighting Equipment manuals by other brands

Espa FILTERKIT BASE instruction manual

Espa

Espa FILTERKIT BASE instruction manual

Viatek LL03-RGTIPS instructions

Viatek

Viatek LL03-RGTIPS instructions

Hensel C-Light D user manual

Hensel

Hensel C-Light D user manual

Saxby Lighting 1818PIR Instruction leaflet

Saxby Lighting

Saxby Lighting 1818PIR Instruction leaflet

Fulham FHSAC1-UNV-40C Specifications

Fulham

Fulham FHSAC1-UNV-40C Specifications

Prilux Guirnalda E14 instructions

Prilux

Prilux Guirnalda E14 instructions

Philip Payne 250CM manual

Philip Payne

Philip Payne 250CM manual

Ecco ED3974 Series Installation and operation instruction

Ecco

Ecco ED3974 Series Installation and operation instruction

Lithonia Lighting OFL2WG installation instructions

Lithonia Lighting

Lithonia Lighting OFL2WG installation instructions

Commercial Electric H-17M-3PK Use and care guide

Commercial Electric

Commercial Electric H-17M-3PK Use and care guide

Rollei Soluna 200Bi manual

Rollei

Rollei Soluna 200Bi manual

GE StreetDreams Pendant instructions

GE

GE StreetDreams Pendant instructions

Good Earth Lighting SE1295-BRS-02LF1-G manual

Good Earth Lighting

Good Earth Lighting SE1295-BRS-02LF1-G manual

ROTHFELS 1575050 quick start guide

ROTHFELS

ROTHFELS 1575050 quick start guide

JB Systems iMove 7S Operation manual

JB Systems

JB Systems iMove 7S Operation manual

LUCOLED Lucoflex installation guide

LUCOLED

LUCOLED Lucoflex installation guide

BARRON EXITRONIX ILX Series installation instructions

BARRON

BARRON EXITRONIX ILX Series installation instructions

NiteBird SL2 user manual

NiteBird

NiteBird SL2 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.