manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eterna
  6. •
  7. Lighting Equipment
  8. •
  9. Eterna TUS6NL User manual

Eterna TUS6NL User manual

Issue 2015
Model:
TUS6NL / TUS10NL / TUS16NL / TUS20NL
Ultraslim Link Triphosphor Fitting
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
FOR PRODUCT ADVICE:
• T: 01933 673 144
• F: 01933 678 083
• E: [email protected].uk
Visit our website:
www.eterna-lighting.co.uk
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST  DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Clean this light tting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
For breakage information visit:
www.eterna-lighting.co.uk
Pack contents:
1 x Ultraslim uorescent tting
1 x Triphosphor uorescent tube
1 x End socket cover
1 x Link&Light 2M mains lead
2 x “F” clip
2 x “U” clip
1 x Fixing pack
LAMP SPECIFICATIONS: TUS6NL
N64/1
TUS10NL
N64/3
TUS16NL
N64/5
TUS20NL
N64/7
Nominal Wattage 6W 10W 16W 20W
Rated Wattage 6W 10W 16W 20W
Average lifetime hours 10,000 hrs 10,000 hrs 10,000 hrs 10,000 hrs
Nominal useful luminous ux 378 lm 630 lm 1090 lm 1500 lm
Rated luminous ux 378 lm 630 lm 1090 lm 1500 lm
Luminous ecacy (Lm/W) in
50Hz operation 63 63 67 75
Rated lamp Lumen
maintenance
2000hrs: 95%
4000 hrs: 92%
8000 hrs: 90%
2000hrs: 95%
4000 hrs: 92%
8000 hrs: 90%
2000hrs: 95%
4000 hrs: 92%
8000 hrs: 90%
2000hrs: 95%
4000 hrs: 92%
8000 hrs: 90%
Rated survival factors
2000hrs: 99%
4000 hrs: 97%
8000 hrs: 90%
2000hrs: 99%
4000 hrs: 97%
8000 hrs: 90%
2000hrs: 99%
4000 hrs: 97%
8000 hrs: 90%
2000hrs: 99%
4000 hrs: 97%
8000 hrs: 90%
Lamp dimensions (mm) 220mm 341mm 468mm 567mm
Cap type T4 T4 T4 T4
Lamp Mercury content to an
accuracy of 0.1mg <2mg <2mg <2.5mg <2.5mg
Colour rendering index Ra 83.2 82.9 81.8 82.5
Colour temperature 3400K 3400K 3400K 3400K
Ambient temperature required
to achieve maximum luminous
ux
25°C 25°C 25°C 25°C
Dimmable No No No No
Ballast EEI A2 A2 A2 A2
Made in China
READ THIS FIRST:
Check the pack and make sure you have all of the parts
listed on the front of this booklet. If not, contact the
outlet where you bought this product.
This product contains glass, care must be taken when
assembling, tting or handling to prevent personal
injury or damage to the product.
This light tting must be installed by a competent
person in accordance with the Building Regulations
making reference to the current edition of the IEE Wiring
Regulations (BS7671). The Building Regulations may be
obtained from HMSO or viewed and downloaded from
www.communities.gov.uk following the link for Building
Regulations.
As the buyer, installer and/or user of this product it is
your own responsibility to ensure that this tting is t
for the purpose for which you have intended it. Eterna
Lighting cannot accept any liability for loss, damage or
premature failure resulting from inappropriate use.
This product is designed and constructed according to
the principles of the appropriate British Standard and
is intended for normal domestic service. Use of this
tting in any other environment, for example where
prolonged periods of use may be expected and/or
higher than normal ambient temperatures, may result in
a foreshortened working life.
The lamps (tubes) supplied with this tting are
consumable parts and therefore may be outside of any
warranty oered.
Disconnect the tting from the electrical supply before
ash or high voltage testing.
Suitable for indoor use only.
This product is suitable for use in living areas, and
Bathroom dry (Outside) Zones only (see diagram below
and current IEE Wiring Regulations for details). It is
not suitable for Bathroom Zones 0, 1, 2, or other areas
where contact with moisture is likely. If being tted in a
bathroom a 30mA RCD must be used.
This product is suitable for installation on surfaces with
normal ammability (indicated by the “F” in a triangle)
e.g. wood, plasterboard, masonry. It is not suitable for
use on highly ammable surfaces (e.g. polystyrene,
textiles).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface such
as pipes or cables.
The chosen location of your new tting should allow
for the product to be securely mounted and safely
connected to the mains supply.
Do not attach to surfaces which are damp, freshly
painted or otherwise electrically conductive (e.g.
metallic surfaces).
If the location of your new tting requires the provision
of a new electrical supply, the supply must conform
with the requirements of the Building Regulations
making reference to the current edition of the IEE Wiring
Regulations (BS7671).
This product is designed for permanent connection to
xed wiring: this should be either a suitable lighting
circuit (protected with a 5 or 6 Amp MCB or fuse) or a
fused spur (with a 3 Amp fuse) via a fused connection
unit. We recommend that the supply incorporates a
switch for ease of operation.
The cores in the mains lead are coloured in accordance
with the following code:
Live - Brown or Red
Neutral - Blue or Black
When making connections, ensure that the terminals are
tightened securely and that no strands of wire protrude.
Check that the terminals are tightened onto the bared
conductors and not onto any insulation. Wrap loose
terminal blocks well with insulating tape.
This product is double insulated; do not connect either
the Blue wire or the Brown wire to the Earth terminal.
IMPORTANT: Always switch o at the socket and
remove the plug before changing the lamp.
A maximum of six ttings may be linked together in one
chain.
You are advised at every stage of your installation to
double-check any electrical connections you have made.
After you have completed your installation there are
electrical tests that should be carried out: these tests are
specied in the Wiring Regulations (BS7671) referred to
in the Building Regulations.
LAMP REPLACEMENT:
01) Switch o the electricity at the mains.
02) Remove the diuser (diuser model) or tube
retaining brackets (non-diused model).
03) Rotate the tube through 90° at both ends and pull it
out of the gap.
04) Fit only Eterna® branded tubes of the same type
and size.
05) Re-t the diuser or tube retaining brackets.
REPLACEMENT LAMP TYPE:
TUS6NL requires 1 x 6W G5 T4 220mm uorescent tube
3400K (N64/1). Fitting is rated at 6W max.
TUS10NL requires 1 x 10W G5 T4 341mm uorescent
tube 3400K (N64/3). Fitting is rated at 10W max.
TUS16NL requires 1 x 16W G5 T4 468mm uorescent
tube 3400K (N64/5). Fitting is rated at 16W max.
TUS20NL requires 1 x 20W G5 T4 567mm uorescent
tube 3400K (N64/7). Fitting is rated at 20W max.
INSTALLATION:
01) When positioning the tting, make sure there is a
gap of at least 10mm between the lamp and any
adjacent surface. See below:
02) Select the type of brackets you need to use and
mark o the xing points. If xing to a shelf or under
a cupboard, check the screw size required and screw
into place. (See above for clip positions).
03) If xing directly to the wall, drill holes using a
suitable drill bit to a depth of 30mm and insert wall
plugs.
04) Secure the selected brackets in place using the
screws supplied.
05) Attach the tting to the clips.
06) Connect the mains lead or link lead to the socket on
your tting.
07) Restore the power supply and switch on.
WARNING:
The leads supplied with your light tting and the
sockets incorporated in your tting are designed to give
protection against any possible electrical hazard. The
mains lead is terminated in a socket marked NLS and
this lead should be used to supply mains to your tting
or chain of ttings. Under no circumstances should you
attempt to adapt the link lead to supply power to the
opposite end of your tting as this will leave live pins
exposed at the mains input end of the tting. Altering
or adapting any of the leads, other than shortening the
mains supply lead, will invalidate your guarantee and
could present a severe electrical shock hazard.
HOW TO LINK MULTIPLE FITTINGS
TOGETHER:
OPTION 1 (REFER TO FIG. 1 ABOVE)
The light ttings can be butted together to form a line
of up to a maximum of 6 ttings. Simply remove the
connector caps and push the ttings together. Use the
mains lead cable to connect the rst tting and the
mains via a spur or junction box (not supplied).
OPTION 2 (REFER TO FIG. 2 ABOVE)
Connect link leads between each tting and once all
lights have been connected, connect the mains lead to
the mains via a spur or junction box (not supplied).
225cm
60cm240cm
60cm
radius
from tap
ZONE 1
ZONE 0
ZONE 2
ZONE 2
Bathroom Zones Diagram
10mm Gap
End View
End View
10mm Gap
“U Clip” “F Clip”
Mains via a spur
or junction box
Mains via a spur
or junction box
Eterna Link Leads Available:
NL1WH / NL50WH / NL25WH
Mains via a spur
or junction box Eterna Transformer Available: D034
Fig 2
Fig 1
874/2012
A
MODELNO.
TUS Range
Code kwh /
1000h
N64/1 7.80
N64/3 12.67
N64/5 19.74
N64/7 24.31
A
Replacement lamps available: N64/1, N64/3, N64/5, N64/7

This manual suits for next models

3

Other Eterna Lighting Equipment manuals

Eterna SELMDDEM3 User manual

Eterna

Eterna SELMDDEM3 User manual

Eterna SEEMLED3M User manual

Eterna

Eterna SEEMLED3M User manual

Eterna SELDLEM3 User manual

Eterna

Eterna SELDLEM3 User manual

Eterna ML5040 User manual

Eterna

Eterna ML5040 User manual

Eterna BH60BK Setup guide

Eterna

Eterna BH60BK Setup guide

Eterna LDLEM3 User manual

Eterna

Eterna LDLEM3 User manual

Eterna LEDREM3 User manual

Eterna

Eterna LEDREM3 User manual

Eterna YD630M Setup guide

Eterna

Eterna YD630M Setup guide

Eterna EXITBOXM Series Setup guide

Eterna

Eterna EXITBOXM Series Setup guide

Eterna SQPRISMW User manual

Eterna

Eterna SQPRISMW User manual

Eterna TAB10PIRWH User manual

Eterna

Eterna TAB10PIRWH User manual

Eterna SL1WH Setup guide

Eterna

Eterna SL1WH Setup guide

Eterna GDL50SS Setup guide

Eterna

Eterna GDL50SS Setup guide

Eterna D087 Setup guide

Eterna

Eterna D087 Setup guide

Eterna RDL12 User manual

Eterna

Eterna RDL12 User manual

Eterna SEMEM3 User manual

Eterna

Eterna SEMEM3 User manual

Eterna SFLWW9 Setup guide

Eterna

Eterna SFLWW9 Setup guide

Eterna D040 Setup guide

Eterna

Eterna D040 Setup guide

Eterna EML3MISO User manual

Eterna

Eterna EML3MISO User manual

Eterna ELEGAN5EM3 User manual

Eterna

Eterna ELEGAN5EM3 User manual

Eterna MSCSLEDCR User manual

Eterna

Eterna MSCSLEDCR User manual

Eterna EMLED3M User manual

Eterna

Eterna EMLED3M User manual

Eterna SAP70MINI User manual

Eterna

Eterna SAP70MINI User manual

Eterna LED4WH Setup guide

Eterna

Eterna LED4WH Setup guide

Popular Lighting Equipment manuals by other brands

Lightolier EG2-12 Specification sheet

Lightolier

Lightolier EG2-12 Specification sheet

LIGMAN QUANTUM 2 installation manual

LIGMAN

LIGMAN QUANTUM 2 installation manual

Lumineux Redbrook 421065 quick start guide

Lumineux

Lumineux Redbrook 421065 quick start guide

Jands Event 4 Technical manual

Jands

Jands Event 4 Technical manual

Rompa 17630 manual

Rompa

Rompa 17630 manual

Aervoe 1154 operating instructions

Aervoe

Aervoe 1154 operating instructions

Ferplast 45 user manual

Ferplast

Ferplast 45 user manual

driade BALANCE quick start guide

driade

driade BALANCE quick start guide

Rollei Lumen Solo manual

Rollei

Rollei Lumen Solo manual

Patriot Lighting FL1128-BR4-19LF0-T instruction sheet

Patriot Lighting

Patriot Lighting FL1128-BR4-19LF0-T instruction sheet

Robus RTW0130RG-24 manual

Robus

Robus RTW0130RG-24 manual

WAC Lighting GATE 12V installation instructions

WAC Lighting

WAC Lighting GATE 12V installation instructions

TowMate Powerlink PLC50 Series Guide to operations

TowMate

TowMate Powerlink PLC50 Series Guide to operations

mitoredlight Original 2.0 Series user manual

mitoredlight

mitoredlight Original 2.0 Series user manual

Emos P3321 instruction manual

Emos

Emos P3321 instruction manual

Life 39.9PF2023C quick start guide

Life

Life 39.9PF2023C quick start guide

Arize Element L2000 installation guide

Arize

Arize Element L2000 installation guide

Pentair IntelliPool user manual

Pentair

Pentair IntelliPool user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.