Safetymarkings:
Read thisfirst:
>Ifinanydoubt, consultaqualified electrician.
>Suitable for indoor useonly.
>Suitable for fixing on anormally flammable surface.
>Before making fixing hole(s),check thatthere are no obstructionshidden beneaththe mounting
surfacesuchas pipes or cables.
>If the location of your newfitting requiresthe provision ofanewelectrical supply, thesupplymust
conform withthe requirements ofthe latestedition ofthe IEE wiring regulations.
>Makeconnections tothe electricalsupply in accordancewiththe following code:
Live-Brownor Red
Neutral -Blue or Black
>Thisproduct isdesigned for permanentconnection tofixed wiring:thisshould be either asuitable
lighting circuit (protected witha5or 6AmpMCBor fuse)or afused spur (witha3Ampfuse)via
afused connection unit. Werecommend thatthe supplyincorporatesaswitchfor easeof
operation.
>This fitting is double insulated, do notconnect any parttoearth.
>Ensure that the minimumdistancefromthe lighttoanyflammable surfaceis atleast 40mm.
>Ifinanydoubt, consultaqualified electrician.
Installation:
1) Turn off the electricalsupplyand removetheappropriatecircuitfuse.
2) Choosethe locationofyour pygmylightsothat themovementofthe switchiswithinthe
rangesshowninthe diagramopposite.
3) Ensure thatthere isatleast 40mmbetween the fittingand anyoverhanging or
horizontalsurface.See diagramopposite.
4) Secure thefittinginplaceusingscrewsappropriatetothe mountingsurface.
5) Usingcableclipsfor 2x0.75mm²flattwinflex,secure the cabletothe mounting
surfacechoosingaroutewhichpreventsthecablefromfoulingthe movement of
whatever youhaveplanned toactuatethe switch.
6) Usingan Eterna ®Linklead (notsupplied ),makeyour connection tothemains
supply.See abovefor wiringcolour code.
7) Fitthe 15 Watt pygmylampsupplied.
8) Restore the power and switchon.
40mm
ON—1.5mm
OFF—5.0mm