FAAC S800H ENC User manual

S800H ENC
S800H ENC


3 532096 Rev. BS800H ENC
Translation of the original instructions
ENGLISH
1) ATTENTION! To ensure the safety of people, it is important that you read
all the following instructions. Incorrect installation or incorrect use of
the product could cause serious harm to people.
2) Carefully read and follow the instructions before beginning to install the
product.
3) Do not leave packing materials (plastic, polystyrene, etc.) within
reach of children as such materials are potential sources of danger.
4) Store these instructions for future reference.
5) This product was designed and built strictly for the use indicated in this
documentation. Any other use, not expressly indicated here, could
compromise the good condition/operation of the product and/or be
a source of danger.
6) FAAC declines all liability caused by improper use or use other than
that for which the automated system was intended.
7) Do not install the equipment in an explosive atmosphere: the presence
of inflammable gas or fumes is a serious danger to safety.
8) The mechanical parts must conform to the provisions of Standards EN
12604 and EN 12605.
For non-EU countries, to obtain an adequate level of safety, the
Standards mentioned above must be observed, in addition to national
legal regulations.
9) FAAC is not responsible for failure to observe Good Technique in
the construction of the closing elements to be motorised, or for any
deformation that may occur during use.
10) The installation must conform to Standards EN 12453 and EN 12445.
For non-EU countries, to obtain an adequate level of safety, the
Standards mentioned above must be observed, in addition to national
legal regulations.
11) Before attempting any job on the system, cut out electrical power .
12) The mains power supply of the automated system must be fitted with
an all-pole switch with contact opening distance of 3mm or greater.
Use of a 6A thermal breaker with all-pole circuit break is recommended.
13) Make sure that a differential switch with threshold of 0.03 A is fitted
upstream of the system.
14) Make sure that the earthing system is perfectly constructed, and
connect metal parts of the means of the closure to it.
15) The automated system is supplied with an intrinsic anti-crushing safety
device consisting of a torque control. Nevertheless, its tripping threshold
must be checked as specified in the Standards indicated at point 10.
16) The safety devices (EN 12978 standard) protect any danger areas
against mechanical movement Risks, such as crushing, dragging, and
shearing.
17) Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended
for every system, as well as a warning sign adequately secured to the
frame structure, in addition to the devices mentioned at point “16”.
18) FAAC declines all liability as concerns safety and efficient operation of
the automated system, if system components not produced by FAAC
are used.
19) For maintenance, strictly use original parts by FAAC.
20) Do not in any way modify the components of the automated system.
21) The installer shall supply all information concerning manual operation
of the system in case of an emergency, and shall hand over to the
user the warnings handbook supplied with the product.
22) Do not allow children, things or adults to stay near the product while
it is operating.
23) Keep remote controls or other pulse generators away from children,
to prevent the automated system from being activated involuntarily.
24) Transit is permitted only when the automated system is idle.
25) The user must not attempt any kind of repair or direct action whatever
and contact qualified personnel only.
26) Maintenance: check at least every 6 months the efficiency of the
system, particularly the efficiency of the safety devices (including,
where foreseen, the operator thrust force) and of the release devices.
27) The S800H ENC automated system automates vehicle entrances -
pedestrians must have a separate entrance.
28) Power up the automated system only when expressly indicated.
29) Anything not expressly specified in these instructions is not permitted.
WARNINGS FOR THE INSTALLER
GENERAL SAFETY OBLIGATIONS
AUTOMATED SYSTEM S800H ENC
EC DECLARATION OF CONFORMITY
The Manufacturer
Company name: FAAC S.p.A.
Address: Via Calari, 10 - 40069 Zola Predosa BOLOGNA- ITALY
hereby declares that the following products:
Description: Underground operator for swing leafs gates
Model: S800H ENC
comply with the following applicable EU legislations:
• EMC Directive 2004/108/EC • ROHS Directive 2 2011/65/UE
Furthermore, the following harmonised standards have been applied:
• EN EN 60335-2-97:2006
• EN ISO 12100:2010 • EN 61000-6-2:2005
• EN 61000-6-3:2007
Bologna, 22-01-2015 CEO
A. Marcellan

4 532096 Rev. BS800H ENC
ENGLISH
Translation of the original instructions
DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY
(2006/42/CE ANN.II P.1, LETT. B)
Manufacturer and person authorised to prepare the relevant technical documentation
Company name: FAAC S.p.A.
Address: Via Calari, 10 - 40069 Zola Predosa BOLOGNA- ITALY
hereby declares that for the partly completed machinery:
Description:
Model: S800H ENC
the essential requisites of the Machinery Directive 2006/42/EC (including all applicable amendments) applied and met are:
RESS 1.1.2,1.1.3,1.1.4,1.1.5,1.1.6,1.2.1,1.3.1,1.3.2,1.5.1,1.5.4,1.5.9,1.5.13,1.6.3,1.7.1,1.7.2, 1.7.4
and that the relevant technical documentation has been compiled in compliance with part B ofAnnex VII.
Furthermore, the following harmonised standards have been applied:
• EN ISO 12100:2010 • EN 60335-1:2013 • EN EN 60335-2-97:2006
It is also hereby declared that the partly completed machinery identified above may not be commissioned until the final machine - into which it will be
incorporated - has been declared to conform to the provisions of the above mentioned Machinery Directive 2006/42/EC.
Bologna, 22-01-2015 CEO
A. Marcellan
1 DESCRIPTION
Bleed screw
Support handle
Pinion
Fixing screws
Mechanical limit switch
stops adjustment screw
hydraulic release lever
Oil filler cap
Engine
Electronic encoder
Support box
Bores for fixing cover
Slots for fixing jack
Support bush
Flaps for recessing support
box
Bore for power cable
or drain pipe
Mechanical release lever
(optional)
Key-operated release device
Release and adjustment key
and support bush
Splined bush
Cover
These instructions apply to the following models: S800H ENC SB/SBW - S800H ENC CBAC / 100° - 180°.
FAAC S800H ENC is an automation in a hydraulic monobloc (CLASS III), for the access of vehicles through swing gates. Retractable
in the ground, it does not change the looks of the gate. The model equipped with hydraulic lock does not require installation of
the electric lock, mechanically locking the leaf, up to 2 m, when the motor is not running. The model without hydraulic lock always
requires one or more electric locks to guarantee mechanical locking of the leaf.
S800H ENC automations are designed and built to automate swing gates. They must not be used in any other way.
Fig.1
TECHNICAL
FEATURES
CBAC OPERATOR OPERATOR
SB/SBW
Power supply (
V
)24
Absorbed power (W) 60 (*)
Protection rating IP 67
Oil type "FAAC HP OIL"
Operating temperature -20° C +55°C
Rated Operating Time (R.O.T.) Continuous duty at 55°C
Hydraulic lock Included Not included
Max torque (Nm) ** 500 (E024S) ; 600 (E124)
2 TECHNICAL FEATURES
Angular speed (°/sec) *** 5.5 (E024S) ; 8.2 (E124)
Max opening angle **** 113° (S800H ENC 110°)
187° (S800H ENC 184°)
Max leaf length (m) 2 4 (electric lock
mandatory)
Max leaf weight (kg) 800
* EACH INDIVIDUAL OPERATOR
** CONSIDERING 55 Bar OF STATIC PRESSURE IN THE CHAMBERS
*** CONSIDERING A PUMP FLOW RATE OF 0.6 lpm
**** 3° OF STROKE IS LOST DURING INSTALLATION
OF THE OPERATOR

5 532096 Rev. BS800H ENC
x 1
x 1
AB
Translation of the original instructions
ENGLISH
-
Ø Cable (max length)
Engine S800H ENC 2x2.5 mm² up to 8m, increase the cross-
section by 0.3 mm² for each additional m
Bus encoder 2x0.5 mm ²
BUS 2 Easy photocells 2x0.5 mm² (max 100 m)
Board power supply 2x2.5+T mm ²
Key-operated button 2x0.5 mm²
Flashing light 24 V 2x1.5 mm²
CLOSING LIMIT
SWITCH
4 INSTALLATION OF THE OPERATOR
4.1 OPERATOR WITHOUT EMERGENCY MECHANICAL RELEASE
3) Unscrew the cap (Fig.4 ref.A) on the screw of the closing limit
switch (Fig.4 ref. ), and make sure that the screw is tightened
all the way.
4)
Loosen the screw of the closing limit switch (Fig.4 ref.B) by one
turn
(Important to correctly couple the pinion-splined bush
during installation).
5) Turn the pinion of the operator using the supplied key (Fig.5
ref.), in the direction the gate closes, until it reaches the internal
stop of the piston and remove the key.
OPENING
LIMIT SWITCH
Turn the key to the mechanical stop
and remove it from the pinion
Fig.3
Fig.4
Fig.5
1) Bring the gate to the open position.
2) Referring to the instructions in chapter 7.1, act on the operator's
hydraulic release by turning the lever
(Fig.1 ref.) or using the specific key (Fig.1 ref.) turn the release
screw (Fig.3 ref.).
3 ELECTRICAL SET-UP
230 V ~ / 50 Hz
o
115 v ~ / 60Hz
(Depending
on control unit
chosen)
Fig.2
6) Without moving the pinion insert the supplied key on the op-
erator (Check the position of the pin on the pinion Fig.6 ref.),
and if needed turn the pinion to correct it (Important to correctly
couple the pinion-splined bush during installation).
NOTE: if necessary, screw the closing limit switch screw slightly.

6 532096 Rev. BS800H ENC
AB
C
AB
1
1
ENGLISH
Translation of the original instructions
Insert the key without moving the pinion and check
that it is at the following position
Fig.6
Fig.7
Fig.8
Fig.9
7) Remove the adjustment key, screw the cap of the limit switch
screw and grease the operator pinion.
8) Using the specific handles, insert the operator in the support
box figure 7, and position it as shown in figure 8 A, B.
9) Close the gate (Fig.9).
Fig.10
Fig.11
10) Lift the operator using the specific panels
(Fig.10 ref.A ), and insert the pinion in the splined bush of the
support box. To facilitate the operation, turn the operator until
they couple.
11) Position the supplied key beneath the operator as shown in
figure 10 ref. B to support the engine.
12) Insert and screw the fixing screws with the groover as shown
in figure 10 ref. C, to secure the operator to the support box, as
in figure 11.
13) Open and close the gate, checking the respective limit
switches, as described in chapter 5, and adjust them if necessary.
14) Hydraulically lock the operator according to the instructions
in chapter 7.1.
15) Perform the electrical connections, as described in the in-
structions of the electronic equipment, paying attention to the
polarity of the encoder.

S800H ENC
S800H ENC
Inserto Immagini - Pictures Collection
Inserto Immagini - Pictures Collection
Collection de Figures - Photo Kollektion
Collection de Figures - Photo Kollektion
Inserto imágenes - Fotoverzameling
Inserto imágenes - Fotoverzameling

40
10
250
580
=
=
360
90°90°
480
270
CASSETTA PORTANTE-SUPPORT BOX-CAISSON PORTANT
GEHÄUSE-CAJA PORTANTE-BEHUIZING
270
480
A=228
B=249
B
A
57
A
A(mm)
26 47
249
DEUTSCH FRANÇAIS ITALIANO
NEDERLANDS ESPAÑOL ENGLISH ITALIANO
FRANÇAIS
DEUTSCH
Quote in mm - Dimensions in mm - Cotes en mm - Maße in mm - Cotas en mm - Waarden in mm

S800H ENC
S800H ENC
Guida per l’utente - User’s guide
Guida per l’utente - User’s guide
Guide pour l’utilisateur - Anleitungen für den Benutzer
Guide pour l’utilisateur - Anleitungen für den Benutzer
Guía para el usuario - Gebruikersgids
Guía para el usuario - Gebruikersgids

3S800H ENC 532096 Rev. B
Translation of the original instructions
ENGLISH
Warning: Before performing the RELEASE or LOCK
operations, make sure power has been disconnected
to the operator.
AUTOMATION
USER'S GUIDE
GENERAL SAFETY STANDARDS
If installed and used correctly, the automation guarantees a high
degree of safety.
Some simple standards of conduct can help avoid accidental
problems:
- Do not pass through the leaves when they are moving. Wait for
them to be completely open before passing through.
- Do not stop between the leaves.
- Do not stop and do not allow children, persons or objects to
stop in the vicinity of the automation, especially while it is running.
- Do not allow children to play with the automation. Guard the
radio controls and any other pulse generator to keep the auto-
mation from being activated unintentionally.
- Do not intentionally hinder the movement of the leaves.
- Do not allow branches or shrubbery to interfere with the move-
ment of the leaves.
- Keep the indicator light systems efficient and well visible.
- Do not try to move the leaves by hand unless you have released
them.
- In the case of a malfunction, release the leaves to permit ac-
cess and wait for the technical intervention of qualified personnel.
- Once manual operation has been set, disconnect power to the
system before restoring normal operation.
- Do not modify the components of the automation system in
any way.
- Do not attempt any kind of repair or direct intervention and only
contact qualified personnel.
- Have the efficiency of the automation and of the safety devices
checked at least every six months by qualified personnel.
DESCRIPTION
These instructions apply to the following models:
S800H ENC CBAC - S800H ENC SB/SBW
The swing gate automation is a hydraulic monobloc which,
installed retractable in the ground, does not change the looks
of the gate.
The model equipped with hydraulic lock does not require instal-
lation of the electric lock, mechanically locking the leaf when
the motor is not running. The model without hydraulic lock always
requires one or more electric locks to guarantee mechanical
locking of the leaf.
S800H ENC automations are designed and built to automate
swing gates. They must not be used in any other way.
Regarding the chosen model, the system can automate leaves
up to 4 m and 800 kg.
The operators are managed by an electronic control unit, inside
an enclosure with an appropriate protection rating against atmos-
pheric agents. The leaves normally touch when they are closed.
When the electronic control unit receives an opening command
via the radio control or any other pulse generator, this activates
the hydraulic device which makes the leaves rotate to an open-
ing position permitting access.
If set to automatic mode, the leaves close on their own after a
selected pause time.
MANUAL OPERATION
HYDRAULIC RELEASE OF THE OPERATOR
If you need to move the gate by hand due to a power failure or
a malfunction in the automation, act on the hydraulic release
device by means of the specific lever or release key:
1) Remove the cover from the support box
2) Act on the release screw (Fig.1 ref.), (if there is no lever, insert
the hexagonal recess of the supplied key (Fig.2 ref.)):
- To RELEASE, turn the screw one turn anticlockwise (to keep oil
from escaping).
- To RELOCK, turn the screw clockwise to the mechanical stop.
Fig.1
RELEASE SCREW
RELEASE KEY
If in semi-automatic mode, a second pulse must be sent for
them to close.
A stop pulse (if foreseen) always stops movement.
For the detailed behaviour of the automation in the different
operating conditions, refer to the Installer technician.
The automation has type D safety devices (photocells) which
impair leaf movement when there is an obstacle in the area
they protect.
The S800H ENC has, as standard, a device which, connected
to an appropriate electronic appliance, detects the presence
of an obstacle and reverses the running direction of the leaves.
The indicator light indicates that the leaves are moving.

4S800H ENC 532096 Rev. B
ENGLISH
Translation of the original instructions
SUPPORT BRACKET
RELEASE KEY
RELEASE LEVER
Fig.3
EMERGENCY MECHANICAL RELEASE (OPTIONAL)
The operator has an optional manual emergency mechanical
release (Fig.3).
If you need to move the gate by hand due to a power failure
or a malfunction in the automation, act on the key-operated
release device.
The device is installed on the support bracket of the gate and
makes it possible to release the system both from inside and
outside the property.
MAINTENANCE
Have a qualified technician perform a functional check of the
system every six months, paying special attention to the efficiency
of the safety and release devices and to perfect functioning of
the gate hinges.
Also have the amount of oil in the tank checked. Use only
"FAAC HP OIL" for topping up.
PROTECTIVE
COVER
RELEASE KEY
RELEASE LEVER
Fig.4
Fig.2
EMERGENCY HYDRAULIC RELEASE (OPTIONAL)
The operator has an optional manual emergency hydraulic
release (Fig.2).
You must act on the key-operated release device when needing
to move the gate by hand without accessing the foundation box.
The device is installed at the base of the gate and allows you to
release the system.
Proceed as follows to move the leaf by hand:
1) To release, insert the key in the lock and turn it anticlockwise to
the mechanical stop.
4) Move the leaf by hand.
Proceed as follows to restore the system to normal operation
(from gate released):
1) To relock, insert the key in the lock and turn it clockwise until
the stop.
Proceed as follows to move the leaf by hand:
1) Open the protective cover (Fig.4 ref. ).
2) Insert the release key in the lock (Fig.4 ref. ) and turn it clock-
wise to the stop.
3) Pull the release lever towards you (Fig.4 ref. ).
4) Move the leaf by hand.
Proceed as follows to restore the system to normal operation
(from gate released):
1) Put the release lever back to its home position (Fig.3).
2) Insert the release key in the lock and turn it clockwise to the stop.
3) Move the leaf by hand until it hooks the lock on the locking
bracket.
4) Close the protective cap of the lock.

5S800H ENC 532096 Rev. B
www.faacgroup.com

==
NEDERLANDS ESPAÑOL DEUTSCH FRANÇAIS ENGLISH ITALIANO
ITALIANOENGLISH
FRANÇAIS
DEUTSCHESPAÑOLNEDERLANDS
PER GARANTIRE UNA CORRETTA INSTALLAZIONE OCCOR-
RE CHE L’ASSE DI ROTAZIONE DELL’ANTA, SIA PERFETTA-
MENTE ALLINEATO CON L’OPERATORE (Fig. 7)
TO GUARANTEE CORRECT INSTALLATION, THE ROTATION
AXIS OF THE LEAF MUST BE PERFECTLY ALIGNED WITH THE
OPERATOR (Fig. 7)
POUR GARANTIR UNE INSTALLATION CORRECTE, IL FAUT
QUE L’AXE DE ROTATION DU VANTAIL SOIT PARFAITEMENT
ALIGNÉ AVEC L’OPÉRATEUR (Fig. 7)
ZUR GEWÄHRLEISTUNG EINER SACHGEMÄSSEN
MONTAGE MUSS DIE DREHACHSE DES TORFLÜGELS
PERFEKT ZUM ANTRIEB GEFLUCHTET SEIN (Abb. 7)
PARA GARANTIZAR UNA CORRECTA INSTALACIÓN EL
EJE DE ROTACIÓN DE LA HOJA DEBE ESTAR ALINEADO
PERFECTAMENTE RESPECTO AL OPERADOR (Fig. 7)
OM EEN CORRECTE INSTALLATIE TE GARANDEREN MOET
DE ROTATIE-AS VAN DE POORTVLEUGEL PERFECT OP EEN
LIJN MET HET BEDIENINGSSYSTEEM ZIJN (Fig. 7)

DEUTSCH FRANÇAIS ITALIANO
NEDERLANDS ESPAÑOL ENGLISH ITALIANO
FRANÇAIS
DEUTSCH

7 532096 Rev. BS800H ENC
x 1
AB
x 1
11
Translation of the original instructions
ENGLISH
1) Bring the gate to the open position.
2) Referring to the instructions in chapter 7.1, act on the operator's
hydraulic release by turning the lever
(Fig.1 ref.) or using the specific key (Fig.1 ref.) turn the release
screw (Fig.12 ref.).
4.2 OPERATOR WITH EMERGENCY MECHANICAL RELEASE
3) Unscrew the cap (Fig.13 ref.A) on the screw of the closing limit
switch (Fig.13 ref. ), and make sure that the screw is tightened
all the way.
4)
Loosen the screw of the closing limit switch (Fig.13 ref.B) by
one turn
(Important to correctly couple the pinion-splined bush
during installation).
Fig.12
Fig.13
CLOSING
LIMIT SWITCH
OPENING
LIMIT SWITCH
Fig.15
Fig.14
Turn the key to the mechanical stop
and remove it from the pinion
Insert the key without moving the pinion and check
that it is at the following position
5) Turn the pinion of the operator using the supplied key (Fig.14
ref.), in the direction the gate closes, until it reaches the internal
stop of the piston and remove the key.
6) Without moving the pinion insert the supplied key on the
operator (Check the position of the pin on the pinion Fig.15
ref.), and if needed turn the pinion to correct it (Important to
correctly couple the pinion-splined bush during installation).
NOTE: if necessary, screw the closing limit switch screw slightly.
7) Remove the adjustment key, screw the cap of the limit switch
screw and grease the operator pinion.
8) Using the specific handles, insert the operator in the support
box figure 16, and position it as shown in figure 17 A, B.
9) Close the gate (Fig. 18).
10) Free the mechanical release (fig. 19) referring to paragraph
7.2 .

8 532096 Rev. BS800H ENC
90°
AB
C
AB
ENGLISH
Translation of the original instructions
Fig.16
Fig.17
Fig.18
Fig.19
Fig.20
Fig.21
Fig.22
5 INTERNALMECHANICAL LIMITSWITCHES
(POSITIVESTOP)
The S800H ENC operator is supplied, as per standard, with internal
opening and closing mechanical limit switches. This facilitates
installation as you do not need to make mechanical stops.
The mechanical limit switches (POSITIVE STOP) can be adjusted
in the last 30° of the operator's MAXIMUM stroke, opening and
closing.
FAAC SUPPLIES THE LIMIT SWITCHES FULLY OPEN (MAXIMUM PINION
ROTATION ANGLE).
11) Ring the released gate to the open position, checking that the
release part freed from the gate remains at the closed position
as in figure 20 ref..
12) Lift the operator using the specific panels
(Fig.21 ref.A ), and insert the pinion in the splined bush of the
support box. To facilitate the operation, turn the operator until
they couple.
13) Place the supplied key beneath the operator (Fig.21 ref. B)
to support the engine.
14) Insert and screw the fixing screws with the groover (Fig.21
ref. C, to secure the operator to the support box, as in figure 22.
15) Close the gate and secure it to the mechanical release.
16) Open and close the gate, checking the respective limit
switches, as described in chapter 5, and adjust them if necessary.
17) Hydraulically lock the operator according to the instructions
in chapter 7.1.
18) Perform the electrical connections, as described in the in-
structions of the electronic equipment, paying attention to the
polarity of the encoder.

9 532096 Rev. BS800H ENC
A
B
Translation of the original instructions
ENGLISH
5.1 LIMIT SWITCH ADJUSTMENT
OPENING LIMIT
SWITCH
CLOSING LIMIT SWITCH
Fig.23
1) Release the operator hydraulically. (See chap.7.1)
2) Close the leaf, bringing it to the closing position by hand
3) Unscrew the cap (Fig.23 ref. A-B) of the closing limit switch
screw (Fig.23 ref.).
4) UNSCREW the
closing limit switch screw
(Fig.23 ref.), until the
leaf appears to be moving.
5) Screw the cap (Fig.23 ref. A) of the limit switch screw back on.
6) Open the leaf, bringing it to the opening position by hand.
7) Unscrew the cap (Fig.23 ref. A-B) of the opening limit switch
screw (Fig.23 ref.).
8) UNSCREW the
opening limit switch screw
(Fig.23 ref.), until the
leaf appears to be moving.
9) Screw the cap of the limit switch screw back on.
10) Open and close the gate to make sure that the limit switches
are adjusted correctly.
11) Lock the operator, following the instructions in chapter 7.1.
CLOSING POSITION
OPENING POSITION
6 FINAL OPERATIONS
To avoidexcessive voltage drops,the enginecables should
have a cross-section of 2.5 mm, and be no longer than 20
m. The overall extension of the BUS line cables must not
exceed 100 m (all the accessory BUS connection cables
included)
1) Connect the engine (Fig.1 ref. ) and the encoder (Fig.1 ref.
) to the electronic equipment according to the instructions.
2) Secure the cover of the support box with the supplied screws
(Fig.24;25).
3) Where foreseen by standards in force, apply at least two "auto-
matic movement hazard" signs on both sides of the automation.
7 MANUAL OPERATION
Fig.24
Fig.25
7.1 HYDRAULIC RELEASE OF THE OPERATOR
If you need to move the gate by hand due to a power failure or
a malfunction in the automation, act on the hydraulic release
device by means of the specific lever (Fig.1 ref.) or release
key (Fig.1 ref.):
1) Remove the cover from the support box.
2) Act on the release screw (Fig.26 ref.), (if there is no lever,
insert the hexagonal recess of the supplied key (Fig.26 ref.)):
- To RELEASE, turn the screw one turn anticlockwise (to keep oil
from escaping)
- To RELOCK, turn the screw clockwise to the mechanical stop
(without forcing it).
RELEASE KEY
RELEASE SCREW
Fig.26
Before performing the release and lock operations, make
sure powerhas been disconnectedto the operatorand that
it is not in movement.

10 532096 Rev. BS800H ENC
ENGLISH
Translation of the original instructions
7.2 EMERGENCY MECHANICAL RELEASE (OPTIONAL)
The S800H ENC operator has an optional manual emergency
mechanical release.
If you need to move the gate by hand due to a power failure
or a malfunction in the automation, act on the key-operated
release device.
The device is installed on the support bracket of the gate (Fig.27
ref. ) and makes it possible to release the system both from
inside and outside the property. NO BUSHES OTHER THAN THOSE
SUPPLIED ARE NECESSARY.
SUPPORT BRACKET
RELEASE KEY
RELEASE LEVER
PROTECTIVE
COVER
RELEASE KEY
RELEASE LEVER
Proceed as follows to move the leaf by hand:
1) Open the protective cover (Fig.28 ref. ).
2) Insert the release key in the lock (Fig.28 ref. ) and turn it
clockwise to the stop.
3) Pull the release lever towards you (Fig.28 ref. ).
4) Move the leaf by hand.
Proceed as follows to restore the system to normal operation:
1) Put the release lever back to its home position (Fig.27).
2) Insert the release key in the lock (Fig.28 ref. ) and turn it an-
ticlockwise to the stop and remove it.
3) Close the protective cap of the lock.
4) Move the leaf by hand until it hooks the locking bracket.
The presence of air in the hydraulic circuit causes the automation
to malfunction. This can be seen when the leaf moves abnormally
and makes too much noise while operating.
Proceed as follows to solve the problem:
1) Command the gate to open.
2) While the leaf is moving, loosen the opening bleed screw
(Fig.29 ref.).
3) Allow air to exit the hydraulic circuit through the bleed screw
until non-emulsified oil seeps out.
4) Tighten the bleed screw before the operator finishes the open-
ing cycle.
5) Command the gate to close.
6) While the leaf is moving, loosen the closing bleed screw (Fig.29
ref.).
7) Allow air to exit the hydraulic circuit through the bleed screw
until non-emulsified oil seeps out.
8) Tighten the bleed screw before the operator finishes the clos-
ing cycle.
9) Repeat these operations several times.
10) Restore the oil level so that it is just below the filler cap (Fig.
30 ref.).
8.1 BLEED OPERATIONS
The S800H ENC operator is supplied with the hydraulic
circuit without air. It does not need to be bled. It is only
necessarywhen performingmaintenance onthe hydrau-
lic system or when topping up the oil level.
8 MAINTENANCE
Perform a functional check of the system at least every six
months, paying special attention to the efficiency of the safety
and release devices (including the operator's thrust force) and
to perfect functioning of the gate hinges.
The safety devices installed in the system must be checked every
six months.
Fig.27
Fig.28
Fig.30
BLEED SCREW FOR
OPENING
BLEED SCREW FOR
CLOSING
Fig.29


532096 Rev. B
SEDE - HEADQUARTERS
FAAC S.p.A.
Via Calari, 10
40069 Zola Predosa (BO) - ITALY
Tel.+3905161724-Fax+39051758518
www.faac.it - www.faacgroup.com
SUBSIDIARIES
AUSTRIA
FAAC GMBH
Salzburg - Austria
tel. +43 662 8533950
www.faac.at
FAAC TUBULAR MOTORS
tel. +49 30 56796645
www.faac.at
AUSTRALIA
FAAC AUSTRALIA PTY LTD
Homebush, Sydney - Australia
tel. +61 2 87565644
www.faac.com.au
BENELUX
FAAC BENELUX NV/SA
Brugge - Belgium
tel. +32 50 320202
www.faacbenelux.com
FAAC TUBULAR MOTORS
tel. +31 475 406014
www.faacbenelux.com
CHINA
FAAC SHANGHAI
Shanghai - China
tel. +86 21 68182970
www.faacgroup.cn
FRANCE
FAAC FRANCE
Saint Priest, Lyon - France
tel. +33 4 72218700
www.faac.fr
FAAC FRANCE - AGENCE PARIS
Massy, Paris - France
tel. +33 1 69191620
www.faac.fr
FAAC FRANCE - DEPARTEMENT
VOLETS
Saint Denis de Pile - Bordeaux - France
tel. +33 5 57551890
www.faac.fr
ASSISTENZA IN ITALIA
SEDE
tel. +39 051 6172501
www.faac.it/ita/assistenza
FIRENZE
tel. +39 055 301194
GERMANY
FAAC GMBH
Freilassing - Germany
tel. +49 8654 49810
www.faac.de
FAAC TUBULAR MOTORS
tel. +49 30 5679 6645
www.faac.de
INDIA
FAAC INDIA PVT. LTD
Noida, Delhi - India
tel. +91 120 3934100/4199
www.faacindia.com
IRELAND
NATIONALAUTOMATION LIMITED
Boyle,Co. Roscommon - Ireland
tel. +353 071 9663893
www.faac.ie
MIDDLE EAST
FAAC MIDDLE EAST FZE
Dubai Silicon Oasis free zone
tel. +971 4 372 4187
www.faac.ae
NORDIC REGIONS
FAAC NORDIC AB
Perstorp - Sweden
tel. +46 435 779500
www.faac.se
POLAND
FAAC POLSKA SP.ZO.O
Warszawa - Poland
tel. +48 22 8141422
www.faac.pl
RUSSIA
FAAC RUSSIA LLC
Moscow - Russia
tel. +7 495 646 24 29
www.faac.ru
MILANO
tel +39 02 66011163
PADOVA
tel +39 049 8700541
ROMA
tel +39 06 41206137
TORINO
tel +39 011 6813997
SPAIN
CLEM, S.A.U.
S. S. de los Reyes, Madrid - Spain
tel. +34 091 358 1110
www.faac.es
SWITZERLAND
FAAC AG
Altdorf - Switzerland
tel. +41 41 8713440
www.faac.ch
TURKEY
FAAC OTOMATøK GEÇøS SøSTEMLERø
SAN. VE TøC. LTD. ùTø.
Ça÷layan, Ka÷Õthane, østanbul - Turkey
tel.+90 (0)212 – 3431311
www.faac.com.tr
UNITED KINGDOM
FAAC UK LTD.
Basingstoke, Hampshire - UK
tel. +44 1256 318100
www.faac.co.uk
U.S.A.
FAAC INTERNATIONAL INC
Rockledge, Florida - U.S.A.
tel. +1 904 4488952
www.faacusa.com
FAAC INTERNATIONAL INC
Fullerton, California - U.S.A.
tel. +1 714 446 9800
www.faacusa.com
Other manuals for S800H ENC
1
Table of contents
Other FAAC Gate Opener manuals

FAAC
FAAC E600 User manual

FAAC
FAAC R180N User manual

FAAC
FAAC 844 User manual

FAAC
FAAC 402 User manual

FAAC
FAAC 413 Series User manual

FAAC
FAAC 770 COMPACT User manual

FAAC
FAAC Safe Zone S418 User manual

FAAC
FAAC S700H SB User manual

FAAC
FAAC 746 ER CAT User manual

FAAC
FAAC Estate Slide E-SL 1200 Series User manual