FEATURES
• Self–Priming
• Dry Running
• Soft Noise Absorbing Mounts
• Snap–in Port Fittings
• Built-in Bypass : Less Pulsation
• Reduces need for accumulator tank
• Corrosion Resistant Materials
• Meets ISO 8846 (Ignition protection)
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing
Totally Enclosed. CE Models are
fully suppressed.
Pump: Three chamber diaphragm design
Self-priming up to 9 feet suction lift;
Pump able to run dry without damage Dimensions English (SI)
*CE fully suppressed models are identified by a prefix “R” and a CE mark on the label.(i.e. R3626144).
Self Declaration Of Conformance (SDOC) is available upon request.
OPERATION
With pump switch off and battery fully charged, fill water tank, open all faucets, then turn pump switch on. Water will
begin to flow. When the water is free of air, turn faucets off. Remember, you are filling the water heater and the toilet
and shower lines. When all valves are shut-off, pump will stop. Should pump fail to stop, turn switch off and see the
trouble shooting guide. CAUTION - Pump surface will get hot to the touch if operated for extended periods of time
under pressurized conditions.
2.25"
3.12"
4.24"
4.75"
3.18"
9.04"
(80 mm) (65 mm)
(229 mm)
(80 mm)
(108 mm)
(121 mm)
DIMENSIONAL DRAWING
Model 3426 / 3526 / 3626 Series
Pump Height Length Width Weight
Series inches (mm) inches (mm) inches (mm) Lb (Kg)
3X26XXX 4.75 (121) 9.00 (229) 6.00 (152) 3.50 (1.59)
MODEL* VOLTS AMP DRAW
@10 psi (0.7 bar)
FLOW
GPM (LPM)
PRESSURE SWITCH
Max psi (bar)
BYPASS
03526144 12V dc 4.4 2.9 (11) 50 (3.4) Yes
R3626344 24V dc 2.2 2.9 (11) 40 (2.8) Yes
R3426144 12V dc 4.4 2.9 (11) 25 (1.7) Ye s
R3426344 24V dc 2.2 2.9 (11) 25 (1.7) Yes
R3426148 12V dc 3.5 2.0 (8) 25 (1.7) Ye s
R3426348 24V dc 1.7 2.0 (8) 25 (1.7) Ye s
C
A
B
Red (+)
Fuse
(+)
Switch
Battery
Black ( )
-
)
-
)
INSTALLATION WIRING
STEP 1
Remove shipping plugs from pump ports. Some water
from factory testing may spill out.
STEP 2
Connect fittings supplied with the pump to the RV’s
plumbing. Use 1/2’ I.D. Flexible hose (preferably braided
or reinforced) to reduce vibration through the plumbing
system as shown on Fig. 1. Use hose clamps on the
slip-on barb hose connectors.
STEP 3
Slide rubber mounts fully into 4 mounting tracks.
STEP 4
Mount pump vertically, with pump head down or
horizontally in an accessible location. If mounting
vertically, motor up, attach motor mounts first then pump
head mounts, while supporting weight of pump.
STEP 5
Install inlet A and discharge B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.
STEP 6
Install a Flojet strainer in an accessible location (for
inspection and cleaning) between the tank and pump
inlet.
This strainer or equivalent is required for pump warranty
to be valid.
STEP 1
Use 14 gauge stranded wire to 20’, 12 gauge to 50’,
from power source.
STEP 2
Use a 10-15 amp rated on-off switch on the (+) positive
(red) motor lead.
STEP 3
Install a 10 amp fuse protection on the positive lead.
FIG. 1
Note: To help reduce noise and vibration of the pump
through the system use flexible lines on the inlet and
outlet of the pump as shown above. Be sure to use
lines rated to not collapse under pump vacuum.
City Water
Inlet
Check
Valve
Flojet Inlet
Strainer
Water
Heater
Water
Tank
ACCESSORIES
QUICK CONNECT PORT SYSTEM
20381000
PUMP PORT x
1/2" MALE QEST.
STRAIGHT
20381002
PUMP PORT x
1/2" HOSE BARB
STRAIGHT
20381006
PUMP PORT x
3/4" HOSE BARB
STRAIGHT
20381007
QUAD PORT x
GARDEN HOSE
STRAIGHT
20381008
PUMP PORT x
1/2" MALE QEST.
90°ELBOW
20381009
PUMP PORT x
1/2" HOSE BARB
90°ELBOW
20381010
PUMP PORT x
3/4" HOSE BARB
90°ELBOW
14
3
2
WARNING: BEFORE SERVICING PUMP, TURN OFF PUMP AND DRAIN WATER FROM SYSTEM!!
AUTOMATIC WATER SYSTEM PUMP SERVICE PARTS
TROUBLESHOOTING
Failure to Prime - Motor operates, but no pump discharge
• Restricted intake or discharge line
• Air leak in intake line
• Debris in pump
• Punctured pump diaphragm (pump leaks)
•Crack in pump housing
Motor falls to turn on
• Loose wiring connection
•Pump circuit has no power
• Blown fuse
• Pressure switch failure
• Defective motor
Pulsating Flow
• Restricted pump delivery. Check discharge lines, fittings
and valves for clogging or undersizing
Pump Fails to Turn Off After All Fixtures Are Closed
• Empty water tank
• Insufficient voltage to pump (low battery)
• Punctured pump diaphragm (pump leaks)
• Discharge line leak
• Defective pressure switch
Low Flow and Pressure
• Air leak at pump intake
•Accumulation of debris inside pump and plumbing
• Worn pump bearing (excessive noise)
• Punctured pump diaphragm (pump leaks)
• Defective motor
EXPLODED VIEW
• The above part numbers are packaged with 2 fittings per bag.
STRAINERS Pump Series Strainer Number Inlet Outlet Screen
3X26XXX 1740012 1/2 Barb Quad Port 40 Mesh
1740002 1/2 Barb 1/2 Barb 40 Mesh
1740004 1/2 M Qest 1/2 M Qest 40 Mesh
1740014 1/2 M Qest Quad Port 40 Mesh
KEY# DESCRIPTION 3426XXX 3526XXX 3626XXX
1 Pressure Switch 2091025 2091050 2091040
2 Pumphead Assembly 20406047A (2.9 gpm) 20406045A 20406046A
20406048A (2.0 gpm)
3 Check Valve Assembly 20407034 20407034 20407034
4 Slide Clips (Pair) 21000407A 21000407A 21000407A
Winterizing Sanitizing
SYSTEM CARE AND MAINTENANCE
Allowing water to freeze in the system may result in
damage to the pump and plumbing system.
Non-Toxic antifreeze for potable water may be used with
Flojet pumps. Follow manufacturers recommendations.
Refer to coach or equipment manufacturers instructions
for their specific winterizing and drainage procedures.
Do not use automotive antifreeze to winterize potable
water systems. These solutions are highly toxic and may
cause serious injury or death if ingested.
1. Drain the water tank. Open tank drain valve. You may
use the pump to drain the tank by opening all the
faucets in the system. Allow the pump to operate untill
the tank is empty. Do not operate the pump more than
15 minutes continuously.
2. Open all faucets and purge the water from the
plumbing system. Turn power to the pump off. Be sure
that all the water from the drain lines are drained.
3. Remove quick connect inlet and outlet fittings from the
pump and turn the pump on to pump out remaining
water from the pump head. Be sure to have a catch pan
or a rag under the pump to prevent water from spilling
on to the RV. Turn the pump off once the plumbing is
empty. Leave the fittings disconnected from the pump
until the system is ready to be used again. Make a note
on your tank filler that the plumbing is not connected.
4. Be sure that all faucets are left open to protect against
damage to the plumbing.
Portable water systems require periodic maintenance to
deliver a consistent flow of fresh water. Depending on
use and the environment the system is subject to,
sanitizing is recommended prior to storing and before
using the water system after a period of storage.
Systems with new components, or ones that have been
subjected to contamination, should also be disinfected
as follows:
NOTE: The sanitizing procedure is in conformance with
the approved procedures of RVIA ANSI A119.2 and the
US Public Health Service.
1. Use of the following methods to determine the amount
of common household bleach needed to sanitize the
tank.
1. A) Multiply “gallons of tank capacity” by 0.13; the
result is the ounces of bleach needed to sanitize
the tank.
1. B) Multiply “Liters of tank capacity” by 1.0; the result
is the milliliters of bleach needed to sanitize the
tank.
2. Mix into solution the proper amount of bleach within a
container of water
3. Pour the solution (water/bleach) into the tank and fill
the tank with potable water.
4. Open ALL faucets (hot and cold) allowing the water to
run until the distinct odor of chlorine is detected.
5. The standard solution must have four (4) hours of
contact time to disinfect completely. Doubling the
solution concentration allows for contact time of one
(1) hour.
6. When the contact time is completed, drain the tank.
Refill with potable water and purge the plumbing of all
sanitizing solution.
WARRANTY
FLOJET warrants this product to be free of defects in material
and/or workmanship for a period of two years after purchase by
the customer from FLOJET. During this two warranty period,
FLOJET will at its option, at no charge to the customer, repair or
replace this product if found defective in material or
workmanship, with a new or reconditioned product, but not to
include costs of removal or installation.
This is only an overview of our Limited Warranty. If you would
like a copy of our warranty, please call or write FLOJET.
RETURN PROCEDURE
Prior to returning any product to FLOJET, call customer service
for an authorization number. This number must be written on the
outside of the shipping package. Place a note inside the
package with an explanation regarding the reason for return as
well as the authorization number. Include your name, address
and phone number.
Copyright 2005, ITT Industries Printed in U.S.A. All Rights Reserved Form: 81000-384 Rev. B 06/2005
U.S.A.
Flojet
Cape Ann Industrial Park
Gloucester, MA 01930
Tel: 978.281.0440
Fax: 978.283.2619
UNITED KINGDOM
Flojet
Bingley Road, Hoddesdon
Hertfordshire EN11 OBU
Tel: +44 (0) 1992 450145
Fax: +44 (0) 1992 467132
CANADA
Fluid Products Canada
55 Royal Road
Guelph, Ontario N1H 1T1
Tel: 519 821.1900
Fax: 519 821.2569
JAPAN
NHK Jabsco Company Ltd.
3-21-10, Shin-Yokohama
Kohoku-Ku, Yokohama, 222
Tel: 045.475.8906
Fax: 045.475.8908
GERMANY
Jabsco GmbH
Oststrasse 28
22840 Norderstedt
Tel: +49-40-53 53 73 -0
Fax: +49-40-53 53 73 -11
ITALY
Jabsco Marine Italia
Via Tommaseo, 6
20059 Vimercate, Milano
Tel: +39 039 685 2323
Fax: +39 039 666 307
www.flojet.com

This manual suits for next models

2

Other FLOJET Water Pump manuals

FLOJET G70C Series Owner's manual

FLOJET

FLOJET G70C Series Owner's manual

FLOJET G-57 Series Installation instructions

FLOJET

FLOJET G-57 Series Installation instructions

FLOJET 02840100A Operating and installation instructions

FLOJET

FLOJET 02840100A Operating and installation instructions

FLOJET quad II diaphragm 4125 series User manual

FLOJET

FLOJET quad II diaphragm 4125 series User manual

FLOJET 03526-144 User manual

FLOJET

FLOJET 03526-144 User manual

FLOJET N5000 Series Operation manual

FLOJET

FLOJET N5000 Series Operation manual

FLOJET 18555-000 User manual

FLOJET

FLOJET 18555-000 User manual

FLOJET N5100-010 Guide

FLOJET

FLOJET N5100-010 Guide

FLOJET 4300 Series User manual

FLOJET

FLOJET 4300 Series User manual

FLOJET R4515-743 User manual

FLOJET

FLOJET R4515-743 User manual

FLOJET 4325 Series User manual

FLOJET

FLOJET 4325 Series User manual

FLOJET 2100-12 User manual

FLOJET

FLOJET 2100-12 User manual

FLOJET G56 User manual

FLOJET

FLOJET G56 User manual

FLOJET R3526144 User manual

FLOJET

FLOJET R3526144 User manual

FLOJET BevJet Compact User manual

FLOJET

FLOJET BevJet Compact User manual

FLOJET N5100 Series Guide

FLOJET

FLOJET N5100 Series Guide

FLOJET 4105 Series User manual

FLOJET

FLOJET 4105 Series User manual

FLOJET 4305-144 User manual

FLOJET

FLOJET 4305-144 User manual

FLOJET N5000 User manual

FLOJET

FLOJET N5000 User manual

FLOJET 2125 Series User manual

FLOJET

FLOJET 2125 Series User manual

FLOJET G573 User manual

FLOJET

FLOJET G573 User manual

FLOJET Triplex Diaphragm 3426 Series User manual

FLOJET

FLOJET Triplex Diaphragm 3426 Series User manual

FLOJET G257 Series Guide

FLOJET

FLOJET G257 Series Guide

FLOJET R3B21 Series User manual

FLOJET

FLOJET R3B21 Series User manual

Popular Water Pump manuals by other brands

Little Giant BSC33 owner's manual

Little Giant

Little Giant BSC33 owner's manual

Becker VXLF 2.200 operating instructions

Becker

Becker VXLF 2.200 operating instructions

Becker U 4.100 operating instructions

Becker

Becker U 4.100 operating instructions

FTI TT Series Operations & parts manual

FTI

FTI TT Series Operations & parts manual

Kessel Minilift S original operation manual

Kessel

Kessel Minilift S original operation manual

Prio Prio Jet X845 user guide

Prio

Prio Prio Jet X845 user guide

EMP WP29 installation manual

EMP

EMP WP29 installation manual

NAVAC PRO Series user manual

NAVAC

NAVAC PRO Series user manual

GORMAN-RUPP PUMPS T SERIES Installation, operation and maintenance manual

GORMAN-RUPP PUMPS

GORMAN-RUPP PUMPS T SERIES Installation, operation and maintenance manual

Graco SaniForce BV Series instructions

Graco

Graco SaniForce BV Series instructions

Affetti Pumps CGV-L user manual

Affetti Pumps

Affetti Pumps CGV-L user manual

Edwards D372-15-805 instruction manual

Edwards

Edwards D372-15-805 instruction manual

MPS HR1200 user guide

MPS

MPS HR1200 user guide

Vacmaster PE401 Operator's manual

Vacmaster

Vacmaster PE401 Operator's manual

Grundfos TPE 2 Series Installation and operating instructions

Grundfos

Grundfos TPE 2 Series Installation and operating instructions

Lincoln HTL-429 manual

Lincoln

Lincoln HTL-429 manual

Alcatel Vacuum Technology ATP 100 Service manual & troubleshooting guide

Alcatel Vacuum Technology

Alcatel Vacuum Technology ATP 100 Service manual & troubleshooting guide

ITT 3610 i-FRAME manual

ITT

ITT 3610 i-FRAME manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.