Section 2 -Calibration
2.1 Calibration Mode ..........................................................................................
2-1
a.
Calibrating the Temperature....................................................................
2-1
Temperature Stabilization Periods...........................................................
2-1
b.
Calibrating the Thermal Conductivity
CO
2 System ................................2-2
c. Calibrating the TIC
%C0
2 Zero to Ambient ...........................................2-3
TIC CO2 Sensor Stabilization Periods ................................,...................2-3
d.
Calibrating the TIC
%C0
2 Span..............................................................2-3
e.
Calibrating the Infra-Red CO2 System ....................................................2-4
IR
CO
2 Sensor Stabilization Times.........................................................2-4
f.
Calibrating the O2 System .......................................................................2-5
O2 Sensor Stabilization Times................................................................2-5
g.
Calibrating the Relative Humidity ..........................................................2-5
Relative Humidity Stabilization Times..................................................2-5
Chart 2-1, Calibrate Mode .......................................................................2-7
Section 3 - Configuration
3.1 Configuration Mode ......................................................................................
3-1
a.
Turning the Audible
Alann
ONIOFF......................................................
3-1
b. Setting an Access Code ...........................................................................
3-1
c.
Setting a Low Temp
Alann
Limit (tracking alarm)................................
.3-1
d.
Setting a High Temp Alarm Limit (tracking alarm)................................3-2
e.
Enabling Temp Alarms to Trip Contacts.................................................3-2
f.
Setting a Low CO2 Alarm Limit (tracking alarm)....................................3-2
g. Setting a High CO2
Alann
Limit (tracking alarm) ..................................3-3
h.
Enabling
CO
2 Alarms to Trip Contacts ...................................................3-3
i. Setting a New Zero Number for TIC CO2 Sensors...................................3-3
j.
Setting a New SpanNumber for TIC CO2 Sensors ..................................3-4
k.
Setting a Low RH Alarm Limit...............................................................3-4
1.
Enabling RH Alarms to Trip Contacts .....................................................3-4
In.
New
O2 CelL...........................................................................................3-5
n.
Setting a Low O2 Alarm Limit (tracking alarm)......................................3-5
o.
Setting a High O2 Alarm Limit (tracking alarm).....................................3-5
p.
Enabling O2Alarms to Trip Contacts ......................................................3-6
IX