Furuno felcom15 User manual

SHIP SECURITY ALERT SYSTEM (SSAS)
(For FELCOM12/15/16)

The paper used in this manual
is elemental chlorine free.
FURUNO Authorized Distributor/DealerFURUNO Authorized Distributor/Dealer
9-52 Ashihara-cho,9-52 Ashihara-cho,
Nishinomi
y
a 662-8580, JAPANNishinomi
y
a 662-8580, JAPAN
Tele
p
hone :Tele
p
hone : 0798-65-21110798-65-2111
FaxFax 0798-65-42000798-65-4200
::
FIRST EDITION :FIRST EDITION :MAY.MAY. 20042004
Printed in JapanPrinted in Japan
A
ll ri
g
hts reserved.
A
ll ri
g
hts reserved.
DD :: SEP.SEP. 09, 200509, 2005
Pub. No.Pub. No. OME-56351OME-56351
*
00015035913
*
*
00015035913
*
*
00015035913
*
*
00015035913
*
(( DAMIDAMI )) IC-307(SSAS)IC-307(SSAS) * 0 0 0 1 5 0 3 5 9 1 3 ** 0 0 0 1 5 0 3 5 9 1 3 *
*
OME
56351
D
00
*
*
OME
56351
D
00
*
*
OME
56351
D
00
*
*
OME
56351
D
00
*
* O M E 5 6 3 5 1 D 0 0 ** O M E 5 6 3 5 1 D 0 0 *

1
TABLE OF CONTENTS
SYSTEM CONFIGURATION.........................................................................................2
1. OVERVIEW OF SSAS..............................................................................................4
2. INSTALLATION.........................................................................................................6
2.1 Mounting ......................................................................................................................... 6
2.1.1 Junction box (for FELCOM 16) ............................................................................... 6
2.1.2 I/F box IC-312 (for FELCOM 12)............................................................................. 7
2.1.3 SSAS alert unit ....................................................................................................... 8
2.2 Wiring............................................................................................................................ 10
2.2.1 Junction box (for FELCOM 16) ............................................................................. 10
2.2.2 I/F box IC-312 (for FELCOM 12)........................................................................... 11
2.2.3 SSAS alert unit ..................................................................................................... 12
2.3 Initial Settings................................................................................................................ 13
3. OPERATION............................................................................................................14
3.1 Operation Mode ............................................................................................................ 14
3.1.1 Changing the password ........................................................................................ 14
3.1.2 SSAS manager mode ........................................................................................... 15
3.2 Setting SSAS Report Destination and Message Contents............................................. 16
3.3 Transmitting SSAS Report ............................................................................................ 19
3.4 Testing the Button .........................................................................................................21
3.5 SSAS Report Test ......................................................................................................... 27
OUTLINE DRAWINGS...............................................................................................D-1
INTERCONNECTION DIAGRAMS...........................................................................S-1

2
SYSTEM CONFIGURATION
Regulations require at least two SSAS alert units.
FELCOM 15
Printer
PP-510
ANTENNA
UNIT
IC-115
TERMINAL UNIT
IC-215
JUNCTION
BOX
IC-315
Navigator
100-115/200-230 VAC
1φ, 50/60 Hz
: Standard Supply
: Option
: Local Supply
AC-DC Power Supply
PR-240-CE*1
*1 Any AC-DC power supply
fulfilling requirements of
IEC 60945 may be used.
Personal
Computer
(PC/AT compatible)
EGC Printer
PP-50
Shipboard LAN (Ethernet)
GPS receiver
OP16-24
Mini Keyboard
DGPS
Distress Alert/
Received Call Unit
IC-305
Alarm Unit
IC-306
24 VDC
Printer
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
(Max. 3 units)
SSAS Alert Unit
IC-307
12-24 VDC
24 VDC
24 VDC
FELCOM 16
: Standard
: Option
: Local Supply
PRINTER
ANTENNA
UNIT
IC-116
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
AC-DC
Power Supply
PR-240-CE
PERSONAL
COMPUTER
(PC/AT compatible)
POWER
I
O
INMARSATMINI-C MOBILE EARTH STATION
FURUNO
POWER
LOGIN
TX
ERROR
JUNCTION BOX
IC-315
100-115/200-230 VAC
1φ, 50/60 Hz
12-24 VDC
24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
(Max. 3 units)
SSAS Alert Unit
IC-307

3
FELCOM 12
Navigator
: Standard
: Option
: User Supply
INMARSAT-C MOBILE EARTH STATION
POWER
ON OFF
POWER BRIGHT CONTRAST
Antenna Unit
IC-112
Terminal Unit
IB-581/IB-582
24 VDC
Communication
Unit
IC-212
Mini Keyboard
24 VDC
Priinter
PP-510
24 VDC
100/110/200/220V
1φ, 50/60 Hz AC-DC
Power Supply
PR-300
Distress Alert Unit
IC-302
Received Call Unit
IC-303
Distress Alert Unit
IC-302
OR
Distress Message Controller
DMC-5 24 VDC
PC
(PC/AT compatible)
OR
Terminal Unit
IB-581/IB-582
SSAS Alert Unit
IC-307
SSAS Alert Unit
Interface
IC-312
24 VDC
SSAS Alert Unit
IC-307 (Max. 3 units)
SSAS Alert Unit
IC-307

4
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15/FELCOM 12 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting
specified addresses (for example, your ship’s company) that your ship is under attack by
intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed
before 01 July 2004 to install an SSAS.
When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.
The SSAS is protected with a password to prevent unauthorized setting or testing of it by
other than the ship’s captain or authorized personnel.
Headquarters
Ship
Ship's Company,
Management Company
Inmarsat System
Ship Name, MMSI No.,
Ship Position, etc.

5
SSAS operation flow
1.Open the cover of the button and then press the button.
(This is a latch-type button;hit and release to activate the button.)
2.If addresses have been preset, the SSAS report is sent to one
address 30 seconds after the button is activated.
(Max. 5 addresses)
(You may cancel transmission of the SSAS report by pressing the
button again within 30 seconds of the initial press.)
3.An LES sends acknowledgement to your ship.
4.Steps 2-3 and are repeated in case of multiple addressees.
5.Continuous transmission of the SSAS report begins.
(The interval at which to transmit the SSAS report to each address
can be specified.The SSAS report is continuously transmitted
while the button is ON, at the interval selected.)
↓
↓
↓
↓
6.To stop transmission, press the button again to deactivate it.
(This is only possible in the SSAS manager mode. See
paragraph 3.1.)

6
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16; it is
already installed on the FELCOM 15.
Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.
Standard compass: 1.0 m
Steering compass: 0.7 m
1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
120 ±0.5
70 ±0.5
Junction box IC-315
The junction box is connected to the communication unit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.

7
2.1.2 I/F box IC-312 (for FELCOM 12)
The I/F box is required to connect the SSAS alert unit to the FELCOM 12.
The I/F box is connected to the communication unit with a 5 m cable (17JE-573-10 harness).
Accordingly, locate the interface within 5 m of the communication unit.
Keep the following compass safe distances in mind when choosing the mounting location:
Standard compass: 0.65 m
Steering compass: 0.45 m
1. Unfasten four screws to remove the cover.
2. Use four self-tapping screws (3X10, supplied) to fix the unit to the mounting location.
3. If the cable is led in from the rear of the unit, change the clamp location as follows:
a) Unfasten two screws to remove the clamp.
b) Turn the clamp 90 degrees.
c) Fasten the clamp.
Unfasten two screws.
Turn
Fasten clamp with two screws.
Clamp
4. Pass the cable through the clamp and connect it to the terminal board, referring to the
interconnection diagram.

8
2.1.3 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.
Standard compass: 0.70 m
Steering compass: 0.45 m
Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
Rotate
Fasten three screws.
Clamp
4. Run the cable thru one of the cable entrances and connect it to terminal board.

9
5. Attach the switch cover as shown below. Note that the cover may be turned 180°to
change cover opening direction.
Switch cover
Press here and hold down for five seconds.
Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-7201-1 100-317-931 1
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-802-080 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws
(supplied).
4. Attach switch cover as shown above.

10
2.2 Wiring
2.2.1 Junction box (for FELCOM 16)
Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten
four screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.
For connection, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view
of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P
cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the
junction box.
Cover
Terminal
board
Communication
Unit
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
Core 7 mm
1
2
3
Vcc
GND
TD/RD-A
TD/RD-B
NC
TD-A(NAV)
TD-B(NAV)
RD-A(NAV)
RD-B(NAV)
GND
DMC OUT-H
DMC OUT-C
DMC IN-H
DMC IN-C
DMC CTR
IC-305/306
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Cable clamp
(top)
Note 1: Do not insert the cable too
deeply, to prevent pinching the sheath.
Note 2: Pull each cable slightly to con-
firm that they are in their holes securely.
90mm15mm 7mm
16S0344
Fold back braided shield onto
sheath and fix by cable clamp.
Cable clamp Cable clamp
(bottom)
Junction box IC-315

11
2.2.2 I/F box IC-312 (for FELCOM 12)
FELCOM 12 is connected to the SSAS Alert Unit via the I/F Box IC-312.
For detailed wiring refer to the interconnection diagram at the back of this manual.
15 mm 40 mm
Cut and tape
unused wires
to prevent short.
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
Twist shield.
Clamp for cable
TTYCS-4 (or equivalent)
Clamp for cable
CO-SPEVV-SB-C 0.2X5P
Conductor
S = 0.75 mm
φ= 1.11 mm
2
Armor
Shield
Sheath
Sectional view of cable TTYCS-4
16P0231
123456
Cable from
SSAS Alert Unit
Communication Unit
(rear view)
17JE-573-10 Harness (5 m)
24 VDC
MJ-A3SPF0016-035 (3.5 m)
BUZZER
DMC2DMC1
ANT
BREAKER
24VDC
DTE 1 DTE 2
DATA
NMEA
OR
Wiring I/F box IC-312

12
2.2.3 SSAS alert unit
Three SSAS alert units can be connected. For wiring, see the illustrations below and the
interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15) and
the communication unit (FELCOM 16/FELCOM 12), the wiring of the SSAS is monitored
and if in error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the
ERROR lamp (FELCOM 16) flashes.
Junction
Box
IC-307
(No.1) IC-307
(No. 2) IC-307
(No. 3)
Connect wiring to the terminal board 16P0229 inside the SSAS unit. To differentiate
between units in case of multiple unit installation, change jumper block settings as shown
below, in accordance with how many units are installed.
IC-307
Clamp for cable
CO-SPEVV-SB-C
0.2x5P
15 mm 40 mm 10 mm
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
Cut and tape
unused wires
to prevent short.
Twist shield.
IC-307
Two IC-307: No. 2
Three IC-307: No. 3 Two IC-307: No. 1
Three IC-307: No. 1 and No. 2
Clamp for cable
TTYCS-4
or equivalent
Jumper settings for two IC-307
JP1
JP2
No.1 unit* No. 2 unit No. 3 unit
Yes
Jumper Unit
Yes
No No
Jumper settings for three IC-307
Yes
No
JP1
JP2
No.1 unit*
Jumper Unit
Yes
No
No. 2 unit*
Yes
No
No. 1 unit: Unit with two cables connnected to it.
No. 2 unit: Unit with one cable connnected to it. No. 1 and No. 2 units: Units with two cables connnected to them.
No. 3 unit: Unit with one cable connnected to it.
*: Default
setting
16P0229
12345
6
16P0229
12345
6
JP2
JP1
JP2
JP1
Conductor
S = 0.75 mm
φ= 1.11 mm
2
Sectional view of cable TTYCS-4
Armor
Shield
Sheath
f = 16.3
mm
Cable Fabrication
Wiring inside the SSAS alert unit

13
2.3 Initial Settings
Set up the SSAS as follows:
1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
Enter JOB No. :
FELCOM 15/FELCOM 16 FELCOM 12
3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press
the [Enter] key. The prompt PASSWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then,
the item Main Menu is displayed in reverse video.
5. Press [1], [Enter], [1], [Enter]. One of the following windows appears.
FELCOM 16
FELCOM 15
[ SSAS I/F (IC-312) ]
1. DTE2 Port
2. DATA Port
3. OFF E: Exit
Enter No.:
FELCOM 12
[ DMC ]
1. SSAS(IC-307)
2. DMC
3. OFF
4: SSAS(Momentary SW) E: Exit
Enter No.:
[ SSAS ]
1. ON(IC-307)
2. OFF
3: Momentary SW (for USCG)
E: Exit
Enter No.:
6. FELCOM 15/FELCOM 16: Press [1], [Enter]. This enables the SSAS functions.
FELCOM 12: Choose the port where the SSAS unit is connected and then press the
[Enter] key.
7. Press the [Esc] key several times to close the menu.
Note: Test the SSAS button and SSAS report for proper operation, referring to paragraphs
3.4 and 3.5, respectively.

14
3. OPERATION
3.1 Operation Mode
There are two menu operating modes:
Normal mode: Menus other than SSAS-related menus are displayed.
SSAS manager mode: The mode is activated by the password entered by the ship’s
captain or authorized personnel. The indication “SSAS Manager
Mode” is shown at the top of the screen when this mode is
activated, and it is flashing on the FELCOM 15/FELCOM 16. All
SSAS-related menus are available. Transmission of the SSAS
report may be cancelled in this mode. The equipment starts up in
the normal mode, regardless of the mode in use when the power is
turned off.
3.1.1 Changing the password
The default password is “ship security alert”. Ship’s captain or authorized personnel may
change the password as follows:
1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
Enter JOB No. :
FELCOM 15/FELCOM 16 FELCOM 12
3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then
press the [Enter] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW
PASSWORD appears.
5. Enter new password, using at least six characters, and then press the [Enter] key. The
prompt RETYPE NEW PASSWORD appears.
Note: If less than six characters are entered for the password, the message “Please
use a longer password.” appears. Enter a longer password.
6. Enter new password again and then press the [Enter] key. The message “Password
changed” appears.
7. Press the [Esc] key several times to close the menu.
Note: The SSAS manager mode cannot be unlocked without the proper password.

15
3.1.2 SSAS manager mode
All SSAS-related settings are set in the SSAS manager mode. Do the following to access
this mode.
1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
Command Window
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
Enter JOB No. :
FELCOM 15/FELCOM 16 FELCOM 12
3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode
is activated, and it is flashing on the FELCOM 15/FELCOM 16.
CAUTION
04-04-20 05:37 (UTC)
SSAS Manager Mode enabled.
<Press ESC key to continue>
5. Press the [Esc] key several times to close the menu. This enables the SSAS manager
mode, which allows you to execute the procedure in paragraph 3.2.
Note: Turn the power off and on again whenever changing SSAS-related settings.

16
3.2 Setting SSAS Report Destination and
Message Contents
When the SSAS is activated, the SSAS report is sent according to the addresses (max. 5)
and message content set with SSAS Report 1 – SSAS Report 5 on the SSAS Report menu.
Note 1: The destination and message content of an SSAS report varies according to
Administration. Therefore, set them as requested by ship’s authorities. For
information other than ship’s name, MMSI no. and IMN no., set it manually with
“Other Inf.”
Note 2: The equipment must be in the SSAS manager mode to execute this procedure.
See paragraph 3.1.2.
1. Press the [F5] to open the Reports menu.
Reports
1. Data Report
2. Message Report
3. Data Network ID
4. SSAS Report
2. Press the [4] key to shown the SSAS Report menu.
SSAS Report
1. SSAS Report 1
2. SSAS Report 2
3. SSAS Report 3
4. SSAS Report 4
5. SSAS Report 5
6. Message Contents
3. Press [1], [2], [3], [4] or [5] key as appropriate.
Note: When the button is tested on the FELCOM 12, the test report is sent to the
station having the youngest SSAS report number. Therefore set at SSAS Report
1 the station which is to receive the test report.
SSAS Report
ON
Real+Test
TELEX
02:00 (hh: mm)
Status
Mode
Station Name
Destination Type
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Address
Subject
LES ID
Report Interval
SSAS report window (FELCOM 15/FELCOM 16)

17
4. FELCOM 15/16: Press the [↓] key to choose Mode and then press the [Enter] key.
FELCOM 12: Go to step 6.
Real+Test
Real Only
Test Only
5. Press the [↑] or [↓] key to choose mode desired and then press the [Enter] key.
“Mode” defines what SSAS report(s) a station is to receive:
Real+Test: Actual SSAS report and test SSAS report.
Real Only: Actual SSAS report only.
Test Only: Test SSAS report only.
6. Press the [↓] key to choose Station Name and then press the [Enter] key.
7. Press the [↑] or [↓] key to choose appropriate station and then press the [Enter] key.
You may sort the list by group name, station name or communication type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or
descending order.
Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or
descending order.
Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in
ascending or descending order.
8. Press the [↓] key to choose LES ID and then press the [Enter] key.
9. Press the [↑] or [↓] key to choose LES and then press the [Enter] key.
Note: Change the LES whenever sea area has changed. However, the equipment
automatically searches for an LES with which you can communicate and the
SSAS report is transmitted to that LES.
10.Press the [↓] key to choose Report Interval and then press the [Enter] key.
11.Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]
key.
12.Press the [Esc] key to open the Update window .
SSAS Report
ON
Real+Test
TELEX
02:00 (hh: mm)
Status
Mode
Station Name
Destination Type
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Address
Subject
LES ID
Report Interval
Update
No
Yes
FELCOM 15/ FELCOM 16 SSAS report window w/update window
13.Yes is selected; press the [Enter] key to close the SSAS report window.

18
14.Press the [6] key to display the SSAS Message Contents menu.
SSAS Message Contents
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
34: 44. 46N
135: 21. 26E
02/04/2004 04:31:48 (UTC)
071 deg
00 kt
02/04/2004 04:31:48 (UTC)
Vessel Name :
MMSI :
IMN :
Other Inf. :
LAT:
LON:
Time:
COURSE:
SPEED:
Time:
15.Press the [Enter] key to open the Vessel Name window.
16 Enter vessel’s name and then press the [Enter] key.
17.Press the [↓] key to choose MMSI and then press the [Enter] key.
18.Enter MMSI number and then press the [Enter] key.
19.Press the [↓] key to choose IMN and then press the [Enter] key.
20.Enter IMN and then press the [Enter] key.
21.Press the [↓] key to choose Other Inf. and then press the [Enter] key
22.Enter appropriate message (three lines) and then press the [Enter] key.
Note: To shift between lines, use the [↑] or [↓] key.
23.Press the [Esc] key to open the Update window.
24.Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
25.Press the [Esc] key twice to return to the standby display.
Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.”
Note 2: SSAS report settings may be saved to a floppy disk for backup.
FELCOM 15: [F8], [9], [6] to show the Save/Load window.
FELCOM 16: [F8], [8], [6] to show the Save/Load window.
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
Load from FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
Save to FD
*: Availlable only in SSAS manager mode
("5.SSAS Report" is added in the SSAS
manager mode and item numbers are shifted.)
Note 3: To confirm the settings, follow paragraph 3.5.
Other manuals for felcom15
1
This manual suits for next models
2
Table of contents
Other Furuno Security System manuals

Furuno
Furuno BR-500 User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno BR-1000 User manual

Furuno
Furuno IC-350 User manual

Furuno
Furuno SSAS User manual

Furuno
Furuno BR-1000 User manual

Furuno
Furuno IC-307 User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno FELCOM16 User manual

Furuno
Furuno FB-3101 User manual