Furuno FELCOM16 User manual

PRINTED IN JAPAN
INMARSAT MINI-C MOBILE EARTH STATION
FELCOM16

i
Confirm that the power supply voltage
is compatible with the voltage rating
of the equipment.
Connection to the wrong power supply
can cause fire or equipment damage. The
voltage rating appears on the label at the
rear of the communication unit.
Use the correct fuse.
Use 10 A fuse (defalt setting) for 12 VDC
power supply, or replace the fuse to 5 A
(supplied as spare parts) with 24 VDC.
Use of wrong fuse can result in damage to
the equipment.
Keep the following compass safe
distances.
Standard Steering
Antenna Unit IC-116
Communication Unit IC-216
AC/DC Power Supply Unit
PR-240-CE
SAFETY INSTRUCTIONS
Do not open the equipment
unless totally familiar with
electrical circuits and
service manual.
Only qualified personnel
should work inside the
equipment.
WARNING
Turn off the power at the
mains switchboard before
beginning the installation.
Post a sign near the switch
to indicate it should not be
turned on while the equip-
ment is being installed.
Fire, electrical shock or
serious injury can result if the
power is left on or is applied
while the eqiuipment is being
installed.
ELECTRICAL
SHOCK
HAZARD
0.3 m 0.3 m
0.3 m 0.3 m
0.9 m 0.6 m
Do not approach the ra-
dome closer than 60 cm
when it is transmitting.
Microwave radiation can
cause severe injury or illness.
Radiation level:
10 W/m at 60 cm
2
CAUTION
Attach securely protection
earth to the ship's body.
The protection earth is required
to the power supply to prevent
electrical shock

ii
TABLE OF CONTENTS
EQUIPMENT LISTS.............................................................................................iii
SYSTEM CONFIGURATION................................................................................ iv
1. MOUNTING THE UNIT .....................................................................................1
1.1Antenna Unit....................................................................................................................1
1.2 Communication Unit........................................................................................................7
1.3AC/DC Power Supply Unit PR-240-CE (option) ...............................................................7
2. WIRING ............................................................................................................. 8
2.1Antenna Cable Connector at the Terminal Unit ................................................................9
3. SETTINGS AFTER THE INSTALLATION....................................................... 11
3.1 Installing software..........................................................................................................11
3.2 Setting the IMN (Inmarsat Mobile No.)...........................................................................15
4. CHANGING SHIP’S MAINS SPECIFICATIONS.............................................12
PACKING LISTS ............................................................................................... A-1
OUTLINE DRAWINGS...................................................................................... D-1
INTERCONNECTION DIAGRAM ......................................................................S-1

iii
EQUIPMENT LISTS
Standard Supply
Name Type Code No. Qty Remarks
Antenna Unit IC-116 - 1
Communication Unit IC-216 - 1
Junction Box* IC-315 - 1
w/CP16-02501
SSAS Alert Unit* IC-307 - 2
w/CP16-03101, FP16-00901
CP16-02101 004-439-060 For 15/30 m antenna cable**
CP16-02111 004-439-070 For 50 m antenna cable**
CP16-02121 004-439-080
1 set For 100 m antenna cable**
TP58A15W-RG58 000-146-252 15 m antenna cable
TP5FBAW-5DFBB 000-146-250 30 m antenna cable
8D-FB-CV 000-117-599 50 m antenna cable
12D-SFA-CV 000-138-866 100 m antenna cable
Installation Materials*
CP16-02401 004-439-540
1
For communication unit**
Accessories* FP16-00700 004-439-550 1 set FD-ROM, FD (FP16-00601)**
Spare Parts* SP16-01401 004-439-530 1 set Fuse
*: SSAS Specification only.
**: See packing lists at the back of this manual.
Optional Supply
Name Type Code No. Qty Remarks
Cable assy 17JE-573-10 000-127-108 1 For PC connecting
AC/DC Power Supply Unit PR-240-CE - 1 set w/CP24-00151**
000-560-452 For junction box, 10m
000-103-868 For junction box, 20m
000-103-869 For junction box, 30m
000-132-829 For junction box, 40m
5-pair cable CO-SPEVV-
SB-C 0.2x5P
000-132-828
1
For junction box, 50m
SSASAlert Unit IC-307 000-043-473 1 w/CP16-03101, FP16-00901
Flush Mount Kit OP16-28 004-448-010 1 For SSAS alert unit

iv
SYSTEM CONFIGURATION
Antenna Unit Exposed to Weather
Communication Unit Protected from Weather
Other Units Protected from Weather
PERSONAL
COMPUTER
(PC/AT compatible)
ANTENNA
UNIT
IC-116
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
POWER SUPPLY
100/115/220/230 VAC
1φ, 50/60 Hz
: Standard
: Option
: Local Supply
POWER SUPPLY
12-24 VDC
AC-DC
Power Supply
PR-240-CE
POWER I
O
INMARSAT MINI-C MOBILE EARTH STATION
FURUNO
POWER
LOGIN
TX
ERROR
PRINTER
JUNCTION BOX
IC-315
SSAS ALERT UNIT*
IC-307
SSAS ALERT UNIT*
IC-307
*: At least two SSAS Alert Units are required.
CATEGORY OF UNITS
(Max. 3 units)

1
1. MOUNTING THE UNIT
1.1 Antenna Unit
Mounting Location
• Mount the omnidirectional antenna unit high atop a mast clear of stays and the turning
diameter of a radar antenna. The ideal mounting location would be where no obstacle
appears in the fore and aft directions down to -5º and down to -15º in the port and
starboard directions. This concept is illustrated in the figure below. Shadow sector of the
antenna mast, whip antenna, etc. should be within 2 degrees at one meter from the
antenna unit.
ANTENNA UNIT
5
515
15
Antenna unit mounting location
• If both Inmarsat-Aor B ship earth stations are installed, separate the Inmarsat-A/B
antenna at least 8 m.
• Separate the antenna unit from an S-band radar as follows:
HORIZONTAL LINE
Install above this line
PROHIBITED
ZONE
1.5 m
5 m
15
2 m
S-band radar
INSTALLTION
ZONE
2 m
S-band radar and installation area

1. MOUNTING THE UNIT
2
• The allowable vibration level as specified by Inmarsat is as shown in the table below.
Allowable vibration level
Frequency Level
2 to 10 Hz 2.54 mm Peak Amplitude
10 to 100 Hz 9.8 m/s² Peak Acceleration
• Avoid the location near funnels and stacks; smoke and soot on the radome can lower
signal level.
• Separate the antenna unit 5 m from HF, VHF or 27 MHz antenna.
Mounting
Fifteen, 30, 50 or 100 m antenna cable is available. Fifteen and 30 m cable has connectors
on both ends, and one connector for 50/100 m cable. Do not shorten these cables to
prevent interference. To mount the antenna unit, an exclusive pipe is necessary.
Locally prepare an antenna mast with a ground stud (M6 stainless steel bolt welded to
antenna mast) and mounting pipe with threads and plate (See the outline drawing of the
mounting plate shown below.) Weld the mounting pipe to the antenna mast.
The distance between the stud and the earth terminal on the antenna unit should be within
340 mm, which also is the length of the supplied ground wire.
Mounting pipe and antenna mast

1. MOUNTING THE UNIT
3
For 15 or 30 m cable
1. Apply silicone sealant (local supply) to the threads of the pipe.
2. Unscrew three screws to remove the antenna base from the antenna unit.
3. Pass the antenna cable through the pipe, antenna base in order.
4. Insert the cable protector (supplied) into the slot at the bottom of antenna base.
5. Screw the antenna base onto the antenna pipe by rotating the antenna base.
6. Pass the antenna cable through the shrink tube (supplied).
7. Attach the antenna cable to the connector at the bottom of the antenna unit (upper).
8. Slide up the shrink tube until it touches the bottom of the antenna unit (upper).
9. Heat the above shrink tube, and then apply silicone sealant around the upper edge of
the tube. Also wind self-bonding tape around the lower edge of the shrink tube and then
wrap vinyl tape over self-bonding tape.
Note: Between the bottom of the antenna unit (upper) and the end of the taping should be
less than 50 mm.
Antenna unit, passing the cable through the pipe

1. MOUNTING THE UNIT
4
10.Wrap self-bonding tape around the connection of antenna base and pipe, and then wind
vinyl tape over self-bonding tape.
11.Remount the antenna unit (upper) on the antenna base. (Torque: 2.6 N·m ± 10%)
12.Fix the ground wire RW-4747 (supplied) between the ground terminal on the antenna
unit and the ship’s ground point.
Mounting
13.Apply silicone sealant (supplied) to the ground terminal and three screws at the bottom
of antenna base.
14.Fix the antenna cable to the mast with a cable tie (local supply).

1. MOUNTING THE UNIT
5
For 50 or 100 m cable
1. Apply silicone sealant (local supply) to the threads of the pipe.
2. Unscrew three screws to remove the antenna base from the antenna unit.
3. Pass the cable assy TPA5FB0.3NJ5FBA-5DFB (supplied, 300 mm) through the shrink
tube (supplied).
4. Attach the above cable assy to the connector at the bottom of the antenna unit (upper).
5. Slide up the shrink tube until it touches the bottom of the antenna unit (upper).
6. Heat the shrink tube, and then apply silicone sealant around the upper edge of the tube,
also wind self-bonding tape around the lower edge of the shrink tube and then wrap
vinyl tape over self-bonding tape.
Note: Between the bottom of the antenna unit (upper) and the end of the taping should be
less than 50 mm.
7. Insert the cable protector (supplied) in to the slot at the bottom of the antenna base.
8. Pass the antenna cable through the pipe, antenna base in order.
When laying the cable along side the pipe, put the cable aside to pass through the projection
in the antenna base. See [A] in the figure shown below.
Waterproofing
9. Remount the antenna unit (upper) on the antenna base. (Torque: 2.6 N·m ± 10%)
10.Screw the antenna unit onto the antenna pipe by rotating the antenna unit.
11.Wind self-bonding tape (supplied) at the connection of antenna base and pipe, and then
wrap vinyl tape over self-bonding tape.

1. MOUNTING THE UNIT
6
12.Fix the ground wire RW-4747 (supplied) between the ground terminal on the antenna
unit and the ground stud on the mast.
13.Connect the antenna cable (50 or 100 m) and cable assy (attached at step 4).
14.Wrap the connector with self-bonding tape and then vinyl tape. Bind the cable end with
a cable tie (local supply).
15.Fix the cable to the mast with cable tie (local supply).
Mounting
Waterproofing

1. MOUNTING THE UNIT
7
1.2 Communication Unit
Mounting
Select the following place to mount the communication unit.
• Provide sufficient ventilation.
• For maintenance and checking purpose, leave sufficient space at the sides and rear of
the unit.
Use two tapping screws (4x40, supplied) to fix the communication unit. You can insert
screws from the top and bottom side of the communication unit for bulkhead mounting.
After the screwing, attach the cosmetic caps (2 pcs, supplied) to fixing holes to cover the
screw head.
Communication unit, dimensions
1.3 AC/DC Power Supply Unit PR-240-CE (option)
Fix the unit on a table with four tapping screws (4x16).
272 + 1
100 + 1
4 - 6
AC/DC power supply unit, dimensions

8
2. WIRING
Power supply
12-24 VDC
1.2 m
Copper strap
Ground wire
RW-4747
TP58A15W-RG58, 15 m
TP5FBAW-5DFBB, 30 m
0.34 m
8D-FB-CV, 50 m
12D-SFA-CV, 100 m
For 50 or 100m antenna cable
TNCP-NJ
Cable assy
TPA5FB0.3NJ5FBA-5DFB
0.3 m
Connector N-P-12DSFA
N-P-8DFB
(supplied, local arrange)
17JE-573-10
(5 m, option)
P16-6-3.5, 3.5m
PC
This unit is shipped with 10 A fuse.
Replace fuse with 5 A when using
the equipment with the power supply
24 VDC .
And then, attach a label for 5 A to the
fuse cover on power cable.
Use of wrong fuse can result in damage
to the equipment.
CAUTION
Wiring of FELCOM 16

2. WIRING
9
2.1 Antenna Cable Connector at the Terminal Unit
8D-FB-CV (50 m)
Outer Sheath
Armor Inner Sheath Shield
Dimensions in millimeters.
50 30
Cover with heat-shrink tubing and heat.
30 10
Clamp
Nut Gasket
(reddish
brown)
Clamp
Trim shield here.
Aluminum Foil
Insulator
Trim aluminum
tape foil here.
1
5
Pin
Shell
Clamp Nut
Solder through
the hole.
Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.
Remove insulator and core by 10 mm.
Twist shield end.
Slip on clamp nut, gasket and clamp as shown
left.
Fold back shield over clamp and trim.
Cut aluminum foil at four places, 90 from one
another.
Fold back aluminum tape foil onto shield and trim.
Expose the insulator by 1 mm.
Expose the insulator by 5 mm.
Slip the pin onto the conductor. Solder them
together through the hole on the pin.
Insert the pin into the shell. Screw the clamp
nut into the shell.
(Tighten by turning the clamp nut. Do not
tighten by turning the shell.)
How to fabricate antenna cable 8D-FB-CV (50 m)

2. WIRING
10
12D-SFA-CV (100)
Outer Sheath
Armor Inner Sheath Shield
Dimensions in millimeters.
80 12
Nut
Washer Gasket Clamp
1.8
4.5
Clamp Nut Pin
Solder through
the hole.
Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.
Twist shield end.
Slip on clamp nut, gasket and clamp as shown left.
Expose the insulator by 1.8 mm.
Expose the core by 4.5 mm.
Slip the pin onto the conductor. Solder them
together through the hole on the pin.
Insert the pin into the shell. Screw the clamp
nut into the shell.
(Tighten by turning the clamp nut. Do not
tighten by turning the shell.)
How to fabricate antenna cable 12D-SFA-CV

11
3. SETTINGS AFTER THE
INSTALLATION
3.1 Installing software
After installing the equipment, install the FELCOM 16 software (F16PC) in the PC as
follows:
1. Turn on the PC.
2. Set FD-ROM in floppy disk drive.
3. Click the icon of “SETUP.EXE” in the floppy disk. The setup procedure begins, showing
the welcome dialog box.
16
16
Welcome dialog box

3. SETTINGS AFTER THE INSTALLATION
12
4. Click the [Next] button.
16
16
16
Choose destination location dialog box
5. Click the [Next] button.
16
Select program folder dialog box

3. SETTINGS AFTER THE INSTALLATION
13
6. Click the [Next] button.
16
Start copying files dialog box
7. Click the [Next] button and the installation begins. When the installation is completed,
the FELCOM 16 dialog box appears.
FELCOM 16 dialog box

3. SETTINGS AFTER THE INSTALLATION
14
8. Click the Close button ( )at the top right corner of the dialog box. The “Setup
Complete” dialog box appears.
Setup complete dialog box
Note:If you want to launch the program file now check the box next to “Yes, Launch the
program file.” The application will launch after the completion of step 9.
9. Click the [Finish] button. The FELCOM 16 PC application shortcut is created on the
desktop.
F16PC
Note: To uninstall the F16 application see the operator’s manual for the PC.

3. SETTINGS AFTER THE INSTALLATION
15
3.2 Setting the IMN (Inmarsat Mobile No.)
Set your IMN (Inmarsat Mobile No.) using the and PC as below.
1. Power on the communication unit and PC in order.
2. Double click [F16PC] on the screen to start the program.
3. Press the [F8] function key to show the Setup menu.
Setup
File Edit Transmit EGC Reports Logs Options Setup Position StopAlarm
1. System Setup
2. Editor Setup
3. Terminal Setup
4. EGC Setup
5. Auto Mode Setup
6. E-Mail Setup
7. Directories
8. Configuration
Setup menu
4. Press [1] key to display the System Setup menu.
Setup
9. Configuration
System Setup
01:53 02-02-25 (YY-MM-DD)
INMARSAT-C
INT
INT
INT
INT
System Date & Time
IMN
MES Operation Mode
Nav Port
Active Port
Message Output Port
EGC Output Port
Network Setup
Command Window
System Setup menu
5. Confirm that the IMN is selected, and then press the [Enter] key.
The entering field appears.
6. Key in your IMN.
7. Press the [Enter] key.
8. Press the [Esc] key to escape from the entering field.
9. Press the [Enter] key.
To clear the IMN, press [I] [M] [N] in order while pressing the [Alt] key down at step 6.
When using the FELCOM 16 for VMS (Vessel Monitoring System), DNID (Data Network ID)
has to be downloaded via the LES (Land Earth Station). This arrangement is normally done
by authority of VMS.
Table of contents
Other Furuno Security System manuals

Furuno
Furuno BR-1000 User manual

Furuno
Furuno IC-350 User manual

Furuno
Furuno felcom15 User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno FB-3101 User manual

Furuno
Furuno IC-307 User manual

Furuno
Furuno SSAS User manual

Furuno
Furuno BR-500 User manual

Furuno
Furuno BR-1000 User manual