Gima 24402 User manual

PROFESSIONAL MEDICAL PRODUCTS
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
PETTINE ELETTRICO ANTI PIDOCCHI
ELECTRIC LICE COMB
PEIGNE ÉLECTRIQUE ANTI-POUX
PEINE ANTIPIOJO ELÉCTRICO
Manuale utente - User manual
Notice d’utilisation - Manual del usuario
Gima S.p.A.
Via Marconi, 1
20060 Gessate (MI) Italy
Mde in China
ATTENZIONE: Gli operatori devono leggere
e capire completamente questo manuale
prima di utilizzare il prodotto.
ATTENTION: The operators must carefully
read and completely understand
the present manual before using the product.
AVIS: Les opérateurs doivent lire et bien comprendre
ce manuel avant d’utiliser le produit.
ATENCIÓN: Los operadores tienen que leer
y entender completamente este manual
antes de utilizar el producto.
M24402-M-Rev.2-04.19
24402
60°C
-20°C
%
95%

8
INTEND USE
The removal of the head lice and their eggs (nits) from hair.
HOW IT WORKS
• It has been specially designed to generate an electric charge of 160-250V , which immediately
zaps lice when contact, but imperceptible to humans and completely safe to use.
• The electric lice comb is powered by two AAA batteries 1.5 V which generates 80-250V.
• The integrated circuit in the comb generates a periodic oscillating square wave when lice
contact with teeth of the comb.
• The electrical discharge is triggered automatically, and lice are destroyed on the spot.
• The low current generated by the battery of 1.5 V ensures the complete safety of electric
comb for use on people.
• Totally painless and safe for hair and scalp.
• Low energy consumption.
•
Efcient and easy to use, especially ideal for use on young children and those with sensitive scalp.
• Since there is no active substance involved in the use of comb, it may be used several times
and as often as necessary.
RECOMMENDATIONS FOR EFFECTIVE USE
• You must use the comb only on dry hair.
• Ensure that the electric comb does not get humid or wet during use.
• We recommend that you use a repellent treatment (cream, shampoo, etc..) after using the
electric comb, in order to avoid a new outbreak.
PRECAUTIONS BEFORE USE
For optimal use of electric lice comb is recommended to follow these instructions and observe
the following safety points:
• The use of electric lice comb is not recommended in the following cases:
• Do not use on people with pacemakers.
• Do not use on people who have epilepsy or heart disease.
• Do not use on damp or wet hair.
• Do not leave the comb in reach of children.
• Do not use the comb on another family member without rst disinfecting it.
• Disinfect the electric comb and its teeth after each use, using a cloth dampened in a solution
of 70% alcohol (remove the battery during cleaning of the electronic comb). Wait until it is
completely dry before using it again.
• Do not use the comb if the teeth are deformed, as this may cause a short circuit in the comb.
• Use electric comb only for the purpose for which it was designed, as described in the instruc-
tion manual.
Place the protective cover back on after use in order to protect the teeth
SAFETY INSTRUCTION
For your safety, it is recommended that you read this User Guide very carefully, and comply with
the following instruction.
ENGLISH

9
• Using the appliance only as intended in accordance with the instructions provided in this
guide.
• This electric device is not a toy, avoid the reach of child.
• Children under the age of 3, are not suited for this appliance.
• Children should be supervised by an adult while using this electric device.
• Consult the physician before using this unit, if you have a pacemaker, articial limbs or any
electronic implant.
• Do not operate this unit close to a mobile telephone, a micro wave oven, or a television set (
away more than 1 meter).
• People who suffer from epilepsy or heart disease are not recommended to use this appliance.
• Do not use this unit on damp hair or any undo knots or braids.
• Avoid cracked or dry skin, or direct contact with your ears, eyes and mouth.
• Avoid the direct exposure of sunlight, and upon any hot surface.
• Keep the unit away from moisture, or any liquid.
• Do not use the unit, if the housing or comb is damaged, if the unit does not function properly
or if it has been immersed by liquid.
• Prevent accident or damage to the unit by keeping the unit away from clothing, bristles, wires,
strings, shoelaces, threads etc.
• Always switch off the unit when not in use.
• Remove the battery if the appliance is not to be used for extended period.
INTRODUCTION
Head lice are tiny, wingless insects. When fully grown, they’re similar in size to a sesame seed.
Because they can’t survive the cold, they cling to our hair, keeping close to the warmth of our
heads.
Head lice are harmless – though they can cause your children to get an itchy scalp. Head lice
have been making a nuisance of themselves for thousands of years. Fortunately, getting rid of
them nowadays need only take a ten minutes treatment time!
Gima electric lice comb is one viable option to consider in the quest of eradicating head lice so
they will stop spreading through your family member’s hair and scalp. It is certainly no secret
that an infestation of lice can make life difcult for everyone in the household, but thanks to
modern technology -- an electric lice comb, the process of getting rid of these pests can be
just a lot easier.
SPECIAL FEATURES
Gima lice comb uniquely can not only dispel but also efciently kill head lice and nits by quickly,
increasing electrical voltage of 160~250 Volts, which is harmless to human.
Comb activity is indicated by an audible signal, which provides different sounds: one sound
per three seconds indicates the functional unit (80-140V); the short, sharp beep three times in a
second indicates the contact with the intruder (160-250V).
ENGLISH

10
ENGLISH
Automatic switch off function
After 3 minutes not in use, the unit will switch off automatically for extending the battery life.
When detecting low battery voltage, the unit will turn off au-
tomati- cally after 7 short beeps and LED ash indication.
Impeccable design for containing the accessories inside the
main appliance, portable and suitable for travel.
DESCRIPTION OF THE APPLIANCE
AND SUPPLIED ACCESSORIES
1. On/Off switch (press button)
2. Protective cover
3. Electric comb
4. Lid of the battery compartment
5.Cleaning brush
6. Battery compartment
INSTALLATION OF THE BATTERIES
Open the lid protecting the battery by lifting the point “4“, the
lid connects the housing to avoid missing.
Insert two AAA batteries, observe the proper polarity (+/-) of
the batteries as indicated on the batteries and on the battery
compartment. A polarity error can damage your appliance and
compromise the guarantee.
OPERATION
1. Press On/Off switch button “1” for two seconds to operate the appliance. LED light will power
on, buzzer will beep three seconds long to indicate the operation.
2.Use the appliance as normal comb. Please use the unit on dry hair. Undo the knots or braids
before using the unit.
3.While operating the unit, LED lights will be on and also the buzzer will sound every three sec-
onds.
4.The buzzer will have a short and quick humming sound, LED indicator ashes quickly when
the teeth come in contact a louse or egg.
4-1. The voltage will kill lice and eggs.
4-2. Be sure to clean the comb with the cleaning brush thoroughly after every usage.
5.After use, remember to switch off the unit and clean the comb with cleaning brush thoroughly,
put the protective cap “2” back on the unit during storage.

11 ENGLISH
CLEANING AND MAINTENANCE
1.Remove the batteries before cleaning the appliance.
2.Avoid using any liquid, strong detergents to scrub the unit.
3.For the housing, use a dry, soft paper or fabric cloth to clean. For teeth, use the accessory of
cleaning brush.
4.Make sure no water gets into the unit while cleaning, and never immerse the unit in water.
5.The storage should be in a clean, dry and cool, ventilated location.
6.Direct exposure to sunlight will damage the unit.
BATTERY DISPOSAL
1. Please dispose the product and battery separately.
2. The product and batteries should not be disposed with household waste.
3. Please follow local waste/ recycling/ battery disposal
TECHNICAL SPECIFICATIONS
STORAGE AND TRANSPORTATION ENVIRONMENT
Temperature -20°C to 60°C (-4°F to 140°F)
Humidity < 95% (non-condensing)
Atmospheric Pressure 525mmHg to 795mmHg (700 to 1060hPa)
OPERATING ENVIRONMENT
Temperature 5°C to 40°C (41°F to 104°F)
Humidity < 95% (non-condensing)
Atmospheric Pressure 525mmHg to 795mmHg (700 to 1060hPa)
Model name 24402
Power supply AAA battery x 2
Export Voltage 80~250 V
Battery life Eight hours in continuous use
Auto switch off Yes
Dimension 177 x 34 x 39 mm
Weight 200g (Battery included)

12
ENGLISH
Disposal: The product must not be disposed of along with other domestic waste.
The users must dispose of this equipment by bringing it to a specic recycling point
for electric and electronic equipment. For further information on recycling points
contact the local authorities, the local recycling center or the shop where the prod-
uct was purchased. If the equipment is not disposed of correctly, nes or penalties
may be applied in accordance with the national legislation and regulations.
GIMA WARRANTY CONDITIONS
Congratulations for purchasing a GIMA product. This product meets high
qualitative standards
both as regards the material and the production. The warranty is valid for 12 months from
the date of supply of GIMA. During the period of validity of the warranty, GIMA will repair
and/or replace free of charge all the defected parts due to production reasons. Labor costs
and personnel traveling expenses and packaging not included.
All components subject to wear are not included in the warranty. The repair or replacement
performed during the warranty period shall not extend the warranty. The warranty is void
in the following cases: repairs performed by unauthorized personnel or with non-original
spare parts, defects caused by negligence or incorrect use. GIMA cannot be held respon-
sible for malfunctioning on electronic devices or software due to outside agents such as:
voltage changes, electro-magnetic elds, radio interferences, etc. The warranty is void if
the above regulations are not observed and if the serial code (if available) has been re-
moved, cancelled or changed. The defected products must be returned only to the dealer
the product was purchased from. Products sent to GIMA will be rejected.
Symbol Description Symbol Description
Product code Lot number
Keep away from sunlight Keep in a cool, dry place
Date of manufacture Manufacturer
Please read instructions
carefully Read instructions carefully
%
Humidity limitation Temperature limitation
Product complies with
European Directive WEEE
Other manuals for 24402
2
This manual suits for next models
1
Table of contents
Other Gima Medical Equipment manuals

Gima
Gima Rescue LIFE User manual

Gima
Gima Sigma User manual

Gima
Gima 27800 User manual

Gima
Gima UTC2 User manual

Gima
Gima SP-20 User manual

Gima
Gima Sigma 31524 Parts list manual

Gima
Gima MG8001-H User manual

Gima
Gima Cardio-A Palm ECG Parts list manual

Gima
Gima A100-4 User manual

Gima
Gima SUPER VEGA BATTERY User manual