Hioki MR8880-20 User manual

MEMORY HiCORDER
Recorders
MR8880-20
CAT III 600 V insulation performance
• Operating temperature range: -10°C to 50°C
• Built to withstand mechanical shocks and vibrations
(ships standard with side protectors)
Simply select what you’d like to measure and follow the on-
screen instructions to select the appropriate settings. The
recorder can be easily configured to measure voltage drops
and power outages.
•
Maximum 600V AC/DC input - no need for a differential probe
• 4 completely isolated channels let you simultaneously record
data on a 3-phase power line plus have one extra channel
Make settings easily with PRESETS
Tough against harsh environments
MEMORY HiCORDER
Capture high- to low-voltage signals in a single device
Rugged, Professional and Ready for the Field

2
CAT III 600 V isolated inputs (4 channels)
Built to withstand harsh environments
The MR8880-20 offers safe, reliable operation featuring CAT III 600 V isolated inputs in a compact yet
durable design that excels at taking measurements in harsh environments.
Shown with optional printer unit.
■ Extensive operating temperature range [-10°C(14°F) to 50°C(122°F)]
Even when operating on battery power, the MR8880
-20
can take measurements from 0°C
(32°F)
to 40°C
(104°F)
.
■ Rugged, damage-resistant design features standard side protectors
that guard the instrument’s case.
■ 4 analog + 8 logic channels
■ Directly input 600 V AC/DC (CAT III) and 300 V AC/DC (CAT IV) input.
Measure up to 2000V DC/1000V AC (CAT II) with the DIFFERENTIAL PROBE
9322 (separate power supply required.)
Direct input and measurement of 3-phase power lines
Don’t let extreme temperatures keep you from taking measurements!
Safe & Reliable Measurement
Shown with optional printer unit.Shown with optional printer unit.
Even when operating on battery power, the MR8880
(32°F)
(104°F)
■
Rugged, damage-resistant design features standard side protectors
Rugged, damage-resistant design features standard side protectors
that guard the instrument’s case.

3
Press the
“PRESETS” key.
Press the “PRESETS” key and
select “Loading settings”
To confi gure the MR8880
-20
, you need only select what you’d like to measure—“Measure a commercial power supply,”
“Monitor a power source for a voltage drop,” etc.—and follow the on-screen instructions to select the appropriate settings.
Press the “PRESETS” key and
select “Basic Guide”
Example: Confi guring the MR8880
-20
to monitor a power source for a voltage drop:
Select “Measurement Guide”
Select “
Voltage drop of power outage, etc.
”
Select what you’d like
to measure with the
cursor keys.
Basic Guide Loading settings
“Voltage drop of power outage, etc” settings screen
Other Convenient Functions
START
• Measure Power Supply on INSTNT
• Measure Power Supply on RMS
• Voltage drop of power outage, etc.
• Save data to media
Use • Not Use
• Basic Guide
• Measurement Guide
• Load Set.
Press the START key
Start mesurement
*Patent pending
1. Select the channel you wish to use.
Select the power line voltage.
Select the frequency.
Select the threshold.
Select the high-speed or real-time function.
(The auto-range settings can be enabled when using the high-speed function.)
Make the necessary settings in accordance
with information provided by the guide.
(Settings can be confi gured while checking the measurement waveform.)
Select the source from which to load settings.
(Memory / CF card / USB memory)
Select the settings fi le to load from a list of settings stored on the selected
source and press the “Load” key.
Start measurement Start measurement
Settings are as Easy as 1-2-3 with PRESETS*
100V • 200V
50Hz • 60Hz
90/85/80/75/70/65/60 V
25ms/50ms/100ms/200ms
Record • Do not record
only once • Repeatedly
• Do not save
•
Save to CF card in Binary Format
•
Save to CF card in
Text Format
•
Save to USB memory in Binary Format
•
Save to USB memory in
Text Format
4. Select whether to repeat
measurement.
Select the desired save settings.
2. Select the recording length.
3. Save pre-triggered waveforms.
Press START to
begin measuring.
'10-10-21 14:58:08

4
■ Recording Capacity
• Maximum recording time is inversely proportional to number of recording channels.
• Because the actual capacity of a CF card is less than that indicated, and because the header portion of waveform
files is not included in capacity calculations, expect actual maximum times to be about 90% of those in the table.
• "★" exceeds 1 year.
• Proper operation is not guaranteed for extended recording periods (one year or longer). This type of operation
impacts the product’s warranty period and service life.
Investigate why your office’s power
supply occasionally exhibits instability.
Check for fluctuations in low-voltage
signals such as instrumentation or
sensor output.
Measure the phase voltages for
all three phases of a three-phase
motor simultaneously.
Four channels of isolated
Cat III 600 V input
Thanks to its 14-bit, high-resolution A/D converter and the combination
of a high-sensitivity 5 mV/div range and a 5 Hz filter (for noise rejection),
the MR8880
-20
can deliver stable measurement of sensor output.
The MR8880
-20
is capable of mixed recording of RMS values,
DC voltage, and logic signals, allowing it to simultaneously record
data describing the interrelationships between equipment power
supplies and UPS output and control signals.
The MR8880
-20
provides a turnkey solution for both high-speed measurement at 1 MS/s and long-term
measurement. Its ability to measure everything from high- to low-voltage signals allows it to play an important
role in a variety of measurement scenarios.
■ Recording Time (Internal memory)
All channels (4 analog + 8 logic channels)
Time Axis Range
Sampling Speed
Recording Interval
Max. Recording Time
100ms/DIV 1 MS/s 1 μs 1 s
200ms/DIV 500 kS/s 2 μs 2 s
500ms/DIV 200 kS/s 5 μs 5 s
1ms/DIV 100 kS/s 10 μs 10 s
2ms/DIV 50 kS/s 20 μs 20 s
5ms/DIV 20 kS/s 50 μs 50 s
10ms/DIV 10 kS/s 100 μs 1m 40 s
20ms/DIV 5 kS/s 200 μs 3m 20 s
50ms/DIV 2 kS/s 500 μs 8m 20 s
100ms/DIV 1 kS/s 1 ms 16m 40 s
The maximum recording length is fixed regardless of the number of channels in use.
Measure RMS value fluctuations for a
power line over an extended period of time
Long-term measurement and recording
using the real-time function
Recording
Interval
All channels (4 analog + 8 logic channels), recording waveform (binary) data only
Internal memory
(8MB)
256MB
(9727)
512MB
(9728)
1GB
(9729)
2GB
(9830)
100ms
1m 40s 23m 20s 1h 46m 40s 3h 33m 20s 7h 6m 40s
200ms
3m 20s 1h 46m 40s 3h 33m 20s 7h 6m 40s 14h 13m 20s
500ms
8m 20s 4h 26m 40s 8h 53m 20s 17h 46m 40s 1d 11h 33m 20s
1ms
16m 40s 8h 53m 20s 17h 46m 40s 1d 11h 33m 20s 2d 23h 6m 40s
2ms
33m 20s 17h 46m 40s 1d 11h 33m 20s 2d 23h 6m 40s 5d 22h 13m 20s
5ms
1h 23m 20s 1d 20h 26m 40s 3d 16h 53m 20s 7d 9h 46m 40s 14d 19h 33m 20s
10ms
2h 46m 40s 3d 16h 53m 20s 7d 9h 46m 40s 14d 19h 33m 20s 29d 15h 6m 40s
20ms
5h 33m 20s 7d 9h 46m 40s 14d 19h 33m 20s 29d 15h 6m 40s 59d 6h 13m 20s
50ms
13h 53m 20s 18d 12h 26m 40s 37d 53m 20s 74d 1h 46m 40s 148d 3h 33m 20s
100ms
1d 3h 46m 40s 37d 53m 20s 74d 1h 46m 40s 148d 3h 33m 20s 296d 7h 6m 40s
200ms
2d 7h 33m 20s 74d 1h 46m 40s 148d 3h 33m 20s 296d 7h 6m 40s -
★
-
500ms
5d 18h 53m 20s 185d 4h 26m 40s 370d 8h 53m 20s -
★
- -
★
-
1s
11d 13h 46m 40s 370d 8h 53m 20s -
★
- -
★
- -
★
-
1 min
964d 10h 40m -
★
- -
★
- -
★
- -
★
-
…
l Recording interval of 100 µs to 1 min
l Waveform data is saved directly in a binary format to
a CF card or USB memory.
Measure the instantaneous
waveform at startup or a suddenly
generated abnormal waveform.
High-speed measurement using the high-speed function
l Fastest sampling period of 1 µs (measuring all channels simultaneously)
l Measurement data is recorded in the instrument’s internal memory (1 MW).
1
2
3
4
5
Record RMS values and
instantaneous waveforms
simultaneously.
Example record of an
abnormal waveform
Applications
…
…
…
…
…
Note: Use only HIOKI CF cards that are guaranteed to operate with the HiCORDER for continuous long-term recording.
A waveform recorded using a waveform
judgment trigger. The judgment area can be
displayed simultaneously.
The MR8880-20 can measure the voltages
at different contacts without the need for
a differential probe.

5
l In addition to CF cards, the MR8880-20 can store data on handy USB
memory sticks.
l Data can be saved in real time to external media (at up to 10 kS/s).
l External media can be switched while measurement continues.
If the recording interval is set to 100 µs, media must be swapped outwithin
20 seconds.
l External media is protected in the event of an unexpected power
outage during measurement.
By backing up the internal power supply until processing to save data to the external
media completes, the instrument enables highly reliable data collection.
Example printout
(actual size)
Is the printer easy to use?
Loading recording paper is a snap
thanks to the MR8880-20’s one-touch
loading mechanism.
Can the MR8880-20
withstand the vibrations
in a moving vehicle?
The instrument complies with JIS
automotive vibration standards.
Will the screen be hard
to read while taking
measurements outdoors?
The MR8880-20 features a 5.7-inch TFT color
LCD that offers excellent visibility, even while
taking measurements in an outdoor setting.
The display is even engineered for easy
viewing in the presence of reflections.
What if there’s no power
available in the vehicle
being tested?
A high-capacity battery is available.
Quickly print data on-site.
(Real-time print function: 1s/div
~
)
The MR8880-20 delivers convenient functionality designed to maximize ease of use along with exceptional
performance. See how this instrument can transform your concern and discontent to peace of mind and satisfaction.
Use only HIOKI CF cards, which are manufactured
to strict industrial standards, for long-term storage
of important data.
Note: Operation of non-HIOKI CF cards is not guaranteed
Thanks to its ability to withstand a high
level of vibration, the MR8880
-20
can be
used to collect data in moving vehicles.
Included side protectors further increase
the device’s durability.
The MR8880-20 can be used continuously
for 4 hours on battery power.
Take home data for later
viewing on a computer
Data can be saved directly
to external media.
1
2
3
4
5
Shown with
optional printer unit.
Simply load the recording paper roll and close the cover.
CompactFlash
card USB memory
Functionality and Performance

6
■ Specifications
High-speed function (high speed recording)
Time axis
100μs to 100ms/div, 10 range, resolution: 100 points/div
Sampling period
1/100 of time axis ranges
(minimum sampling period 1 μs,
all channels simultaneously)
Recording length
5 to 10000 divisions fixed (5division steps)
Automatic save
function
Binary data, text data, calculation results, binary + calculation results,
text + calculation results, or NONE
Other save functions
Save and delete function: ON/OFF
Screen settings
Split screen (1, 2, or 4 segments), X-Y waveform compositing (1 screen)
Pre-trigger
Can record data from before the trigger point, 0 to 100 % of
recording length; 13 settings, or user-configured
Waveform scrolling
Backwards scrolling through past waveform data both during and
after measurement
Calculation
functions
Up to four arithmetic operations simultaneously
Average value, effective (RMS) value, peak to peak value,
maximum value, time to maximum value, minimum value, time to
minimum value, period, and frequency, area, X-Y area.
Real-time function (actual time recording)
Recording interval 100μs to 500μs, 1ms to 500ms, 1s to 1min, 19 settings
Display time axis: 10ms to 1day/div, 22 ranges
Real-time printing
(with optional MR9000)
ON/OFF
*Simultaneous printing: Supported when using a time axis slower than 1 s/div.
Recording Time
Continuous save to CF card or USB memory can be set ON/OFF
Envelope mode ON/OFF
Waveform
recording
The last 1 Mwords of data (before measurement was stopped) are
saved in the instrument’s internal memory (when envelope mode is
on, 500 kwords of data).
Real-time save
function
Binary data, text data, calculation results, binary + calculation
results, text + calculation results, or NONE
Other save
functions
Split save: ON/OFF/fixed time
Save and delete: ON/OFF
Eject media: Media can be ejected while saving data in real time.
Event marks
1) Event marks can be input during measurement (up to 100 marks).
2) Can move to waveform before or after an event mark based on
specified event number input.
Trigger function
Repeat recording
Single/Repeat
Trigger timing
High-speed function: Start
Real-time function: Start, Stop, Start & Stop
Trigger conditions
AND/OR supported for all trigger sources
Trigger source
Trigger sources can be selected for each channel. Instrument enters
free-run mode when all trigger sources are off.
1) Analog input CH1 - CH4
2) Logic input LA1 - LA4, LB1 - LB4 (4ch × 2 probes)
3) External trigger
4) Interval trigger: Fixed-time recording for specified measurement
interval (month/day/hours/minutes/seconds)
Trigger types
1) Level 2) In 3) Out
4) Voltage drop
(High-speed function)
: For AC 50/60 Hz power lines
5)
Waveform judgment
(High-speed function)
: For AC 50/60 Hz power lines
6) Logic 7) External: Rising edge/falling edge
Level setting resolution
0.1 % f.s. (f.s.=10 div)
Trigger filter
High-speed function: 7 settings from 10 to 1000 samples or OFF
Real-time function: ON/OFF
Trigger output
Open collector (5 V output, active Low)
Analog input
(Accuracy defined at 23° ±5°C, 80% rh or less, for measurements taken following zero adjustment 30 minutes
after instrument is turned on; accuracy guarantee of 1 year; product guarantee of 1 year)
Measurement functions
4-channel voltage measurement; switchable between instantaneous
value (waveform) and RMS value
Input connectors
Isolated BNC connector (input impedance 1 MΩ, input capacitance 7 pF)
Max. rated voltage
to earth
600 V AC, DC CAT III / 300 V AC, DC CAT IV
(with input isolated from the unit, the maximum voltage that can be applied
between input channel and chassis and between input channels without damage)
Measurement
range
10 mV to 100 V/div, 13 ranges, full scale: 10 div, AC voltage that can be
measured and displayed using high-speed function: 600 Vrms
Low-pass filter: 5 Hz/50 Hz/500 Hz/5 kHz
Measurement resolution
1/640 of measurement range (using 14-bit A/D conversion, at
×
1)
Highest sampling rate
1 MS/s (simultaneous sampling in 4 channels)
Instantaneous value
measurement accuracy
±0.5% f.s. (after zero-adjust)
RMS measurement
RMS accuracy: ±1.5% f.s. (DC, 30Hz to 1kHz) ±3% f.s. (1kHz to 10kHz)
Response time: 300ms (rising edge 0 to 90% of full scale with filter off)
Crest factor: 2
Frequency characteristics
DC to 100 kHz ±3dB
Input coupling
DC/GND
Max. rated voltage
between terminals
600 V AC, DC
(maximum voltage which when applied to between input
terminals does not damage them)
Basic specications (accuracy guaranteed for 1 year)
Measurement
functions
High-speed function (high speed recording)
Real-time function (actual time recording)
Number of
channels
4 analog + 8 logic
Isolated analog channels, isolated input and outputs, logic has common GND.
Maximum sampling rate
1Msamples/s (1 μs cycle, all channels simultaneously)
Memory capacity
14bit × 1 M words/ch (1 word = 2 bytes, not expandible)
External memory
CF card slot × 1 (Up to 2 GB, supports FAT16 and FAT32 formats)
USB memoly × 1 (USB 2.0 -A receptacle)
Time accuracy (at 23°C)
Sampling time accuracy: ±0.0005 %, Clock precision: ±3s/day
Backup function
(reference value at 23°C)
Clock and settings: 10 years or more (at 25°C / 77°F)
Waveform backup function: Approx. 40 minutes
• When instrument is powered off at least 5 minutes after being turned on
External control
External trigger input, Trigger output, external start input,
external stop input, status output, ground pin
Interface
USB: 1 port USB 2.0 High Speed mini-B receptacle
Functions: Configure settings/perform measurement using communications
commands; transfer file stored in CF/USB memory to computer
(USB drive mode)
Environmental
conditions for use
(no condensation)
Temperature range: -10°C (14°F) to 50°C (122°F)
Humidity range: -10°C (14°F) to 40°C (104°F), 80% rh or less
40°C (104°F) to 45°C (113°F), 60% rh or less
45°C (113°F) to 50°C (122°F), 50% rh or less
When powered by BATTERY PACK Z1000:
0°C (32°F) to 40°C (104°F), 80% rh or less
When recharging the Z1000: 10°C (50°F) to 40°C (104°F), 80% rh or less
Environmental
conditions for storage
(no condensation)
Temperature range: -20°C (-4°F) to 60°C (140°F)
Humidity range:
80% rh or less (-20°C (-4°F) to (140°F)), 60% rh or less (40°C
(104°F) to 45°C (113°F)), 50% rh or less (45°C (113°F) to 60°C (140°F) )
BATTERY PACK Z1000: -20°C (-4°F) to 40°C (104°F) , 80% rh or less
Compliance
standard
Safety: EN61010 EMC: EN61326, EN61000-3-2, EN61000-3-3
Vibration resistance: JIS D 1601, Type 1: passenger vehicle,
Conditions: equivalent to Type A
Power
requirements
Note: LR6/AA alkaline
batteries are not sufficient
to power the unit when it is
connected with the PRINTER
UNIT MR9000. Use of other
power supplies is required.
(Continuous operating time is given
as a reference value at 23°C.)
1) AC ADAPTER Z1002: 100 to 240V AC (50/60 Hz)
2) BATTERY PACK Z1000: 7.2V DC
Continuous operating time: Approx. 3 hours with backlight on, approx. 3.5
hours with backlight off (AC adapter has priority when both are used)
3)
LR6 (AA)
×
8
Approx. 40 minutes with backlight on while recording data in real time
(when used with AC adapter, AC adapter takes precedence)
4)
10 to 28V DC (using special order cable)
Charging functions
(reference value at 23°C)
Charging time is about 3 hours
(can be charged by connecting the AC adapter while the Z1000 battery pack is attached)
Max. rated power
1) When instrument is powered with the Z1002 AC adapter or an
external DC power supply: 11 VA*
1
, 10 VA*
2
, 40 VA*
3
2) When instrument is powered with the Z1000 battery pack;
9 VA*
1
, 8 VA*
2
, 22 VA*
3
*
1
Real-time data storage, backlight on
*
2
Real-time data storage, backlight off
*
3
Real-time data storage, backlight on, with printer used
Dimensions, mass
(including battery pack)
205 mm (8.07 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D,
1.66 kg (58.6 oz) (printer detached)
303 mm (11.93 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D,
2.16 kg (76.2 oz) (printer attached)
Accessories
AC adapter Z1002 (1), Alkaline battery box (1), Strap (1)
USB cable (1), Application disk (1), Instruction manual (1)
Function
Presets Select from basic measurement guide, example measurement
guide, and commands for loading internally stored settings.
Scaling function
Select decimal or scientific notation for each channel.
1) Scaling ratio: Select scaling ratio, offset value, and units.
2)
Two-point configuration: Set input values, post-scaling values, and units.
3) HIOKI sensor: Set HIOKI clamp-on probe and range value.
4) Output rate setting: Select scaled value per 1 V from a list.
Data protection
Open files are closed before the instrument turns itself off when a
power outage occurs while saving data to recording media.
When powering the instrument with a battery, open files are closed
and access to the media is stopped when remaining battery power
falls below a certain level.
*Valid when at least 5 minutes has elapsed since the instrument was turned on.
Reservation function
Up to 10 measurement start and measurement stop conditions can be set.
Other
Settings can be automatically loaded from internal memory or
media when the instrument is turned on. Up to 10 settings can
be saved in the instrument’s internal memory.
Printer (Printer Unit MR9000 docks onto the main device)
Features
Printer paper one-touch loading, high-speed thermal printing
Printer paper
112 mm (4.4 in) × 18 m (59.06 ft), thermal paper roll (
using 9234)
Recording width: 100 mm, 10 div f.s., 1 div=10 mm (80 dot/div)
Recording speed
Max. 10 mm/s (0.39 inch/s)
(Printing is not supported when using alkaline batteries.)

7
■ Bundled PC Software Specifications
Wave Viewer (Wv) Software (Application disk CD-R, bundled accessory)
Functions
• Quick display of waveform files
• Text conversion: Conversion of binary data files to text
format, with storage in either CSV or space/tab delimited
format. Span specification and data culling available.
• Display format settings: scroll function, enlarge/reduce
display, display CH settings.
• Other: Voltage trace function, jump to cursor/trigger position
function, etc.
Compatible
operating systems
Windows 2000/XP/Vista (32-bit), or Windows 7 (32-bit/64-bit)
LOGIC PROBE 9320-01
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year)
Function
Detection of voltage signal or relay contact signal for High/Low state recording
Input
4 channels (common ground between unit and channels), digital/contact
input, switchable (contact input can detect open-collector signals),
input impedance: 1MΩ (with digital input, 0 to +5V), 500kΩ or more
(with digital input, +5 to +50V), pull-up resistance: 2kΩ (contact input:
internally pulled up to +5V)
Digital input threshold
1.4V/2.5V/4.0V
Contact input
detection resistance
1.5kΩ or higher (open) and 500Ω or lower (short), 3.5kΩ or higher (open)
and 1.5kΩ or lower (short), 25kΩ or higher (open) and 8kΩ or lower (short)
Response speed
500ns or lower
Max. allowable input
0 to +50V DC (the maximum voltage that can be applied across input
terminals without damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm
(0.98 ft), approx. 150 g (5.3 oz)
Note: The unit-side plug of the 9320-01 is different from the 9320.
LOGIC PROBE 9321-01
Function
Detection of AC or DC relay drive signal for High/Low state recording.
Can also be used for power line interruption detection
Input
4 channels (isolated between unit and channels), HIGH/LOW range
switching, Input impedance: 100 kΩ or higher (HIGH range), 30 kΩ
or higher (LOW range)
Output (H)
detection
170 to 250 V AC, ±DC (70 to 250 V ) (HIGH range)
60 to 150 V AC, ±DC (20 to 150 V) (LOW range)
Output (L)
detection
0 to 30 V AC, ±DC (0 to 43 V) (HIGH range)
0 to 10 V AC, ±DC (0 to 15 V) (LOW range)
Response time
Rising edge 1 ms max., falling edge 3 ms max.
(with HIGH range at 200 V DC, LOW range at 100 V DC)
Maximum allowable
input voltage
250 Vrms (HIGH range), 150 Vrms (LOW range) (the maximum
voltage that can be applied across input terminals without damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft),
input section cable 1 m (3.28 ft), approx. 320 g (11.3 oz)
Note: The unit-side plug of the 9321-01 is different from the 9321.
DIFFERENTIAL PROBE 9322
Function
For high-voltage floating measurement, power line surge noise
detection, RMS rectified output measurement
DC mode
For waveform monitor output, frequency characteristics: DC to 10
MHz (±3 dB), amplitude accuracy: ±1 % of full scale (at max. 1000 V
DC), ±3 % of full scale (at max. 2000 V DC) (full scale: 2000 V DC)
AC mode
For detection of power line surge noise, frequency characteristics:
1 kHz to 10 MHz ±3 dB
RMS mode
DC/AC voltage RMS output detection, frequency characteristics:
DC, 40 Hz to 100 kHz, response speed: 200 ms or less (400 V AC),
accuracy: ±1 % of full scale (DC, 40 Hz to 1 kHz), ±4 % of full scale
(1 kHz to 100 kHz) (full scale: 1000 V AC)
Input
Input type: balanced differential input, input impedance/
capacitance: H-L 9 MΩ/10 pF, H/L-unit 4.5 MΩ/20 pF,
Max. rated voltage to earth: when using grabber clip 1500 V
AC/DC (CAT II ), 600 V AC/DC (CAT III), when using alligator
clip: 1000 V AC/DC (CAT II), 600 V AC/DC (CAT III)
Maximum allowable input
2000V DC, 1000V AC
Output
Voltage divider for 1/1000 of input, BNC connectors
(output switchable for 3 modes DC, AC, RMS)
Power source
Connect the AC ADAPTER 9418-15
(power cannot be supplied from the logic terminals of the MR8880
-20
)
Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm
(1.51 ft), approx. 350 g (12.3 oz)
Screen display
Display
5.7-inch VGA-TFT color LCD (640
×
480dot)
Waveform
display scale
Time axis: × 10 to × 2 (zoom view supported for high-speed
recording only), × 1, × 1/2 to × 1/2,000
Voltage axis: × 20 to × 2, × 1, × 1/2 to × 1/10
Comment input
Titles and comments input for individual channels
Logic waveform display
Select 2 recording widths; display positions can be set separately
Display items
•
Waveform display; simultaneous display of waveform and gage;
simultaneous display of waveform, gage, and settings; simultaneous
display of waveform and calculation results; simultaneous display
of waveform and cursor values (A/B cursor values)
The following display items are supported when using real-time functionality:
• Simultaneous display of waveform and comments, value display,
simultaneous display of waveform and values
Monitor function
Value (instantaneous value or RMS value) and measured waveform
(monitor screen display with refresh rate of 0.5 sec)
Display digits: 5
Instantaneous
value display
Time:
Display of time elapsed since start of measurement or trigger point
Date: Display of date and time at which data was captured
Number of data points: Display of number of data points captured since
start of measurement
Other display
functions
• Cursor measurement (two cursors [A/B], support for all channels)
• Upper and lower limits can be set (to align waveform amplitude with
upper and lower limits).
• The zero position of the analog waveform can be moved in 1% steps.
• The waveform display can be set to any of 24 colors.
• Zero adjustment can be performed for all channels and ranges at once.
■ Specifications of Options (sold separately)
■ Appearance and Dimensions
with PRINTER UNIT MR9000 attached
303 mm
(11.93 in)
199 mm
(7.83 in)
205 mm
(8.07 in)
199 mm
(7.83 in)
67 mm
(2.64 in)
Analog input (Isolated BNC terminal)
CF card slot
Logic probe
terminal
USB terminal
(for PC communication)
USB terminal
(for USB memory)
External
control
terminal
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of
warm-up time; accuracy guaranteed for 1 year)
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30
minutes of warm-up time; accuracy guaranteed for 1 year)

HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
http://www.hioki.co.jp / E-mail: os-com@hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: hioki@hiokiusa.com
All information correct as of Feb. 1, 2011. All specications are subject to change without notice. MR8880-20E2-12B Printed in Japan
DISTRIBUTED BY
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road
,
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
http://www.hioki.cn / E-mail: info@hioki.com.cn
Beijing Office : TEL +86-10-5867-4080/4081
Guangzhou Office : TEL +86-20-38392673/2676
HIOKI SINGAPORE PTE.LTD.
:
33 UBI AVENUE 3, #03-02 VERTEX, SINGAPORE 408868
TEL +65-6634-7677 FAX +65-6634-7477
E-mail: info@hioki.com.sg
HIOKI INDIA PRIVATE LIMITED :
Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India
TEL +91-731-4223901, 4223902 FAX +91-731-4223903
http://www.hioki.in / E-mail: info@hioki.in
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
High-Voltage measurement
Options
RECORDING PAPER 9234
112 mm (4.41 in) × 18 m (59.06 ft),
10 rolls set
DIFFERENTIAL PROBE 9322
For up to 2 kV DC or 1 kV AC.
Use with the AC Adapter 9418-15,
for power supply.
AC ADAPTER 9418-15
For powering Differential probe
9322, 100 to 240 V AC.
Printer options
CONNECTION CORD
9197
For high voltage (up to 600 V)
1.8 m (5.91 ft) length
CONNECTION CORD
9198
For low voltage (up to 300 V)
1.7 m (5.58 ft) length
LOGIC PROBE 9321
-01
4 isolated channels, ON/OFF detection
of AC/DC voltage
(miniature terminal type)
LOGIC PROBE 9320
-01
4-channel type, for voltage/contact signal
ON/OFF detection (response time 0.5 ms,
miniature terminal type)
Logic signal measurement
Voltage measurement
Input cable for measurement use is not provided. Please purchase the optional cable.
CONNECTION CORD 9790
(Thin Type)
CAT II 300 V, ultra-flexible 2.8 mm (0.11 in)
diameter test lead cable, 1.5 m (4.92 ft) length
Note: Attachment clips sold separately.
Other options
CONNECTION CORD 9217
Cord has insulated BNC connectors at both
ends, and connects to insulated BNC connectors
on input terminal. 1.7 m (5.58 ft) length.
Carrying case
CARRYING CASE C1003
Hard case type, for storing options
PRINTER UNIT MR9000
Printing width 100 mm (3.94 in),
used together with the MR8880
-20
main body, includes 1 roll of recording paper
Removable storage (CF card)
Supplied with PC Card adapter
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance are not
guaranteed for PC cards made by other
manufacturers. You may be unable to read
from or save data to such cards.
PC CARD 2G 9830
(2 GB capacity)
PC CARD 1G 9729
(1 GB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
MEMORY HiCORDER
MR8880-20
ALLIGATOR CLIP 9790
-01
Red/black set attaches to the
ends of test leads (9790)
GRABBER CLIP 9790
-02
Red/black set attaches to the
ends of test leads (9790)
CONTACT PIN 9790
-03
Red/black set attaches to the
ends of test leads (9790)
Current measurement *50/60 Hz line use
9018
-50
Enables observation of AC
current waveforms.
Input: 40 Hz to 3 kHz,
selectable 10 to 500 A ranges,
Output: 0.2 V AC/ range
CLAMP ON PROBE (for load current measurement)
CLAMP ON LEAK SENSOR
(for leak current measurement)
Tip Expanders
Main device CONNECTION CORD
(up to 600 V)
l Example setup for 4-channel voltage measurement (up to 600 V)
MR8880-20 + 9197
×
4 +MR9000 + Z1000 + 9727 + C1003
PRINTER
UNIT
BAT TERY
PACK
PC CARD
(256MB)
CARRYING
CASE
Supplied
accessories:
AC adapter Z1002 (1), Alkaline battery box (1)
Strap (1), USB cable (1), Wave viewer software (1)
Instrument power
BATTERY PACK Z1000
7.2V, 4500mAh
Current measurement *High precision type
UNIVERSAL CLAMP ON CT
9278
Observe waveforms from DC to distorted AC.
DC to 100kHz response, input 200A / output 2V AC
CLAMP ON SENSOR
9272
-10
Enables observation of AC current waveforms.
Input: 1 to 100kHz, selectable 20 and 200A rms
ranges, 2V AC output
(
Not CE marked
)
UNIVERSAL CLAMP ON CT
9277
Observe waveforms from DC to distorted AC.
DC to 100kHz response, input 20A / output 2V AC
UNIVERSAL CLAMP ON CT
9279
Observe waveforms from DC to distorted AC.
DC to 20kHz response, input 500A / output 2V AC
CLAMP ON PROBE
3273-50
DC to 50MHz wideband response, mA-class
current up to 30A rms
Current measurement *For Oscilloscope, wide-band frequency type
CLAMP ON PROBE
3276
DC to 100MHz wideband response,
mA-class current up to 30A rms
CLAMP ON PROBE
3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
CLAMP ON PROBE
3275
DC to 2MHz wideband response,
mA-class current up to 500A rms
Power supply for sensors and CTs sold separately Power supply for probes sold separately
High-Voltage measurement
Tip Expanders
9010
-50
Enables observation of AC
current waveforms.
Input: 40 Hz to 1 kHz,
selectable 10 to 500 A ranges,
Output: 0.2 V AC/ range
9132
-50
Enables observation of AC
current waveforms.
Input: 40 Hz to 1 kHz,
selectable 20 to 1000 A ranges,
Output: 0.2 V AC/ range
9657
-10
For leak curent measurement
Input: 40 Hz to 5 kHz, 10 A range
Output: 0.1 V AC/A
9675
For leak curent measurement
Input: 40 Hz to 5 kHz, 10 A range
Output: 0.1 V AC/A
GRABBER CLIP
9243
Red/black set attaches
to the 9197
196mm (7.72in) length
Other manuals for MR8880-20
3
Table of contents
Other Hioki Measuring Instrument manuals

Hioki
Hioki Super megohm SM7110 User manual

Hioki
Hioki 3196 User manual

Hioki
Hioki DSM-8542 User manual

Hioki
Hioki Hioki User manual

Hioki
Hioki LR8450 User manual

Hioki
Hioki 8715-01 User manual

Hioki
Hioki 3293-50 User manual

Hioki
Hioki TM6101 User manual

Hioki
Hioki CM4002 User manual

Hioki
Hioki HiTester 3443-01 User manual
Popular Measuring Instrument manuals by other brands

Honeywell
Honeywell E-Mon Class 1000 quick start guide

J.ASSY
J.ASSY VISUM Monitor Operator's manual

Gallagher
Gallagher C500615 Installation notes

Keysight Technologies
Keysight Technologies N5222B Installation notes

Keysight
Keysight 85024A User's and service guide

Tektronix
Tektronix DM 502 instruction manual