Copyright HK Instruments 2017 www.hkinstruments. Installaon version 5.0 2017
INSTALLATION
INSTRUCTIONS
HUMIDITY TRANSMITTERS
RHT-MOD Duct Series
• READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS
DEVICE.
• Failuretoobservesafetyinformaonandcomplywith
instruconscanresultinPERSONALINJURY,DEATHAND/OR
PROPERTY DAMAGE.
• Toavoidelectricalshockordamagetoequipment,disconnect
powerbeforeinstallingorservicinganduseonlywiringwith
insulaonratedforfulldeviceoperangvoltage.
• Toavoidpotenalreand/orexplosiondonotuseinpotenally
ammableorexplosiveatmospheres.
• Retaintheseinstruconsforfuturereference.
• Thisproduct,wheninstalled,willbepartofanengineered
systemwhosespecicaonsandperformancecharacteriscs
arenotdesignedorcontrolledbyHKInstruments.Review
applicaonsandnaonalandlocalcodestoassurethatthe
installaonwillbefunconalandsafe.Useonlyexperiencedand
knowledgeabletechnicianstoinstallthisdevice.
SPECIFICATIONS
Thank you for choosing an HK Instruments RHT-MOD Duct se-
riesrelavehumiditytransmierwithModbusinterface.TheRHT
-MODDuctseriesisintendedforuseincommercialenvironments
inHVAC/Rapplicaons.
RHT-MODDuctisarelavehumiditytransmierwithtemperature
outputinstalledinairvenlaonduct.Illuminateddisplayensures
easy readability also from a distance. The RHT-MOD Duct has a
screwlesslidandaneasilyadjustablemounngangethatmakethe
installaonofthedeviceeasy.
RHT-MOD Duct series devices are commonly used to monitor and
control:
•Relavehumidityandtemperaturelevelsofincomingandreturnair
invenlaonsystem
SPECIFICATIONS
Performance
Measurement ranges:
Temperature:0...50°C
Relavehumidity:0–100%
Accuracy:
Temperature:<0.5ºC
Relavehumidity:±2...3%at0...50°Cand10–90%rH
Totalerrorbandincludesaccuracy,hysteresisand
temperatureeectover5...50°Cand10–90%rH.
Technical Specicaons
Media compability:
Dryairornon-aggressivegases
Measuring units:
°Cand%rH
Measuring element:
Temperature:NTC10K
Relavehumidity:Thermosetpolymercapacive
sensingelement
Environment:
Operangtemperature:0...50°C
Storagetemperature:-20...70°C
Humidity:0to95%rH,noncondensing
Physical
Dimensions:
Case:119x100x44.7mm
Probe:L=188mm,d=12mm
Mounng:
Withange,adjustable0...188mm
Weight:
150g
Materials:
Case:ABS
Cover:PC
Probe:ABS
Mounngange:LLPDP
Protecon standard:
IP54
Electrical connecons:
 4springloadedterminals
Powersupply:
 (24VandGND)
 0.2–1.5mm2(12–24AWG)
ModbusRTU:
 AandBline
 0.2–1.5mm2(12–24AWG)
Electrical
Supplyvoltage:24VACorVDC±10%
Currentconsumpon:max90mA(at24V)+10mAfor
eachvoltageoutput
Communicaon
Protocol:MODBUSoverSerialLine
TransmissionMode:RTU
Interface:RS485
Byteformat(11bits)inRTUmode:
 CodingSystem:8-bitbinary
 BitsperByte:
  1startbit
  8databits,leastsignicantbitsent
  rst
  1bitforparity
  1stopbit
Baudrate:selectableinconguraon
Modbusaddress:1−247addressesselectablein
conguraonmenu
Conformance
MeetsrequirementsforCEmarking:
EMCDirecve:2014/30/EU
RoHSDirecve:2011/65/EU
WEEEDirecve:2012/19/EU
INTRODUCTION WARNING
APPLICATIONS
COMPANY WITH
MANAGEMENT SYSTEM
CERTIFIED BY DNV GL
= ISO 9001 = ISO 14001 =
RoHS 2
2011/65/EU
Copyright HK Instruments 2017 www.hkinstruments. Installaon version 5.0 2017
Tighten the
screw
SCHEMATICS
DIMENSIONAL DRAWINGS
INSTALLATION
STEP 1: MOUNTING THE DEVICE
1)Mountthedeviceinthedesiredlocaon(seestep1).
2)Routethecablesandconnectthewires(seestep2).
3)Thedeviceisnowreadyforconguraon.
WARNING!Applypoweronlyaerthedeviceisproperlywired.
1)Selectthemounnglocaon(onaduct).
2)Usethemounngangeofthedeviceasatemplateandmarkthe
screwholes.
3)Mounttheangeontheductwithscrews(notincluded).(Figure1a)
4)Adjusttheprobetothedesireddepth.Ensurethattheendofthe
probereachesthemiddleoftheduct.(Figure1b)
5)Tightenthescrewontheangetoholdtheprobeinposion.
Figure 1a - Mounng a ange
Figure 1b - Mounng the probe in a ange
Air flow direcon Air flow direcon
Air flow direcon Air flow direcon Air flow direcon
Strain relief facing down
Figure 1c - Mounng orientaon
Display connecon
Terminal block
A
B
24 V
GND
Joysck 1
Joysck 2
Joysck 3
Select
Up
Down
Menu buons
Copyright HK Instruments 2017 www.hkinstruments. Installaon version 5.0 2017
STEP 3: CONFIGURATION
STEP 4: MODBUS REGISTERS
ForCEcomplianceaproperlygroundedshieldingcableis
required.
1)Unscrewthestrainreliefandroutethecable(s).
2)Connectthewiresasshowningure2a.
3)Tightenthestrainrelief.
A
24 V
GND
+ Power Supply
24VDC / 24VAC
Modbus A
Modbus B
B
WARRANTY POLICY
Thesellerisobligatedtoprovideawarrantyofveyearsforthedeliv-
eredgoodsregardingmaterialandmanufacturing.Thewarrantyperiod
isconsideredtostartonthedeliverydateoftheproduct.Ifadefectin
rawmaterialsoraproduconawisfound,thesellerisobligated,when
theproductissenttothesellerwithoutdelayorbeforeexpiraonof
thewarranty,toamendthemistakeathis/herdiscreoneitherbyre-
pairingthedefecveproductorbydeliveringfreeofchargetothebuy-
eranewawlessproductandsendingittothebuyer.Deliverycosts
fortherepairunderwarrantywillbepaidbythebuyerandthereturn
costsbytheseller.Thewarrantydoesnotcomprisedamagescausedby
accident, lightning, ood or other natural phenomenon, normal wear
andtear,improperorcarelesshandling,abnormaluse,overloading,im-
properstorage,incorrectcareorreconstrucon,orchangesandinstal-
laonworknotdonebythesellerorhis/herauthorizedrepresentave.
Theseleconofmaterialsfordevicespronetocorrosionisthebuyer’s
responsibility,unlessotherwiseislegallyagreedupon.Shouldtheman-
ufactureralterthestructureofthedevice,thesellerisnotobligatedto
makecomparablechangestodevicesalreadypurchased.Appealingfor
warrantyrequiresthatthebuyerhascorrectlyfullledhis/herdues
arisenfromthedeliveryandstatedinthecontract.Thesellerwillgive
anewwarrantyforgoodsthathavebeenreplacedorrepairedwithin
thewarranty,howeveronlytotheexpiraonoftheoriginalproduct’s
warrantyme.Thewarrantyincludestherepairofadefecvepartor
device, orifneeded,a new partordevice,butnotinstallaonorex-
change costs. Underno circumstanceisthe seller liable fordamages
compensaonforindirectdamage.
1)AcvatethedeviceMenubypushingthetheselectbuonfor2
seconds.
2)SelecttheaddressforModbus:1...247.
ADDRESS
99
SELECT
UP
DOWN
3)Selectthebaudrate:9600/19200/38400.
BAUD RATE
9600
SELECT
UP
DOWN
3)Selecttheparitybit:None/Even/Odd.
PARITY BIT
NONE
SELECT
UP
DOWN
4)Pushtheselectbuontoexitmenu.
SELECT
EXIT MENU SELECT
Funcon04-Readinputregister
Register Parameter descripon Data Type Value Range
3x0001 Programversion 16bit 0...1000 0.0...99.00
3x0003 rHreading 16bit 0...1000 0.0...100.0%
3x0004 Temperaturereading 16bit 0...500 0.0...50.0°C
STEP 2: WIRING DIAGRAMS
RECYCLING/DISPOSAL
The parts le over from installaon should be
recycled according to your local instrucons.
Decommissioned devices should be taken to a
recyclingsitethatspecializesinelectronicwaste.
Figure 2 - Wiring diagram

Other HK Instruments Transmitter manuals

HK Instruments RHT-MOD Duct Series User manual

HK Instruments

HK Instruments RHT-MOD Duct Series User manual

HK Instruments RHT Series User manual

HK Instruments

HK Instruments RHT Series User manual

HK Instruments AVT Series User manual

HK Instruments

HK Instruments AVT Series User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

HK Instruments DPT-Priima Series User manual

HK Instruments

HK Instruments DPT-Priima Series User manual

HK Instruments RHT Series User manual

HK Instruments

HK Instruments RHT Series User manual

HK Instruments CDT2000 Series User manual

HK Instruments

HK Instruments CDT2000 Series User manual

HK Instruments DPT-Priima Series User manual

HK Instruments

HK Instruments DPT-Priima Series User manual

HK Instruments DPT-Priima Series User manual

HK Instruments

HK Instruments DPT-Priima Series User manual

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments DPT-Flow-1000 Quick start guide

HK Instruments

HK Instruments DPT-Flow-1000 Quick start guide

HK Instruments CDT-MOD-2000 Series User manual

HK Instruments

HK Instruments CDT-MOD-2000 Series User manual

HK Instruments DPT-Dual-MOD Series User manual

HK Instruments

HK Instruments DPT-Dual-MOD Series User manual

HK Instruments CDT-MOD-2000 Series User manual

HK Instruments

HK Instruments CDT-MOD-2000 Series User manual

HK Instruments Siro-MOD Series User manual

HK Instruments

HK Instruments Siro-MOD Series User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

HK Instruments RHT Series User manual

HK Instruments

HK Instruments RHT Series User manual

HK Instruments RHT-MOD Series User manual

HK Instruments

HK Instruments RHT-MOD Series User manual

HK Instruments KLU 100 User manual

HK Instruments

HK Instruments KLU 100 User manual

HK Instruments RHT-MOD Duct Series User manual

HK Instruments

HK Instruments RHT-MOD Duct Series User manual

HK Instruments DPT Series User manual

HK Instruments

HK Instruments DPT Series User manual

HK Instruments AVT Series User manual

HK Instruments

HK Instruments AVT Series User manual

HK Instruments RHT DUCT Series User manual

HK Instruments

HK Instruments RHT DUCT Series User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

Popular Transmitter manuals by other brands

Jobsite IR-E2 datasheet

Jobsite

Jobsite IR-E2 datasheet

Optex SC-U1 Operation manual

Optex

Optex SC-U1 Operation manual

Motorola CB200-M user guide

Motorola

Motorola CB200-M user guide

Gogen CTR 348 BTC user manual

Gogen

Gogen CTR 348 BTC user manual

Magnetrol Kotron II Series 801 instruction manual

Magnetrol

Magnetrol Kotron II Series 801 instruction manual

Emerson Bristol 2808 Series instruction manual

Emerson

Emerson Bristol 2808 Series instruction manual

ARTEX ME406 Handbook

ARTEX

ARTEX ME406 Handbook

Telex PST-170 operating instructions

Telex

Telex PST-170 operating instructions

Kramer TP-780T user manual

Kramer

Kramer TP-780T user manual

Sony WRT-8B operating instructions

Sony

Sony WRT-8B operating instructions

Stingray 318LIPW1V quick guide

Stingray

Stingray 318LIPW1V quick guide

Philips HC 8372 Specification sheet

Philips

Philips HC 8372 Specification sheet

Sony TMR-IF130 Service manual

Sony

Sony TMR-IF130 Service manual

Alpha Moisture Systems ADHT-E Series quick start guide

Alpha Moisture Systems

Alpha Moisture Systems ADHT-E Series quick start guide

Long range T4300A quick start guide

Long range

Long range T4300A quick start guide

Comet System T2214 instruction manual

Comet System

Comet System T2214 instruction manual

Allied Radio knight-kit tT-50 manual

Allied Radio

Allied Radio knight-kit tT-50 manual

Azbil PREX3000 user manual

Azbil

Azbil PREX3000 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.