manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HK Instruments
  6. •
  7. Transmitter
  8. •
  9. HK Instruments RHT-MOD Duct Series User manual

HK Instruments RHT-MOD Duct Series User manual

Copyright HK Instruments 2017 www.hkinstruments. Installaon version 5.0 2017
INSTALLATION
INSTRUCTIONS
HUMIDITY TRANSMITTERS
RHT-MOD Duct Series
• READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS
DEVICE.
• Failuretoobservesafetyinformaonandcomplywith
instruconscanresultinPERSONALINJURY,DEATHAND/OR
PROPERTY DAMAGE.
• Toavoidelectricalshockordamagetoequipment,disconnect
powerbeforeinstallingorservicinganduseonlywiringwith
insulaonratedforfulldeviceoperangvoltage.
• Toavoidpotenalreand/orexplosiondonotuseinpotenally
ammableorexplosiveatmospheres.
• Retaintheseinstruconsforfuturereference.
• Thisproduct,wheninstalled,willbepartofanengineered
systemwhosespecicaonsandperformancecharacteriscs
arenotdesignedorcontrolledbyHKInstruments.Review
applicaonsandnaonalandlocalcodestoassurethatthe
installaonwillbefunconalandsafe.Useonlyexperiencedand
knowledgeabletechnicianstoinstallthisdevice.
SPECIFICATIONS
Thank you for choosing an HK Instruments RHT-MOD Duct se-
riesrelavehumiditytransmierwithModbusinterface.TheRHT
-MODDuctseriesisintendedforuseincommercialenvironments
inHVAC/Rapplicaons.
RHT-MODDuctisarelavehumiditytransmierwithtemperature
outputinstalledinairvenlaonduct.Illuminateddisplayensures
easy readability also from a distance. The RHT-MOD Duct has a
screwlesslidandaneasilyadjustablemounngangethatmakethe
installaonofthedeviceeasy.
RHT-MOD Duct series devices are commonly used to monitor and
control:
•Relavehumidityandtemperaturelevelsofincomingandreturnair
invenlaonsystem
SPECIFICATIONS
Performance
Measurement ranges:
Temperature:0...50°C
Relavehumidity:0–100%
Accuracy:
Temperature:<0.5ºC
Relavehumidity:±2...3%at0...50°Cand10–90%rH
Totalerrorbandincludesaccuracy,hysteresisand
temperatureeectover5...50°Cand10–90%rH.
Technical Specicaons
Media compability:
Dryairornon-aggressivegases
Measuring units:
°Cand%rH
Measuring element:
Temperature:NTC10K
Relavehumidity:Thermosetpolymercapacive
sensingelement
Environment:
Operangtemperature:0...50°C
Storagetemperature:-20...70°C
Humidity:0to95%rH,noncondensing
Physical
Dimensions:
Case:119x100x44.7mm
Probe:L=188mm,d=12mm
Mounng:
Withange,adjustable0...188mm
Weight:
150g
Materials:
Case:ABS
Cover:PC
Probe:ABS
Mounngange:LLPDP
Protecon standard:
IP54
Electrical connecons:
 4springloadedterminals
Powersupply:
 (24VandGND)
 0.2–1.5mm2(12–24AWG)
ModbusRTU:
 AandBline
 0.2–1.5mm2(12–24AWG)
Electrical
Supplyvoltage:24VACorVDC±10%
Currentconsumpon:max90mA(at24V)+10mAfor
eachvoltageoutput
Communicaon
Protocol:MODBUSoverSerialLine
TransmissionMode:RTU
Interface:RS485
Byteformat(11bits)inRTUmode:
 CodingSystem:8-bitbinary
 BitsperByte:
  1startbit
  8databits,leastsignicantbitsent
  rst
  1bitforparity
  1stopbit
Baudrate:selectableinconguraon
Modbusaddress:1−247addressesselectablein
conguraonmenu
Conformance
MeetsrequirementsforCEmarking:
EMCDirecve:2014/30/EU
RoHSDirecve:2011/65/EU
WEEEDirecve:2012/19/EU
INTRODUCTION WARNING
APPLICATIONS
COMPANY WITH
MANAGEMENT SYSTEM
CERTIFIED BY DNV GL
= ISO 9001 = ISO 14001 =
RoHS 2
2011/65/EU
Copyright HK Instruments 2017 www.hkinstruments. Installaon version 5.0 2017
Tighten the
screw
SCHEMATICS
DIMENSIONAL DRAWINGS
INSTALLATION
STEP 1: MOUNTING THE DEVICE
1)Mountthedeviceinthedesiredlocaon(seestep1).
2)Routethecablesandconnectthewires(seestep2).
3)Thedeviceisnowreadyforconguraon.
WARNING!Applypoweronlyaerthedeviceisproperlywired.
1)Selectthemounnglocaon(onaduct).
2)Usethemounngangeofthedeviceasatemplateandmarkthe
screwholes.
3)Mounttheangeontheductwithscrews(notincluded).(Figure1a)
4)Adjusttheprobetothedesireddepth.Ensurethattheendofthe
probereachesthemiddleoftheduct.(Figure1b)
5)Tightenthescrewontheangetoholdtheprobeinposion.
Figure 1a - Mounng a ange
Figure 1b - Mounng the probe in a ange
Air flow direcon Air flow direcon
Air flow direcon Air flow direcon Air flow direcon
Strain relief facing down
Figure 1c - Mounng orientaon
Display connecon
Terminal block
A
B
24 V
GND
Joysck 1
Joysck 2
Joysck 3
Select
Up
Down
Menu buons
Copyright HK Instruments 2017 www.hkinstruments. Installaon version 5.0 2017
STEP 3: CONFIGURATION
STEP 4: MODBUS REGISTERS
ForCEcomplianceaproperlygroundedshieldingcableis
required.
1)Unscrewthestrainreliefandroutethecable(s).
2)Connectthewiresasshowningure2a.
3)Tightenthestrainrelief.
A
24 V
GND
+ Power Supply
24VDC / 24VAC
Modbus A
Modbus B
B
WARRANTY POLICY
Thesellerisobligatedtoprovideawarrantyofveyearsforthedeliv-
eredgoodsregardingmaterialandmanufacturing.Thewarrantyperiod
isconsideredtostartonthedeliverydateoftheproduct.Ifadefectin
rawmaterialsoraproduconawisfound,thesellerisobligated,when
theproductissenttothesellerwithoutdelayorbeforeexpiraonof
thewarranty,toamendthemistakeathis/herdiscreoneitherbyre-
pairingthedefecveproductorbydeliveringfreeofchargetothebuy-
eranewawlessproductandsendingittothebuyer.Deliverycosts
fortherepairunderwarrantywillbepaidbythebuyerandthereturn
costsbytheseller.Thewarrantydoesnotcomprisedamagescausedby
accident, lightning, ood or other natural phenomenon, normal wear
andtear,improperorcarelesshandling,abnormaluse,overloading,im-
properstorage,incorrectcareorreconstrucon,orchangesandinstal-
laonworknotdonebythesellerorhis/herauthorizedrepresentave.
Theseleconofmaterialsfordevicespronetocorrosionisthebuyer’s
responsibility,unlessotherwiseislegallyagreedupon.Shouldtheman-
ufactureralterthestructureofthedevice,thesellerisnotobligatedto
makecomparablechangestodevicesalreadypurchased.Appealingfor
warrantyrequiresthatthebuyerhascorrectlyfullledhis/herdues
arisenfromthedeliveryandstatedinthecontract.Thesellerwillgive
anewwarrantyforgoodsthathavebeenreplacedorrepairedwithin
thewarranty,howeveronlytotheexpiraonoftheoriginalproduct’s
warrantyme.Thewarrantyincludestherepairofadefecvepartor
device, orifneeded,a new partordevice,butnotinstallaonorex-
change costs. Underno circumstanceisthe seller liable fordamages
compensaonforindirectdamage.
1)AcvatethedeviceMenubypushingthetheselectbuonfor2
seconds.
2)SelecttheaddressforModbus:1...247.
ADDRESS
99
SELECT
UP
DOWN
3)Selectthebaudrate:9600/19200/38400.
BAUD RATE
9600
SELECT
UP
DOWN
3)Selecttheparitybit:None/Even/Odd.
PARITY BIT
NONE
SELECT
UP
DOWN
4)Pushtheselectbuontoexitmenu.
SELECT
EXIT MENU SELECT
Funcon04-Readinputregister
Register Parameter descripon Data Type Value Range
3x0001 Programversion 16bit 0...1000 0.0...99.00
3x0003 rHreading 16bit 0...1000 0.0...100.0%
3x0004 Temperaturereading 16bit 0...500 0.0...50.0°C
STEP 2: WIRING DIAGRAMS
RECYCLING/DISPOSAL
The parts le over from installaon should be
recycled according to your local instrucons.
Decommissioned devices should be taken to a
recyclingsitethatspecializesinelectronicwaste.
Figure 2 - Wiring diagram

Other HK Instruments Transmitter manuals

HK Instruments DPT-2W- 100-R2 User manual

HK Instruments

HK Instruments DPT-2W- 100-R2 User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

HK Instruments RHT-MOD Duct Series User manual

HK Instruments

HK Instruments RHT-MOD Duct Series User manual

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments CDT-MOD-2000 Series User manual

HK Instruments

HK Instruments CDT-MOD-2000 Series User manual

HK Instruments DPT-Flow Series User manual

HK Instruments

HK Instruments DPT-Flow Series User manual

HK Instruments RHT-MOD Duct Series User manual

HK Instruments

HK Instruments RHT-MOD Duct Series User manual

HK Instruments RHT DUCT Series User manual

HK Instruments

HK Instruments RHT DUCT Series User manual

HK Instruments CDT Series User manual

HK Instruments

HK Instruments CDT Series User manual

HK Instruments DPT-Ctrl-MOD Series User manual

HK Instruments

HK Instruments DPT-Ctrl-MOD Series User manual

HK Instruments RHT Series User manual

HK Instruments

HK Instruments RHT Series User manual

HK Instruments DPT2500-R8 Series Instruction manual

HK Instruments

HK Instruments DPT2500-R8 Series Instruction manual

HK Instruments AVT Series User manual

HK Instruments

HK Instruments AVT Series User manual

HK Instruments AVT Series User manual

HK Instruments

HK Instruments AVT Series User manual

HK Instruments DPT-Priima Series User manual

HK Instruments

HK Instruments DPT-Priima Series User manual

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments DPT-Priima Series User manual

HK Instruments

HK Instruments DPT-Priima Series User manual

HK Instruments DPT-CR-MOD Series User manual

HK Instruments

HK Instruments DPT-CR-MOD Series User manual

HK Instruments CDT2000 Series User manual

HK Instruments

HK Instruments CDT2000 Series User manual

HK Instruments RHT-MOD Series User manual

HK Instruments

HK Instruments RHT-MOD Series User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

HK Instruments DPT Series User manual

HK Instruments

HK Instruments DPT Series User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

HK Instruments CMT Series User manual

HK Instruments

HK Instruments CMT Series User manual

Popular Transmitter manuals by other brands

DGFLOW TEEVALVE 10 1 1/2 Operator and  maintenance manual

DGFLOW

DGFLOW TEEVALVE 10 1 1/2 Operator and maintenance manual

Entrematic BIXLR12 Installation and use manual

Entrematic

Entrematic BIXLR12 Installation and use manual

Metrix ST5491E installation manual

Metrix

Metrix ST5491E installation manual

Blu Stream Multicast IP250UHD-TX user manual

Blu Stream

Blu Stream Multicast IP250UHD-TX user manual

Tecnocontrol TS220EC-S user manual

Tecnocontrol

Tecnocontrol TS220EC-S user manual

Watchguard CMR24WAT user guide

Watchguard

Watchguard CMR24WAT user guide

IMG STAGE LINE TXS-606HSE/2 instruction manual

IMG STAGE LINE

IMG STAGE LINE TXS-606HSE/2 instruction manual

J-TECH MultiCast Quick setup guide

J-TECH

J-TECH MultiCast Quick setup guide

Veris Industries G Series installation guide

Veris Industries

Veris Industries G Series installation guide

Status Pro T250 instruction manual

Status Pro

Status Pro T250 instruction manual

Linear MULTI-CODE 1051 manual

Linear

Linear MULTI-CODE 1051 manual

MTS Sensors Level Plus Interface manual

MTS Sensors

MTS Sensors Level Plus Interface manual

Emcee TTU500FA user manual

Emcee

Emcee TTU500FA user manual

Vaisala HUMICAP HMT330 SERIES user guide

Vaisala

Vaisala HUMICAP HMT330 SERIES user guide

Kramer VP-300THD user manual

Kramer

Kramer VP-300THD user manual

ADEMCO 5817CB quick start guide

ADEMCO

ADEMCO 5817CB quick start guide

Simu 5C instructions

Simu

Simu 5C instructions

PST PST-UM-2010-EN-02 user manual

PST

PST PST-UM-2010-EN-02 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.