Copyright HK Instruments 2021 www.hkinstruments. Installaon version 7.0 2021
INSTALLATION
INSTRUCTIONS
CARBON DIOXIDE TRANSMITTERS
CDT-MOD-2000 Series
• READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS
DEVICE.
• Failuretoobservesafetyinformaonandcomplywith
instruconscanresultinPERSONALINJURY,DEATHAND/OR
PROPERTY DAMAGE.
• Toavoidelectricalshockordamagetoequipment,disconnect
powerbeforeinstallingorservicinganduseonlywiringwith
insulaonratedforfulldeviceoperangvoltage.
• Toavoidpotenalreand/orexplosiondonotuseinpotenally
ammableorexplosiveatmospheres.
• Retaintheseinstruconsforfuturereference.
• Thisproduct,wheninstalled,willbepartofanengineered
systemwhosespecicaonsandperformancecharacteriscs
arenotdesignedorcontrolledbyHKInstruments.Review
applicaonsandnaonalandlocalcodestoassurethatthe
installaonwillbefunconalandsafe.Useonlyexperiencedand
knowledgeabletechnicianstoinstallthisdevice.
ThankyouforchoosinganHKInstrumentsCDT-MOD-2000series
carbondioxidetransmier.TheCDT-MOD-2000seriesisintended
for use in commercial environments in HVAC/R applicaons. The
CDT-MOD-2000seriesmeasurescarbondioxide(CO2),ulizingthe
industry standard NDIR measurement principle, and temperature
(T).Oponalrelavehumidity(rH)measurementisalsoavailablein
thesamedevice.TheCDT-MOD-2000seriesdevicesareavailable
withlargetouchscreendisplaymakingtheconguraonofthede-
vicequickandeasy.ConguraonisalsopossibleviaModbusnet-
work.
TheCDT-MOD-2000seriestransmierscalibratethemselvesauto-
macallyusingABCTMlogic.TheABCTMlogicrequiresthatthespace
inwhichthetransmierisusedneedstotobeunoccupiedforfour
hours per day so that the indoor CO2 concentraon drops to the
outside level.CDT-MOD-2000-DC isa dualchannel modelwith a
measuringchannelandareferencechannelthatmakesaconnuous
comparisonandthenecessaryadjustmentaccordingly.CDT-MOD-
2000-DC isalsosuitableforbuildings that areconnuouslyoccu-
pied.
•humidityinvariousindustrialapplicaons
•temperaturesinHVAC/Renvironment
•CDT-MOD-2000-DCseriesdevicescanalsobeusedinapplicaons
wherethereisaconstantsourceofcarbondioxidepresent(for
examplehospitalsandgreenhouses)
SPECIFICATIONS
Performance
Measurement ranges:
CO2:400–2000ppm
Temperature:0...50°C
Relavehumidity:0–100%
Accuracy:
CO2:±40ppm+2%ofreading,DCmodel:75ppmor10%
ofreading(whicheverisgreater)
Temperature:<0.5ºC
Relavehumidity:±2...3%at0...50°Cand10–90%rH
Totalerrorbandincludesaccuracy,hysteresisand
temperatureeectover5...50°Cand10–90%rH.
Technical Specicaons
Media compability:
Dryairornon-aggressivegases
Measuring units:
ppm,°Cand%rH
Measuring element:
CO2:Non-dispersiveinfrared(NDIR)
Temperature: Pt1000(modelswithoutrH-measurement)
 Integrated(modelswithrH-measurement)
Relavehumidity:Thermosetpolymercapacivesensing
element
Calibraon:
Automacself-calibraonABCLogicTMorconnuous
comparison(DC)
Environment:
Operangtemperature:0...50°C
Storagetemperature:-20...70°C
Humidity:0to95%rH,noncondensing
Physical
Dimensions:
Case:99x90x32mm
Weight:
150g
Mounng:
3screwholessloed,3.8mm
Materials:
Case: ABS
Protecon standard:
IP20
Display (Oponal)
Touchscreen
Size:77.4x52.4mm
Electrical connecons:
Powersupply:
 5-screwterminalblock
 (24V,GND)
 0.2–1.5mm2(12–24AWG)
Relay out:
 3-screwterminalblock
 (NC,COM,NO)
 0.2–1.5mm2(12–24AWG)
Electrical
Input: 24VACorVDC,±10%
 Currentconsumpon:max90mA(at24V)+
 10mAforeachvoltageoutputor20mAfor
 eachcurrentoutput
Relay out:
 SPDTRelay,250VAC/30VDC/6A
 Adjustableswitchingpointandhysteresis
Oneanalogoutputforselectedmedia:
0/2*–10VDC,LoadRminimum1kΩ
*(2–10VDCdisplaymodelsonly) or
4–20mA,maximumload500Ω
Communicaon
Protocol:MODBUSoverSerialLine
TransmissionMode:RTU
Interface:RS485
Byteformat(11bits)inRTUmode:
 CodingSystem:8-bitbinary
 BitsperByte:
  1startbit
  8databits,leastsignicantbitsent
  rst
  1bitforparity
  1stopbit
Baudrate:selectableinconguraon
Modbusaddress:1−247addressesselectablein
conguraonmenu
Conformance
MeetsrequirementsforCEmarking:
EMCDirecve2014/35/EU
RoHSDirecve2011/65/EU
LVDDirecve2014/35/EU
WEEEDirecve2012/19/EU
INTRODUCTION
APPLICATIONS
WARNING
CDT-MOD-2000seriesdevicesarecommonlyusedtomonitor:
• CO2andhumiditylevelsinoces,publicspaces,meengrooms
andclassrooms
• CO2levelsofreturnairinvenlaonsystems
•incomingairandreturnairhumiditylevelsinvenlaonsystem
COMPANY WITH
MANAGEMENT SYSTEM
CERTIFIED BY DNV GL
= ISO 9001 = ISO 14001 =
RoHS 2
2011/65/EU
Copyright HK Instruments 2021 www.hkinstruments. Installaon version 7.0 2021
SCHEMATICS
DIMENSIONAL DRAWINGS
INSTALLATION
STEP 1: MOUNTING THE DEVICE
1)Mountthedeviceinthedesiredlocaon(seestep1).
2)Routethecablesandconnectthewires(seestep2).
3)Thedeviceisnowreadyforconguraon.
WARNING!Applypoweronlyaerthedeviceisproperlywired.
Figure 1a - Surface mounng
1)Selectamounnglocaononthewallat1.2–1.8m(4–6)above
theoorandatleast50cm(20in)fromtheadjacentwall.Do
notblockdeviceairventsfromanydireconandleaveatleast
20cm(8in)gaptootherdevices.Locatetheunitinanareawith
goodvenlaonandanaveragetemperature,whereitwillbe
responsivetochangestotheroomcondions.TheCDT-MOD
shouldbemountedonaatsurface.
DonotlocatetheCDT-MODwhereitcanbeaectedby:
•Directsunlight
•Drasordeadareasbehinddoors
•Radiantheatfromappliances
•Concealedpipesorchimneys
•Outsidewallsorunheated/uncooledareas
2)Usethedeviceasatemplateandmarkthescrewholes.
3)Mountthewallplatewithscrews.
•Incorrectinstallaonmaycauseashiintemperatureoutput
•Securethelidwithalockingscrew,iftherelayisconnectedtothe
mainspower
Display locking
jumper
Output mode
selecon
jumpers
Contact pins for
relay terminal
Contact pins for
terminal block
Terminal block
Terminal block for relay
99.0
90.0
83.0
49.5
14.0
45.0
18.0
Ø 4.0
32.0
YES NO NO
Figure 1b - Mounng orientaon
Copyright HK Instruments 2021 www.hkinstruments. Installaon version 7.0 2021
CAUTION!
•ForCEcompliance,aproperlygroundedshieldingcableis
required.
•Usecopperwireonly.Insulateorwirenutallunusedleads.
•Supplyaseparatecableforrelayandsignaloutwhenusingline
voltagetopowertherelay.
•Anywiringmaycarrythefulloperanglinevoltagecurrentbased
oneldinstallaon.Thecoverlockingscrewmustbeinstalledif
thelinevoltageissuppliedtotherelay.
•Careshouldbeusedtoavoidelectrostacdischargetothe
device.
•Thisunithasconguraonjumpers.Youmayneedtorecongure
thisdeviceforyourapplicaon.
1)Routethecablesthroughthesquareopeninginthebackplateor
forsurfacewiringselectaknockoutonthetoporboomofthe
wallplate,asshowninFigure2a.
2)ConnectthewiresasshowninFigure2band2c.
STEP 3: CONFIGURATION
WIRING DIAGRAMS CONTINUED
ConguraonoftheCDT-MOD-2000seriesdeviceconsistsof:
1)Conguringthejumpers(seestep4)
2)Conguraonmenuopons.(Displayversionsonly.Seethe
usermanualforfurtherdetails)
Figure 2a - Roung the cables
24 V
GND
A
B
Analog
+
Output 0/2–10 V / 4–20 mA
output
Figure 2b - Wiring diagram: Power input & signal output
Wires can be routed through the square opening in the back plate
Wires can be routed through the top knockouts
Wires can be routed through the boom knockouts
Figure 2d - Wiring diagram: Relay
NC
COM
NO
STEP 2: WIRING DIAGRAMS
NOTE!Whenusinglongconneconwiresitmaybenecessarytouseaseparate
GNDwireforvoltageoutputcurrenttopreventmeasurementdistoron.The
needforanextraGNDwiredependsonthecrossseconandlengthoftheused
conneconwires.Iflongand/orsmallcrossseconwiresareused,supplycur-
rentandwireresistancemaygenerateavoltagedropinthecommonGNDwire
resulnginadistortedoutputmeasurement.
24 V
GND
A
B
+
Analog
Output 0/2...10 V
V
output
Figure 2c - Wiring diagram: Extra GND wire
STEP 4: Jumper settings
(Grey colour indicates that a jumper is installed)
No jumper
Circuit open
Jumper installed
Circuit closed
Jumper stored
Figure 3 - Jumper installaon
1)Conguraonoftheoutputmodes:
Selecttheoutputmode,current(4–20mA)orvoltage(0–10V),
byinstallingjumpersasshowninFigure4.
Toselect2–10Voutputmodeonadisplayversionofthedevice:
First,select0–10Voutputbyjumper,thenchangethevoltage(V)
outputfrom0–10Vto2–10Vviatheconguraonmenu.Please
seetheusermanualformoredetails.
Copyright HK Instruments 2021 www.hkinstruments. Installaon version 7.0 2021
The seller is obligated to provide a warranty of ve years for the delivered
goods regarding material andmanufacturing. The warranty period isconsid-
eredtostartonthedeliverydateoftheproduct.Ifadefectinrawmaterialsora
produconawisfound,thesellerisobligated,whentheproductissenttothe
sellerwithoutdelayorbeforeexpiraonofthewarranty,toamendthemistake
athis/herdiscreoneitherbyrepairingthedefecveproductorbydelivering
freeofchargetothebuyeranewawlessproductandsendingittothebuyer.
Deliverycostsfortherepairunderwarrantywillbepaidbythebuyerandthe
returncostsbytheseller.Thewarrantydoesnotcomprisedamagescausedby
accident,lightning,oodorothernaturalphenomenon,normalwearandtear,
improperorcareless handling, abnormaluse,overloading,improperstorage,
incorrectcareorreconstrucon,orchangesandinstallaonworknotdoneby
thesellerorhis/herauthorizedrepresentave.Theseleconofmaterialsfor
devicespronetocorrosionisthebuyer’sresponsibility,unlessotherwiseisle-
gallyagreedupon.Shouldthemanufactureralterthestructureofthedevice,
thesellerisnotobligatedtomakecomparablechangestodevicesalreadypur-
chased.Appealingforwarrantyrequiresthatthebuyerhascorrectlyfullled
his/herduesarisenfromthedeliveryandstatedinthecontract.Theseller
willgiveanewwarrantyforgoodsthathavebeenreplacedorrepairedwithin
the warranty, however only to the expiraon of the original product’s war-
rantyme.Thewarrantyincludestherepairofadefecvepartordevice,orif
needed,anewpartordevice,butnotinstallaonorexchangecosts.Underno
circumstanceisthesellerliablefordamagescompensaonforindirectdamage.
Register Parameter descripon Data Type Value Range
4x0001 ParameterforP-controller 16bit 0...3 0=CO2,1=rH,2=TE,3=MAX
4x0002 CO2hIghlimit 16bit 500...2000 500...2000ppm
4x0003 CO2lowlimit 16bit 0...1900 0...1900ppm
4x0004 rHhighlimit 16bit 100...1000 10.0...100.0%
4x0005 rHlowlimit 16bit 0...900 0.0...90.0%
4x0006 TEhighlimit 16bit 50...500 5.0...50.0°C
4x0007 TElowlimit 16bit 0...450 0...45.0°C
4x0008 Parameter for relay 16bit 0...3 0=CO2,1=rH,2=TE,(3=O)
4x0009 CO2relayon 16bit 500...1950 500...1950ppm
4x0010 CO2relayo 16bit 450...1900 450...1900ppm
4x0011 rH relay on 16bit 15...990 1.5...99.0%
4x0012 rHrelayo 16bit 10...985 1.0...98.5%
4x0013 TE relay on 16bit 15...490 1.5...49.0°C
4x0014 TErelayo 16bit 10...485 1.0...48.5°C
Funconcode03-Readinputholdingregister
Funconcode04-Readinputregister
Register Parameter descripon Data Type Value Range
3x0001 ParameterforP-controller 16bit 0...3 0=CO2,1=rH,2=TE,3=MAX
3x0002 CO2reading 16bit 0...2000 0...2000ppm
3x0003 rHreading 16bit 0...1000 0,0...100.0%
3x0004 Temp.reading 16bit 0...500 0.0...50.0°C
3x0005 CO2highlimit 16bit 500...2000 500...2000ppm
3x0006 CO2lowlimit 16bit 0...1900 0...1900ppm
3x0007 rHhighlimit 16bit 100...1000 10.0...100.0%
3x0008 rHlowlimit 16bit 0...900 0.0...90.0%
3x0009 TEhighlimit 16bit 50...500 5.0...50.0°C
3x0010 TElowlimit 16bit 0...450 0...45.0°C
3x0011 Parameter for relay 16bit 0...3 0=CO2,1=rH,2=TE,(3=O)
3x0012 CO2relayon 16bit 500...1950 500...1950ppm
3x0013 CO2relayo 16bit 450...1900 450...1900ppm
3x0 014 rH relay on 16bit 15...990 1.5...99.0%
3x0015 rHrelayo 16bit 10...985 1.0...98,5%
3x0016 TE relay on 16bit 15...490 1.5...49.0°C
3x0017 TErelayo 16bit 10...485 1.0...48.5°C
MODBUS REGISTERS CONTINUED
Funconcode16-Writemulpleregisters
Register Parameter descripon Data Type Value Range
4x0001 ParameterforP-controller 16bit 0...3 0=CO2,1=rH,2=TE,3=MAX
4x0002 CO2hIghlimit 16bit 500...2000 500...2000ppm
4x0003 CO2lowlimit 16bit 0...1900 0...1900ppm
4x0004 rHhighlimit 16bit 100...1000 10.0...100.0%
4x0005 rHlowlimit 16bit 0...900 0.0...90.0%
4x0006 TEhighlimit 16bit 50...500 5.0...50.0°C
4x0007 TElowlimit 16bit 0...450 0...45.0°C
4x0008 Parameter for relay 16bit 0...3 0=CO2,1=rH,2=TE,(3=O)
4x0009 CO2relayon 16bit 500...1950 500...1950ppm
4x0010 CO2relayo 16bit 450...1900 450...1900ppm
4x0011 rH relay on 16bit 15...990 1.5...99.0%
4x0012 rHrelayo 16bit 10...985 1.0...98.5%
4x0013 TE relay on 16bit 15...490 1.5...49.0°C
4x0014 TErelayo 16bit 10...485 1.0...48.5°C
RECYCLING/DISPOSAL
The parts le over from installaon should be
recycled according to your local instrucons.
Decommissioned devices should be taken to a
recyclingsitethatspecializesinelectronicwaste.
WARRANTY POLICY
Register Parameter descripon Data Type Value Range
1x0001 Relay status Bit0 0...1 0=O-1=On
1x0002 Relaytrend Bit0 0...1 0=Increasing,1=Decreasing
1x0003 Timer status Bit0 0...1 0=O-1=On
Funconcode02-Readinputstatus
Funconcode06-Writesingleregister
Register Parameter descripon Data Type Value Range
4x0001 ParameterforP-controller 16bit 0...3 0=CO2,1=rH,2=TE,3=MAX
4x0002 CO2hIghlimit 16bit 500...2000 500...2000ppm
4x0003 CO2lowlimit 16bit 0...1900 0...1900ppm
4x0004 rHhighlimit 16bit 100...1000 10.0...100.0%
4x0005 rHlowlimit 16bit 0...900 0.0...90.0%
4x0006 TEhighlimit 16bit 50...500 5.0...50.0°C
4x0007 TElowlimit 16bit 0...450 0...45.0°C
4x0008 Parameter for relay 16bit 0...3 0=CO2,1=rH,2=TE,(3=O)
4x0009 CO2relayon 16bit 500...1950 500...1950ppm
4x0010 CO2relayo 16bit 450...1900 450...1900ppm
4x0011 rH relay on 16bit 15...990 1.5...99.0%
4x0012 rHrelayo 16bit 10...985 1.0...98.5%
4x0013 TE relay on 16bit 15...490 1.5...49.0°C
4x0014 TErelayo 16bit 10...485 1.0...48.5°C
STEP 5: MODBUS REGISTERS
FunconsforModbuscommunicaon:
Funcon Code Descripon
01 Readcoilstatus
02 Readinputstatus
03 Readholdingregisters
04 Readinputregisters
05 Forcesinglecoil
06 Presetsingleregister
07 Readexceponstatus
15 Forcemulplecoils
16 Presetmulpleregisters
17 ReportslaveID
Jumper settings CONTINUED
Funconcode05-Writesinglecoil
Register Parameter descripon Data Type Value Range
0x0001 Relaytrend Bit0 0...1 0=Increasing,1=Decreasing
Jumper installed to the le side pins:
0–10 V output selected
N/A
N/A
Analog
0...10 V 4...20 mA
Jumper installed to the right side pins:
4–20 mA output selected
N/A
N/A
Analog
0...10 V 4...20 mA
Figure 4
2)Lockingthedisplay:
Installthejumpertolockthedisplaytopreventaccesstothe
conguraonmenuaerinstallaoniscompleted(seethe
schemacsforthelocaonofthepins).

Other HK Instruments Transmitter manuals

HK Instruments DPT-R8 Series User manual

HK Instruments

HK Instruments DPT-R8 Series User manual

HK Instruments DPT-2W- 100-R2 User manual

HK Instruments

HK Instruments DPT-2W- 100-R2 User manual

HK Instruments RHT Series User manual

HK Instruments

HK Instruments RHT Series User manual

HK Instruments KLU 100 User manual

HK Instruments

HK Instruments KLU 100 User manual

HK Instruments RHT-MOD Series User manual

HK Instruments

HK Instruments RHT-MOD Series User manual

HK Instruments CMT Series User manual

HK Instruments

HK Instruments CMT Series User manual

HK Instruments AVT Series User manual

HK Instruments

HK Instruments AVT Series User manual

HK Instruments DPT-Flow-1000 Quick start guide

HK Instruments

HK Instruments DPT-Flow-1000 Quick start guide

HK Instruments RHT-MOD Duct Series User manual

HK Instruments

HK Instruments RHT-MOD Duct Series User manual

HK Instruments DPT-Dual-MOD Series User manual

HK Instruments

HK Instruments DPT-Dual-MOD Series User manual

HK Instruments DPT Series User manual

HK Instruments

HK Instruments DPT Series User manual

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments DPT-2W- 100-R2 User manual

HK Instruments

HK Instruments DPT-2W- 100-R2 User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

HK Instruments DPT2500-R8 Series Instruction manual

HK Instruments

HK Instruments DPT2500-R8 Series Instruction manual

HK Instruments DPT-Flow Series User manual

HK Instruments

HK Instruments DPT-Flow Series User manual

HK Instruments RHT Series User manual

HK Instruments

HK Instruments RHT Series User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

HK Instruments DPT-IO-MOD Series User manual

HK Instruments

HK Instruments DPT-IO-MOD Series User manual

HK Instruments Siro-MOD Series User manual

HK Instruments

HK Instruments Siro-MOD Series User manual

HK Instruments DPT-Priima Series User manual

HK Instruments

HK Instruments DPT-Priima Series User manual

HK Instruments DPT-MOD Series User manual

HK Instruments

HK Instruments DPT-MOD Series User manual

HK Instruments AVT Series User manual

HK Instruments

HK Instruments AVT Series User manual

HK Instruments CDT-MOD-2000 Duct Series User manual

HK Instruments

HK Instruments CDT-MOD-2000 Duct Series User manual

Popular Transmitter manuals by other brands

Telran communications OPIA00001 user manual

Telran communications

Telran communications OPIA00001 user manual

Absolute Process Instruments APD 7010 quick start guide

Absolute Process Instruments

Absolute Process Instruments APD 7010 quick start guide

Novus NP785-50 instruction manual

Novus

Novus NP785-50 instruction manual

Argos E0207TR-2 user manual

Argos

Argos E0207TR-2 user manual

Kannad AF INTEGRA installation manual

Kannad

Kannad AF INTEGRA installation manual

WIKA ls-10 operating instructions

WIKA

WIKA ls-10 operating instructions

Ameri-King AK-451 Series Installation and operation manual

Ameri-King

Ameri-King AK-451 Series Installation and operation manual

Wireless Devices WD2 Operation manual

Wireless Devices

Wireless Devices WD2 Operation manual

Audiovox S1BTXA Programming guide

Audiovox

Audiovox S1BTXA Programming guide

Hama RTR-10 Operating	 instruction

Hama

Hama RTR-10 Operating instruction

Sennheiser SZI 1015-T Instructions for use

Sennheiser

Sennheiser SZI 1015-T Instructions for use

Comet P3116 instruction manual

Comet

Comet P3116 instruction manual

Siemens SITRANS P DS III manual

Siemens

Siemens SITRANS P DS III manual

Lightware DVI-HDCP-TPS-TX210 quick start guide

Lightware

Lightware DVI-HDCP-TPS-TX210 quick start guide

Endress+Hauser iTEMP TMT125 operating instructions

Endress+Hauser

Endress+Hauser iTEMP TMT125 operating instructions

RKI Instruments 65-2330RK Operator's manual

RKI Instruments

RKI Instruments 65-2330RK Operator's manual

Rohde & Schwarz R&S SFE100 Getting started

Rohde & Schwarz

Rohde & Schwarz R&S SFE100 Getting started

Canon Wireless File Transmitter WFT-E2 II A instruction manual

Canon

Canon Wireless File Transmitter WFT-E2 II A instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.