
Installation and Setup Guide
- 8 -
6
66
641 Primary P one No.
Enter up to 12 digits
Do not fill unused spaces. To clear entries press *41*.
6
66
642 Secondary P one No.
Enter up to 12 digits
Do not fill unused spaces. To clear entries press *42*.
6
66
643 Subscriber Account No.
Enter 0-9, # + 11 for B; # + 12 for C; # + 13 for D; # + 14
for E; # + 1 for F; Enter * as 4th digit, if 3+1 dialer
reporting will be used.
If only 3 digits are being used, exit by pressing* (and
press 44, if entering next field). To clear entries press
*42*.
6
66
644 Report Format
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 =or unidentified = 4+2 ADEMCO EXPRESS
7 = ADEMCO Contact ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
Select format for primary/secondary phone numbers.
6
66
645 P one System Select †
If Central Station IS NOT on a WATS line:
0 = Pulse Dial; 1 = Tone Dial
If Central Station IS on a WATS line:
2 = Pulse Dial; 3 = Tone Dial
Select the type of telephone service
6
66
646 SESCOA/Radionics Select †
0 = Radionics (0-9, B-F reporting); 1 = SESCOA (0-9 only
reporting)
Select 0 for all other formats.
6
66
647 15 Second Dialer Delay (Burglary) †
0 = no; 1 = yes
Provides delay of Burglary report to Central Station.
6
66
648 Periodic Test Message †
0 = none; 1 = 24 hrs; 2 = weekly (enter Test Code in field *64)
(Initial report is sent 12 hrs after exiting programming
or downloading)
6
66
649 Split/Dual Reporting
To Primary P one No. To Secondary P one No.
0 = All Backup Report Only
1 = Alarms, Restore, Cancel Other Reports
2 = All Reports Except
Open/Close, Test
Open/Close, Test
3 = Alarms, Restore, Cancel All Reports
4 = All Reports Except
Open/Close, Test
All Reports
5 = All Reports (Dual Reporting All Reports
To Primary P one No. To Pager No. †† (secondary)
6 = All Reports Except
Open/Close
Alarms, Open/Close, Troubles
7 = All Reports Alarms, Troubles
8 = All Reports Alarms, Open/Close, Troubles
† Entering a number other than the one specified will give
unpredictable results.
†† Can only be used if primary reporting format is ADEMCO Contact D.
Used to select a reporting option as follows:
Enter: 0 - 5 when reporting to telephone receivers.
6 - 9 when reporting to a pager is desired.
Touch Tone codes for paging are defined as follows:
1911 = Alarm
1001 = Open
1002 = Close
1811 = Trouble
Note: Restore reports are not sent to the pager.
Programming Report Codes for Alarm System Status,
Restore *50-*74
For 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–
9, 0, B, C, D, E, or F. Enter #+10 for 0 (this reports a 0 on some
receivers), #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+1
for F.
For Expanded or 4+2 Format: Enter codes in both boxes (1st and
2nd digits) for 1–9, 0, B–F, as described above.
For ADEMCO Contact ID® Reporting: Enter any digit (other than
“0”) in the first box to enable the zone to report. This is an
“enabling” code only and is not the actual code sent to the Central
Station office. Entries in the second boxes are ignored. An entry of
0 in the first box disables the report.
An entry of 0 in t e first box disables a report.
Entering 0 in t e second box advance to t e
next field. An entry of 0 in t e second box will
result in automatic advancement to t e next field
w en programming. To send “0” as a digit you
must enter # +10.
Alarm Report Codes (6
66
650-6
66
659)
6
66
650 1st Digit of Zn95, Zn96 (Keypad Panics)
0 = No Report, 1-9, B-F (as described above).
2nd Digit of each (for expanded 4+2 reporting) is the
same as field *57.
Zone 95 is Console Silent Panic (Key A or 1 & *.)
Zone 96 is Console Audible Panic (Key C or 3 & #).
6
66
651 Zone 1 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
6
66
652 Zone 2 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
6
66
653 Zone 3 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
6
66
654 Zone 4 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
6
66
655 Zone 5 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
6
66
656 Zone 6 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
6
66
657 Zone 7 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
Console Panic: Key B or *+#