Honeywell Ademco VISTA-20P User manual


K5305-1QGV3 2/11 Rev. A

2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2009 Honeywell International Inc.
www.honeywell.com/security






(A copy of the Installation and Setup Guide is available upon request)

FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech (see instructions K5305-1V9 or higher)
These instructions apply to the following Honeywell security systems:
ADEMCO VISTA-20P, VISTA-20PSIA, VISTA-20PCN, VISTA-15P, VISTA-15PSIA, VISTA-15PCN
Features and procedures apply to all, except where differences are noted.
VISTA-20PSIA and VISTA-15PSIA are certified SIA-compliant controls that meet SIA specifications for
False Alarm Reduction.
Connect Devices, Zones, Sounder, and Phone Line.
Refer to the Wiring Diagram on the reverse side for connection information. NOTE: This system uses a range of reserved addresses for each type of device.
1. Connect keypads and other addressable devices to the ECP terminals 4-7.
Refer to the wiring chart below for wire sizes and maximum wire run lengths.
Wire Chart For Devices Drawing Aux Power From The Control (12V+ & 12V–)
Wire TOTAL CURRENT OF ALL DEVICES CONNECTED TO A SINGLE WIRE RUN
Size 50 mA or less 100 mA 300 mA 500 mA 600 mA
#22 900ft (274m) 450ft (137m) 150ft (46m) 90ft (27m) 75ft (23m)
#20 1400ft (427m) 700ft (213m) 240ft (73m) 140ft (43m) 120ft (37m)
#18 1500ft (457m) 1100ft (335m) 350ft (107m) 220ft (67m) 170ft (52m)
#16 1500ft (457m) 1500ft (457m) 550ft (168m) 350ft (107m) 270ft (82m)
The length of all wire runs for both partitions combined must not exceed 1500 feet (457m) when unshielded quad
conductor cable is used (750 feet if shielded cable is used).
Standard Keypads (6150 / 6160 series)
•Keypad addresses range from address 16-23. Set each keypad’s address accordingly.
NOTE: Address 16 is reserved for the first keypad and is always enabled in the control.
•Use data fields ∗190-∗196 to enable keypads and set their sounding options.
Expander Modules (4219, 4229)
•Connect desired field wiring to the module’s zone terminals.
•Expander module addresses range from 07-11. Set each module’s DIP address accordingly.
•Use ∗56 Menu mode to program zone characteristics.
Touchscreen Keypads (6270 / 6271 series, 8132 series; V20P = up to 4; V15P = up to 2)
•Use of touchscreen keypads is independent from and in addition to the eight (8) standard keypads.
•Set each touchscreen’s address accordingly (1, 2, 5, 6; see table on back) and enable in field ∗189.
•Make sure the auxiliary current drain is within the control’s limitation. Otherwise use an external
power supply to power the touchscreen keypads.
RF Receiver (5881, 5883, RF Keypad)
•5881L / 5882L = up to 8 RF zones; 5881M / 5882M / 6150RF = up to 16 RF zones
5881H / 5882H / 5883 / 6160RF = up to system maximum RF zones
•Set the receiver’s address to 00 using the module’s DIP switches.
•If using wireless keypads, set field ∗24 RF House ID Code appropriately.
If receiver is mounted remotely, note the following:
•Do not locate the receiver or transmitters on or near metal objects. This will decrease range and/or
block transmissions.
•Do not locate the RF receiver in an area of high RF interference (indicated by frequent or
prolonged lighting of the receiver’s LED; random flicker is OK).
•Do not locate RF receiver closer than 10 feet from any keypads.
Relay Modules (4204)
•Connect desired field wiring to the module’s relay contact terminals.
•Relay module addresses range from address 12-15.Set each module’s DIP address accordingly.
•Use ∗79 / ∗80 Menu modes to map each device address and define output functions.
Communication Device (7847i, 7845GSM, 7845i-GSM, GSMV)
•Set the communication device to address 03.
•Use ∗29 Menu mode to enable and program the device.
AVS System
•If used, follow the installation instructions provided with the module.
•Connect the AVS module to the control’s ECP terminals and connect all other ECP devices to the
AVS module’s ECP terminals.
•Set the AVS address using its DIP switches: V15P = 08; V20P = 11
•Use the desired AVS Quick Program Command to set pre-defined options:
installer code + [#] + 0 + 3: enable AVS operation
installer code + [#] + 0 + 4: enable AVS and enable panel sounds on AVST speaker
•Use field ∗55 Dynamic Signaling Priority to select the desired reporting paths.
2. Connect hardwire zones to the appropriate zone terminals 8-20.
3. On-Board Trigger Connections
•Connect field wiring to the appropriate trigger pin using the SA4120XM-1 cable (if using 1361X10
transformer) or the 4-wire cable (N4632-4, not supplied).
•Trigger outputs are normally high, and go low upon programmed condition (can be set inverted).
•Use ∗79/∗80 Menu modes to program the trigger outputs.
•Output 17 (pin 1) = supports up to 100mA max; Output 18 (pin 5) = supports up to 20mA max
4. Install Wireless Zone Transmitters.
•Use ∗56 Menu mode to program wireless zones and enroll the transmitters.
•Use the Go/No Go Test mode to verify adequate signal strength from each transmitter location:
Enter Installer code + [#] + 4, then fault each transmitter and listen for 3 beeps at the keypad and
the zone display. Exit mode: user code + 1 (OFF).
5. Connect the external sounder to terminals 3 and 4.
•If supervised output desired, see Sounder Supervision wiring diagram on reverse side, and set field
∗91 Option Selection for Bell Supervision.
6. Connect the phone line using terminals 21-24.
•Use an RJ31X jack as shown in the diagram on reverse side.

Mount the Control.
1. Remove the cabinet door. Remove the cabinet
knockouts needed for wiring entry.
2. Mount the control cabinet to a sturdy wall in a
clean, dry area, which is not readily accessible to
the general public, using fasteners or anchors (not
supplied) with the four cabinet mounting holes.
3. When installation and wiring is completed, install
the cabinet door and secure by using 2 screws
(supplied) through the door's edge.
OPTIONAL KEY LOCK: If desired, a key lock can be
installed (K4445, not supplied). See Installation
Instructions for details.
cab_6a-V0
SECURE
WITH
SCREWS
(2)
Securing the Cabinet Door
4. Mount the PC Board. Refer to the diagram below. If mounting an RF Receiver inside the cabinet,

remove the receiver board from its case, then insert the top of the board into the slots at the top of the
cabinet. Install the control board below the receiver board using the clips and screws provided. Insert
grounding lugs into the left-hand terminals of the antenna blocks and secure them with the screws
provided. Insert the receiver's antennas into the blocks' right-hand terminals, and tighten the screws.
+
+
CIRCUIT
BOARD
INSERT THE TOP OF THE
CIRCUIT BOARD INTO THE
SLOTS AT THE TOP OF THE
CABINET
DETAIL B
SIDE VIEW
OF MOUNTING CLIPS
DETAIL A
SIDE VIEW
OF BOARD SUPPORTING
SLOTS
CIRCUIT
BOARD
cb_mount-001-V1
CABINET
CABINET
HANG TWO SHORT MOUNTING CLIPS
(PROVIDED) ON THE RAISED CABINET TABS.
SECURE THE BOARD TO THE
CABINET WITH THE ACCOMPANYING
SCREWS
Mounting the PC Board
Connect the Transformer & Battery.
1321 Transformer (1321CN in Canada)
•Do not plug the transformer into the AC outlet until all wiring connections to the control are complete. As
a safety precaution, always power down the control when making such connections.
1361X10 Transformer
(required if using Powerline Carrier devices)
1. Splice one end of a 3-conductor cable to the wire ends of the SA4120XM-1 cable.
2. Connect the SA4120XM-1 cable plug to the 8-pin connector on the control.
3. Connect the other end of the 3-conductor cable to the 1361X10 Transformer.
Canadian Installations: For Powerline Carrier Devices, use the PSC04 X-10 Interface and trigger pins.
Battery Connections
•After all connections to the control are completed and after AC power has been applied, connect the
red and black flying leads on the control board to the battery.
•IMPORTANT: This control will not power-up on battery alone (AC power must be applied). However,
once the system is powered up, it will operate on battery if AC is lost.
UL

For UL installations and Residential fire installations, refer to the chart below for the correct battery
size required to meet the mandatory standby time.
CALIFORNIA STATE FIRE MARSHALL (CSFM) AND UL RESIDENTIAL FIRE
24-HOUR BATTERY BACKUP REQUIREMENTS
The California State Fire Marshal and UL have regulations which require that all residential fire alarm
control panels must be provided with a backup battery which has sufficient capacity to operate the panel
and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4
minutes in the intended fire alarm signaling condition. This control panel can meet these requirements
without using a supplementary power supply, provided that the panel’s auxiliary power and bell output
currents are limited as listed below.
OUTPUT LIMITATIONS AND REQUIRED BATTERIES
OUTPUT CURRENT LIMITS BATTERY INFORMATION
Current Total
600mA
maximum total of
auxiliary power
plus bell output
currents
Max. Aux.Current
45mA
160mA
200mA
425mA
500mA
Battery Capacity (Amp/Hrs)
4AH
7AH
8AH
14AH
17.2AH
Recommended Battery (Yuasa No.)
NP4-12 (or ADEMCO 467)
NP7-12
NP4-12 (two) ‡
NP7-12 (two) ‡
NPG18-12
‡
NOTE: Use two batteries, connected in parallel. Obtain an Ademco Battery Harness Kit SA5140-1. (Both batteries will
fit inside the cabinet.)
Program the Control.
Refer to the Programming Guide to program the control.
(
The control can also be programmed via the Compass Downloader.)
1. Enter Programming Mode: installer code + 8-0-0.
2. Change the default Installer Code using field ∗20.
3. Enter the appropriate central station phone numbers and account numbers.
4. Program the system data field options as desired.
4. Use the various menu modes to program zones, relay outputs, descriptors, etc.
5. If AVS system is installed, use the appropriate AVS Quick Program Command.
6. Program Schedules (if used): Master code + [#] + 64
7. Enable RF button keyfobs (if used) and assign to user numbers accordingly.
8. Show the Master user how to change the default Master code:
master code + [8] + 0-2 + new code + new code again
Test the System.
Sniffer Mode Test: To verify that all transmitters have been properly programmed, disarm all partitions.
1. From a keypad in partition 1, enter Installer code + [#] + 3. All programmed transmitters are displayed.
2. Fault all transmitters in turn. The display clears each transmitter as a signal is received.
3. Exit Sniffer mode: Installer code + 1 (OFF). Mode does not automatically expire; you must exit manually.
System Test
1. Disarm the system and close all protected windows, doors, etc.
2. Enter the Installer code + [5] (TEST), then press 0 = walk. (Option 1 = Dial checks phone line integrity.)
3. Listen. The external sounder should sound for about 1 second then turn off.
4. Fault all zones in turn and listen for three beeps from the keypad. ID of each faulted point should
appear on the keypad display. The display clears when the zone is restored.
5. Test all smoke and CO detectors following the manufacturer's instructions and check the display.
6. When all zones have been checked and are intact (closed), there should be no zone identification
numbers displayed on the keypad.
7. Exit test mode: security code + [1] (OFF).
Major Features and Capacities
Feature VISTA-20P VISTA-15P
Partitions 2 plus common area not partitioned
Zones 48 plus 16 keyfob zones for
total of 64 zones:
•8 hardwired zones (1-8)
•Up to 40 additional wired
zones (9-48) using up to 5
4219/4229 modules
•Up to 40 wireless zones
(5800 series; zones 9-48)
•4 configurable zone types
32 zones plus 8 keyfob zones
for total of 40 zones:
•6 hardwired zones (1-6)
•Up to 16 additional wired
zones (9-24) using up to 2
4219/4229 modules
•Up to 26 wireless zones
(5800 series; zones 9-34)
•2 configurable zone types
Security Codes 48 32
Schedules 32 8
Keypad macros 4 2
Event Logging 100 50
Paging 4 2
Keypads 8 8
Touch Screen Devices 4 2
4219, 4229 5 2
4204 4 2
Output Relays / X-10 devices
16 8
On-Board Triggers 2 2
Output Functions 48 24

WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa



HARDWIRE ZONE CONNECTION
AC POWER CONNECTIONAC POWER CONNECTION
GND Z5Z4GNDZ3Z2GNDZ1+OUTINAUXAC
RED
GREEN
GRAY
BROWN
AC BELL GND GNDRINGTIPRING
INCOMING
HANDSET
TIPZ8GND Z6 Z7
1237811 12 17 20 21 22 23
18 19
16
15
1413
10
9
6
45
Z1
EARTH
GROUND
AFTER ALL WIRING CONNECTIONS ARE COMPLETE, PLUG
TRANSFORMER INTO A 110VAC UNSWITCHED OUTLET (24HR).
USE 1361X10 TRANSFORMER INTERFACE WHEN POWER
LINE CARRIER DEVICES ARE BEING USED.
BLACK
RED
2-WIRE SMOKE
DETECTORS
(16 MAX) OR
STANDARD
2K EOLR
PREMISES
PHONES
INCOMING
TELCO
RING (GRAY)
TIP (BROWN)
RING (RED)
TIP GREEN)
RJ31X
1 2 3
4
5
67
8
ZONE
PAIRS
2 / 10
3 / 11
4 / 12
5 / 13
6 / 14
7 / 15
8 / 16
1312 14
6.2k
ZONE 10
3k
ZONE 2
2k
2k
2k
ZONE 3
2k
2k
2k
ZONE 4
1321
(1321CN IN CANADA)
16.5VAC, 25VA, CLASS 2
PLUG-IN TRANSFORMER
RECHARGABLE
BATTERY
(12V, 4AH)
SEALED LEAD
ACID TYPE
TRANSFORMER WIRE RUNS
"AC LOSS" DISPLAYED IF VOLTAGE FALLS BELOW 16.5VAC.
CONNECT THE TRANSFORMER TO TERMINALS 1 AND 2.
SEE WIRE RUN CHART.
Distance from control Wire Size
# 18
# 16
# 20
50 - 100 feet
100 - 200 feet
Up to 50 feet
HARDWIRE ZONES
ECP DEVICES
PLACE THE 12-VOLT BACKUP BATTERY IN THE CABINET.
AFTER ALL CONNECTIONS TO THE CONTROL ARE MADE AND
AFTER AC POWER HAS BEEN APPLIED, CONNECT THE RED AND
BLACK FLYING LEADS TO THE BATTERY.
ZONE DOUBLING
VISTA-20P ONLY
DOUBLE-BALANCED ZONE
VISTA-20P ONLY
UL NOTE:
SET RECEIVER DEVICE ADDRESS TO "00" (SET SWITCHES TO
THE RIGHT, "OFF" POSITION).
MOUNT THE RECEIVER INSIDE THE CABINET OR REMOTELY
WITHIN A NOMINAL RANGE OF 200 FEET FROM TRANSMITTERS,
IN A HIGH, CENTRALLY LOCATED AREA.
CONNECT THE RECEIVER'S WIRE HARNESS TO THE CONTROL'S
ECP TERMINALS. SEE RECEIVER'S INSTRUCTIONS FOR
ANTENNA MOUNTING, ETC.
INSTALL TRANSMITTERS ACCORDING TO THEIR INSTRUCTIONS.
26 TRANSMITTER ZONES: 9-34
8 BUTTON ZONES: 49-56
40 TRANSMITTER ZONES: 9-48
16 BUTTON ZONES: 49-64
WIRELESS ZONE NUMBERS
DO NOT USE DOUBLE-BALANCED ZONES
OR ZONE DOUBLING FOR FIRE ZONES.
OPEN CIRCUIT DEVICES CONNECT IN PARALLEL ACROSS
THE LOOP; FOR EOLR ZONES, CONNECT THE EOLR
ACROSS THE LOOP WIRES AT THE LAST DEVICE.
CLOSED CIRCUIT DEVICES CONNECT IN SERIES IN THE
HIGH (+) SIDE OF THE LOOP; FOR EOLR ZONES, CONNECT
THE EOLR IN SERIES FOLLOWING THE LAST DEVICE.
1.
2.
PROVIDES TWO HARDWIRED
N.C. ZONES FOR EACH
STANDARD HW ZONE
(BUT DOES NOT INCREASE
TOTAL NUMBER OF ZONES
SUPPORTED). A SHORT ACROSS
THE EOL ON EITHER ZONE
CAUSES A TAMPER CONDITION.
ZONE NUMBERS USED FOR
DOUBLING CANNOT BE USED
FOR ANYTHING ELSE.
PROVIDES ZONE TAMPER
PROTECTION AND SHOULD BE
USED AS BURGLARY ZONES ONLY.
A SHORT ACROSS THE EOL
CAUSES A TAMPER CONDITION.
FOR UL COMMERCIAL BURGLARY ALARM INSTALLATIONS,
USE EOLR ZONES.
EOLR NOTE:
IF THE EOLR IS NOT AT THE END OF THE LOOP, THE
ZONE IS NOT PROPERLY SUPERVISED AND THE SYSTEM
MAY NOT RESPOND TO AN "OPEN" ON THE ZONE.
USE CAUTION WHEN WIRING
THE TRANSFORMER TO THE
CONTROL TO GUARD AGAINST
BLOWING THE TRANSFORMER
FUSE (THE FUSE IS
NON-REPLACEABLE).
SOUNDER CONNECTION
RF RECEIVERS & TRANSMITTERS
AC POWER AND BATTERY CONNECTION
1.
2.
PHONE CONNECTION
CONNECT PHONE LINE DIRECT
CONNECT CABLE WIRES TO
TERMINALS 21-24 AS SHOWN.
WIRE COLORS REPRESENT THE
COLORS OF THE CABLE TO THE
RJ31X JACK.
CONNECT INCOMING PHONE
LINE AND HANDSET WIRING TO
THE MAIN TERMINAL BLOCK
(VIA AN RJ31X JACK; CA38A IN
CANADA) AS SHOWN.
1.
2.
EARTH GROUND CONNECTION
KEYSWITCH WIRING CONNECTIONS
METAL COLD WATER PIPE: USE A NON-CORROSIVE METAL STRAP
(COPPER IS RECOMMENDED) FIRMLY SECURED TO THE PIPE TO WHICH
THE GROUND LEAD IS ELECTRICALLY CONNECTED AND SECURED.
AC POWER OUTLET GROUND: AVAILABLE FROM 3-PRONG, 120VAC
POWER OUTLETS ONLY. TO TEST THE INTEGRITY OF THE GROUND
TERMINAL, USE A 3-WIRE CIRCUIT TESTER WITH NEON LAMP
INDICATORS, SUCH AS THE UL LISTED IDEAL MODEL 61-035, OR
EQUIVALENT, AVAILABLE AT MOST ELECTRICAL SUPPLY STORES.
THIS CONTROL DOES NOT NORMALLY NEED AN EARTH GROUND. IF
DESIRED FOR ADDITIONAL PROTECTION, CONNECT TERMINAL 25 TO A
GOOD EARTH GROUND. EXAMPLES OF GOOD EARTH GROUNDS:
16 - 23
07 - 11
12 - 15
00
5800TM
COMM DEVICE
4286
TOUCH SCREENS
28 (PART. 1 ONLY)
03
04
V15P: 1, 2
V20P: 1, 2, 5, 6
KEYPADS
4219, 4229
4204
RF RECEIVER
KEYPADS AND ADDRESSABLE DEVICE CONNECTION
V15P_V20P_quick-guide_CL
78
GND
+12 AUX
1 2 3 4 5 6
OUTPUT 18
(TRIG. 2)
OUTPUT 17
(TRIG. 1)
ZONE 1
HI
HI
LO
HI
LO
LO
2000
OHMS
EOLR
2000
OHMS
EOLR
ZONE 2
2000
OHMS
EOLR
ZONE 3
HI
HI
LO
LO
2000
OHMS
EOLR
ZONE 6
HI
HI
LO
LO
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
ZONE 4
ZONE 8
2000
OHMS
EOLR
ZONE 7
ZONE 5
YELLOW
GREEN
RED
BLACK
YELLOW
GREEN
RED
BLACK
1.
2.
FOR SOUNDER SUPERVISION
BATTERY
TRANSFORMER
1.
2.
3.
4.
IF BELL SUPERVISION IS
ENABLED ( 91 ENABLED)
CONNECT AN 820 OHM
RESISTOR ACROSS THE
EXTERNAL SOUNDER AS
SHOWN BY THE DOTTED LINE.
CONNECT SOUNDER TO BELL TERMINALS 3 (+) AND 4 (-).
SOUNDER ACTIVATES UPON ALARM EVENT.
ALARM OUTPUT: 10.5–13.8VDC, 2A MAX. (600mA MAX. FOR
UL USAGE, INCLUDING AUX POWER).
STEADY FOR BURGLARY/PANIC.
TEMPORAL PULSE SOUNDING FOR FIRE.
UL: MUST BE A UL LISTED AUDIBLE SIGNAL APPLIANCE RATED
FOR 10.2-13.8 VDC AND BE MOUNTED INDOORS.
CAN USE ADEMCO No. 702 SIREN, OR 12V BELL.
A BATTERY MUST BE INSTALLED BECAUSE THE BATTERY
SUPPLIES THE SOUNDER CURRENT.
EXTERNAL ALARM SOUNDER
820 OHM
EOL
RESISTOR
OBSERVE
POLARITY
TERM 3
TERM 4
DO NOT CONNECT THE RESISTOR DIRECTLY TO THE ALARM OUTPUTTERMINALS!
10.5-13.8VDC 600mA MAX.
(500mA MAX. FOR UL INSTALLATIONS)
OPTIONAL
1361X10
TO
TERMINALS
1 & 2 BLACK (SYNC)
BLUE (DATA)
PURPLE (COM)
78
1 2 3 4 5 6
ECP AUX POWER OUTPUT
SETTING KEYPAD ADDRESS
POWER UP THE KEYPAD. WITHIN 60 SECONDS OF
POWER-UP, PRESS AND HOLD DOWN THE [1] & [3] KEYS
AT THE SAME TIME FOR 3 SECONDS.
1.
2.
3.
ENTER THE PROPER "TENS" DIGIT OF THE KEYPAD'S
ADDRESS, THEN ENTER THE PROPER "ONES" DIGIT
OF THE KEYPAD'S ADDRESS.
PRESS [ ] TO SAVE THE DISPLAYED ADDRESS AND
EXIT ADDRESS MODE.
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
6
BYPASS
9
CHIME
#
ARMED
READY
1
OFF
3
STAY
HOLD
DOWN
THREE
SECONDS
4146 KEYSWITCH
(READY)
GREEN
LOCK
SWITCH (N. O.)
TAMPER
SWITCH (N. C.)
(ARMED)
RED
YELLOW
WHITE
2K OHM EOLR
11
10
TYPICAL ZONE
ON CONTROL
BOARD
BROWN
BLUE
BROWN
BLUE
820
ohms
820
ohms
STANDARD
KEYPAD
CABLE
+12 AUX. (RED)
OUTPUT 17 (YEL)
OUTPUT 18 (GRN)
RED
BLACK
SENSORS
(USE 1K EOLR)
4219/4229
EXPANDER
MODULE
RF
RECEIVER
COMMUNICATION
DEVICE
4204
RELAY
MODULE
KEYPAD
CONTROLLED
DEVICES
TRIGGER CONNECTOR
NOTE: FIRST KEYPAD IS ADDRESS 16
DIRECT CONNECT CORD (620)
4-WIRE SMOKE DETECTOR CONNECTIONS
(+)
+
2000
OHMS
EOLR
HEAT
DETECTOR
RED
EOL
POWER
SUPERVISION
RELAY MODULE
EOLR-1.
USE N.O.
CONTACT,
WHICH CLOSES
WHEN POWER
IS APPLIED.
VIOLET
AUX PWR
OUTPUT
TERMINALS
5
4
+
BLK
( )
TO ZONE 2 8 TERM.
RELAY
CONTACT OPENS MOMENTARILY
UPON FIRE ALARM RESET
PROGRAM RELAY
AS ZONE TYPE 54
(FIRE ZONE RESET)
+
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
N.C. N.O.
TO OUTPUT 17
PROGRAM OUTPUT 17 FOR
"OUT NORM LOW" = YES IN
79 MENU MODE AND AS ZONE
TYPE 54 IN 80 MENU MODE
MAX. CURRENT = 100 mA
OR
ARMED
READY
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
IMPORTANT: THE PANEL WILL NOT POWER UP INITIALLY ON
BATTERY POWER ONLY.YOU MUST PLUG THE TRANSFORMER
IN FIRST, AND THEN CONNECT THE BATTERY.
UL: BELL SUPERVISION IS REQUIRED
FOR FIRE ALARM INSTALLTIONS.
ULC NOTE: THE RF SUPERVISION PERIOD FOR THE V20PCN AND
V15PCN IS THREE HOURS FOR FIRE ZONES (ZT 9 AND 16) AND
12 HOURS FOR ALL OTHER ZONE TYPES.
DEVICE ADDRESS DEVICE ADDRESS
UL: PLC DEVICES AND 1361X10
ARE NOT UL LISTED FOR FIRE
OR BURGLARY FUNCTIONS
AND ARE INTENDED FOR
HOME AUTOMATION.
CANADA: USE PSC04.
SEE INSTALLATION INSTRUCTIONS.
UL: SEE INSTALLATION INSTRUCTIONS
FOR USAGE AND LIMITATIONS.
24 25
VISTA-20P ONLY
BATTERY FUSE (IF INSTALLED)
FOR REPLACEMENT,
USE SAME VALUE
(e.g. ADEMCO No. 90-12)
FUSE NOTE
MAY HAVE PTC IN
PLACE OF FUSE.
3A
1.
2.
CONNECT KEYPADS AND OTHER ADDRESSABLE DEVICES TO ECP TERMINALS 4-7.
(SEE "SETTING KEYPAD ADDRESS" BOX TO SET KEYPAD ADDRESSES.)
TOUCHSCREEN KEYPAD
(SEE TOUCHSCREEN
NOTE BELOW)
SET EACH MODULE'S ADDRESS ACCORDINGLY:
TOUCHSCREEN NOTE: TOUCHSCREEN KEYPADS MAY REQUIRE AN EXTERNAL
POWER SUPPLY DUE TO AUX POWER LIMITATIONS.
TRIGGER CONNECTOR
USED FOR 1361X10
TRANSFORMER
CONNECTIONS AND FOR
ON-BOARD TRIGGERS.
OUT 17 = 100mA MAX
OUT 18 = 20mA MAX
(USE SA4120XM-1 CABLE)
VISTA-20P VISTA-15P
RESISTORS NOT SUPPLIED
10 11


Other manuals for Ademco VISTA-20P

6

This manual suits for next models

7

Other Honeywell Security System manuals

Honeywell Fire-Lite Alarms ANN-80 Series Technical manual

Honeywell

Honeywell Fire-Lite Alarms ANN-80 Series Technical manual

Honeywell Vista 21IP User manual

Honeywell

Honeywell Vista 21IP User manual

Honeywell LYNX TOUCH L5200 Operating instructions

Honeywell

Honeywell LYNX TOUCH L5200 Operating instructions

Honeywell GENT Xenex Product guide

Honeywell

Honeywell GENT Xenex Product guide

Honeywell SEF8MA User manual

Honeywell

Honeywell SEF8MA User manual

Honeywell RWD21 User manual

Honeywell

Honeywell RWD21 User manual

Honeywell MAXPRO MPIP2000U Series Assembly instructions

Honeywell

Honeywell MAXPRO MPIP2000U Series Assembly instructions

Honeywell Gamewell-FCI Velociti MS-7AF User manual

Honeywell

Honeywell Gamewell-FCI Velociti MS-7AF User manual

Honeywell ADEMCO VISTA-48A User manual

Honeywell

Honeywell ADEMCO VISTA-48A User manual

Honeywell LYNX TouchL5200 Series User manual

Honeywell

Honeywell LYNX TouchL5200 Series User manual

Honeywell Ademco Lynx Touch User manual

Honeywell

Honeywell Ademco Lynx Touch User manual

Honeywell Gamewell-FCI E3 Series User manual

Honeywell

Honeywell Gamewell-FCI E3 Series User manual

Honeywell MK V User manual

Honeywell

Honeywell MK V User manual

Honeywell Galaxy 2-44+ User manual

Honeywell

Honeywell Galaxy 2-44+ User manual

Honeywell L5200 Series Operating instructions

Honeywell

Honeywell L5200 Series Operating instructions

Honeywell Ademco VISTA-20P Operating instructions

Honeywell

Honeywell Ademco VISTA-20P Operating instructions

Honeywell SEF800HF User manual

Honeywell

Honeywell SEF800HF User manual

Honeywell Fire Lite Alarms SWIFT Datasheet

Honeywell

Honeywell Fire Lite Alarms SWIFT Datasheet

Honeywell Ademco VISTA-50P Operating instructions

Honeywell

Honeywell Ademco VISTA-50P Operating instructions

Honeywell 2202 User manual

Honeywell

Honeywell 2202 User manual

Honeywell VISTA-250FBPT Assembly instructions

Honeywell

Honeywell VISTA-250FBPT Assembly instructions

Honeywell X-618 User manual

Honeywell

Honeywell X-618 User manual

Honeywell Code Encryptor II User manual

Honeywell

Honeywell Code Encryptor II User manual

Honeywell VISTA-128FBP User manual

Honeywell

Honeywell VISTA-128FBP User manual

Popular Security System manuals by other brands

HailBrain ProGuard800 Series Quick installation guide

HailBrain

HailBrain ProGuard800 Series Quick installation guide

Neugent LP-04120 installation manual

Neugent

Neugent LP-04120 installation manual

GST C-9403 quick start guide

GST

GST C-9403 quick start guide

IRIS Care Pendant user guide

IRIS

IRIS Care Pendant user guide

DSC Power 832 installation manual

DSC

DSC Power 832 installation manual

ALC SecuFirst ALM314S quick start guide

ALC

ALC SecuFirst ALM314S quick start guide

Texecom Veritas installation manual

Texecom

Texecom Veritas installation manual

GE Telligence Patient-Staff Communications... Operation manual

GE

GE Telligence Patient-Staff Communications... Operation manual

ADEMCO VISTA user manual

ADEMCO

ADEMCO VISTA user manual

Detex EA-500 installation instructions

Detex

Detex EA-500 installation instructions

Sony DVP-NW50 - In-wall Dvd Player Installer manual

Sony

Sony DVP-NW50 - In-wall Dvd Player Installer manual

Vimar By-alarm 01703.DE quick start guide

Vimar

Vimar By-alarm 01703.DE quick start guide

Jasco 45245 user manual

Jasco

Jasco 45245 user manual

Ikegami MAXI-VIEW III Operating instructions manual

Ikegami

Ikegami MAXI-VIEW III Operating instructions manual

AKO AKO-52062 manual

AKO

AKO AKO-52062 manual

American Dynamics Intellex Ultra Specifications

American Dynamics

American Dynamics Intellex Ultra Specifications

Defender 2K product manual

Defender

Defender 2K product manual

Call Aid UK 1142RX Operation & maintenance manual

Call Aid UK

Call Aid UK 1142RX Operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.