The Fire•Lite® SWIFT® addressable pull station is a dual-action,
manual pull station with a key-lock reset feature that provides one
addressable alarm initiating input. The pull station features similar
aesthetic design and durable construction characteristics as the
wired counterpart to blend seamlessly throughout the environment.
The device communicates to the Fire Alarm Control Panel (FACP)
through the SWIFT mesh network and gateway, and is powered by 4
batteries offering a 2-year, UL listed battery life.
Installation is fast and straightforward by using a mounting plate that
can be surface mounted. Once the mounting plate is firmly attached
to the wall, the pull station is snapped into place and locked down
with 3 screws.
The mechanical operation is simple and easy to use in an emer-
gency with a PUSH IN/PULL DOWN handle that latches in the down
position to clearly indicate the station has been operated while the
word “ACTIVATED” appears on top of the handle in bright yellow, fur-
ther indicating the operation of the station.
The wireless pull station meets the Americans with Disabilities Act
Accessibility Guidelines’ (ADAAG) controls and operating mecha-
nisms guidelines (section 4.1.3[13]) and the Americans with Disabil-
ities Act (ADA) requirement for a 5-pound maximum pull force to
activate the pull station and conforms to ANSI/UL Standard 38.
The SWIFT wireless system offers intelligent (addressable) devices
which provide secure, reliable communication to the FACP across a
Class A mesh network. Wireless devices create an opportunity for
applications where it is costly (concrete walls/ceilings, buried wires),
obtrusive (surface mount conduit), or possibly dangerous (asbestos)
to use traditional wired devices. In addition, both wired and wireless
devices can be present on the same FACP providing an integrated
wired-wireless solution for increased installation potential.
The mesh network within the SWIFT system creates a child-parent
relationship between the devices so that each device has two par-
ents providing a second path for communications on every device. If
one device can no longer operate for any reason, the rest of the
devices can still communicate with each other, directly or through
one or more intermediate devices. Once an initial mesh network is
formed, mesh restructuring automatically occurs to find the stron-
gest paths possible within the network.
The SWIFT system also engages frequency hopping to prevent sys-
tem interference whether intentional or accidental.
Features
• Easy, fast, wireless installation
• Participates in a Class A mesh network
• Built-in tri-color LED, which is visible through the handle of the
station, flashes in normal operation and latches steady red when
in alarm
• Handle latches in down position and the word “ACTIVATED”
appears to clearly indicate the station has been operated
• Maintenance personnel can open station for inspection and
address setting without causing an alarm condition
• Standard “code wheel” for setting the SLC address
• For use in commercial applications
• Smooth dual-action design
• Meets ADAAG controls and operating mechanisms guidelines
(Section 4.1.3[13]); meets ADA requirement for 5lb. maximum
activation force.
• Meets UL 38, Standard for Manually Actuated Signaling Boxes
• Highly visible
• Made of durable polycarbonate material
• Attractive shape and textured finish
•Keyreset
• Includes Braille text on station handle
Compatible Control Panels
NOTE: Refer to panel documentation for UL/ULC compatibility.
• ES-50X/C
• ES-200X/C
• MS-9200UDLS (UL applications)
• MS-9600(UD)LS(UL applications)
Fire•Lite® Alarms, Honeywell®, System Sensor®, and SWIFT® are registered
trademarks and LiteSpeed™ is a trademark of Honeywell International, Inc.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation.
Duracell® is a registered trademark of Duracell U.S. Operations Inc. Panasonic® is
a registered trademark of Panasonic Corporation.
©2022 by Honeywell International Inc. All rights reserved. Unauthorized use of this
document is strictly prohibited.
Page 2of 2 — DF-61055:C • 3/7/2022
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.
www.firelite.com Country of Origin: Mexico
SYSTEM SPECIFICATIONS
Electrical and Physical Specifications
Maximum Transmit RF Power: 17 dBm
Radio Frequency Range: 902-928 MHz
Temperature Range: 32°F to 120°F (0°C to 49°C)
Humidity: 10% to 93% Non-condensing
Battery Type: 4 Panasonic® CR123A or 4 Duracell® DL123A
Battery Life: 2 year minimum
Battery Replacement: Upon TROUBLE BATTERY LOW display
and/or during annual maintenance
Dimensions: 5.6" (142 mm) H x 4.2" (107 mm) W x 2.1" (53 mm) D
Components and Ordering Information
NOTE: Order “A” models for ULC applications.
•W-BG12LX(A): Wireless addressable pull station. Requires (4)
CR-123A batteries (included).
•W-BG12LXSP: Wireless addressable pull station. Spanish text.
Requires (4) CR-123A batteries (included).
•W-GATE(A): Fire•Lite Wireless SWIFT Gateway - 1 SWIFT Gate-
way is required for each wireless mesh, and supports up to 48
SWIFT detectors or modules. Connects to the SLC loop of a com-
patible panel using LiteSpeed protocol. Power may be supplied
by the SLC circuit or via an optional 24VDC input. See DF-60821
for other components available for use with the SWIFT Gateway.
NOTE: Use of the 24VDC input may be more convenient for service
as it allows for powering down a gateway without shutting down an
SLC loop.
•W-BATCART: Wireless battery cartridge, 10-pack.
•SMB500-WH: Optional surface-mount backbox.
Agency Listings and Approvals
The file number(s) below reference the specific listings for the
W-BG12LX(A) &
W-BG12LXSP. In some cases, certain modules or applications
may not be listed by certain approval agencies, or listing may be
in process. Consult Fire•Lite for latest listing status.
•UL Listed: S711
•ULC Listed: S711
•CSFM: 7150-0075:0503
•FCC ID: AUBWFSPS
•NYC Fire Dept: COA #6252, #6253, 6261
•FMApproved
Each device complies with part 15 of the FCC rules meaning opera-
tion is subject to the following two conditions: 1) The device may not
cause harmful interference and 2) The device must accept any inter-
ference received including interference that may cause undesired
operation.
Standards and Codes
The SWIFT Wireless pull station complies with the following UL
Standards and with NFPA 72 Fire Alarm system requirements.
• UL 864
• UL 268
• ULC S528

This manual suits for next models

1

Other Honeywell Security System manuals

Honeywell 013002 User manual

Honeywell

Honeywell 013002 User manual

Honeywell ADEMCO LYNXR Series Assembly instructions

Honeywell

Honeywell ADEMCO LYNXR Series Assembly instructions

Honeywell Domonial User manual

Honeywell

Honeywell Domonial User manual

Honeywell ADEMCO VISTA-48A Assembly instructions

Honeywell

Honeywell ADEMCO VISTA-48A Assembly instructions

Honeywell RCWL200A User manual

Honeywell

Honeywell RCWL200A User manual

Honeywell LYNX Touch L7000 Series User manual

Honeywell

Honeywell LYNX Touch L7000 Series User manual

Honeywell Galaxy 8 User manual

Honeywell

Honeywell Galaxy 8 User manual

Honeywell Ademco VISTA-20P User manual

Honeywell

Honeywell Ademco VISTA-20P User manual

Honeywell INTELLIGUARD 9000 User manual

Honeywell

Honeywell INTELLIGUARD 9000 User manual

Honeywell ADEMCO 6150V User manual

Honeywell

Honeywell ADEMCO 6150V User manual

Honeywell LYNX Touch 7000 User manual

Honeywell

Honeywell LYNX Touch 7000 User manual

Honeywell VISTA-21iP Operating instructions

Honeywell

Honeywell VISTA-21iP Operating instructions

Honeywell Informa User manual

Honeywell

Honeywell Informa User manual

Honeywell Manning GM-JR Manual

Honeywell

Honeywell Manning GM-JR Manual

Honeywell VISTA-21iP Assembly instructions

Honeywell

Honeywell VISTA-21iP Assembly instructions

Honeywell VISTA-128BPTSIA User manual

Honeywell

Honeywell VISTA-128BPTSIA User manual

Honeywell X-618 User manual

Honeywell

Honeywell X-618 User manual

Honeywell L5200 Series Assembly instructions

Honeywell

Honeywell L5200 Series Assembly instructions

Honeywell VISTA-128FBP User manual

Honeywell

Honeywell VISTA-128FBP User manual

Honeywell X-618 Quick start guide

Honeywell

Honeywell X-618 Quick start guide

Honeywell 6272CV User manual

Honeywell

Honeywell 6272CV User manual

Honeywell ADEMCO LYNXR-ISIA Assembly instructions

Honeywell

Honeywell ADEMCO LYNXR-ISIA Assembly instructions

Honeywell INTELLIGUARD 9000 Manual

Honeywell

Honeywell INTELLIGUARD 9000 Manual

Honeywell Lyric SIXSIREN User manual

Honeywell

Honeywell Lyric SIXSIREN User manual

Popular Security System manuals by other brands

Lorex SG15F5584 instruction manual

Lorex

Lorex SG15F5584 instruction manual

DESi Proline Series user manual

DESi

DESi Proline Series user manual

AKO AKO-55624 quick guide

AKO

AKO AKO-55624 quick guide

First Alert FA1340C user manual

First Alert

First Alert FA1340C user manual

Panasonic AW-HE100 Brochure & specs

Panasonic

Panasonic AW-HE100 Brochure & specs

Leitronic AG bebetelEXTRA manual

Leitronic AG

Leitronic AG bebetelEXTRA manual

CADDX Ranger 8980 user manual

CADDX

CADDX Ranger 8980 user manual

Brooks BOWS020W Operation & technical manual

Brooks

Brooks BOWS020W Operation & technical manual

Pulsar 17/TRP40/PAR/SP/GRADE 3 Assembly instructions

Pulsar

Pulsar 17/TRP40/PAR/SP/GRADE 3 Assembly instructions

NAPCO Gemini GEM-X255 operating guide

NAPCO

NAPCO Gemini GEM-X255 operating guide

Symphony FA800KP user guide

Symphony

Symphony FA800KP user guide

Sentrol Arrowhead SC800 Installation & programming manual

Sentrol

Sentrol Arrowhead SC800 Installation & programming manual

Kroger Bandit 3 operating instructions

Kroger

Kroger Bandit 3 operating instructions

SVAT ClearVu Q1204 instruction manual

SVAT

SVAT ClearVu Q1204 instruction manual

Fox Micron MX2 operating instructions

Fox

Fox Micron MX2 operating instructions

Wilo Control DrainAlarm Installation and operating instructions

Wilo

Wilo Control DrainAlarm Installation and operating instructions

Citadel XR1 G3 operating instructions

Citadel

Citadel XR1 G3 operating instructions

Roiscok iDo218 manual

Roiscok

Roiscok iDo218 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.