MANUAL • Subject to alteration! Stand: October 2021
ipf electronic gmbh
│
Rosmarter Allee 14 • 58762 Altena • Germany
│
Tel +49 2351 9365-0 • info@ipf-electronic.com •www.ipf-electronic.com 1
UT309023
Ultrasonic Sensor
Diffuse-reflection sensor
IMeasuring range adjustable via teach-in
IAnalog output
IM12-connector
TECHNICAL DATA
Scanning range
600 … 6000mm
Operating voltage U
B
18 … 30V DC
Analog output
0 … 10V, 4 … 20mA switchable, not reverse polarity
protected
Load resistance (4 … 20mA)
< 400Ω
Load resistance (0 … 10V) > 10kΩ
Switching output (adjustable via IO-Link)
Push-Pull, no/nc switchable
Output current (max. load)
100mA
Short-circuit proof +
Reverse polarity protected
+
Voltage drop
2.0V DC
Switching frequency
2Hz
Current consumption (without load
45mA
Standard measuring plate
200 x 200mm
Resolution
1.0mm
Repeatability
4.0mm
Linearity error
0.5%
Mounting distance (sensor to sensor)
1,400mm
Setting
Teach-In
Carrier frequency
80kHz
Protection class
III
Insulation dielectric strength
500V
Protection class (EN 60529)
IP 67
Material (housing)
Brass nickel plated
Temperature (operation)
-25 … +70°C
Temperature drift
0.2%/K (uncompensated)
Connection
M12-connector 4-pole
Connection accessories
e.g. VK200325
Connection Dimensional drawing
IO-Link interface
4 … 20mA / 0 … 10V switchable
Sound
outlet
MANUAL • Subject to alteration! Stand: October 2021
ipf electronic gmbh
│
Rosmarter Allee 14 • 58762 Altena • Germany
│
Tel +49 2351 9365-0 • info@ipf-electronic.com •www.ipf-electronic.com 2
Approved use
The ultrasonic diffuse-reflection sensor are used as part of a higher-level overall system for the contactless detection of
objects.
Function
The ultrasonic diffuse-reflection sensors work on the principle of time-of-flight measurement. The device transmits a pulse
train, which is then reflected by an object. The device detects the reflected wave and measures the time that has elapsed
between the transmission and reception processes. This time is used to determine the distance between the sensor and
the object. If the results correspond to the specified values, the analog output outputs a value proportional to the distance
and the switching output is set accordingly.
Mounting
The sensor may be mounted in any position. Make sure that it is mounted in a vibration-free and vibration-damping manner.
Also protect the device against mechanical loads such as shocks or impacts.
It is imperative that the transducer surface as well as the area of the detection lobe are kept free. Make sure that there are
no interfering objects between the sensor and the target object inside the lobe. Otherwise, it is possible that the interfering
object will cause false switching. Also avoid positioning two or more ultrasonic sensors opposite each other.
Temperature
The speed of sound in air depends on the temperature. Operation outside the specified ambient temperature is not
allowed. A temperature compensation can be switched on via IO-Link.
When temperature compensation is activated, the sensor requires about 15 minutes of warm-up time after a cold start;
only then are the measured values reproducible.
Transmission angle of the object in diffuse mode
Objects with a smooth surface are reliably scanned up to a tilting
angle of approx. 5° at 600mm and approx. 2° at 6000mm scanning
range. The maximum permissible tilting angle increases for
objects with rough or highly structured (grained) surfaces.
Blind range in touch mode
The range of 0 … 600mm in front of the sensor corresponds to the
ultrasonic typical blind range.
Distance measurements are not possible in the blind range!
The maximum scanning distance 6000mm.
Sound cone
Plate 200 x 200mm
- - - - - - Round bar Ø25mm
MANUAL • Subject to alteration! Stand: October 2021
ipf electronic gmbh
│
Rosmarter Allee 14 • 58762 Altena • Germany
│
Tel +49 2351 9365-0 • info@ipf-electronic.com •www.ipf-electronic.com 3
Cleaning
For cleaning a soft cloth moistened with soapy water is recommended.
Commissioning and setting
The measuring range is taught-in and the analog output is switched over by connecting the black wire (PIN 4) to the
operating voltage (PIN1).
The teach process is aborted after 20 seconds (Time Out function).
Make sure that the object to be detected is always within the scanning range limits (150 … 1500mm). The distance between
value 1 and value 2 must be at least 100mm.
1. Teach-in of the measuring range
1. Position the object at the point where the analog value should be 4mA or 0V.
2. Connect the black wire to the operating voltage for between 0.1 and 2 seconds. The LED is flashing with approx.
1Hz.
3. Position the object at the point where the analog value should be 20mA or 10V.
4. Connect the black wire to the operating voltage for between 0.1 and 2 seconds.
5. The analog output now operates within the defined measuring limits.
2. Changing the output function
1. Connect the black wire to the operating voltage for longer than 6 seconds.
2. The physical quantity of the analog output is changed (instead of current output 4 ... 20mA voltage output 0 ...
10V or vice versa).
Note: Be aware that a considerably larger load resistance is required for operation as a voltage output (see technical
data). It is therefore recommended to disconnect the analog output before each change of the output function to avoid
device damage
3. LED display after each teach process
If the status LED is flashing twice, the teach process was successful and the sensor is working with the new values.
If the status LED is flashing four times, the teach process has been aborted or the time window of 20 seconds has
been exceeded. The sensor operates with maximum measuring range.
On the following page the descriptions are shown again graphically.
The following additional settings can be made using the IO-Link interface:
Measuring ranges < 100mm
Function of the black wire (PIN 4): Teach-in of the analog output
Switching output (push-pull, PNP or NPN)
Synchronization (see "master-slave function" on page 4)
Multiplex (see "master-slave function" on page 4)
If "switching output" is activated, the switching mode, switching function and
hysteresis can also be set
Analog output: 0 ... 20mA, 4 ... 20mA, 0 ... 10V, disable
Teach switching points (the state of the switching output is always output via IO-Link)
Switch-on and switch-off delay for switching output
Restore factory settings
MANUAL • Subject to alteration! Stand: October 2021
ipf electronic gmbh
│
Rosmarter Allee 14 • 58762 Altena • Germany
│
Tel +49 2351 9365-0 • info@ipf-electronic.com •www.ipf-electronic.com 4
1. Teach-in of the measuring range
2. Changing the output function
(4 ... 20mA - 0 ... 10V)
3. LED display after each teach
process
Master-/slave function
With the help of this function, up to 10 sensors of the same type can be operated in parallel.
To do this, configure the devices accordingly via IO-Link. Define one sensor as the master and all
others as slaves. The master must be assigned the highest number in the network.
Then connect the black wires (PIN 4) with each other (see connection diagram).
The following operating modes can be selected:
1. Synchronous operation: The transmission pulse of all sensors occurs simultaneously with
synchronized evaluation. Select this function for monitoring large
areas.
2. Multiplex operation: The transmission pulses of the sensors are time-delayed in a defined
sequence. The devices can thus no longer influence each other,
smaller distances between them are possible.
Note: Resetting to the factory setting is only possible via IO-Link.
SAFETY INSTRUCTIONS:
Before commissioning, please make sure that all safety instructions listed in the product documentation, if applicable,
have been observed!
In case of direct impact on personal safety, the use of these products is prohibited.

Other ipf electronic Accessories manuals

ipf electronic OT0591A4 User manual

ipf electronic

ipf electronic OT0591A4 User manual

ipf electronic UT360321 User manual

ipf electronic

ipf electronic UT360321 User manual

ipf electronic ON430571 User manual

ipf electronic

ipf electronic ON430571 User manual

ipf electronic OTQ80576 User manual

ipf electronic

ipf electronic OTQ80576 User manual

ipf electronic OT059170 User manual

ipf electronic

ipf electronic OT059170 User manual

ipf electronic PY740020 User manual

ipf electronic

ipf electronic PY740020 User manual

ipf electronic UT139570 User manual

ipf electronic

ipf electronic UT139570 User manual

ipf electronic OS15 Series User manual

ipf electronic

ipf electronic OS15 Series User manual

ipf electronic OT05E287 User manual

ipf electronic

ipf electronic OT05E287 User manual

ipf electronic OT330571 User manual

ipf electronic

ipf electronic OT330571 User manual

ipf electronic DW34312 Series User manual

ipf electronic

ipf electronic DW34312 Series User manual

ipf electronic OTR49174 User manual

ipf electronic

ipf electronic OTR49174 User manual

ipf electronic OTR49170 User manual

ipf electronic

ipf electronic OTR49170 User manual

ipf electronic OT059176 User manual

ipf electronic

ipf electronic OT059176 User manual

ipf electronic OR150400 User manual

ipf electronic

ipf electronic OR150400 User manual

ipf electronic PT230020 User manual

ipf electronic

ipf electronic PT230020 User manual

ipf electronic DW34311 Series User manual

ipf electronic

ipf electronic DW34311 Series User manual

ipf electronic IV56E205-S User manual

ipf electronic

ipf electronic IV56E205-S User manual

ipf electronic PRQ80376 User manual

ipf electronic

ipf electronic PRQ80376 User manual

ipf electronic OTR49176 User manual

ipf electronic

ipf electronic OTR49176 User manual

ipf electronic OT450521 User manual

ipf electronic

ipf electronic OT450521 User manual

ipf electronic UT129023 User manual

ipf electronic

ipf electronic UT129023 User manual

ipf electronic UT30C310 User manual

ipf electronic

ipf electronic UT30C310 User manual

ipf electronic UT36002B User manual

ipf electronic

ipf electronic UT36002B User manual

Popular Accessories manuals by other brands

Weber Protect ProV1 2 Gen instruction manual

Weber Protect

Weber Protect ProV1 2 Gen instruction manual

ATC Group Chest Cooler FKG203 Specification sheet

ATC Group

ATC Group Chest Cooler FKG203 Specification sheet

ElectrIQ Eiq-LPB20QC instruction manual

ElectrIQ

ElectrIQ Eiq-LPB20QC instruction manual

Kemo Electronic M173 quick start guide

Kemo Electronic

Kemo Electronic M173 quick start guide

AMX AXU-IR Plus Specifications

AMX

AMX AXU-IR Plus Specifications

Jula 882-049 installation instructions

Jula

Jula 882-049 installation instructions

IFM Electronic OPD100 operating instructions

IFM Electronic

IFM Electronic OPD100 operating instructions

Nittan Sensortec ST-H-AS instruction manual

Nittan

Nittan Sensortec ST-H-AS instruction manual

PLAYNETIC ProtectoNetic user manual

PLAYNETIC

PLAYNETIC ProtectoNetic user manual

Electro-Voice DI-1 Technical specifications

Electro-Voice

Electro-Voice DI-1 Technical specifications

Airspan AirHarmony-4200 DC installation guide

Airspan

Airspan AirHarmony-4200 DC installation guide

Crestron B-G1-WPK installation guide

Crestron

Crestron B-G1-WPK installation guide

Elenco Electronics AK-100/SP-1A Assembly and instruction manual

Elenco Electronics

Elenco Electronics AK-100/SP-1A Assembly and instruction manual

Liebert UPStation S VCR232CR Installation and instruction manual

Liebert

Liebert UPStation S VCR232CR Installation and instruction manual

Huawei BTS3900A Quick installation

Huawei

Huawei BTS3900A Quick installation

Nokia Flexi Multiradio BTS TECHNICAL-OPERATING DOCUMENTATION

Nokia

Nokia Flexi Multiradio BTS TECHNICAL-OPERATING DOCUMENTATION

Honeywell RDWL917AX2000 Installation and operation guide

Honeywell

Honeywell RDWL917AX2000 Installation and operation guide

Pasport PS-2170 instruction manual

Pasport

Pasport PS-2170 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.