JA-151P-WW Wireless PIR motion detector
JA-151P-WW 1 / 2 MMN51207
The JA-151P-WW is a wireless component of the JABLOTRON
100+ system. It serves for the detection of human movement in building
interiors. Its guaranteed detection coverage is 90° horizontally and
detection range is 12 m. This PIR motion detector utilizes a white lens
which provides standard immunity against white light required
by the norm (up to 6000 lux). False alarm immunity is available
in two options. The detector has a pulse reaction and takes one position
in the system. The detector should be installed by a trained technician with
a valid certificate issued by an authorized distributor.
Installation
It’s necessary to take into consideration that there should be no obstacles
in the detector’s view which quickly change temperature (electric heaters,
gas appliances, etc.), which move (e.g. curtains hanging above a radiator,
robotic vacuum cleaners) or the movement of house pets. Despite
the detector being very immune to false alarms, it is not recommended
to install the detector opposite windows or floodlights or in places with over-
intense air circulation (close to ventilators, heat sources, air conditioning
outlets, unsealed doors, etc.). There should be no obstacles in front
of the detector obscuring its view over the guarded space.
Figure 1.: 1 – LED indicators, 2 – PIR lens, 3 – Hole for locking screw,
4 – Cover tab
1. Open the detector cover by pressing the cover tab (4). Avoid
touching the PIR sensor inside (6) – you could damage it
2. Take out the PCB – it is held by a tab in the lower part.
3. Punch through the holes for the screws and the cable in the plastic
base. The recommended installation height is 2.5 m above
the floor.
4. Set the DIP switches (9) according to the requirements, see
the Detector settings.
5. Insert the PCB back and proceed according to the control panel
installation manual. Basic procedure:
a. The control panel must contain the JA-11xR radio module.
b. Go to the F-Link software, select the required position
in the Devices window and launch the Enrollment mode
by clicking on the Enroll option.
c. Insert the batteries (mind the correct polarity). When the second
battery has been inserted into the detector, an enrollment signal
is transmitted to the control panel and the detector is enrolled
to the selected position. The detector can be enrolled
by entering the production code (8).
d. This is followed by a detector stabilization phase indicated with
LED indicator (10) flashing which takes up to three minutes.
6. Close the detector cover. In order to comply with norms, the cover
tab (4) must be secured with the supplied screw.
Figure 2: 5 – Antenna; 6 – PIR sensor; 7 – Tamper contact; 8 – Production
code; 9 – Setting DIP switches; 10 – Red LED indicator;
11 – The JA-191PL external tamper connector; 12 – Battery holder
Note:
−The detector can be removed from the system by deleting it from
its position in the Devices tab.
Detector internal settings
Internal settings can be configured by DIP switch on a PCB inside
the detector (*factory defaults).
Immunity level: DIP switch no. 1 determines a level of false alarm
immunity. The NORM* level (default setting) combines basic immunity
with a rapid reaction. The HIGH level (DIP switch ON) provides
increased immunity but the detector reaction is slower.
External tamper sensor: DIP switch no. 2 can enable (DIP switch
ON) /disable* the external tamper of the JA-191PL jointed bracket.
Detector function modes
The detector can work in two modes. They are indicated by one or two
flashes of the LED light (10) when batteries are inserted.
One flash represents Smartwatch*mode. It’s determined for
the permanent monitoring of movement in the guarded area.
If permanent movement is detected, three reports are sent every 20 s.
The next report is then sent after 2 minutes. If the detector does not
detect any movement for 10 minutes, the mode with three reports every
20 s is used again.
Two flashes represent a One minute interval. The detector enters
standby mode for 1 minute after it has detected movement.
When the standby mode times out, the detector wakes up and is ready
to be triggered again.
To change the mode, press and hold the tamper contact (7)
in the cover, insert the batteries at the same time. Release the tamper
contact 3-5 seconds after the batteries insertion. The detector then
flashes either once or twice to indicate the currently selected mode.
When batteries are replaced the setting doesn’t change.
Detector testing
When you close the detector cover, LED light indicates all movement
for a period of 15 minutes and reports it to the control panel. After this
time the detector switches to the mode which was selected during
the battery insertion.
Detector functions can also be checked via the Diagnostics window
in the F-Link software. You can check the selected mode and immunity
level in Internal settings. This information serves as a preview and
can’t be changed by F-link software.
Battery replacement
The system sends automatic reports when the battery is low.
Remember to switch the system to Service mode before changing
the batteries. It’s necessary to wait for 10 seconds or repeatedly press
the tamper contact (7) in order to release the remaining charge before
you insert new batteries. If you insert batteries with low energy (≤2,5V
detected) the LED light will indicate that by flashing rapidly during
the testing period.
Detection characteristics
The standard lens that is supplied with the detector has a white
colour and covers an area of 90°/12 m. The area is covered
by 3 beams (curtains) – see the following figure. The lens cannot
be replaced by a different type of lens.
Figure 3. This detection characteristic is valid for standard PIR immunity.
Installation accessories
JA-193PL – Detector wall holder. Instead of installing the detector
in a room’s corner, it’s possible to install it on a wall surface using
a JA-193PL aesthetic frame which is distributed in two colours – white
and grey. Using the frame, the detector is partially hidden under
a plaster or plasterboard wall.
JA-191PL – PIR jointed bracket. It is used for special placement,
such as installation on the ceiling or at a tilted angle (higher installation
height). The jointed bracket is a certified detector accessory having its
own tamper contact which is to be connected to the connector inside
the detector (11).
JA-151P-WW Wireless PIR motion detector
JA-151P-WW 2 / 2 MMN51207
Technical specifications
Power 2x AA (LR6) / 1.5 V / 2400 mAh alkaline batteries
Please note: Batteries are not included
Typical battery lifetime approx. 2 years
(the longest lifetime is achieved in smartwatch mode)
Low battery voltage < 2,2 V
Quiescent current consumption 25 μA
Maximum current consumption 50 mA
Communication frequency 868.1 MHz, JABLOTRON protocol
Maximum radio-frequency power (ERP) 13 mW
Communication range approx. 300 m (open area)
Recommended installation height 2.5 m above the floor
Detection angle / detection range 90 °/12 m
Dimensions 62 x 130 x 38 mm
Weight (without batteries) 139 g
Classification Security grade 2 / Environmental class II
(according to EN 50131-1)
Operational environment Indoor general
Operating temperature range -10 °C to +40 °C
Average operating humidity 75 % RH, without condensation
Certification body Trezor Test s.r.o. (no. 3025), Telefication B.V.
Complies with EN 50131-1, EN 50131-2-2, EN 50131-5-3,
EN 50131-6, ETSI EN 300 220-1,-2, EN 50130-4,
EN 55032, EN 62368-1, EN 50581, T 031
Can be operated according to ERC/REC 70-03
Recommended screw 2x ø 3,5 x 40 mm (countersunk head)
JABLOTRON ALARMS a.s. hereby declares that the JA-151P-
WW product
is in a compliance with the relevant Union
harmonisation legislation: Di
rectives No: 2014/53/EU,
2014/35/EU, 2014/30/EU, 2011/65/EU if it is used as intended.
The original of the conformity assessment can be found
at www.jablotron.com - Section Downloads.
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use.

Other jablotron Security Sensor manuals

jablotron JA-155P User manual

jablotron

jablotron JA-155P User manual

jablotron JA-180PB User manual

jablotron

jablotron JA-180PB User manual

jablotron JA-160PC User manual

jablotron

jablotron JA-160PC User manual

jablotron JS-20 User manual

jablotron

jablotron JS-20 User manual

jablotron JA-80IR User manual

jablotron

jablotron JA-80IR User manual

jablotron JA-83M User manual

jablotron

jablotron JA-83M User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

jablotron JK-16 PROFI User manual

jablotron

jablotron JK-16 PROFI User manual

jablotron JA-169P User manual

jablotron

jablotron JA-169P User manual

jablotron JA-180S User manual

jablotron

jablotron JA-180S User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

jablotron JA-111TH User manual

jablotron

jablotron JA-111TH User manual

jablotron JA-60P User manual

jablotron

jablotron JA-60P User manual

jablotron JA-80S User manual

jablotron

jablotron JA-80S User manual

jablotron JA-60V User manual

jablotron

jablotron JA-60V User manual

jablotron JA-181M User manual

jablotron

jablotron JA-181M User manual

jablotron JA-151P-WG User manual

jablotron

jablotron JA-151P-WG User manual

jablotron JB-EXT-TH-R User manual

jablotron

jablotron JB-EXT-TH-R User manual

jablotron JA-152SHM User manual

jablotron

jablotron JA-152SHM User manual

jablotron JA-151P-WW User manual

jablotron

jablotron JA-151P-WW User manual

jablotron JA-120PW User manual

jablotron

jablotron JA-120PW User manual

jablotron JA-83M User manual

jablotron

jablotron JA-83M User manual

jablotron JA-80PB User manual

jablotron

jablotron JA-80PB User manual

jablotron JA-80S User manual

jablotron

jablotron JA-80S User manual

Popular Security Sensor manuals by other brands

Sfere DASv10 User handbook

Sfere

Sfere DASv10 User handbook

Fracarro WL04IR manual

Fracarro

Fracarro WL04IR manual

Inficon D-TEK 3 operating manual

Inficon

Inficon D-TEK 3 operating manual

AVS Electronics ONE PA manual

AVS Electronics

AVS Electronics ONE PA manual

LEGRAND LE03020AB quick start guide

LEGRAND

LEGRAND LE03020AB quick start guide

C-LOGIC 640-MD instruction manual

C-LOGIC

C-LOGIC 640-MD instruction manual

Evikon PluraSens E2670-HFC user manual

Evikon

Evikon PluraSens E2670-HFC user manual

B.E.G. Luxomat PD2-S Mounting instructions

B.E.G.

B.E.G. Luxomat PD2-S Mounting instructions

HomeMatic HMIP-SMO-A-2 Mounting instruction and operating manual

HomeMatic

HomeMatic HMIP-SMO-A-2 Mounting instruction and operating manual

STEINEL HF 3360 manual

STEINEL

STEINEL HF 3360 manual

Safety Technology International STI-6400 Exit Stopper instruction manual

Safety Technology International

Safety Technology International STI-6400 Exit Stopper instruction manual

Mustang Survival MD2010 owner's manual

Mustang Survival

Mustang Survival MD2010 owner's manual

Petzl SPIRIT SL TECHNICAL NOTICE

Petzl

Petzl SPIRIT SL TECHNICAL NOTICE

Elko iNels Air AirWD-101 Series manual

Elko

Elko iNels Air AirWD-101 Series manual

GJD D-TECT Pet Immune GJD370 manual

GJD

GJD D-TECT Pet Immune GJD370 manual

QMI water guardian manual

QMI

QMI water guardian manual

Nationwide Industries The Protector NW308 Installation, adjustment and maintenance instructions

Nationwide Industries

Nationwide Industries The Protector NW308 Installation, adjustment and maintenance instructions

Ultra-safe 96305 User instruction manual

Ultra-safe

Ultra-safe 96305 User instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.