13
The CM-5 makes color measurements simple. Just switch it on and start taking measurements. No need to bother with a computer;
the CM-5 has a full range of advanced functions including specialized indices for a variety of applications and a large color display
that makes results easy to read.
Finally, high accuracy and ease of use in a compact top-port spectrophotometer!
Mini Petri Dish
(optional accessory) enables
measurements of small sample
amounts.
Automatic white•calibration
compatible.
An advanced all-in-one spectrophotometer with innovative
operation to let anyone take measurements easily anytime
Spectrophotometer
1
2
3
Internal calibration curves for measuring standard
chemical/pharmaceutical indices
The CM-5 can measure several of the standard
color indices commonly used in the chemical and
pharmaceutical eld: Gardner, Platinum-Cobalt
Color Scale (Hazen/ APHA), Iodine Color Number,
European Pharmacopoeia and US Pharmacopeia
(equivalent to Japanese Pharmacopoeia color
indices). Calibration curves*1 for these indices are
stored in the CM-5, so measurements of samples
based on these indices can be performed quickly and easily by anyone.
*1 Index calibration curves were measured using 10mm-Wide Cell Measurement Set
CM-A207 and commercially available 10mm-wide cells with 10mm optical path length.
Ø16mm Mini Petri Dish
for small sample amounts (Optional accessory)
The optional Mini Petri Dish enables measurements of costly
powder samples such as rare-earth metals, organic EL materi-
als, pharmaceuticals, etc. to be taken using much less sample
material (approximately 1/20 of amounts required using our
conventional Petri Dish CM-A128). In addition, the automatic
white calibration function also works with the Mini Petri Dish,
so measurements can be taken shortly after switching the in-
strument on without performing calibration manually.
Do many people in your lab use the same
instrument? The CM-5 helps eliminate
that confusion by letting users store their
own settings on their own USB memory
stick, so they can restore the settings they
need by simply reading from the memory
stick instead of going through and redo-
ing settings individually. Afterwards when
they’re nished, they can store measurement and target data on the same
USB key and take it with them for further analysis.
Measurements as simple as 1-2-3!
Just follow the wizard!
Avoid multi-user confusion with USB!
Compact, versatile color instru
ment
Reectance measurements
The measuring port of the CM-5 is on top, so users can just place a solid object on
the port and press the MEAS. button. There’s no need to clamp the sample in a
sample holder, and there’s no worry about the sample shifting position.
And, by using a Petri dish (optional accessory), liquids, pastes, and powders can
also be measured easily.
Samples are just
placed on top, so
even large samples
can be measured.
By using the Ø3mm
target mask (op-
tional accessory),
even small samples
can be measured.
Pastes can also be
measured using a
Petri dish (optional
accessory).
Colorant pellets
can be measured
in raw form using a
Petri dish (optional
accessory).
System Diagram
Standard
accessories
Optional
accessories
Spectrophotometer
CM-5
Target Mask (Ø3 mm)
CM-A195
Petri Dish
Measurement Full Set*
Target Mask (Ø8 mm)
CM-A196
Target Mask (Ø30 mm)
CM-A197
Transmittance Mask
CM-A200
(Ø20 mm)
Dust Cover
CM-A191
CM-S100w
Cell
CM-A98
(10 mm)
Cell
CM-A97
(2 mm)
Cell
CM-A99
(20 mm)
Plastic Cell
CM-A132
(20 mm; 100 pcs.)
Specimen Viewing Mirror
CM-A202
Ground Cable CM-A211
USB Cable (2 m)IF-A19
AC Adapter
Plastic Cell
CM-A131
(10 mm; 100 pcs.)
Plastic Cell
CM-A130
(2 mm; 100 pcs.)
PC
(commercially available)
Data printer
(commercially
available)
CM-A205
Mini Petri Dish
Measurement Full Set* CM-A164
Transmittance
Measurement Set* CM-A206
10 mm-Wide Cell
Measurement Set*
10 mm-wide cell
(commercially available)
CM-A207
Connecting Cable CM-A58
Transmittance measurements
The CM-5’s transmittance chamber is
large and sideless, enabling measure-
ments of even large sample sheets
with thicknesses up to 60mm.
For liquids, optional cells with 3 opti-
cal path lengths for dierent sample
densities are available, and commercial
10mm-wide cells can also be used.
Switch on power.
The CM-5 starts up and automatically per-
forms white/100% calibration* using an inter-
nal white calibration plate behind the shutter.
* Not applicable to liquid transmittance measurements us-
ing cells.
Position sample.
For reectance, the top port makes measuring
samples of various shapes and sizes easy. For
transmittance, sliding open the CM-5 reveals
a large transmittance chamber. Liquids can be
measured using optional cells.
Press MEAS.
The measurement is taken and the results ap-
pear in the display. The large color LCD en-
ables data to be shown not only numerically,
but also on the colorimetric plots and spectral
graphs that normally require a computer to
display.
Actual CM-5
screens!
Colorimetric plot Spectral reectance graph
Screens can be shown in any of 8 languages: English, Japanese, German,
French, Italian, Spanish, Simplied Chinese, and Portuguese.
1
3
2
Even beginners can take measurements
easily without mistakes.
The CM-5’s wizard mode guides users
through each step, helping users to make
settings and take measurements without
having to get out the instruction manual
each time.
Petri Dish Measurement
Full Set
CM-A205
Transmittance
Measurement Set
CM-A206
Mini Petri Dish
Measurement Full Set
CM-A164
10mm-Wide Cell Mea-
surement Set
CM-A207
Petri Dish
Measurement Full Set
CM-A205
Mini Petri Dish
Measurement Full Set
CM-A164
Transmittance
Measurement Set
CM-A206
10 mm-Wide Cell
Measurement Set
CM-A207
White Calibration Plate (with CD-ROM containing calibration
data and data-setting software) CM-A210 〇 ○
Zero Calibration Box CM-A124 ○ ○
Target Mask (for Petri Dish) CM-A203 ○
Petri Dish CM-A128 ○
Calibration Glass (for Petri Dish) CM-A212 ○
Target Mask (for Mini Petri Dish) CM-A158 ○
Mini Petri Dish CM-A157 ○
Calibration Glass (for Mini Petri Dish) CM-A159 ○
Transmittance Zero Calibration Plate CM-A213 ○
Transmittance Specimen Holder CM-A96 ○
Transmittance Specimen Holder Attachment CM-A199 ○
Transmittance Specimen Holder (10mm-wide cells) CM-A198 ○
Transmittance Zero Calibration Plate (10mm-wide cells) CM-A204 ○
Accessory Case CM-A193 ○○○
Spectral absorbance measurements
Spectral absorbance can now be measured and displayed numerically or graphi-
cally, enabling evaluation of spectral absorbance for checking absorbance wave-
lengths, evaluating colorants, calculating K/S, determining components, etc.
* For details, refer to the following table.
9242-4858-10 BGEPK Printed in Japan©2009-2016 KONICA MINOLTA, INC.
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
Certificate No : LRQ 0960094/A
Registration Date : March 3, 1995
For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
•Always connect the instrument to the specified power supply
voltage. Improper connection may cause a fire or electric shock.
SAFETY PRECAUTIONS
•The specifications and appearance shown herein
are subject to change without notice.
•If you have any questions about specifications,
please contact your Konica Minolta representative.
•Konica Minolta, the Konica Minolta logo and
symbol mark, and "Giving Shapes to Ideas" are
registered trademarks or trademarks of KONICA
MINOLTA, INC.
Main specications
Model Spectrophotometer CM-5
Illumination/viewing system Reectance: di:8°, de:8° (diuse illumination: 8° viewing)
SCI (specular component included)/SCE (specular component excluded) switchable
Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 condition c standard.
Transmittance: di:0°, de:0° (diuse illumination: 0° viewing)
Conforms to CIE No. 15, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 condition g standard.
Integrating sphere size Ø152 mm
Detector Dual 40-element silicon photodiode arrays
Spectral separation device Planar diraction grating
Wavelength range 360 nm to 740 nm
Wavelength pitch 10 nm
Half bandwidth Approx. 10 nm
Measurement range 0 to 175 % (Reectance or transmittance); Output/display resolution: 0.01%
Light source Pulsed xenon lamp
Measurement time Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s
Measurement/Illumination
area
Reectance: Changeable by changing mask and settings.
LAV: Ø30 mm/Ø36 mm; MAV (optional): Ø8 mm/Ø11 mm; SAV (optional): Ø3 mm/Ø6 mm
Transmittance: Approx. Ø20 mm/ Ø26 mm
Repeatability Spectral reectance: Standard deviation within 0.1% (400 nm to 740 nm)
Chromaticity value: Standard deviation within ΔE*ab 0.04
( When a white calibration plate is measured 30 times at 10-second intervals after white calibration)
Inter-instrument agreement Within ΔE*ab 0.15 (Typical) (LAV/SCI)
(Based on 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard conditions)
Transmittance chamber No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm
Sample holders (optional) for holding sheet samples or containers of liquid samples can be installed/removed
Display 5.7-inch TFT color LCD
Display languages English, Japanese, German, French, Italian, Spanish, Simplied Chinese, Portuguese
White/100% calibration Automatic white (reectance)/100% (transmittance) calibration using internal white calibration plate
(Not applicable to 100% calibration when using cells for transmittance measurements of liquids.)
Interface USB 1.1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer)
Observer 2° or 10° Standard Observer
Illuminant A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation with two light sources possible)
Displayed data Spectral values/graph (reectance, transmittance, absorbance) , colorimetric values/graph, color-dierence values/graph,
pass/fail judgment, pseudo color, color assessment
Colorimetric data L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, and color dierences in these spaces; Munsell
Indexes Reectance: MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925);
ISO Brightness; B (ASTM E 313-73)
Transmittance: Gardner; Iodine Color Number; Platinum-Cobalt Color Scale (Hazen/ APHA); European Pharmacopoeia; US Pharmacopeia
User index User-dened index (Optional Data Management Software SpectraMagic™ NX required for setting user index.)
Color-dierence equation ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l: c)
Pass/Fail judgment Tolerances can be set to colorimetric values (except Munsell), color-dierence values, or reectance index values
Data memory Measurement data: 4,000 measurements; Target color data: 1,000 measurements
USB memory stick* storage Storage of measurement data and target color data. Storage/reading of measurement condition settings
Power AC 100 to 240 V, 50/60 Hz (using exclusive AC Adapter)
Size (W × H × D) Slide cover closed: 385 × 192 × 261mm
Slide cover open: 475 × 192 × 261 mm
Weight Approx. 5.8 kg
Operation temperature/
humidity range
13 to 33°C, relative humidity 80 % or less (at 33°C) with no condensation
Storage temperature/
humidity range
0 to 40°C, relative humidity 80 % or less (at 35°C) with no condensation
* Security-enabled USB memory sticks cannot be used.

Other manuals for cm-5

2

Other Konica Minolta Measuring Instrument manuals

Konica Minolta REGIUS SIGMA2 User manual

Konica Minolta

Konica Minolta REGIUS SIGMA2 User manual

Konica Minolta REGIUS 110 HQ User manual

Konica Minolta

Konica Minolta REGIUS 110 HQ User manual

Konica Minolta CS-2000 User manual

Konica Minolta

Konica Minolta CS-2000 User manual

Konica Minolta VIVID 9i User manual

Konica Minolta

Konica Minolta VIVID 9i User manual

Konica Minolta CR-10 Plus User manual

Konica Minolta

Konica Minolta CR-10 Plus User manual

Konica Minolta Vivid 910 User manual

Konica Minolta

Konica Minolta Vivid 910 User manual

Konica Minolta REGIUS 110 User manual

Konica Minolta

Konica Minolta REGIUS 110 User manual

Konica Minolta CA-210 User manual

Konica Minolta

Konica Minolta CA-210 User manual

Konica Minolta CM-26dG Technical specifications

Konica Minolta

Konica Minolta CM-26dG Technical specifications

Konica Minolta CA-410 Series User manual

Konica Minolta

Konica Minolta CA-410 Series User manual

Konica Minolta CM-3630A User manual

Konica Minolta

Konica Minolta CM-3630A User manual

Konica Minolta CECF-9 User manual

Konica Minolta

Konica Minolta CECF-9 User manual

Konica Minolta JM-103 User manual

Konica Minolta

Konica Minolta JM-103 User manual

Konica Minolta REGIUS 190 User manual

Konica Minolta

Konica Minolta REGIUS 190 User manual

Konica Minolta CHROMA METER User manual

Konica Minolta

Konica Minolta CHROMA METER User manual

Konica Minolta CM-25cG User manual

Konica Minolta

Konica Minolta CM-25cG User manual

Konica Minolta CM-3630 User manual

Konica Minolta

Konica Minolta CM-3630 User manual

Konica Minolta RANGE7 User manual

Konica Minolta

Konica Minolta RANGE7 User manual

Konica Minolta CS-2000A - AUTRE User manual

Konica Minolta

Konica Minolta CS-2000A - AUTRE User manual

Konica Minolta CS-2000 User manual

Konica Minolta

Konica Minolta CS-2000 User manual

Konica Minolta CM-700d User manual

Konica Minolta

Konica Minolta CM-700d User manual

Konica Minolta CA-100PLUS User manual

Konica Minolta

Konica Minolta CA-100PLUS User manual

Konica Minolta CM-36dGV User manual

Konica Minolta

Konica Minolta CM-36dGV User manual

Konica Minolta MULTI GLOSS 268 User manual

Konica Minolta

Konica Minolta MULTI GLOSS 268 User manual

Popular Measuring Instrument manuals by other brands

Minolta AUTOMETER VF - PART 3 manual

Minolta

Minolta AUTOMETER VF - PART 3 manual

Ericsson DT-620 manual

Ericsson

Ericsson DT-620 manual

Unipulse F370 Operation manual

Unipulse

Unipulse F370 Operation manual

Munro L60iF instruction manual

Munro

Munro L60iF instruction manual

WIKA RVM/U-L-1 operating instructions

WIKA

WIKA RVM/U-L-1 operating instructions

Keysight x series Installation note

Keysight

Keysight x series Installation note

Rice Lake Non-NTEP SENDit Kit installation manual

Rice Lake

Rice Lake Non-NTEP SENDit Kit installation manual

Ludlum Measurements 3014 manual

Ludlum Measurements

Ludlum Measurements 3014 manual

Hanna Instruments HI709 instruction manual

Hanna Instruments

Hanna Instruments HI709 instruction manual

Bender ISOMETER iso685W-S-B manual

Bender

Bender ISOMETER iso685W-S-B manual

Aranet PRO user guide

Aranet

Aranet PRO user guide

Philips PM 6303 Service manual

Philips

Philips PM 6303 Service manual

Memotec mychron 3 user manual

Memotec

Memotec mychron 3 user manual

Baumer N 208 operating instructions

Baumer

Baumer N 208 operating instructions

EIT UV Power Puck II user guide

EIT

EIT UV Power Puck II user guide

Taylor Hobson Surtronic Duo manual

Taylor Hobson

Taylor Hobson Surtronic Duo manual

HT SOLAR-02 user manual

HT

HT SOLAR-02 user manual

AEMC 5070 user manual

AEMC

AEMC 5070 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.