PRODUCT SPECIFICATIONS
Power Input rating 208/240Vac, 20A Max., 60Hz
Input Plug type NEMA 6-30P
Output 208/240Vac, 20A Max, 60Hz 4.8kW Max.
Charging Interface SAE J1772TM plug, 12, 18, 25 Ft cable
Auto-reclosure No delay in restarting after power failure
Electrical Protection Over Current, Under Voltage, Over Voltage, Residual
Current, Surge Protection, Short Circuit, Over
Temperature, Ground Fault
User Interface &
Control Status Indicators AC Present, Charging, Fault
Environmental Operating Temperature -40 ° to +122 °
Storage Temperature -40 ° to +176 °
Humidity < 90% relative humidity, non-condensing
Altitude Up to 6000 ft
Mechanical Ingress Protection Type 6 (CCID)
Cooling Natural cooling
Dimension (W x H x D) /
Weight 10 x 3.2 x 1.8 inches, excluding plug and cable / 2.2 lb,
excluding plug and cable
Mounting Bracket, Meets UL requirements - removable without any
tools
Regulation Certificate / Compliance UL/cUL, UL2594, UL2231, UL1998, UL991, FCC Part 15,
SAE J1772TM
7
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
IC STATEMENT
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
J1772 is a trademark of SAE International.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only) www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of
its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the
purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit
www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal
of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment,
overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in
accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability
and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of
any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton
is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to,
or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The
remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing
of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada
H9R 1E9 or by telephone at 1 800 405-5320.