TROUBLESHOOTING
Call our Customer Service Hotline at 1-877-338-7473. PLEASE HAVE THE MODEL NUMBER AND
SERIAL NUMBER AVAILABLE WHEN YOU CALL. These can be found on the label on the back of the
Portable Charger.
If your call is made after business hours or on weekends, please leave your name, telephone number,
the Portable Charger serial number, and a brief description of the problem. A Technical Service
Representative will call back at the earliest opportunity.
As an accessory to your Portable Charger, Leviton offers an Evr-GreenTM GFCI.
For faster charging rates, Leviton also offers Level 2 Home Charging Stations with plug-in and hard-wired
solutions. For information, or to learn about other Evr-GreenTM products, contact Customer Service, or visit
www.leviton.com/evrgreen.
Many questions and answers can be found in our knowledge base community.
Just go to leviton.com and click on the Knowledgebase link, or go directly to
http://communities.leviton.com/community/knowledgebaseforums/evr-green.
CUSTOMER SUPPORT
LIMITED 3 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for three years from the purchase date. Leviton’s only obligation is to correct such defects by repair
or replacement, at its option, if within such three year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Mfg. Co., Inc. 201 North Service Road, Melville, N.Y. 11747. This warranty excludes and there is disclaimed liability for labor for removal of this product
or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of
any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to three years. Leviton is not liable for incidental, indirect,
special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For more information call 1-877-338-7473 or visit www.leviton.com/evrgreen DI-000-EVC11-00A-X4© 2011 Leviton Mfg. Co., Inc.
FCC INFORMATION
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received
including interference that may cause undesired operation.
CAUTION: Any changes or modifications not expressly approved by Leviton will void the user’s authority
to operate this equipment.
CHARGING YOUR VEHICLE
2. Connect the Portable Charger to the Vehicle:
NOTE: The vehicle must be parked close enough to the Portable Charger to allow the Charge
Connector to connect to the vehicle charge port without putting any stress on the Charge Connector
Cord. Position the Charge Connector Cord so that it will not be stepped on, tripped over or otherwise
subjected to damage or stress.
Depress the Charge Connector Release Button and remove the Charge Connector from the dock.
Release the cord straps to unwrap the Charge Connector Cord from the Portable Charger.
Plug the Charge Connector into the charge port on the vehicle (see vehicle owner’s manual for
location of charge port). Ensure that the Charge Connector is fully engaged. Once the Charge
Connector is engaged, a second self-test will initiate, where the Fault LED will illuminate momentarily.
If no fault is detected and a proper connection is made between the vehicle and the Portable Charger,
the Charging LED will illuminate.
NOTE: The Charge Connector Release Button has to be fully released in order for the charging to
start. The Charge Connector cannot be disengaged from the vehicle charge port without depressing
the Charge Connector Release Button. Pressing the Charge Connector Release Button stops the
charge to the vehicle.
3. Charge Vehicle:
At this point, charging will begin automatically (assuming the battery is not fully charged). Verify that
the Power LED and Charging LED are illuminated, and the Fault LED is off.
NOTE: If the Charging LED does not illuminate after the self-test completes and the Charge
Connector is plugged in, remove the Charge Connector and try plugging it in again.
NOTE: Disengaging the Charge Connector from the vehicle charge port while charging will
automatically stop the charging process. Reinserting the Charge Connector into the vehicle charge
port will automatically restart charging after a self-test.
The Portable Charger begins charging at 7 Amps (.84kW). To increase the charge rate to 12 Amps
(1.4kW), press the 12 Amp button. The 12 AMP LED will illuminate to indicate a 12 Amp (1.4kW)
charge rate has been selected.
NOTE: Charging at 12 Amps is recommended when the Portable Charger is plugged into a dedicated
circuit. If the amperage of the outlet being used is insufficient, it can cause a circuit breaker to trip and
stop the charging process. In this circumstance, reset circuit breaker and charge at 7 Amps, or use
another outlet.
4. End Charge:
Once the vehicle has been fully charged, the charging process will automatically stop. Verify that the
Power LED is illuminated, and that the Charging and Fault LEDs are off. The total charge time will
vary based on vehicle, initial charge state of battery, and other variables. Consult your vehicle owner's
manual for specific charge rates. If the vehicle is charging longer than the amount of time specified
in the vehicle’s manual, disconnect the Portable Charger from the vehicle and contact the vehicle
manufacturer.
To interrupt the charging cycle, simply unplug the Charge Connector from the vehicle charge port.
The Charging LED will turn off to alert the user that the charging process has ceased. Reinserting
the Charge Connector into the vehicle charge port will automatically restart charging at 7 Amps
(after a self-test).
5. Disconnect Portable Charger:
CAUTION: Once the vehicle is fully charged, the Charge Connector must be disconnected from the
vehicle charge port before the vehicle can be moved. Simply depress the Charge Connector Release
Button on the Charge Connector and unplug it from the vehicle charge port.
Unplug the AC Supply Plug from the wall outlet. Carefully loop the Charge Connector Cord around the
Portable Charger and insert the Charge Connector into the dock on the Portable Charger. Secure the
Charge Connector Cord in place by re-attaching the cord straps on either side of the Portable Charger.
Store the Portable Charger appropriately.
POWER
FAULT
CHARGING
12 AMP
Power LED is ON
Charging LED is OFF
Fault LED is OFF
12A LED off in .84kW mode;
Illuminated if in 1.4kW mode
Power LED is ON
Charging LED is ON
Fault LED is OFF
12A LED off in .84kW mode;
Illuminated if in 1.4kW mode
No power;
no LED indicators lit
Check that Portable Charger is plugged into receptacle.
Check that circuit breaker(s) is turned on. If LEDs still not lit, Call Customer Support Hotline.
Charging LED not lit
Check that Charge Connector is fully engaged. The Release Button should be fully released.
Check that vehicle is not fully charged.
Self diagnostic test failed. Unplug Charge Connector and reconnect.
If LED still not lit, Call Customer Support Hotline.
Fault LED flashing
Wait to ensure self-test is complete. If a fault is detected, the Fault LED will continue to flash,
and the vehicle will not charge. The Portable Charger will go into an Auto-Restart every 15
minutes. If no fault is detected after the Auto-Restart, the Fault LED will turn off, the
Charging LED will illuminate, and charging will commence. If the fault is still detected after 3
attempts, the Fault LED will illuminate solid Red. Call Customer Support Hotline.
Fault LED illuminated
solid Red
The Portable Charger has been unable to detect a safety ground, or has failed 3 consecutive
self-tests. Disconnect the Portable Charger from the power source, and begin again from step 1.
If the fault continues, call Customer Support Hotline.
PROBLEM
ACTION
TROUBLESHOOTING
CLEANING
The Portable Charger does not require any maintenance other than occasional cleaning.
NOTE: Always unplug the Portable Charger before cleaning.
Use a soft, lightly moistened cloth with a mild detergent solution. DO NOT use any type of abrasive pad,
scouring powder, or flammable solvents such as alcohol.
TECHNICAL SPECIFICATIONS
Amperage
Voltage
Configuration
Enclosure
Operating Temperature
Power
Charging Connector
Storage Temperature
Enclosure
Charge Connector Cord
7A/12A
120V
NEMA 5-15P Plug
Valox iQ
TM
PBT
-35°C to 50°C
0.8kW (7A@120V)/1.4kW (12A@120V)
SAE J1772
TM
(on 18' cable)
-50°C to 80°C
NEMA Type 4
UL Type EV
Electrical Input
Electrical Output
Material Specifications
Environmental Specifications
Valox iQ is a trademark of Sabic Innovative Plastics and has
a 50-85% lower carbon footprint during manufacturing than
using traditional thermoplastics
Standards & Certifications
UL 2251 Standard for Plugs, Receptacles and
Couplers for Electric Vehicles
UL 2231 Standard for Personnel Protection Systems
for Electric Vehicle (EV) Supply Circuits
UL 991 Standard for Tests for Safety-Related
Controls Employing Solid-State Devices
UL 1998 Standard for Software in Programmable
Components
UL 2594 Outline of Investigation for Electric Vehicle
Supply Equipment
UL 62 Standard for Flexible Cords and Cables
NEC Article 625
Electric Vehicle Charging System Equipment
SAE J1772
TM
Electric Vehicle Conductive Charge Coupler
Standard
J1772 is a trademark of SAE International
POWER
FAULT
CHARGING
12 AMP