2.1EN-38021-D09Page 6 of 34
User Manual
InstallationandOperatingInstructions
Subject to modificaitons
Form 403013
Operation/Maintenance
Lincoln Quicklub centralized lubrication systems
must be operated only with installed pressure relief valve.
must be operated with attached or connected SSV meter-
ing device make Lincoln GmbH.
must be refilled in regular intervals with clean and recom-
mended 1) lubricant without air entrapments.
1) see recommendationofthe user or themanufacturer of the
vehicle
operate automatically. However, a regular check (approx.
every 2 days) should be made to ensure that lubricant is
emerging from all lubrication points.
Operation with bayonet plug
Protective measures to be applied for appropriate operation
with bayonet plugs:
"Functional extra-low voltage with safe isolation" /
"Protective Extra-Low Voltage" (PELV)
Standards:
DIN EN 60204 Teil1: 2007-07 / IEC 204-1 /
DIN VDE 0100 Teil 410: 2007-06 / IEC 364-4-41
Safety Instructions, continuation
Installation
Any safety equipment already fitted to the vehicle:
- should not be modified or made ineffective;
- should only be removed for the purpose of fitting the
system;
- must be reinstalled after fitting the system.
Keep Quicklub centralized lubrication systems away from
sources of heat. Adhere to the operating temperature.
Use only original Lincoln spareparts (see Parts Catalog) or
parts approved by Lincoln.
Adhere to:
- the installation instructions of the vehicle manufacturer
as regards all drilling and welding procedures.
- the specified minimum distances between the boreholes
and the upper/lower rim of the frame or between two
boreholes.
4273a 00
ATTENTION!
Consider residual ripple of max.
±
5 %to
connect pumps with direct current version
(in relation to the operating voltage acc. to
DIN 41755).
Repair
Repairs should only be performed by authorized personnel
who are familiar with the repair instructions.
Disposal
Dispose of used or contaminated lubricants as well as of parts
that were in touch with lubricant according to the legal regula-
tions pertaining to environmental protection. Make sure to
observe the safety data sheets of the lubricants used.
ADR
1. The ADR Quicklub central lubrication pump complies with
the design regulations of annex B of the ADR1) and with
the GGVS 2).
1) ADR =actgoverningthe road haulage of hazardous materials
valid for Europe.
2) GGVS - Regulation on carriage of dangerous goods by road
(valid for the Federal Republic of Germany)
2. Moreover, the pump and its electrical equipment comply
with the regulations of annex B.2 (ADR / GGVS regula-
tions for electrical equipment) according to Rn 220000 in
conjunction with the transport units mentioned in Rn
10251.
3. The ADR central lubrication pump is in conformity with the
protection class IP6K9K.
4. Install the ADR Quicklub centralized lubrication pump, the
metering devices, lines and tube fittings as well as the
electrical connection parts in accordance with the Instal-
lation Instructions. Use only original Lincoln parts.
5. After completion of the proper installation and commis-
sioning, the installation of the system must be certi-
fied by means of a stamp and signature of the spe-
cialized workshop or expert. For this purpose, use the
following form.
6. If the pump and the installation do not comply with the
construction regulations of ADR and GGVS, the type ap-
proval is no longer valid.
7. The Operating Instructions along with the certificate duly
filled in must be added to the vehicle papers. It is to be
submitted at the inspection in accordance with § 6, clause
4 GGVS.