manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Security System
  8. •
  9. M-system KSE-1 User manual

M-system KSE-1 User manual

Other M-system Security System manuals

M-system ANR User manual

M-system

M-system ANR User manual

M-system AS4T User manual

M-system

M-system AS4T User manual

M-system AYDV User manual

M-system

M-system AYDV User manual

M-system KSE-x2 User manual

M-system

M-system KSE-x2 User manual

M-system KS2V3 User manual

M-system

M-system KS2V3 User manual

M-system 48NDVD User manual

M-system

M-system 48NDVD User manual

M-system AS4CT User manual

M-system

M-system AS4CT User manual

M-system 48NDVA User manual

M-system

M-system 48NDVA User manual

M-system KSL2 User manual

M-system

M-system KSL2 User manual

M-system KS2TR2 User manual

M-system

M-system KS2TR2 User manual

M-system M1EAXV-1 User manual

M-system

M-system M1EAXV-1 User manual

M-system 48NAT User manual

M-system

M-system 48NAT User manual

M-system ASD1 User manual

M-system

M-system ASD1 User manual

M-system M1EAXV-2 User manual

M-system

M-system M1EAXV-2 User manual

M-system ASWL2 User manual

M-system

M-system ASWL2 User manual

M-system AS4CT User manual

M-system

M-system AS4CT User manual

M-system KS2V2 User manual

M-system

M-system KS2V2 User manual

M-system AS4LC User manual

M-system

M-system AS4LC User manual

M-system AS User manual

M-system

M-system AS User manual

M-system KSL-x5 User manual

M-system

M-system KSL-x5 User manual

M-system M8SED1 User manual

M-system

M-system M8SED1 User manual

M-system M6DXAR User manual

M-system

M-system M6DXAR User manual

M-system M7EASDY User manual

M-system

M-system M7EASDY User manual

M-system R3-AV8 User manual

M-system

M-system R3-AV8 User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

KSE-
❑
1
P. 1 / 3 EM-3609-A Rev.1
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
Signal conditioner (body + base socket + input resistor)
(1)
Input resistor is provided only with current input type.
■ MODEL NO.
Check that model No. described on specification label is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, installation, connection and basic mainte-
nance procedures.
COMPONENT IDENTIFICATION
■ FRONT PANEL CONFIGURATION
INSTRUCTION MANUAL
MODEL KSE-❑1
DC ALARM
(dial adjustment; single trip)
Input Resistor
INSTALLATION
Detach the yellow clamps lo-
cated at the top and bottom of
theunitforseparatingthebody
from the base socket.
■ DIN RAIL MOUNTING
Set the base socket so that its
DIN rail adaptor is at the bot-
tom. Position the upper hook
at the rear side of base socket
on the DIN rail and push in the
lower. When removing the
socket, push down the DIN rail
adaptorutilizingascrewdriver
(–) and pull.
■ WALL MOUNTING
Refer to the drawings in the following page.
TERMINAL CONNECTIONS
Connect the unit as in the diagram in the following page or
refer to the connection diagram label on top of the unit.
When an input resistor is provided with the module, attach
it together with input wiring to the input screw terminals.
100
50
%
0
KSE
Model
K
-UNIT
Connection Diagram
Label Base Socket
Body
Specification
Label
Hi Monitor LED
Hi Setpoint Adj. Dial
100
50
%
0
Clamp
(top & bottom)
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
Shape and size of the base socket
are slightly different with various
socket types.
KSE-
❑
1
P. 2 / 3 EM-3609-A Rev.1
+
–
*
INPUT 3
R4
*Input shunt resistor attached for current input.
U
VPOWER
7
8
1
2
5
6
HI
LO
COM
COM
HI OUTPUT
DRAWINGS mm (inch)
■DIMENSIONS
3456
2187
80 (3.15)
50 (1.97)
[3.3 (.13)]
80 (3.15)
20
(.79)
35.4 (1.39)
40 (1.57)
50 (1.97)
7.8 (.31)
CLAMP
(top & bottom)
DIN RAIL
35mm wide
2–4.5 (.18) dia.
MTG HOLE
15 (.59) deep
8–M3.5
SCREW
•When mounting, no extra space is needed between units.
116 (4.57)
136 (5.35)
■CONNECTION DIAGRAM ■TERMINAL ASSIGNMENT
56
2187
34
12 (.47)
INPUT RESISTOR
(model: REM)
Input shunt resistor attached
for current input.
KSE-
❑
1
P. 3 / 3 EM-3609-A Rev.1
CHECKING
1) Terminal wiring: Check that all cables are correctly
connected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal 7
–8 with a multimeter.
3) Input: Check that the input signal is within 0 –100% of
the full-scale.
4) Output load: Check that the output load is 380V AC/
100VA or 125V DC/30W at the maximum (≤0.5A for CE
marking). Foruse with inductive load,external protection
is recommended.
ALARM RELAY OPERATIONS
•Trip operation in power failure: terminals 5 –6 turn ON.
ADJUSTMENT PROCEDURE
■ HOW TO ADJUST ALARM SETPOINTS
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) Turn the front dial to an approximate position for the
setpoint.
2) Vary simulated input signal around the setpoint and
confirm relay operation and set.
POINTS OF CAUTION
■ CONFORMITY WITH CE/LVD DIRECTIVE
•This equipment is suitable for use in Pollution Degree 2
environment and in Installation Category II, with the maxi-
mum operating voltage 300V.
A basic insulation is maintained. Prior to installation, check
that the insulation class of this unit satisfies the system
requirements.
•The equipment must be mounted inside a panel.
•The equipment must be installed such that appropriate
clearance and creepage distances are maintained to conform
to CE requirements. Failure to observe these requirements
may invalidate the CE conformance.
■ POWER INPUT RATINGS
•Power input ratings are specified by the model number
suffix code. Check the power input voltage for the unit on the
specification label.
AC power: Suffix code K3 : 90 –132V
Suffix code L3 : 180 –264V
47 –66 Hz, approx. 3VA
■ GENERAL
•Before you remove the unit from its base socket or mount it,
turn off the power supply and input signal for safety.
■ ENVIRONMENT
•Indoor use
•When heavy dust or metal particles are present in the air,
install the unit inside proper housing and ventilate it.
•Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
•Environmental temperature must be within -5 to +55°C (23
to131°F)with relative humiditywithin 30 to90% RH inorder
to ensure adequate life span and operation.
■ WIRING
•Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
•Donot bindthese cables together with thosein whichnoises
are present. Do not install them in the same duct.
■ AND ....
•The unit is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data sheet.
MAINTENANCE
Regular calibration procedure is explained below:
■ CALIBRATION
Warm up the unit for at least 10 minutes.
Increasethe input signalfroma value lowerthan the setpoint
and check that the trip point remains within the accuracy
described in the data sheet.
When the trip points are out of tolerance, contact M-System’s
Sales Office or local representatives.
050100
Input
(%) ▲
Setpoint
Hi Output
(5–6)ON (1–2)ON
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
productwasoriginallypurchasedifsuchproducthasbeenusedundernormaloperatingconditionsandproperlymaintained,M-System'ssoleliability,andpurchaser'sexclusiveremedies,
under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To
submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]