manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Security System
  8. •
  9. M-system KSL-x5 User manual

M-system KSL-x5 User manual

BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
DC alarm (body + base socket + input resistor) ................(1)
Input resistor is provided only with current input type.
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
AC power: Rating ±10%, 50/60 ±2 Hz, approx. 2VA
DC power: Rating ±10%, approx. 2W
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body Base Socket
x10
HI SET.
(%)
X1
x10
LO SET.
(%)
X1
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
KSL
Model
K
•UNIT
Specifications
Input Resistor
■FRONT PANEL CONFIGURATION
Lo LED
Lo Setpoint Rotary Switch (×1%)
Lo Setpoint Rotary Switch (×10%)
Hi Setpoint Rotary Switch (×1%)
Hi Setpoint Rotary Switch (×10%)
Hi LED
HI SET
[%]
x1
x10
LO SET
[%]
x1
x10
• Explanations
Hi and Lo setpoint rotary switches are used to set the alarm
setpoints.
The Hi and Lo LED, turn on when the coil for each relay is
energized.
• Examples
For setting the relay to trip above 80% of the full-scale input
signal, set the Hi rotary switch (×10) to “8”, while the switch
(×1) to “0”.
INSTALLATION
Detach the yellow clamps located at the top and bottom of
the unit for separate the body from the base socket.
Clamp
(top & bottom)
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
Shape and size of the base socket
are slightly different with various
socket types.
■DIN RAIL MOUNTING
Set the base socket so that its
DIN rail adaptor is at the bot-
tom. Hang the upper hook at
the rear side of base socket on
the DIN rail and push in the
lower. When removing the
socket, push down the DIN
rail adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DI-
MENSIONS.”
DC ALARM
(rotary switch adjustment) MODEL KSL-x5
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3613-B Rev.5 P. 1 / 3
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the front of the unit.
When an input resistor is provided with the module, attach it together with input wiring to the input screw terminals.
■EXTERNAL DIMENSIONS unit: mm (inch)
80 (3.15)
50 (1.97) 103 (4.06)
132 (5.20)
20
(.79)
• When mounting, no extra space is needed between units.
5678
21
1110
[3.3 (.13)]
80 (3.15)
40 (1.57)
50 (1.97)
7.8 (.31)
CLAMP
(top & bottom)
DIN RAIL
35mm wide
2
–
4.5 (.18) dia.
MTG HOLE
25 (.98) deep
11
–
M3.5
SCREW
39
4
■CONNECTION DIAGRAM
+
–
INPUT
5
6
R
V(–)
7
8
POWER
*Input shunt resistor attached for current input.
*
U(+)
2
1
11
10
9
3
N.C.
HI
OUTPUT
N.O.
COM
N.C.
LO
OUTPUT
N.O.
COM
■TERMINAL ASSIGNMENTS unit: mm (inch)
78
21
1110
39
4
12 (.47)
INPUT RESISTOR
(model: REM)
56
Input shunt resistor attached
for current input.
KSL-x5
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3613-B Rev.5 P. 2 / 3
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Alarm operations: Check the alarm operations referring
to the figure below.
5) Output load: Check that the output load is 380V
AC/120VA or 125V DC/30W at the maximum . For maxi-
mum relay life with inductive load, external protection is
recommended.
Alarm Trip Operation Terminal No. in parentheses
050 100▲
Input
(%)
Lo Setpoint
▲
Hi Setpoint
Hi Output
(9–10)ON
Lo Output
(1–3)ON
(1–2)ON
(9–11)ON
Trip Operation in Power Failure
: Terminals 1 – 3, 9 – 11 turn ON.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes.
• Hi Setpoint
Increase the input signal from a value lower than the set-
point and check that the trip point remains within the
accuracy described in the data sheet.
• Lo Setpoint
Decrease the input signal from a value higher than the
setpoint and check that the trip point remains within the
accuracy described in the data sheet.
When the setpoints are shifted, please contact M-System’s
Sales Office or representatives.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
KSL-x5
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3613-B Rev.5 P. 3 / 3

Other M-system Security System manuals

M-system M2AS User manual

M-system

M-system M2AS User manual

M-system AS4T User manual

M-system

M-system AS4T User manual

M-system 48NDM User manual

M-system

M-system 48NDM User manual

M-system M1EAXV-1 User manual

M-system

M-system M1EAXV-1 User manual

M-system AS User manual

M-system

M-system AS User manual

M-system 10AS User manual

M-system

M-system 10AS User manual

M-system Mini-M M2SED User manual

M-system

M-system Mini-M M2SED User manual

M-system AYDV User manual

M-system

M-system AYDV User manual

M-system ASD1 User manual

M-system

M-system ASD1 User manual

M-system AS4R User manual

M-system

M-system AS4R User manual

M-system AS4CT User manual

M-system

M-system AS4CT User manual

M-system M8SED1 User manual

M-system

M-system M8SED1 User manual

M-system AS4T User manual

M-system

M-system AS4T User manual

M-system KSE-1 User manual

M-system

M-system KSE-1 User manual

M-system 48NDT User manual

M-system

M-system 48NDT User manual

M-system M8SED User manual

M-system

M-system M8SED User manual

M-system KS2V2 User manual

M-system

M-system KS2V2 User manual

M-system 48NAM User manual

M-system

M-system 48NAM User manual

M-system AS4CT User manual

M-system

M-system AS4CT User manual

M-system AS4LC User manual

M-system

M-system AS4LC User manual

M-system AS4V User manual

M-system

M-system AS4V User manual

M-system AYDV User manual

M-system

M-system AYDV User manual

M-system 48NAT User manual

M-system

M-system 48NAT User manual

M-system R3-AV8 User manual

M-system

M-system R3-AV8 User manual

Popular Security System manuals by other brands

ELBRO ST-SK1 installation manual

ELBRO

ELBRO ST-SK1 installation manual

SILENT KNIGHT INTELLIKNIGHT 5820XL Basic operating instructions

SILENT KNIGHT

SILENT KNIGHT INTELLIKNIGHT 5820XL Basic operating instructions

Federal Signal Corporation 400 Series installation instructions

Federal Signal Corporation

Federal Signal Corporation 400 Series installation instructions

CQR PADP2 Series user manual

CQR

CQR PADP2 Series user manual

DITEC SOF instruction manual

DITEC

DITEC SOF instruction manual

Stecom TOPLINE operating instructions

Stecom

Stecom TOPLINE operating instructions

Bticino HC4608 quick start guide

Bticino

Bticino HC4608 quick start guide

Yongse FK-007X manual

Yongse

Yongse FK-007X manual

Honeywell ADEMCO CE3 Code Encryptor 3 Installation and setup guide

Honeywell

Honeywell ADEMCO CE3 Code Encryptor 3 Installation and setup guide

Syris SYRDF5 Install and operation instructions

Syris

Syris SYRDF5 Install and operation instructions

Thermo Scientific Smart Siren user guide

Thermo Scientific

Thermo Scientific Smart Siren user guide

SecurityMan SECURITYBARPD user manual

SecurityMan

SecurityMan SECURITYBARPD user manual

M-LOCKS Bravo BR5010 Technical manual

M-LOCKS

M-LOCKS Bravo BR5010 Technical manual

Alula BAT WIFI product manual

Alula

Alula BAT WIFI product manual

Sanmak SAE J845 operation instruction

Sanmak

Sanmak SAE J845 operation instruction

Edaphic Scientific ESRAD-200 operating instructions

Edaphic Scientific

Edaphic Scientific ESRAD-200 operating instructions

Barracuda PUMPS 691-3703 owner's manual

Barracuda PUMPS

Barracuda PUMPS 691-3703 owner's manual

Gorman-Redlich EAS-1 instructions

Gorman-Redlich

Gorman-Redlich EAS-1 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.