30120-85 Rev. 2.0 | 13AUG2019
Page 18
Specications
Copyright © 2014-2018 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published
technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data and
instructions. U.S. Patent 8,997,580 B2; foreign patents pending.
www.mccrometer.com
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA Printed In The U.S.A.
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078 Lit. # 30121-41, Rev. 1.8 / 4-2-18
Description and Operating Specications
Pipe Sizes 4", 6", 8", 10", 12"
Body Style Saddle mount
Pressure 150 psi (10.3 bar) working pressure
Accuracy ± 2% with default calibration
± 1% with custom Factory calibration
Conductivity Minimum conductivity of 50µS/cm, for lower conductive uid consult Factory.
Empty Pipe Detection Hardware/Software, conductivity-based (optional)
Electrical connects Optional shielded cable for 10-32VDC/4-20 mA output
Optional shielded cable for pulse out
Pipe Run Requirements 3D Upstream / 1D Downstream
Display and Measurement
Display 2-Line LCD display (no backlight), 16 characters per line
• Non-volatile memory
• Anti-reverse totalizer (standard)
• Total (to 9 digits of precision)
• Flow Rate and Velocity (to 5 digits of precision)
• Two alarms: low battery and empty pipe (optional)
To preserve battery life, a push-button on the housing activates the display.
Digits 5 Rate, 9 Total
Units US gallons, US gallons x1000, US gallons x1,000,000, cubic inches, cubic feet, cubic feet x1000, cubic centimeters,
cubic decimeters, milliliters, liters, deciliters, hectoliters, kiloliters, megaliters, cubic meters, cubic meters x1000,
acre feet, acre inches, imperial gallons, imperial gallons x1000, imperial gallons x1,000,000, standard barrels, oil
barrels, and miner inch days.
Rate scales: seconds, minutes, hours, and days.
Power
Battery Standard: three 3.6V lithium-thionyl chloride (Li-SOCI2) D size batteries. Batteries are eld replaceable
DC Power Linear power supply 10-35VDC, 2.4W
Battery Life Five-year expected battery life (three-year battery warranty)
Environmental
Operating Temperature -4° to 140°F (-20° to 60°C) sensor
Storage Temperature -40° to 149°F (-40° to 65°C)
Note: During freezing conditions and when meter is not in use, sensor must be removed from pipe and stored
in dry conditions. NOTE: Damage to the sensor caused by allowing the sensor freeze in the pipe is not covered
by the warranty.
Operating Pressure 150 PSI
Water Impermeability IP68 (submersible sensor)
Outputs
Pulse Output Digital pulse (open collector) output for volumetric and/or alarm
• Battery power only: 1 pulse output maximum
• DC powered version: 2 pulse outputs available
Analog Output 4-20mA (not galvanically separated from the power supply). DC powered option only.
Options and Accessories
• Data Logger - included as standard with ve years of data storage at default (12hr) interval. (Cable sold
separately)
• Epoxy coated carbon steel anged spool piece
• DC power w/battery backup: (Pulse & 4 20mA Out)
• Annual verication / calibration
• Stainless Steel ID tag
Materials
Sensor Body Fusion bonded epoxy coated stainless steel (316)
Electrodes Stainless steel (316)
Saddle Mount Stainless steel (304)
Saddle Hardware Stainless steel (304)
Electronic Housing IP-67 Certied diecast aluminum, powder coated enclosure w/ tamper resistant seal, 6½”x 6½”x 4/”tall
O-Ring SBR rubber D-ring
Boot Cover EPDM rubber
10.0 SPECIFICATIONS