SECTION MITL9103-098-100-NA
Central Proccessing Unit (CPU)
Terminal Strip
Reset Button
System Switches
Status
LED
Six Extension LED's
DTMF Receivers
PagingCiruitry
Music on HoldCircuitry
Call Progress Tone Generators.
Ringing Generator Circuitry
POWER SUPPLY CARD: contains all the
circuitry necessary to conven commercial
AC power to voltages necessary in the
operation of the system Satisfactory
operation of the system's voltage sources
are indicated by four illuminated LED's on
the Power Supply Card These LED's are
visible when the access door is opened
Refer to Figure
7-1,
SX-5 Equipment
Layout
TRUNK MODULE: plugs into the Main Card
and provides access to two CO trunks.
This module can be set for ground or loop
start operation There are two types of
Trunk Modules available. One type has a
nominal impedance of 900 ohms and the
other 600 ohms nominal impedance.
(dl MEMORY MODULE: plugs into the Main
Card This module includes:
Read Only Memory (PROMIROM) holding
the system operating instructions
Non-Volatile Random Access Memory (NV
RAM) containing the customer data base
Customer Data backup batteries protecting
the NV RAM against commercial power
failure and loss of customer data
Random Access Memory (RAM) containing
temporary data
8.
INSTALLATION AND MAINTENANCE
REQUIREMENTS
Note: Caution is necessary during installa-'
tion
and maintenance of any elec-
tronic equipment. such as the SX-5, to
avoid possible damage to the system
electronics by static discharge.
A
simple means of avoiding the pos-
sibility of such damage, is the use of
the "Static ProtectionWrist Strap" at-
tached to one cabinet hinge. MlTU
strongly advises the use of this wrist
strap; failure to do so can lead
to
im-
proper system operation and decreas-
ed system life.
lnstallation
8.01
The following requirements must be met
when selecting
a
location for the SX-5
equipment cabinet
The location MUST
BE
Dry and clean
Well ventilated
Well
lit
Easily accessible.
The location MUST NOT
BE
Near
a
sprinkler system, sweating pipes,
steam pipes, or steam vents
In
areas where corrosive fumes or exhaust
from machinery is present
Next to a reproducing or copying machine.
A minimum clearance of 10 feet
(3
m)
must be provided and the room should be
ventilated by
an
exhaust fan
if
the re-
producing machine is not equipped with a
filtering system.
8.02
lnstallation of the SX-5 consists of
5
steps:
1.
Mount the SX-5 vertically in the desired
location
2.
Set the system switch 1 (SW1) to
Direct Trunk. Select (OPEN) or Trunk
Group Operation (CLOSED).
3.
Connect the Trunk, Extension, Paging,
and Music on Hold pairs to the terminal
strip connector.
4.
Apply power to the system
5. Program ?he system,
if
necessary.
Refer to Section MITL9103-098-200-
NA. Shipping, Receiving and Installation
Procedures
Page 10