A.S. 06.07.04 ISSUE C
FILENAME: ATS-69020-2025c
ADJUSTMENTS
1) If termination height is incorrect then follow the
procedure below.
2) Loosen the stud nuts in the centre of the Arbor Press.
3) Loosen clamp bolt to column at the rear of the Arbor
Press.
4) Adjust upper part of Arbor Press up or down using the two
nuts on the central stud.
5) Re-tighten nuts and clamp bolt.
6) Recheck termination height.
MAINTENANCE
1) Keep fixture clean at all times.
2) Clean fixture with brush.
3) Oil moving parts weekly, when in use.
4) Store in a clean dry environment.
QUALITY
Check termination quality against the Molex wire termination
specification for relevant product being terminated eg: PS-
90650.
A quality procedure should be in place to monitor output from
this fixture.
LIMITATIONS
This Arbor Press Fixture can only be used for product stated
in the description of this leaflet.