Njoy Ranger 30KR User manual

Ranger 30KR User Manual
Manual de ulizare
UP33ROP130KRAAZ01B
Before using this product, carefully read all product documentaon and retain it for future reference.
233.24.23.0

2
Safety and EMC instrucons
1
Thank you for purchasing our products!
Please read this manual before using the product.
nJoy is a brand of power and backup protecon products that
create soluons for mulple levels of environment complexity,
residenal to industrial.
This UPS will protect your electronic equipment from physical
damage and will provide emergency baery backup power to
prevent data loss in the event of power problems.
All safety instrucons in this document must be read, understood and
followed.
1.1 Transportaon and Storage
Please transport the UPS system only in the original packaging to
protect against shock and damage.
The UPS must be stored in the room where the temperature is well
regulated. Ambient temperature should not exceed 40°C.
1.2 Preparaon
Condensaon may form if the UPS system is moved immediately from
cold to warm environment. The UPS system must be absolutely dry before
being installed. Please allow at least two hours for the UPS system to
acclimate the environment.

3
English
Română
Do not install the UPS system near water or in moist environments.
Do not install the UPS system where it would be exposed to direct
sunlight or nearby heat source.
Do not block venlaon holes on the UPS housing.
1.3 Installaon
Do not connect appliances or devices which would overload the UPS
(e.g. big motor-type equipment)) to the UPS output terminal.
Place cables in such a way that no one can step on or trip over them.
Do not block air vents on the housing of the UPS. Ensure proper unit
spacing of venlaon.
UPS came equipped with grounding terminal, in the nal installaon
phase, connect grounding/earthing wire to the external UPS baery
cabinets or appropriate grounding terminals.
The UPS can be installed only by qualied maintenance personnel.
An appropriate disconnect device such as short-circuit backup
protecon should be incorporated during installaon.
An integral emergency shuto switch which prevents addional load
from the UPS in any mode of operaon should be implemented during the
installaon.
Secure the grounding/earthing wire before connecng to any live wire
terminal.
Installaon and Wiring must be in accordance with the local electrical
laws and regulaons.

4
1.4 Connecon Warnings
There is no standard backfeed protecon inside of the UPS. However,
there are relays on the Input to cut o line voltage and while the neutral is
sll connect to UPS.
This UPS should be connected with TN grounding/earthing system.
The power input for this unit must be three-phase rated in accordance
with the equipment nameplate. It also must be suitably grounded.
Use of this equipment in medical instrument of any life-sustaining
equipment where failure of this equipment can reasonably be expected to
cause the failure of the life-sustaining equipment or to signicantly aect
its safety or eecveness is not recommended. Do not use this equipment
in the presence of a ammable mixture with air, oxygen or nitrous oxide.
Connect grounding terminal of UPS to a grounding electrode conductor.
In accordance with safety standard EN-IEC 62040-1, installaon
has to be provided with a «Backfeed Protecon» system, as for example
a contactor, which will prevent the appearance of voltage or dangerous
energy in the input mains during a mains fault (see gure 24 and respect the
wiring diagram of «Backfeed Protecon» depending if the equipment is with
signal or three phase input).
HIGH LEAKAGE CURRENT! EARTH CONNECTION ESSENTIAL
BEFORE CONNECTING SUPPLY.
WARNING
UPS
Main
Input
Input Rly
Input relay diagram Input relay diagram for
dual-input model
L1
L2
L3
L1
L2
L3
L1
L2
L3
N
UPS
Main
Input
Bypass
Input
Input Rly
Input Rly
N
N

5
English
Română
Before working on this circuit!
- Isolate Uninterruptible Power Supply (UPS).
- Then check for Hazardous Voltage between all terminals
including the protected earth.
Risk of Voltage Backfeed!
WARNING
1.5 Operaon
Do not disconnect the grounding/earthing conductor cable on the UPS
or the building wiring terminals under any circumstance.
The UPS system features its own, internal current source (baeries).
The UPS output sockets or output terminal blocks may be electrically live
even if the UPS system is not connected to the building mains/live wires.
(only for standard models).
In order to fully disconnect the UPS system, rst press the “OFF” buon
and then disconnect the mains/live wires.
Ensure that no liquid or other foreign objects can enter into the UPS
system.
The UPS can be operated by any individuals with no previous
experience.
There can be no derivaon in the line that goes from the «Backfeed
Protecon» to the UPS, as the standard safety would be infringed.
Warning labels should be placed on all primary power switches installed
in places away from the unit to alert the electrical maintenance personnel
of the presence of a UPS in the circuit. The label will bear the following or
an equivalent text:

6
2.1 Unpacking and Inspecon
Unpack the package and check the package contents. The shipping
package should contain:
● One UPS
● One user manual
● One monitoring soware CD
● One RS-232 cable (opon)
● One USB cable
● One parallel cable (only available for parallel model)
● One shared current cable (only available for parallel model)
These series came with
Oponal parallel funcon upon request. The UPS with parallel funcon
is called the “Parallel model”. We have detail installaon and operaon
procedure of the Parallel Model in the following chapter.
2Installaon and Operaon
VAC System Model Type
400V Ranger 30KR Long-run
model
NOTE!
Before the installaon, please inspect the unit. Be sure that there is no physical
damage to the unit. Do not turn on the unit and nofy the carrier and dealer
immediately if there is any damage or missing parts and accessories. Please
keep the original packaging for future use. It is recommended to keep each
equipment and baery set in their original packaging because they have been
designed to provide maximum protecon during transportaon and storage.

7
English
Română
2.2 Wiring Terminal View
Diagram 2: Ranger 30KR Rear panel
1. Power switch
2. External maintenance bypass switch port
3. USB communicaon port
4. Emergency power o funcon connector (EPO connector)
5. Share current port (only available for parallel model)
6. Parallel port (only available for parallel model)
7. Intelligent slot
8. External baery connector
9. Line input terminal
10. Output terminal
11. Bypass input terminal
12. Input grounding terminal
13. Output grounding terminal
14. RS232 port
Diagram 1: Front panel

8
NOTE 1: The cable for Ranger 30KR should be able to withstand over 60A
current. It is recommended to use AWG8 or thicker wire for Phase and
AWG 4 or thicker wire for Neutral for safety and eciency.
NOTE 2: The selecons for color of wires should be followed by the local
electrical laws and regulaons.
2) Switch o the mains switch in the building before installaon.
3) Turn o all the connected devices before connecng to the UPS.
4) Prepare wires based on the following table:
NOTE!
Do not use the wall receptacle as the input power source for the UPS, as its
rated current is less than the UPS’s maximum input current. The receptacle
may be damaged and destroyed.
2.3 Single UPS Installaon
Installaon and wiring must be carried out in accordance with the local
electric laws and regulaons by trained professionals.
1) Make sure that the mains wire and breakers of the building are rated for
the capacity of the UPS to prevent electric shock or risk of re.
5) Remove the terminal block cover at the rear panel of UPS. Then connect
the wires according to the following terminal block diagrams: (Connect
the grounding/earthing wire rst when making other wire connecons.
Remove the grounding/earthing wire last when connecng the UPS!)
NOTE!
For dual input model with single input power system, connect input terminals
to the AC power source and connect input and bypass input together (shows
dashed line in below wiring diagrams).
Model Wiring spec (AWG)
Input(Ph) Output(Ph) Neutral Baery Ground
Ranger 30KR 8 8 4 6 4

9
English
Română
6) Put the terminal block cover back at the rear panel of the UPS.
Battery wires connection schematic
PBAT
NBAT
TO UPS BAT+
TO UPS BAT N
TO UP AT-
Terminal block wiring diagram
NOTE 1: Make sure that the wires are connected securely with the
terminals.
NOTE 2: Please install the output breaker between the output terminal
and the load, and the breaker should have leakage current protecve
funcon if necessary.
SB

10
● Make sure a DC breaker or other protecve device between
UPS and the external baery pack is installed for added safety. If
not, please install it carefully. Switch o the baery breaker before
installaon.
NOTE: Set the baery pack breaker in “OFF” posion and then
install the baery pack.
● Pay special aenon to the rated baery voltage marked on
the rear panel. If you want to change the numbers of the baery
in a chain, make sure you modify the UPS seng accordingly.
Connecon with wrong baery voltage may cause irreversible
damage of the UPS.
● Pay special aenon to the polarity marking on external baery
terminal block. Connecon with wrong baery voltage may cause
irreversible damage of the UPS.
● Make sure the protecve grounding/earthing wiring is adequate.
The current spec, color, posion, connecon and conductance
reliability of the wire should be veried.
● Make sure the ulity input & output wiring is rated correctly.
The current spec, color, posion, connecon 8 and conductance
reliability of the wire should be veried. Make sure the L/N side is
correct, not reverse or short-circuited.
WARNING
2.4 UPS Installaon for Parallel System
If the UPS is only for single operaon, you may skip this secon.
1) Install and wired the UPS according to the secon 2-3.
2) Connect the output wires of each UPS to an output breaker.
3) Connect all output breakers to a major breaker. This major output
breaker will then connect directly to the loads.
4) Either common baery packs or independent baery packs for each
UPS are allowed.

11
English
Română
5) Refer to the following wiring diagram:
Wiring diagram of parallel system
2.5 Soware Installaon
For opmal computer system protecon, install UPS monitoring soware
to congure UPS shutdownoperaon.
Operaons
3
3.1 Buon Operaon
1) Before operaon, make sure that the two strings of baeries are
connected correctly in order of ”+,GND,-” terminals and the breaker of the
baery pack is at “ON” posion (only for long-run model).
2) Press the “ Power” buon to set up the power supply for the UPS.
UPS will enter into power on mode. Aer inializaon, UPS will enter into
“No Output mode”.

12
3.2. Screen Descripon
Aer inializaon, the LCD will display main screen. There are ve sub-
menus: Control, measure, seng, informaon and data log. Touch any
sub-menu icon to enter into the sub-screen.
Menu tree
3.1 Buon Operaon
1) Before operaon, make sure that the two strings of baeries are
connected correctly in order of ”+,GND,-” terminals and the breaker of the
baery pack is at “ON” posion (only for long-run model).

13
English
Română
3.2.1 Main screen
Upon powering on, the LCD will start inializaon approximately few
seconds as shown below.
Aer inializaon, the main screen will display as shown below.

14
Aer touching the icon, it will show ve icons in center to represent
ve sub-menus: Control, measure, seng, informaon, data log.
3.2.2 Control screen
Touch the icon to enter control sub-menu.

15
English
Română
Touch icon will return back to main screen no maer it’s in any screen
of any submenu.
On/O UPS
It will show “On UPS?” when UPS is o.
It will show “O UPS?” when UPS is on.
Touch “YES” to turn on or o the UPS. Then, the screen will return to
main screen.
Touch “Back” to return to main screen immediately or “No” to cancel this
operaon and back to main screen.
Single machine cannot do this
Screen 1.0 «Control» and its sub-menus
TURN ON UPS TURN OFF UPS

16
Baery Test
It will show “Start Baery Test” if the UPS is not in test. Touch “Yes” to start
baery test. Then, it will start baery tesng. Aer few seconds, baery
test result will show on the screen. Touch “Back” to return to main screen
immediately or “No” to cancel this operaon and back to main screen.
It will show “Stop baery test” if the UPS is in test.
Baery Test TURN OFF UPS
Mute All Cancel Mute all
Mute All
It will show “Mute all” if the audio is acve. Touch “Yes” to acvate mute.
If “Mute all” is acve, it will show icon on the top le corner of the
main screen. Touch “Back” to return to CONTROL screen immediately or
“No” to cancel this operaon and back to CONTROL screen.
It will show “Cancel mute all” if the UPS is mute already. Touch “Yes” to
acvate audio funcon or

17
English
Română
LCD Change
When LCD is in “Rack Display”, if you touch “LCD Change” icon, it will pop-
up “Tower Display” window.
When LCD is in “Tower Display”, if you touch “LCD Change”, it will pop-up
“Rack Display” window.
Touch ”Yes” icon to change LCD Display.
Touch “No” icon to cancel this operaon and back to CONTROL screen.
Touch “HOME” to return to main screen.
Tower Display Rack Display
Exit Parallel
If the UPS is set as parallel mode, you can touch this icon to stop parallel
mode.
Touch “Yes” to stop parallel mode and enter into standby mode.
Touch “No” to cancel this operaon and back to CONTROL screen.
If the UPS is operated in single mode, even you touch this icon, it will pop-
up “This mode can’t be setup” window.
Touch “HOME” to return to main screen.
Exit Parallel This mode can’t be setup

18
3-2-3. Measure screen
Touch the icon to enter measure page. Touch the icon or
to browse informaon.
Touch the icon to return to main screen. Touch the icon to go back
to previous menu.
LINE VOLT: The real me value of L1, L2 and L3 phase voltage, L1L2/
L2L3/L3L1 voltage and input
frequency.
BYPASS VOLT: The real me value of L1, L2 and L3 bypass voltage,
L1L2/L2L3/L3L1 voltage and frequency.
Measure screen page 1
Measure screen page 2

19
English
Română
INVERTER VOLT: The real me value of L1, L2 and L3 inverter
voltage, L1L2/L2L3/L3L1 voltage and frequency.
OUTPUT VOLT: The real me value of L1, L2 and L3 output voltage,
L1L2/L2L3/L3L1 voltage and
frequency.
INPUT W: L1, L2 and L3 input power in wa.
INPUT W (%): L1, L2 and L3 input power wa in percentage.
Measure screen page 3
Measure screen page 4

20
OUTPUT VA: L1, L2 and L3 output power in VA.
OUTPUT VA (%): L1, L2 and L3 output power VA in percentage.
Measure screen page 5
OUTPUT W: L1, L2 and L3 output power in wa.
OUTPUT W (%): L1, L2 and L3 output power wa in percentage.
Measure screen page 6
INPUT VA: L1, L2 and L3 input power in VA.
INPUT VA (%): L1, L2 and L3 input power VA in percentage.
This manual suits for next models
1
Table of contents
Languages:
Other Njoy UPS manuals

Njoy
Njoy Cadu 650 User manual

Njoy
Njoy Garun Series User manual

Njoy
Njoy Keen Series User manual

Njoy
Njoy UPCMCOP130HBAAZ01B User manual

Njoy
Njoy Echo Pro Series User manual

Njoy
Njoy Helios PRO Series User manual

Njoy
Njoy Soter 600 User manual

Njoy
Njoy Aten PRO Series User manual

Njoy
Njoy Protector 801 User manual

Njoy
Njoy Shed 625 User manual

Njoy
Njoy Septu Series User manual

Njoy
Njoy Argus Series User manual

Njoy
Njoy Balder Series User manual

Njoy
Njoy Cadu Series User manual

Njoy
Njoy Horus Plus Series User manual

Njoy
Njoy Eris 600 User manual

Njoy
Njoy Token Series User manual

Njoy
Njoy Alvis Series User manual

Njoy
Njoy Ranger Series User manual

Njoy
Njoy Eido 600 User manual