NOVUS AUTOMATION. 1/3
NP
640
RELATIVE
PRESSURE TRANSMITTER – INSTRUCTIONS MANUAL – V1.0x F
PRESENTATION
The NP640 positive relative pressure transmitter series are robust
and reliable equipment suitable for general industrial applications. Its
great advantage is the possibility of a fast and easy configuration of
the operating range. With the aid of a software, the user has access
to the most important information of the transmitter and can set the
most appropriate configuration for the process.
PRECAUTION
Before operating the transmitter, carefully read its specifications and
operating instructions. In case of damage caused by incorrect
operation or inappropriate usage, and its consequences, the
guarantee becomes ineffective and null.
A specialized professional shall perform the installation.
A specific electrical power supply network should be provided for
instruments use only.
UNPACKING
After unpacking the product, besides the transmitter it must be
available:
•A quick guide to installation and operation.
•A sealed electrical connector.
•A screw to adjust the transmitter and the connector.
IDENTIFICATION
An identification label is attached to the equipment housing. On this
label, you can found detailed information about the transmitter.
Fig. 1 shows the identification label with their respective information.
Fig. 1 – Transmitter identification
SPECIFICATIONS
Type of Measure:
Positive relative pressure
Maximum Range (Max. Range):
0-1 / 0-4 / 0-10 / 0-40 / 0-100 Bar (*)
Rangeability:
3:1
Measurement Accuracy:
< ±0.25 % of the maximum Range (Max. Range)
Including linearity, hysteresis and repeatability, 25 °C
Thermal Maximum Deviation:
< ±0.05 % Max. Range / °C
Overpressure Range:
Twice the value specified for the Maximum Measurement Range
Output Signal (Output):
Electric currente, 4-20 mA, 2 wires.
Power Supply (Power):
11 to 33 Vdc
Degree of Protection:
IP65
Electrical Connection:
Connector for Type A valves (DIN EN 175301-803), IP65.
Conductor 1.5 mm² (max.) and cables between 6 and 8 mm in
diameter.
Operating temperature:
-20 to 70 °C
Dinamic Response:
< 30 ms
Process Conection (Thread):
¼ NPT; ½ NPT; ½ BSP, G ¼ (*)
Sensor features:
Polysilicon Piezoresistive (silicone oil filled)
Metal housing of the transmitter:
Stainless 316
Wetted parts:
Sensor, stainless steel 316
Metal Connection, stainless steel 316
Compatibility: Any gas or liquid compatible with the constituent
materials of the wetted parts.
(*)Information available on the product identification label.
Certification:....................................................................................CE
NP640 Pressure Transmitter
NOVUS AUTOMATION 2/3
ELECTRICAL CONNECTIONS
Fig. 2 – Electrical Connections
For troubleshooting, visit our FAQ at www.novusautomation.com.
Recommendations for installation
•Sensor signals conductors must go through the plant system
separate from power leads (loop), if possible in grounded
conduits.
•The instruments must be powered from the instrumentation power
supply circuit.
•It is mandatory the use of RC FILTERS (electrical noise
suppressors) in contactor coils, solenoids, etc.
•To improve the stability, immunity and safety of the measurement,
it is recommended to use the system grounding.
CONFIGURATION
When the transmitter is used with the factory setting, no further
action is required and the transmitter is ready to be installed.
When a new configuration is required, you should use the
Transmitter Configuration Kit. This kit includes the TxConfig-II
software, distributed free on our website, and the TxConfig-USB-
DIN43650 interface, which can be purchased in our distribution and
reseller network.
To install the TxConfig-II software, run the setup file
TxConfigIISetup.exe and follow the instructions of the installer.
The TxConfig interface must be connected to the transmitter
according to Fig. 3. The interface itself provides the electrical power
necessary for transmitter operation during configuration.
Fig. 3 – Connection of the TxConfig-USB
SOFTWARE CONFIGURATION
Fig. 4 – TxConfig II software main screen
When you run the TxConfig-II software, it will recognize
automatically the transmitter and will display the following
information:
1. General Information:
This field shows information that identifying the transmitter. This
information should be sent to the manufacturer in an eventual
request for technical assistance.
2. Unit:
Setting the pressure unit assumed for the measuring range
setting fields.
3. Measuring Range:
Setting the measurement range assumed by the transmitter.
Lower Limit: target pressure value for 4 mA current.
Upper Limit: target pressure value for 20 mA current.
Minimum Range
Do not set a lower band (span) that the Minimum Range
indicated below in this same field.
4. Sensor Failure: Sets the current output behaviour when the
transmitter experiences a fault:
Minimum: output current goes to < 4 mA
Maximum: output current goes to > 20 mA
5. Zero Correction: It corrects small deviations presented in the
transmitter output, when there is no applied pressure.
6. Send Configuration: It applies the new setup. Once sent, the
setup will be immediately adopted by the transmitter.
7. Read Configuration: Reads the current setup in the transmitter
connected. The screen now presents the current setup that may
be changed by the user.
NP640 Pressure Transmitter
NOVUS AUTOMATION 3/3
DIMENSIONS
Fig. 5 – Transmitter dimensions
THREAD A (mm) B (mm) WEIGHT (g)
NPT ¼ 15.5 62.9 135
NPT ½ 20.0 67.2 166
BSP ½ 14.0 61.0 145
G ¼ 14.0 61.0 129
Table 1 – Dimensions
WARRANTY
Warranty conditions are available on our website
www.novusautomation.com/warranty.

Other Novus Transmitter manuals

Novus TxIsoPack-HART User manual

Novus

Novus TxIsoPack-HART User manual

Novus TEMP-WM User manual

Novus

Novus TEMP-WM User manual

Novus TxBlock-USB User manual

Novus

Novus TxBlock-USB User manual

Novus TxIsoRail-HRT User manual

Novus

Novus TxIsoRail-HRT User manual

Novus NV-202VIP User manual

Novus

Novus NV-202VIP User manual

Novus NP785 User manual

Novus

Novus NP785 User manual

Novus RHT-WM User manual

Novus

Novus RHT-WM User manual

Novus NP620 User manual

Novus

Novus NP620 User manual

Novus RHT Climate WM User manual

Novus

Novus RHT Climate WM User manual

Novus TXMINI-M12 User manual

Novus

Novus TXMINI-M12 User manual

Novus NP600 User manual

Novus

Novus NP600 User manual

Novus TxIsoBlock-HRT User manual

Novus

Novus TxIsoBlock-HRT User manual

Novus TxBlock-USB User manual

Novus

Novus TxBlock-USB User manual

Novus NVPT-131VTP-HD User manual

Novus

Novus NVPT-131VTP-HD User manual

Novus TxIsoPack User manual

Novus

Novus TxIsoPack User manual

Novus RHT-P10 User manual

Novus

Novus RHT-P10 User manual

Novus TxIsoRail 0-10 Vdc User manual

Novus

Novus TxIsoRail 0-10 Vdc User manual

Novus TXMINI-DIN43650 User manual

Novus

Novus TXMINI-DIN43650 User manual

Novus TxRail-USB User manual

Novus

Novus TxRail-USB User manual

Novus NP400 User manual

Novus

Novus NP400 User manual

Novus TxIsoRail User manual

Novus

Novus TxIsoRail User manual

Novus TL400-V User manual

Novus

Novus TL400-V User manual

Novus NP785 User manual

Novus

Novus NP785 User manual

Novus RHT-Air User manual

Novus

Novus RHT-Air User manual

Popular Transmitter manuals by other brands

CYP CPLUS-12FTX Operation manual

CYP

CYP CPLUS-12FTX Operation manual

Sony WRT-860A operating instructions

Sony

Sony WRT-860A operating instructions

Panasonic TY-3DTRW operating instructions

Panasonic

Panasonic TY-3DTRW operating instructions

Hoymiles HRSD-2C Quick installation guide

Hoymiles

Hoymiles HRSD-2C Quick installation guide

Phonak Inspiro DynaMic user guide

Phonak

Phonak Inspiro DynaMic user guide

WisyCom MTP61 Quick user guide

WisyCom

WisyCom MTP61 Quick user guide

LPB AM-60P instruction manual

LPB

LPB AM-60P instruction manual

Endress+Hauser Memograph CVM40 Brief operating instructions

Endress+Hauser

Endress+Hauser Memograph CVM40 Brief operating instructions

Ashcroft km11 instruction sheet

Ashcroft

Ashcroft km11 instruction sheet

Burkert 8176 Safety instructions

Burkert

Burkert 8176 Safety instructions

Emerson Rosemount 3101 Reference manual

Emerson

Emerson Rosemount 3101 Reference manual

Kanardia Daqu installation manual

Kanardia

Kanardia Daqu installation manual

Zaxcom TRXFB3 user manual

Zaxcom

Zaxcom TRXFB3 user manual

Lippert 179839 manual

Lippert

Lippert 179839 manual

DigitaLinx DL-3H1U-WP-W owner's manual

DigitaLinx

DigitaLinx DL-3H1U-WP-W owner's manual

Hides HV-320 Quick installation guide

Hides

Hides HV-320 Quick installation guide

Vega VEGABAR 83 operating instructions

Vega

Vega VEGABAR 83 operating instructions

MMcall T10 user manual

MMcall

MMcall T10 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.