  9. NuWave OXYPURE ZERO E1000 User manual

NuWave OXYPURE ZERO E1000 User manual

Getting Started
Button Name Function Use
POWER Turns the OxyPure®on and off. Press Power to turn the OxyPure®on and off.
AUTO Allows you to run the OxyPure at the lowest fan
speed, raising it based on air quality.
Press AUTO and the Auto back light will turn on. There is no time limit on the Auto Mode. Press
AUTO again to deactivate Auto Mode.
ECO
MODE Allows you to save energy by turning the OxyPure
fan off when it is not needed.
Press and hold AUTO for 1 second to activate Eco Mode. When the air quality is poor, the unit will
automatically run. When the air quality is good, the unit will turn off. Press AUTO and hold for 1
second to deactivate Eco Mode.
ULTIMATE
CLEAN
Automatically adjusts to the highest speed for
maximum cleaning based on the air quality. Press ULTIMATE CLEAN to activate the Ultimate Clean Mode.
FLOW
ANGLE Adjusts the louver angles. Press AIR FLOW ANGLE to adjust the louver angles from 30°, 60°, 90°.
FAN
SPEED Adjusts the OxyPure’s fan speed. There are 6 fan speed levels. Press FAN SPEED to adjust from Speed 1 (lowest) to Speed 6
(highest).
SLEEP
MODE
Turns off the control panel LED lights but keeps the
fan active.
Adjust the Fan Speed prior to activating Sleep Mode. Press and hold FAN SPEED for 2 seconds
to activate Sleep Mode. Press any button to deactivate it.
TIMER Helps limit the amount of time the OxyPure is on. The timer is adjustable from ½ hour to 1, 2, 4, 8, or 12 hours. To set the timer, press TIMER.
TURBO Cleans the air using the highest speed for a set time
(½ hour, 1, or 2 hours).
Press TURBO once to run the OxyPure at the highest speed for ½ hour. Press TURBO twice for 1
hour. Press TURBO three times for 2 hours.
See the Owner’s Manual for details.
E1000
Air/Odor Quality - Detects particles as small as 2.5/1000mm
Particulate Matter (PM) with a diameter of 2.5 microns or less
0~5 5~10 10~20 20~30 30~50 Over 50
Fan Speeds
1 2 3 4 5 6
DirtyClean
Quick Start Guide
Refer to the Owner’s Manual for more details
Model No: 47251 / 47261
Wi-Fi Connection (Optional)
The OxyPure®’s Wi-Fi lets you operate it from anywhere.
To set up and activate the Wi-Fi:
1. Download the NuWave®Connect app (Apple Store or Google™Play) to your
smart device.
2. Connect your device to your Wi-Fi network, open the app, go through the
verification process, and add the OxyPure by tapping “+” then selecting
“OxyPure”.
3. Activate Wi-Fi Pairing Mode by holding ULTIMATE CLEAN until the Wi-Fi
light begins to rapidly blink. Then tap Next on the bottom of the Add Device
page in the app.
4. Next, you will be prompted to either connect to your network or confirm your
existing network password to ensure that your connection is secure.
5. When the OxyPure is connected, the Wi-Fi light will stay continuously lit
green. If the connection fails, the Wi-Fi light will turn off. Repeat steps
3-4, ensuring that the Wi-Fi network and password are correct.
Wi-Fi LED Status
Pairing Mode & Standby Mode
Solid Light The OxyPure®is paired with the Wi-Fi and ready to
be used.
Rapid Blinking Light
The OxyPure is in Pairing Mode. The OxyPure will
remain in Pairing Mode for up to 3 minutes, or until
your device is paired.
Slow Blinking Light The OxyPure is in Standby Mode.
No Light The OxyPure’s Wi-Fi is off.
Note: If the light on your OxyPure is blinking slower, the OxyPure is in Wi-Fi
Standby Mode. To exit Standby Mode and initiate the Pairing Mode, press and
hold ULTIMATE CLEAN until the Wi-Fi light begins blinking rapidly.
Note:
• To reset the OxyPure’s Wi-Fi, hold down ULTIMATE CLEAN until the
WIFI light is rapidly blinking. Follow step 4.
• To connect to or change networks, depending on your cellular
service, you may need to remove the app and reinstall it to complete
the connection before continuing with the setup process.
The OxyPure will only connect to a 2.4GHz network (standard for most
routers). If you need help activating 2.4GHz on your network, contact
your Internet Service Provider.
Before Use
1. Make sure the OxyPure® is unplugged. Open the panel on the back to
expose the lters.
2. Pull the lters from their slots.
3. Remove the plastic wrapping from the lters.
4. Fully reinsert the lters into the Oxypure and close the panel.
5. Remove the sticker from the control panel.
1
4
23
Filters
1 2 Bio-Guard®Filters (Lifespan up to 20 years)
• 8,000-volt electrostatic filter kills 99.99% of mold, bacteria, and viruses.
• Captures 100% of particles and pollutants as small as 0.1 microns in
120 minutes.
3 Ozone (O3) Emission Removal Filter (Lifespan up to 20 years)
• Eliminates harmful ozone gas (O3) from the home to less than 3 part
per billion (ppb), 17 times less than the EPA’s household standards
of 50 ppb by converting Ozone to Oxygen.
4 Stainless-Steel Prefilter (Lifespan up to 20 years)
• Made from rust-free 18/8 stainless-steel.
• The durable, washable, and reusable Prefilter captures and collects
large particles, pollutants, and allergens including pet hair, dander,
and pollen.
Air Filter Assembly
When maintaining the lters, unplug the unit and open the Filter Access Panel. You will see that
the order of the lters, from the outside in, is as follows:
Stainless-Steel Prefilters
Bio-Guard® filters
Ozone Emission Removal filter
Bio-Guard®360 filter
1 2
4
332 1
4
3
2
1
The OxyPure® is easily movable with wheels on the bottom. Before moving your OxyPure, turn it off and unplug it from the outlet. Your settings will be
saved and will automatically activate next time the unit is turned on.
Cleaning & Maintenance
Filter Maintenance Indicator
The FILTER 2 and FILTER 4 lights will turn green in about 3 months to alert you that the Bio-Guard® lters SHOULD be cleaned to maintain
optimal performance (NuWave Recommendation). When either light turns red (after about 6 months), that Bio-Guard® lter MUST be cleaned.
Once cleaned, press and hold down TIMER until a beep is heard to reset the Clean Filter 2 Indicator. To reset the Clean Filter 4 light, hold the
TURBO button for 2 seconds until a beep is heard. Once the Clean Filter lights are reset, they will go out.
Cleaning the Filters
The lters need to be cleaned on schedule to help the unit maintain optimum performance.
1. Remove the Filter Access Panel in the rear of the OxyPure®using its built-in handle.
2. Slide out the lters that need cleaning.
3. Always allow the washable lters to dry completely, out of direct sunlight, before you reinstall them. Never place a wet lter into the OxyPure.
4. Reattach and close the Filter Access Panel. If the panel is not properly closed, the POWER button will blink red and the unit will not power on.
CAUTION
Unplug the OxyPure® from the power source before inserting or
removing any parts or attachments and before cleaning.
Cleaning the Dust Sensor
The Dust Sensor is located on the side of the unit.
1. Open the Dust Sensor Cover.
2. Using a dry cotton swab or small, soft brush, gently remove any dirt or
dust from the Dust Sensor.
3. For more buildup on the Dust Sensor, wipe it with a slightly wet
cotton swab.
4. Remove any moisture with a dry cotton swab.
• The Dust Sensor requires regular cleaning (approximately every 3
months) for the unit to operate efficiently.
• If your OxyPure is set up in an area with high dust accumulation,
more frequent cleaning of the Dust Sensor is needed.
• Do not use the cotton swab on any part or area other than the
Dust Sensor.
Do not immerse the OxyPure in water. Clean the outside of the
unit with a damp sponge or cloth and wipe it dry. Make sure all
parts and covers are securely attached.
Do not dry the lters in direct sunlight or with a hot blow dryer.
Do not use a vacuum cleaner or too stiff a brush to clean the
Bio-Guard lters or Prelters.
Note: If you are unable to close the Filter Access Panel for any
reason, the OxyPure will not operate and you will need to contact
NuWave Customer Service. Exercise caution to ensure the tabs
are not damaged when securing the Filter Access Panel.
©2022 NuWave®LLC • All Rights Reserved. • Customer Service: 1-877-689-2838 • help@nuwavenow.com
Model: 47251 /47261 • 10-14-22 • Item No: BQ47251-47261 • CB-Rev.03
General Filter Cleaning Tips
1. Always Wear a Mask
Prevents accidental inhalation of any contaminants when cleaning
your lters.
2. Move the OxyPure, Not the Filters
Minimizes lter shaking.
3. Handle the Filters Carefully
Be careful not to agitate the lters to avoid releasing trapped
contaminants.
4. Dry the Filters Completely
Never install a wet or damp lter into your OxyPure.
Tab
Sensor
To Clean the Ozone Emission Removal Filters
1. Remove the lters. If possible, take them outside to clean.
2. Gently, but thoroughly, clean the lters using a brush-tipped vacuum.
3. Repeat the process on the other side. DO NOT GET WET.
To Clean the Stainless-Steel Prelters
The Prelters need to be cleaned at least once every two months,
depending on use.
1. Use a brush-tipped vacuum to remove any dust or lint.
Cleaning the Odor Sensor
1. The Odor Sensor is behind the three slots above the Dust Sensor
Cover and may ONLY be cleaned using a brush-tipped vacuum.

Other manuals for OXYPURE ZERO E1000

3

This manual suits for next models

2

Other NuWave Air Cleaner manuals

NuWave 47401 User manual

NuWave

NuWave 47401 User manual

NuWave OXYPURE 47001 User manual

NuWave

NuWave OXYPURE 47001 User manual

NuWave OXYPURE ZERO E1000 User manual

NuWave

NuWave OXYPURE ZERO E1000 User manual

NuWave OxyPure Zero E500 User manual

NuWave

NuWave OxyPure Zero E500 User manual

NuWave OXYPURE ZERO E1000 User manual

NuWave

NuWave OXYPURE ZERO E1000 User manual

NuWave OxyPure Zero E500 User manual

NuWave

NuWave OxyPure Zero E500 User manual

NuWave OxyPure BM47001 User manual

NuWave

NuWave OxyPure BM47001 User manual

NuWave OxyPure User manual

NuWave

NuWave OxyPure User manual

NuWave OXYPURE 47501 User manual

NuWave

NuWave OXYPURE 47501 User manual

NuWave OxyPure HEPA 300 User manual

NuWave

NuWave OxyPure HEPA 300 User manual

NuWave OxyPure User manual

NuWave

NuWave OxyPure User manual

NuWave OXYPURE 47501 User manual

NuWave

NuWave OXYPURE 47501 User manual

NuWave OXYPURE 47001 User manual

NuWave

NuWave OXYPURE 47001 User manual

NuWave OXYPURE ZERO E1000 User manual

NuWave

NuWave OXYPURE ZERO E1000 User manual

NuWave OXYPURE ZERO 47251 User manual

NuWave

NuWave OXYPURE ZERO 47251 User manual

NuWave OxyPure User manual

NuWave

NuWave OxyPure User manual

NuWave OXYPURE ZERO 47251 User manual

NuWave

NuWave OXYPURE ZERO 47251 User manual

Popular Air Cleaner manuals by other brands

Beko ATP8100 user manual

Beko

Beko ATP8100 user manual

FitAir Halo Instructions for use

FitAir

FitAir Halo Instructions for use

Best Living Systems MCI ProtectAIR owner's manual

Best Living Systems

Best Living Systems MCI ProtectAIR owner's manual

Airpura Tobacco Smoke T600 Technical specifications

Airpura

Airpura Tobacco Smoke T600 Technical specifications

SEELEY INTERNATIONAL MEGACOOL MIV owner's manual

SEELEY INTERNATIONAL

SEELEY INTERNATIONAL MEGACOOL MIV owner's manual

Airgle PurePal AG900 user manual

Airgle

Airgle PurePal AG900 user manual

MIJIA Air Purifier Pro user manual

MIJIA

MIJIA Air Purifier Pro user manual

ELIXAIR E200 instructions

ELIXAIR

ELIXAIR E200 instructions

Honeywell UV2400U installation instructions

Honeywell

Honeywell UV2400U installation instructions

Tion Clever user manual

Tion

Tion Clever user manual

Husqvarna A 1000 Operator's manual

Husqvarna

Husqvarna A 1000 Operator's manual

Trion HE Plus 1400 Installation & operation

Trion

Trion HE Plus 1400 Installation & operation

Panasonic F-GMG01H operating instructions

Panasonic

Panasonic F-GMG01H operating instructions

activTek PURECLOUD owner's manual

activTek

activTek PURECLOUD owner's manual

Blueair Airpod instruction manual

Blueair

Blueair Airpod instruction manual

Nu-Calgon GPS iWave-V Instruction bulletin

Nu-Calgon

Nu-Calgon GPS iWave-V Instruction bulletin

cecotec TOTALPURE 4000 LIGHT OZONE instruction manual

cecotec

cecotec TOTALPURE 4000 LIGHT OZONE instruction manual

Sharp IZCA10EKW Replacement guide

Sharp

Sharp IZCA10EKW Replacement guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.