
Page 1 from 4922044006_09_024
SLD-34/SP SLD-44/SP
SLD-28/SP
220-240V AC/50-60Hz
3h
24h
Overcharging and deep discharging protection
Charge LED, Lamp LED, Fault LED, Test Button
IP30
3.6V/1.5Ah
100lm /100lm 125lm /125lm
9.5 VA9 VA
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3, EN 1838
5 to 40 C
o
up to 95%
Bayblend FR3010, aluminum, plexiglas
280x120x15mm
3 years (1 year for the battery)
790gr. 1110gr. 1580gr.
340x190x15mm 440x240x15mm
289x65x34mm
TECHNICAL CHARACTERISTICS (for LED MODULE specifications see page 4)
SELF TESTING MAINTAINED EMERGENCY ILLUMINATION SIGNS WITH WHITE LEDs
GENERAL
The luminaire consists mainly from two Battery Cut-off
parts, the body, where all the electronics The luminaire enters in this operation when
are located and the lamp-head where the the mains power supply fails and battery
indication sign and the high efficiency has lost its energy. During this operation
LEDs are located. the luminaire enters the idle state and
battery consumption is negligible, in order
Maintained to non-maintained selection to be protected from deep discharge.
capability
Power on the device and press Manual Test
continuously the TEST button for 10 The manual test can be conducted only if
seconds, until the led strip turns off. the mains power supply and the battery is
Release the button and after a short connected. By pressing the test button
emergency test, the device operates as briefly an operation test is initiated. During
non maintained. If you want to restore the this test period all indication LEDs are
previous condition (maintained operation), OFF.
press continuously the TEST button for 10
seconds, until the led strip lights. Release Automatic Operatioanal Test
the button and after a short emergency This test includes all the operations that
test, the device operates as maintained provide the manual test and is conducted
illumination sign. automatically every 15 days. In order to be
performed, the mains power supply and
Battery Charging the battery should be connected.
The battery charging is completely
controled. In this case, is achieved the Automatic Autonomous Test
perfect battery maintenance , as well as the The Automatic Autonomous Test is
elongation of its duration. When the battery conducted and measures the luminaire`s
has completely charged, it charges with a back up operation. This test is conducted
maintenance current. automatically every six months. In order to
Thank you for your trust in our products
Olympia Electronics - European manufacturer
Operation temperature range
Relative humidity
Construction materials
External panel's dimensions
External unit’s dimensions
Typical weight
Guarantee
Mains voltage
Maximum power consumption
Battery (Ni-MH)
Recharging time
Battery protection
Indications
Minimum emergency duration
Degrees of cover protection
Produced in accordance with
Light source intensity (230V) / (emerg.)