Omron E3JK User manual

E3JK
1E3JK
All voltage photoelectric sensors
E3JK
• Built-in amplifier accepts wide supply
voltage range.
• Slim, space-saving construction mea-
sures only 50 x 50 x 17.4 mm.
• Relay outputs with long life expectan-
cy and high switching capacity (3 A,
250 V AC).
• Polarized retroreflective type available
for glossy or shiny object detection.
* The value within the parentheses indicates the sensing distance applied when the E39-R2 reflector is used.
Note: The UL-listed model ends with "-US". (Example: E3JK-5M1-US). Note that the DC transistor type of the E3JK is UL-unlisted.
Accessories (Order Separately)
Slits
Reflectors
* Values in parentheses indicate the minimum required distance between the sensor and reflector.
Note: When the reflector used is other than the supplied one, set the sensing distance to about 0.7 times of the typical example as a guideline.
Sensor type Shape Connection
method Sensing distance Output form Output Model
Through-beam
Pre-wired
models
Light ON Relay output E3JK-5M1
Dark ON E3JK-5M2
Retroreflective
model (with
M.S.R. function)
*Light ON Relay output E3JK-R2M1
Dark ON E3JK-R2M2
Light ON/Dark ON
(selectable)
DC transistor
output
NPN E3JK-R2S3
PNP E3JK-R2R3
Retroreflective
model (without
M.S.R. function)
*Light ON Relay output E3JK-R4M1
Dark ON E3JK-R4M2
Light ON/Dark ON
(selectable)
DC transistor output
(NPN) E3JK-R4S3
Diffuse-reflective
Light ON Relay output E3JK-DS30M1
Dark ON E3JK-DS30M2
Light ON/Dark ON
(selectable)
DC transistor output
(NPN) E3JK-DS30S3
5m
2.5m
(3m)
4m
(5m)
300mm
Slit width Sensing distance Minimum sensing
object (typical) Model Quantity Remarks
Width 1 mmx20 mm E3JK-5
##
0.7 m 1 mm dia. E39-S39
1 pc. each for emitter
and receiver
(total 2 pcs.)
(Seal type long slit)
Can be used with the through-
beam model E3JK-5##.
Name Sensing distance (typical) Model Quantity Remarks
Reflectors
E3JK-R2## 2.5 m (rated value) E39-R1 1 Attached to the E3JK-R2##.
Attached to the E3JK-R4##.
E3JK-R4## 4 m (rated value)
E3JK-R2## 3 m E39-R2 1 ---
E3JK-R4## 5 m
Small reflector E3JK-R2## 1 m (5 mm) * E39-R3 1 ---
Tape Reflector
E3JK-R2##
750 mm (200 mm) *
E39-RS1
1 The M.S.R. function is available.E3JK-R2## 1.2 m (200 mm) * E39-RS2
E3JK-R2## 1.5 m (200 mm) * E39-RS3

2 Standard Photoelectric Sensors
Mounting Brackets
Note: If a through-beam model is used, order two Mounting Brackets for the emitter and receiver respectively.
Shape Model Quantity Remarks
E39-L40 1 Supplied with E3JK

3E3JK
E3JK
Rating/Performance
E3JK
Sensor
type
Through-
beam
Retroflective model
(with M.S.R. function)
Retroflective model
(without M.S.R. function) Diffuse-reflective
Item Model E3JK-5M#
E3JK-R2M
#E3JK-R2#3
E3JK-R4M
#E3JK-R4S3
E3JK-DS30M
#
E3JK-DS30S3
Sensing distance 5 m 2.5 m
(When using the E39-R1)
4 m
(When using the E39-R1)
300 mm
(White paper 100x100 mm)
Standard sensing
object
Opaque 14.8
dia. min. Opaque: 75 mm dia. min. ---
Differential
distance --- 20% max. of sensing
distance
Directional angle
Both emitter
and receiver:
3°C to 20°C
1° to 5° ---
Light source (wave
length)
Infrared LED
(950 nm) Red LED (660 nm) Infrared LED (950 nm)
Power supply volt-
age 12 to 240 VDC ±10% ripple (p-p) : 10% max. 24 to 240 VAC ±10% 50/60 Hz
Current
con-
sump-
tion
DC 3 W max. 2 W max.
AC 3 W max. 2 W max.
Control output
Relay
output:
250VAC
3 A (cosϕ=1)
max., 5 VDC
10 mA min.
Relay
output:
250VAC
3 A (cosϕ=1)
max., 5 VDC
10 mA min.
DC SSR Neg-
ative or posi-
tive common
48 VDC
100 mA max.
Leak current
0.1 mA max.
With load
short-circuit
protection
Relay
output:
250VAC
3 A (cosϕ=1)
max., 5 VDC
10 mA min.
DC SSR
Negative com-
mon
48 VDC
100 mA max.
Leak current
0.1 mA max.
With load short-
circuit protec-
tion
Relay
output:
250VAC
3 A (cosϕ=1)
max., 5 VDC
10 mA min.
DC SSR Neg-
ative common
48 VDC
100 mA max.
Leak current
0.1 mA max.
With load
short-circuit
protection
Life ex-
pectan-
cy (relay
output)
Me-
chanical 50 million times or more (switching frequency 18,000 times/hour)
Electri-
cal 100 thousand times or more (switching frequency 18,000 times/hour)
Response time 30 ms max. 30 ms max. 5 ms max. 30 ms max. 5 ms max. 30 ms max. 5 ms max.
Sensitivity
adjustment --- Single-turn adjustment
Ambient
illuminance Incandescent lamp: 3,000 lux max.
Ambient
temperature Operating: -25°C to 55°C, Storage: -30°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%RH, Storage: 35% to 95%RH (with no condensation)
Insulation
resistance 20 MΩmin. at 500 VDC
Dielectric strength 1,500 VAC at 50/60 Hz for 1 minute
Vibra-
tion
resis-
tance
Destruc-
tion 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Mal-
function 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

4E3JK
E3JK
Shock
resis-
tance
Destruc-
tion Destruction: 500 m/s2for 3 times each in X, Y, and Z directions
Mal-
function
Destruc-
tion:
100 m/s2
(approx.
10G)
3 times
each in
X, Y, and Z
directions
Destruction:
100 m/s2
(approx.
10G) 3 times
each in X, Y,
and Z direc
tions
Destruction:
500 m/s2for 3
times each in
X, Y and
Z directions
Destruction:
100 m/s2
(approx.
10G) 3 times
each in X, Y,
and Z direc
tions
Destruction:
500 m/s2for
3 times each
in X, Y, and
Z directions
Destruction:
100 m/s2
(approx.
10G) 3 times
each in X, Y,
and Z direc
tions
Destruction:
500 m/s2for
3 times each
in X, Y, and
Z directions
Protective
structure IEC60529 IP64
Connection
method Pre-wired models (standard length: 2 m)
Weight
(Packed state) Approx. 420 g Approx. 250 g
Material
Case ABS
Lens
Acrylics
Mounting
bracket
Steel
Accessories Mounting bracket (with screws), nuts, instruction manual, reflector (retroreflective model only)
Sensor
type
Through-
beam
Retroflective model
(with M.S.R. function)
Retroflective model
(without M.S.R. function) Diffuse-reflective
Item Model E3JK-5M#
E3JK-R2M
#E3JK-R2#3
E3JK-R4M
#E3JK-R4S3
E3JK-DS30M
#
E3JK-DS30S3

5E3JK
E3JK
Characteristic data (typical)
Excess Gain Ratio vs. Setting Distance
Through-beam model Retroreflective Models Diffuse-reflective
E3JK-5## E3JK-R2## + E39-R1 (supplied reflector) E3JK-DS30##
E3JK-R4## + E39-R1 (supplied reflector)
1,000
500
300
100
50
30
10
5
3
1
Setting distance (m)
102345678
Operating
voltage
Excess gain ratio
100
50
30
10
5
3
1
Settin
g
distance (m)
10234
Operating
voltage
Reflector: E39-R1
Excess gain ratio
Setting distance (mm)
1000 200 300 400 500
100
50
30
10
5
3
1
Operating
voltage
Sensing object: White paper
Excess gain ratio
Setting distance (m)
102345
100
50
30
10
5
3
1
Operating
voltage
Reflector: E39-R1
Excess gain ratio

6 Standard Photoelectric Sensors
Output Circuit Diagram
E3JK
Relay output
DC transistor output
Note: Connect to brown and blue on the emitter side.
Model Timing chart Output circuit
E3JK-5M1
E3JK-5M2
E3JK-R2M1
E3JK-R2M2
E3JK-R4M1
E3JK-R4M2
E3JK-DS30M1
E3JK-DS30M2
Model Timing chart Output circuit
E3JK-R2S3
E3JK-R4S3
E3JK-DS30S3
E3JK-R2R3
Light indicator
(red)
L-ON(Ta)
(E3JK-##M1)
D-ON(Ta)
(E3JK-##M2)
Incident
Interrupted
ON
OFF
ON
OFF
ON
OFF
Power
source
Main circuit
(Polarity Optional)
24 to 240 VAC
12 to 240 VDC
White
Brown
Blue
Black Contact output
Tc
Tb Ta
Gray
Built-in relay: G6C
Light
indicator
(red)
L-ON mode
D-ON mode
Incident
Interrupted
ON
OFF
ON
OFF
ON
OFF
Main
circuit
Power
source
Load
Load
Brown
Blue
White
Gray (D-ON)
Black (L-ON)
Drive
circuit
Drive
circuit
24 to 240 VAC
12 to 240 VDC
Light
indicator
(red)
L-ON mode
D-ON mode
Incident
Interrupted
ON
OFF
ON
OFF
ON
OFF
Power
source
(Polarity
Optional)
24 to 240 VAC
12 to 240 VDC
Main
circuit
Drive
circuit
Drive
circuit
D/ON
L/ON
Gray
Black
48 VDC max.
White
Load
Load
I1
I2
I1 + I2 < 100 mA
Brown
Blue
Note: The output stage leakage currents are 0.1 mA max., respectively.

7E3JK
E3JK
Operation
Adjustment
Precautions
Design
Power Reset Time
The Sensor is ready to detect an object within 200 ms after it
is turned ON. If Sensor and load are connected to separate
power supplies, ensure to turn ON the Sensor first.
Wiring Considerations
Connection/Wiring
If the DC transistor output type is used, the sum of load cur-
rents of L-ON output (NO) and D-ON output (NC) should be
within 100 mA. If the sum of load currents exceeds 100 mA,
the load short-circuit protection may be activated. (The load
short-circuit protection is reset by turning OFF the power of
the photoelectric sensor.)
Miscellaneous
Ambient Conditions (Installation Area)
The E3JK will malfunction if installed in the following places.
• Places where the E3JK is exposed to a dusty environment.
• Places where corrosive gases are produced.
• Places where the E3JK is directly exposed to water, oil, or
chemicals.
Item Through-beam Retroreflective Models Diffuse-reflective
Model
E3JK
Swing the receiver and emitter ver-
tically and/or horizontally and set
the adjuster in the center of the
range where the indicator of the re-
ceiver turns ON.
Like the through-beam model, ad-
just the reflector and emitter/re-
ceiver. Since the directional angle
of the emitter/receiver is 1 to 5°, ad-
just the emitter/receiver especially
carefully.
(1) If you have a sensing object as shown in the figure, turn the sensitivity
adjuster clockwise (increase the sensitivity) until the indicator is turned
ON, and define this adjuster position as (A).
(2) Remove the sensing object, turn the sensitivity adjuster clockwise until
the indicator is turned ON by a background object, and define this posi-
tion as (B).
(3) Turn the sensitivity adjuster counterclockwise (decrease the sensitivity)
from (B) until the indicator is turned OFF, and define this position as (C).
(4) The position in the middle of (A) and (C) is the optimum position. If the
indicator is not turned ON by the background object at the maximum
sensitivity, set the adjuster in the middle of (A) and maximum sensitivity.
The sensitivity adjuster may be damaged if an excessive force is applied.
Correct Use
With sensing object Without sensing object
Operation
Sensitivity
MIN MAX
Reset
Operation
(C)
(C)
(A) (A)
Setting
(B)
Background
object
Sensitivity
MIN MAX
(A)
Sensitivity
MIN MAX
E3JK
Emitter
Receiver
Emitter
Receiver

8 Standard Photoelectric Sensors
Dimensions (Unit: mm)
Sensors
Accessories (Order Separately)
Seal type long slit (for E3JK)
21
12
42
50
40
58
10
˚
R56.6
40
5
Optical
axis
36.5
21.5
Steel
13.4
28
50
Lens 14.8 dia.
Indicator *2
18
60
49 18
6 dia.
7
6.4
22
40 12
6.4
* 1.Mounting brackets can be used on the A side (Two, M4 x 20 attached) .
* 2.Emitter: Power indicator
Receiver: Light indicator
* 3.Emitter includes 2-conductor.
(A)*1
42
2-M6
6-dia., 5-conductor, vinyl-insulated
round cable (conductor cross-sectional
area: 0.3 mm
²
; insulation diameter: 1.5 mm).
Standard length: 2 m. * 3
E3JK-5##
Mounting Holes
With Mounting Bracket Attached
Emitter: E3JK-5L
Receiver: E3JK-5D##
21
12
Sensitivity adjustment
volume * 2
42
50
40
58
10˚
R56.6
40
5
Optical
axis
40
25
Steel
13.4
28
50
Lens
Light indicator
18
60
49 18
6 dia.
7
6.4
22
40 12
6.4
Emitter
Receiver
* 1. Mounting brackets can be used on the A side (Two, M4 x 20 attached) .
* 2. No sensitivity adjustment volume on the retororeflective model.
(A)*1
42
2-M6
6-dia., 5-conductor, vinyl-insulated round cable
(conductor cross-sectional area: 0.3 mm²; insulation diameter: 1.5 mm).
Standard length: 2 m. * 3
E3JK-R2##
E3JK-R4##
E3JK-DS30##
v
With Mounting Bracket Attached
Mounting Holes
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E027-E2-09A-X
E39-S39
Material: Polyester
0.1 mm thick
14
20 26.5
1±0.1
This manual suits for next models
12
Table of contents
Other Omron Accessories manuals

Omron
Omron ZFX-C-CD User manual

Omron
Omron E2A - User manual

Omron
Omron ZS Operating manual

Omron
Omron ZFX-SC50 User manual

Omron
Omron F160-2 - 2 User manual

Omron
Omron ZX2 Series User manual

Omron
Omron D6F-PH User manual

Omron
Omron FZ4 Series User manual

Omron
Omron E3X-DAC-S Series User manual

Omron
Omron ZW-7000 Series User manual

Omron
Omron F160 Vision Sensor User manual

Omron
Omron ZFV-SC90 Series User manual

Omron
Omron E3X-NL - User manual

Omron
Omron FJ Series User manual

Omron
Omron E2EC - User manual

Omron
Omron FQ-AC Series User manual

Omron
Omron ZX2-LDA41 User manual

Omron
Omron E3X-DA-S User manual

Omron
Omron D6FZ Series User manual

Omron
Omron E3NW-DS User manual