
E5ZE-8j-E E5ZE-8j-E
216
CHARACTERISTICS
Measurement precision Thermocouple:
(±0.3% of the measured value or ±2°C, whichever is larger) ±1 digit max.
(±0.3% of the measured value or ±3.6°F, whichever is larger) ±1 digit max.
Platinum resistance thermometer:
(±0.3% of the measured value or ±0.8°C, whichever is larger) ±1 digit max.
(±0.3% of the measured value or ±1.5°F, whichever is larger) ±1 digit max.
Adjustable sensitivity 0.0°C to 99.9°C or 0.0°F to 99.9°F (0.1°increments), valid for ON/OFF control only.
Cooling coefficient 0.0 to 10.0 (0.1 increments)
Proportional band 0.0°C to 999.9°C or 0.0°F to 999.9°F (0.1°increments)
Cooling: cooling coefficient ×proportional band
Integral time 0 to 3,999 s (1-s increments)
Derivative time 0 to 3,999 s (1-s increments)
Control cycle Heating or cooling: 1 to 99 s (1-s increments)
Sampling cycle Approx. 200 ms/8 control points
Dead band/overlap Band –999°to 999°(1°C or F increments)
Alarm set range With 1°increments: –999°to 9,999°(0°to 9,999°with upper/lower limit alarms)
With 0.1°increments: –999.9°to 9,999.9°(0.0°to 9,999.9°with upper/lower limit alarms)
Fuzzy logic strength 0 to 99% (1% increments)
Fuzzy logic scale 1 0.2°to 999.9°(0.1°C or F increments)
Fuzzy logic scale 2 0.02°to 99.99°(0.01°C or F increments)
SV protection Lithium battery backup
SV protection time 10 years min. at room temperature
Insulation resistance 20 MΩat 500 VDC between the FG terminal and analog input terminals
Dielectric strength Leakage current of 1 mA max. between the FG terminal and analog input terminals when 500 VAC
is applied for 1 min.
Vibration resistance Malfunction: 10 to 55 Hz with 15 m/s2(1G) for 10 minutes each in X, Y, and Z directions
Destruction: 10 to 55 Hz with 20 m/s2(2G) for 2 hours each in X, Y, and Z directions
Shock resistance Malfunction: 150 m/s2(15.3G) max. 3 times each in ±X, ±Y, and ±Z directions
Destruction: 200 m/s2(20.4G) max. 3 times each in ±X, ±Y, and ±Z directions
Enclosure rating IP00
Weight Enclosed Unit: 1,700 g max.
Open frame: 900 g max.
EMC Emission Enclosure EN55011 Group1 class A
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: ENV50140: 10 V/M amplitude modulated,
80 MHz to 1 GHz (level 3)
10 V/m (pulse modulated, 900 MHz)
Immunity conducted disturbance: ENV50141: 10 V (0.15 to 80 MHz) level 30)
Immunity burst: EN61000–4–4: 2 kV power line (level 3)
Approved standards Conforms to EN50081-2, EN50082-2 (See Note 3)
Note: 1. The measurement accuracy of the E5ZE used with a thermocouple B at 400°C or 750°F max. is not guaranteed. The following
measurement accuracy values are applied to the E5ZE.
K and T at –100°C max. and U: ±3°C ±1 digit max.
K and T at –100°F max. and U: ±5.4°F ±1 digit max.
R, S, and W at 200°C max., and B at 1,000°C max.: ±4°C ±1 digit max.
R, S, and W at 400°F max., and B at 1,800°F max.: ±7.2°F ±1 digit max.
2. The measurement accuracy of the E5ZE used with any thermocouple is 1°C/°F. The thermocouple can be used under the fol-
lowing temperature ranges to increase the measurement accuracy to as high as 0.1°C/°F.
K thermocouple: 0.0 °C to 1,300.0 °C, 0.0 °F to 2,300.0 °F
T or U thermocouple: 0.0 °C to 400.0 °C, 0.0 °F to 700.0 °F
N thermocouple: 400.0 °C to 1,300.0 °C, 700.0 °F to 2,300.0 °F
J, E, L, or PLII thermocouple: Any temperature
3. To ensure EMC conformance, refer to Wiring for Conformance to the EMC Directives at the end of this data sheet.