Optex SX-360Z User manual

SX-360Z, SX-360ZV
360° CEILING MOUNT PASSIVE INFRARED DETECTOR
INSTALLATION INSTRUCTIONS
-1--4-
360° CEILING MOUNT PASSIVE INFRARED DETECTOR
SX-360Z, SX-360ZV
INSTALLATION HINTS
1
DETECTION AREA
2
SPECIFICATIONS
12
FEATURES
Ceiling mount 360° PIR detector
Zoom area adjustment : ø18 m (ø60 ft.) at 2.4 –5.0 m (8 –16 ft.)
High density detection area with 276 zones
Selectable sensitivity (High, Medium or Low)
Selectable pulse count (TEST, 2 or 4)
Initial alarm memory (SX-360ZV)
LED remote control terminal
TOP VIEW SIDE VIEW
9.0
(30)
9.0
(30)
9.0
(30)
0
0
6.0
(20) 6.0
(20)
6.0
(20)
6.0
(20)
ZOOM
ZOOM “A” Position (See Section 7.)
Model SX-360Z
Detection method Passive Infrared
276 zones
Celling
ø18 m (ø60 ft.) at 2.4 –5 m (8 –16 ft.)
360° ZOOM
LED is blinking during warm-up period.
Alarm condition
2.0 ±0.5 sec.
N.C., 28 VDC 0.2 A (max.)
N.C., Opens when cover removed.
20 ±5 sec. 1, 2 or 4
Approx. 20 sec. (LED blinks.)
9.5 to 18 VDC
16 mA/(normal), 18 mA/(max.)
224 g (7.90 oz)
–20°C to +50°C (–4°F to +122°F)
95% (max.)
No Alarm 30 V/m
Detection zones
Mounting location
Coverage / Mounting
height
Optical design
LED indicator
Alarm period
Alarm output
Tamper switch
30 V DC 0.1 A (max.)
Tamper output
Pulse Count
Warm up period
Power input
Current draw
Weight
Operating
temperature
Environment humidity
RF interference
Dimensions
mm (inch) mm (inch)
67(2.64)
- 73(2.88)
45.5 (1.79)
46.5 (1.83)
6
(0.23)
20°
30°
12
(0.47)
ø128(ø5.04)
Mounting Position
Flush
wiring knockout
Pitch ø83.5 (ø3.29)
ø6.5 (ø0.26)
Wall tamper knockout
8.5 (0.33)
Mounting
holes
Flush wiring knockout
12
(0.47)
12
(0.47)
20°
Terminals
Surface wiring knockout
* Specifications and design are subject to change without prior notice.
ø8.5
(ø0.33)
4.5 (0.18)
Surface
wiring knockout
Flush
wiring space
Model SX-360ZV
Alarm memory Armed : 0 to 1 VDC. See section 8.
Initial Alarm memory Max.40 detectors See section 8.
Current draw 16 mA/(normal), 28 mA/(max)
Weight 227 g (8.00 oz.)
RF interference No Alarm 30 V/m
ZOOM
Unit: m (ft)
ZOOM “E” Position (See Section 7.)
ZOOM “C” Position (See Section 7.)
LED ON-OFF
10
The LED can be enabled or disabled by using the LED ON/OFF
switch or by using D.L. terminal.
1LED ON/OFF Switch (SX-360Z only)
2DL Terminal (for LED remote control)
TROUBLE SHOOTING AND MAINTENANCE
11
PROBLEM PROBABLE CAUSE REMEDY
LED does not light.
LED lights even
though no person
within area.
LED continues to
light
LED lights but signal
is not sent.
Correct supply voltage to
9.5 - 18 VDC.
Incorrect power supply voltage.
(disconnection, or low voltage)
See section 2 and section 7.
Switch positive and negative at
terminal.
Turn on the Switch. See section 10.
Remove object from detection
area.
Remove object from detection area.
Reconnect wire.
Must be 0 to 1 VDC. (grounded)
Check load of output. The unit
needs repair or replacement.
Wire correctly.
Incorrect detection area.
Incorrect polarity to detector.
LED switch is OFF
Moving object within area. (curtain,
wall hanging, etc.)
Rapid temperature changes (heater,
air-conditioner, etc.) within area.
Poor connection of alarm memory.
(SX-360ZV)
Wrong control voltage from panel.
(SX-360ZV)
Relay contact is stuck of damaged
due to overloading.
Faulty Wiring.
No.59-0527-8 150707
UL 59-0527-6 0908-31
EN
Avoid direct sunlight.
Avoid facing directly
to air conditioners or
heating vents.
Avoid vapor or high
humidity that can
cause condensation.
Install within 2.4 to 5.0 m (8.0 to 16 ft.)
height from floor.
2.4 to 5.0 m
(8.0 to 16 ft.)
Do not install outdoors.
Do not obscure partially or
completely the detector’s
field of view.
14
5
3
67
Avoid moving objects in the
detection area.
2
This symbol indicates
prohibition.
This symbol indicates
recommendation.
2.4(8.0)
4.2(14)
4.8(15)
3.6(12)
3.0(10)
2.4(8.0)
3.0(10)6.0(20)9.0(30) 3.0(10) 6.0(20) 9.0(30)
0
3.6(12)
3.0(10)
2.4(8.0)
3.0(10)6.0(20)9.0(30) 3.0(10) 6.0(20) 9.0(30)
0
3.0(10)6.0(20)9.0(30) 3.0(10) 6.0(20) 9.0(30)
0
• Use this switch to enable or disable LED.
• This switch has priority to over DL terminal.
• LED can be enabled or disabled remotely by using
DL terminal.
LED Enabled Connect DL terminal to common ground.
Open DL terminal circuit.
Remote operation
LED Disabled
Note>>
• LED operation does not affect the alarm memory functions.
• DL terminal common line is same as terminal of POWER INPUT.
COMPLIANCE
13 • This unit is designed to detect movement of an intruder and activate an
alarm control panel. Being only a part of a complete system, we cannot
accept responsibility for any damages or other consequences resulting
from an intrusion.
• This Product conforms to the EMC Directive. 2004/108/EC.
• The ULC products are installed in accordance with the Canadian Code
as per Section 4.3 of ULC-S306.
EMC Directive
2004/108/EC
EN 50130-4: 2011
EN 55022: 2010
(SX-360Z)
EN50131-1 Grades and Environmental Class:
Security Grade 2 and Environmental Class II.
EN 50131-2-2
Tested and certified by Telefication.
larm klass 2, miljö klass II, SSF 1014 v4
UL/c-UL Listed
PD6662:2010
Note>>
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net/
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com/
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec/
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optexeurope.com/
OPTEX SECURITY SAS (France)
URL: http://www.optex-security.com/
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.com.pl/
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com/
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com/
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex.net/in/en/sec/
OPTEX TECHNOLOGIES B.V.
(The Netherlands)
URL: http://www.optex.eu/
-3-
-2-
PARTS IDENTIFICATION
3
INSTALLATION METHOD
4
WIRING
5
SENSITIVITY ADJUSTMENT
6
ZOOM AREA ADJUSTMENT
7
INITIAL ALARM MEMORY & ALARM MEMORY (SX-360ZV)
8
PULSE COUNT ADJUSTMENT
9
SX-360Z SX-360ZV
Main unit
Zoom unit Screw
Pulse count selector
(See section 9.)
LED ON/OFF switch
(See section 10.)
Sensitivity selector
(See section 6.)
Wiring knockout
Wiring knockout
Wiring knockout
LED indicator
Pyro sensor
Do not touch.
Terminals
Wiring knockout
Screw
Mounting holes
Pitch 83.5 mm
(3.28 inch)
LED indicator for
Zoom ring
Zoom lens
SPARE TAMPER
D.L. (See section 10.)
N.C.
TAMPER
D.L. (See section 10.)
(See section 8.)
(See section 8.)
N.C.
ALARM OUTPUT ALARM MEMORY
ALARM OUTPUT
POWER INPUT
INITIAL ALARM MEMORY
SPARE Two spare terminals
are electrically
connected on the
circuit board.
SPARE
POWER INPUT
Warm-up period
Alarm
Alarm memory
Initial alarm memory
Remove the Zoom-unit from
the Main unit by loosening
the screw and turning the
Zoom unit counter-clockwise.
Before making adjustments, determine the mounting
height and detection area. (See section 7.)
Select the sensitivity “H (High)”, “M (Medium)” or “L (Low)”.
The following chart shows recommended setting for diameter
of detection area.
SENS. L
ø9.0 to ø12 m
(ø30 to ø40 ft.)
ø12 to ø15 m
(ø40 to ø50 ft.)
ø15 to ø18 m
(ø50 to ø60 ft.)
MH
DIAMETER OF
DETECTION AREA
Note>>
• When the warm-up period is expired, alarm is generated once. This is an electric characteristic of SX-360Z and not a mal-function.
• Conduct a walk test at least once a year.
Mount the Main unit
and wire according to
section 5.
Full up the mounting
holes with the sponge.
Adjust Zoom (section
7) and Sensitivity (section
6) according to the
required installation
height.
Install the Zoom unit
by turning it clockwise.
And supply power to
the detector.
When LED stops blinking,
the warm-up period is
expired (approx. 20 sec.). Conduct a walk test.
Select pulse count (see
section 9.) according to
your coverage needs and
environmental conditions.
And then fasten the screw.
Power wires should not exceed the following lengths.
VOLTAGE
WIRE SIZE
AWG22 (0.33 mm2)
12V
SX-360Z SX-360ZV
14V 12V 14V
320 m (1070 ft) 650 m (2140 ft) 230 m (770 ft) 460 m (1530 ft)
730 m (2400 ft)
1150 m (3800 ft)
360 m (1200 ft)
570 m (1900 ft)
1020 m (3400 ft)
1600 m (5300 ft)
510 m (1700 ft)
820 m (2700 ft)
AWG20 (0.52 mm2)
AWG18 (0.83 mm2)
UL requires SX-360Z to be connected to a UL listed power supply capable of providing a nominal input of 12 VDC and battery standby time of 4 hours.
When using two or more units on one wire, the maximum length is obtained by dividing the above length by the number of units used.
2.4 to 5.0 m
(8.0 to 16 ft.)
ø9.0 to ø18 m
(ø30 to ø60 ft.)
1
1 2
2 3
1
1
3
2 3
4 5 6
Zoom ring
Turn Zoom ring for adjustment.
Zoom lens
Loosen the black Zoom Lock screw.
For higher installations, turn counter-clockwise.
Fasten the black Zoom lock screw at the
marked point of the required installation
height.
For lower installations, turn clockwise.
The SX-360Z series detection pattern can be adjusted for installations at any height, between 2.4 to 5.0 m (8.0 to 16 ft.)
DETECTION AREA CHART
ADJUSTING THE ZOOM UNIT
Unit: m (ft.)
The SX-360ZV can indicate an alarm history during armed period by wiring ALARM MEMORY terminal (A.M.) shown in the following section.
It indicates on the LED after the system is disarmed. In case that several detectors are connected in one loop, it can indicate which one detected
intrusions. In addition, by wiring INITIAL ALARM MEMORY terminal (I.A.), detectors can indicate which one detected intrusion first.
System status 2Reset
Wiring and LED indications
Adjust pulse count as follows.
System armed
Control panel outputStatus
0 - 1 VDC (grounded)
Open
System disarmed
“grounded”= A.M. terminal is electrically connected with power
supply terminal (ground).
Instant alarm mode
Select this position for walk test only.
Factory default position
Select this position for most applications.
For bad environments, changing
temperatures etc.
Alarm memories are reset automatically when the system is armed again.
A
MOUNTING HEIGHT
ZOOM-LOCK SCREW
5.0 m (16 ft.)
4.3 m (14 ft.)
3.7 m (12 ft.)
ø9.0 (ø30)
3.0 m (10 ft.)
2.4 m (8.0 ft.)
ø18 (ø60)
ø16 (ø52)
ø14 (ø48)
ø11 (ø37)
B
ø10 (ø34)
-
ø18 (ø60)
ø15 (ø50)
ø12 (ø40)
C
ø12
D
ø15
E
ø18
-
-
-
-
-
-
-
ø18
-
-
ø18
ø15
I.A. A.M. I.A. A.M. I.A. A.M.
Note>>
• Up to 40 detectors can be connected in one loop
for initial alarm memory.
Control
Panel
I.A. A.M. I.A. A.M. I.A. A.M.
Note>>
• Do not fasten the screw too tightly.
Note>>
• A suitable control panel is required for alarm memory.
• Alarm memory is operated whether the LED is disabled or not.
• Alarm memory is not latched while system is disarmed.
• LED operation and alarm output are not affected by the status of alarm
memory function while system is armed.
A.M.
A.M.
I.A.
Disarmed
11
2
3
No. LED
OFF
Blinking
Lighting
23
Initial alarm memory is shown by a blinking LED. Other memories
(from the second detection on) are shown by a lighting LED.
All alarm memories are shown by blinking LED.
LED indicationsWiringFunction
Alarm
memory
Initial alarm
memory
1
2
3
No. LED
OFF
Blinking
Blinking
Control
Panel Disarmed
123
PULSE COUNT TEST 2 4
USAGE
The detector recognizes whether the system is armed or
disarmed by detecting the voltage of control panel output
through the A.M. terminal.
Control
Panel
Control
Panel
Main unit

This manual suits for next models

1

Other Optex Security Sensor manuals

Optex AX-70TN User manual

Optex

Optex AX-70TN User manual

Optex WX Shield Series User manual

Optex

Optex WX Shield Series User manual

Optex AX-100TFR Series User manual

Optex

Optex AX-100TFR Series User manual

Optex HX-80NRAM User manual

Optex

Optex HX-80NRAM User manual

Optex RXC-DT-X5 User manual

Optex

Optex RXC-DT-X5 User manual

Optex Smart Line Series User manual

Optex

Optex Smart Line Series User manual

Optex FitLink User manual

Optex

Optex FitLink User manual

Optex Boundary Gard BX-80NR User manual

Optex

Optex Boundary Gard BX-80NR User manual

Optex HX-40 User manual

Optex

Optex HX-40 User manual

Optex AX-70TN User manual

Optex

Optex AX-70TN User manual

Optex Boundary Gard BX-80N Manual

Optex

Optex Boundary Gard BX-80N Manual

Optex PROWAVE AIR-SLIDE 2 User manual

Optex

Optex PROWAVE AIR-SLIDE 2 User manual

Optex InSight INS-QXI-ST User manual

Optex

Optex InSight INS-QXI-ST User manual

Optex OVS-50TNR User manual

Optex

Optex OVS-50TNR User manual

Optex inSight INS-HX-80N User manual

Optex

Optex inSight INS-HX-80N User manual

Optex HX-40 User manual

Optex

Optex HX-40 User manual

Optex OVS-01CC User manual

Optex

Optex OVS-01CC User manual

Optex HX-40/40AM Quick start guide

Optex

Optex HX-40/40AM Quick start guide

Optex RXC-RST User manual

Optex

Optex RXC-RST User manual

Optex CDX-AM Quick start guide

Optex

Optex CDX-AM Quick start guide

Optex SL-100 TNR User manual

Optex

Optex SL-100 TNR User manual

Optex VX-402R User manual

Optex

Optex VX-402R User manual

Optex CX-702S User manual

Optex

Optex CX-702S User manual

Optex REDSCAN Series User manual

Optex

Optex REDSCAN Series User manual

Popular Security Sensor manuals by other brands

Honeywell 5800FLOOD installation instructions

Honeywell

Honeywell 5800FLOOD installation instructions

Inovonics EE1260 EchoStream Installation and operation manual

Inovonics

Inovonics EE1260 EchoStream Installation and operation manual

Meggitt vibro-meter SpeedSys300 ODS301 user manual

Meggitt

Meggitt vibro-meter SpeedSys300 ODS301 user manual

Pilz PSEN 2.2p-21 operating manual

Pilz

Pilz PSEN 2.2p-21 operating manual

Rosslare PYR-3011 H/G installation instructions

Rosslare

Rosslare PYR-3011 H/G installation instructions

mothercare wood effect corner cushions user guide

mothercare

mothercare wood effect corner cushions user guide

Pentatech CO30 Operating instructions and safety instructions

Pentatech

Pentatech CO30 Operating instructions and safety instructions

SENSIT Technologies SENSIT TKX instruction manual

SENSIT Technologies

SENSIT Technologies SENSIT TKX instruction manual

Teletek electronics SensoIRIS S130 installation instructions

Teletek electronics

Teletek electronics SensoIRIS S130 installation instructions

Karat AC Installation and operation manual

Karat

Karat AC Installation and operation manual

SCE SE230K quick start guide

SCE

SCE SE230K quick start guide

LED Group Robus Proton instruction manual

LED Group

LED Group Robus Proton instruction manual

LEGRAND CP Electronics Casambi EBDMR-CB-DD installation guide

LEGRAND

LEGRAND CP Electronics Casambi EBDMR-CB-DD installation guide

SILENTRON 5414 instruction manual

SILENTRON

SILENTRON 5414 instruction manual

e2v CCD42-90 manual

e2v

e2v CCD42-90 manual

Risco WL T6S installation instructions

Risco

Risco WL T6S installation instructions

Denios GS 155 operating manual

Denios

Denios GS 155 operating manual

MSA Orion G operating manual

MSA

MSA Orion G operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.