Quick Installation Guide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
The is a managed industrial Ethernet switch
with sixteen 10/100/1000Base-T(X) ports and eight 100/1000Base-X SFP
ports. With two sets of bypass ports (the optical ports) that ensure constant
network connectivity if power outage or node failure occurs, the traffic will
bypass the inactive switch and continue to transfer to the next active
switch. The switch supports Ethernet Redundancy protocols, O-Ring
(recovery time <30ms over 250units of connection) and MSTP
(RSTP/STP compatible) to protect mission-critical applications from
network interruptions or temporary malfunctions with fast recovery
technology. With a wide operating temperature from -40 C to 70 C, the
device can be managed centrally via ORing’s proprietary Open-Vision
platform as well as via Web-based interfaces, Telnet, and console (CLI).
The switch is one of the most reliable choices for highly-managed and
fiber Ethernet applications.
DGS-9168GP-AIO_S series
oo
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Safety & Warnings
Dimension
Panel Layouts
1. Fiber bypass ports
2. Reset button
3. Power LED
4. PWR1 LED
5. PWR2 LED
6. Ring master LED
7. Ring status LED
8. Fault indicator
9. Console port
10. 100/1000 Base-X fiber port
11. LNK/ACT LED for fiber port
12. 10/100/1000 Base-T(X) LAN port
13. LNK/ACT LED for LAN port
14. Speed LED for LAN port
Package Contents
Contents
CD
DGS-9168GP-AIO_S
Pictures Number
X1
X1
Front Panel
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
QIG
Console Cable X1
X1
1
Network Connection
QIG DGS-9168GP-AIO_S 1907-2-29-DGS9168GPAIO-1.0
The switch provides standard Ethernet ports. According to the link type, the switch uses CAT 3,
4, 5,5e UTP cables to connect to any other network devices (PCs, servers, switches, routers, or
hubs). Please refer to the following table for cable specifications.
Industrial Desktop Managed Gigabit
Switch
SWITCH
INDUSTRIAL
Desktop
DGS-9168GP-AIO_S
Network
B
Monitor
A
TX RX
B
TX RX TX RX
A
TX RX
PWR1
PWR
Console
Reset
11520bps,
8,N, 1
PWR2 Ring
R.M Fault
G2
G1
G4
G3
10/100/1000T
G6
G5
G8
G7
G22
G23
G20 G21 G18
G19
G20 G17
100/1000X
DGS-9168GP-AIO_S
165.00
300.00
88.00
24.00
20.75
63.60
14.70
3.00
3.70
AC100-240V
50-60HZ
Relay
2 34567 8 9 10 11
12 13 14
Rear Panel
12
1. Power socket of power input for
AC 100V~240V / 50~60Hz
2. Relay output to carry capacity of
1A at 24VDC
Cable Types and Specifications:
Cable Type Ma x. Length Connector
10BASE-T Cat. 3, 4, 5 1 00-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5/Cat. 5e 100-ohm UTP UTP 1 00 m (328ft) RJ-45
10/100 B ase- T(X) MDI/MDI -X
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+( receive)
2 TD-(transmi t) RD-(receive)
3RD+(receive)TD+(transmit)
4NotusedNotused
5NotusedNotused
6RD-(receive)TD-(transmit)
7NotusedNotused
8NotusedNotused
1000Base-T MDI/MDI -X
Pin Number MDI port MDI-Xport
1BI_DA+BI_DB+
2BI_DA-BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6BI_DB-BI_DA-
7 BI_ DD+ BI_DC+
8 BI_DD- BI_DC-
1000Base-T RJ-45 Port
Pin Number Assignment
1BI_DA+
2BI_DA-
3BI_DB+
4BI_DC+
5 BI_DC-
6BI_DB-
7BI_DD+
8 BI_DD-
10/10 0 Base- T(X) RJ-45 Port
Pin Number Assignments
1TD+
2TD-
3 RD+
4 Not used
5 Not used
6RD-
7 Not used
8 Not used
For pin assignments for different types of cables, please refer to the following tables.
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
To connect the console port to an external management device, you need an RJ-45 to DB-9
cable, which is also supplied in the package. Below is the console port pin assignment
information.
Console Port Pin Definition
The device provides two sets of bypass fiber ports, giving the SFP fiber ports
additional redundancy capabilities. Connect a LC fiber cable from a fiber port to a
monitor port on the front panel and another LC fiber cable from the corresponding network
port to another switch. When the switch breaks down, incoming traffic will travel through the
bypass module and onto another active switch connected to the network port.
optical
Optical Bypass Connection
The fiber port will still work if it is not connected to any monitor port. However, the
fiber port will not have bypass ability when the device is down.
G10
G9
G12
G11
G14
G13
G16
G15
Network
B
Monitor
A
TX RX
B
TX RX TX RX
A
TX RX
PWR1
PWR
Console
Reset
11520bps,
8,N, 1
PWR2 Ring
R.M Fault
G2
G1
G4
G3
10/100/1000T
G6
G5
G8
G7
G22
G23
G20 G21 G18
G19
G20 G17
100/1000X
DGS-9168GP-AIO_S
G10
G9
G12
G11
G14
G13
G16
G15
Network
B
Monitor
A
TX RX
B
TX RX TX RX
A
TX RX
PWR1
PWR
Console
Reset
11520bps,
8,N, 1
PWR2 Ring
R.M Fault
G2
G1
G4
G3
10/100/1000T
G6
G5
G8
G7
G22
G23
G20 G21 G18
G19
G20 G17
100/1000X
DGS-9168GP-AIO_S
G10
G9
G12
G11
G14
G13
G16
G15
Power Cable X1
Elevated Operating Ambient:
Reduced Air Flow:
Mechanical Loading:
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven mechanical
loading.
AC100-240V
50-60HZ
Relay
QIG Quick Installation Guide
PRINTED ON RECYCLED PAPER
Version 1.0
Quick Installation Guide
Configurations
After installing the switch, the green power LED should turn on. Please refer to
the following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP
address is 192.168.10.1
2. Log in with default user name and password
(both are ). After logging in, you
should see the following screen. For more
information on configurations, please refer to
the user manual. For information on operating
the switch using ORing’s Open-Vision
management utility, please go to ORing
website.
admin
Follow the steps to set up the switch:
Power
Redundant Input power
Power consumption(Typ.)
Dual 100~240V AC power inputs in single power socket
25 Watts
Overload current protection Present
Physical Characteristic
Enclosure IP-30
Dimension(WxDxH) 300(W)x165(D)x88(H)mm(11.8x6.49x3.46inch)
RS-232 Serial Console Port
Switch Properties
Switch latency: 7 us
Switch bandwidth: 48Gbps
Max. Number of Available VLANs: 256
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
Https / SSH enhance network security
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Software Features
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCPServer/Clientsupport
SMTP Client
Modbus TCP
Network Redundancy O-Ring, Open-Ring, O-chain, MRP, Fast Recovery, MSTP (RSTP/STP compatible)
RS-232 in RJ45 connector with console cable. Baud rate setting: 115200bps, 8, N, 1
Weig ht (g ) 2326 g
Weig ht (g ) 710 g 740 g722 g 735 g 735 g 740 g
Environmental
-40to85C(-40to185F)
oo
Storage Temperature
-40to70C(-40to158F)
oo
Operating Temperature
5% to 95% Non-condensingOperating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class AEMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27Shock
IEC60068-2-32
IEC60068-2-6Vibration
EN60950-1
Safety
Free Fall
Warranty
5years
Specifications
ORing Switch Model DGS-9168GP-SS-AIO_S
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3z for 1000Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.3x for Flow control,
IEEE 802.1p for COS (Class of service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
10/100/1000Base-T(X) Ports
in RJ45 Auto MDI/MDIX
MAC Table 8K
Priority Queues 8
Processing Store-and-Forward
16
100/1000Base-X with SFP port 8
QIGQIG DGS-9168GP-AIO_S
Industrial Desktop Managed Gigabit
Switch
SWITCH
INDUSTRIAL
Desktop
DGS-9168GP-AIO_S
DGS-9168GP-MM-AIO_S
Wiring
The relay contacts of the 2-pin terminal block connector are used to
detect user-configured events. The two wires attached to the fault
contacts form a close circuit when a user-configured event is
triggered. If a user-configured event does not occur, the fault circuit
remains opened.
Power inputs
Fault Relay
Relay
For power supply, simply insert the AC power cable to the power
connector at the back of the switch and turn on the power switch. The
input voltage is 100V~240V / 50~60Hz
AC Power Connection
Resetting
To reboot the switch, press the button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the button for 5
seconds.
Reset
Reset
LC Bypass Port Type Single-Mode Multi-Mode
Fault Contact
Relay Relayoutputtocarrycapacityof1Aat24VDC
ORing Industrial Networking Corp.
Copyright© 2014 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
Buffer Size 4Mbit
Jumbo Frame 9.6K Bytes
LED Color Sta tus Description
System LED indicators
PWR Green On System is on and power supplies are
functioning properly.
PW1 Green On Power module 1 activated
PW2 Green On Power module 2 activated
R.M Green On System is o perating in O-Ring Master mode
Ring Green On Rin g enabled
Faul t Amb er O n Faults oc cur
10/100/ 1000Base-T (X) Gigabit Eth ernet ports
On Port is connected an d running
LNK/ACT Green
Off Port is disco nnected
Green O n Port is runni ng at 1 000Mbps
Amber On Port is running at 100MbpsSpeed
Off Port is runni ng at 10Mbps
100/100 0Base-X SFP Ports
On Port is linked
LNK/ACT Green
Blinki ng Transmitting data
PC (male) pin assignment RS-232 with DB9 (female) pin
assig nmen t (RJ45-DB9 cable) RJ45 pin assignment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5 GND PIN#5 GND PIN#5 GND

This manual suits for next models

1

Other ORiNG Switch manuals

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG IPS-1080A User manual

ORiNG

ORiNG IPS-1080A User manual

ORiNG IPS-1042FA-MM-SC User manual

ORiNG

ORiNG IPS-1042FA-MM-SC User manual

ORiNG IGPS-1411GTPA User manual

ORiNG

ORiNG IGPS-1411GTPA User manual

ORiNG TGPS-9084GT-M12 User manual

ORiNG

ORiNG TGPS-9084GT-M12 User manual

ORiNG IGS-1042GPA User manual

ORiNG

ORiNG IGS-1042GPA User manual

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG RES-3242GC User manual

ORiNG

ORiNG RES-3242GC User manual

ORiNG IES-2050A User manual

ORiNG

ORiNG IES-2050A User manual

ORiNG IPS-2042TX Series User manual

ORiNG

ORiNG IPS-2042TX Series User manual

ORiNG TGPS-9084GT-M12X-BP2-24V User manual

ORiNG

ORiNG TGPS-9084GT-M12X-BP2-24V User manual

ORiNG EN50155 User manual

ORiNG

ORiNG EN50155 User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG IES-3162GC Series User manual

ORiNG

ORiNG IES-3162GC Series User manual

ORiNG IGS-3044GC User manual

ORiNG

ORiNG IGS-3044GC User manual

ORiNG IGPS-9084GP User manual

ORiNG

ORiNG IGPS-9084GP User manual

ORiNG IES-180-L User manual

ORiNG

ORiNG IES-180-L User manual

ORiNG IGPS-1080-24V User manual

ORiNG

ORiNG IGPS-1080-24V User manual

ORiNG IES-2050-M12 User manual

ORiNG

ORiNG IES-2050-M12 User manual

ORiNG IES-1080A User manual

ORiNG

ORiNG IES-1080A User manual

ORiNG IDS-342GT User manual

ORiNG

ORiNG IDS-342GT User manual

ORiNG TGS-1080-M12 Series User manual

ORiNG

ORiNG TGS-1080-M12 Series User manual

ORiNG IGPS-1080A User manual

ORiNG

ORiNG IGPS-1080A User manual

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3882GT-M12-BP1 User manual

Popular Switch manuals by other brands

HP FlexFabric 12900 series Configuration guide

HP

HP FlexFabric 12900 series Configuration guide

Delta Electronics Agema Series installation guide

Delta Electronics

Delta Electronics Agema Series installation guide

Attwood 69260 installation instructions

Attwood

Attwood 69260 installation instructions

XUNZEL Hub D50 Home quick start guide

XUNZEL

XUNZEL Hub D50 Home quick start guide

Exsys EX-1177HMVS-WT manual

Exsys

Exsys EX-1177HMVS-WT manual

H3C S7508E-X Installation, quick start

H3C

H3C S7508E-X Installation, quick start

EtherWAN EX45900 series quick start guide

EtherWAN

EtherWAN EX45900 series quick start guide

Techlogix TL-SMP-HDV user manual

Techlogix

Techlogix TL-SMP-HDV user manual

nedis RFPS110WT quick start guide

nedis

nedis RFPS110WT quick start guide

Link electronics 862-XL818HD/2A Specification sheet

Link electronics

Link electronics 862-XL818HD/2A Specification sheet

AMX Multi Preview Operation/reference guide

AMX

AMX Multi Preview Operation/reference guide

Pickering 40-792 user manual

Pickering

Pickering 40-792 user manual

DVIGear DVI-3580a quick start guide

DVIGear

DVIGear DVI-3580a quick start guide

Juniper EX Series Connecting

Juniper

Juniper EX Series Connecting

Spirax Sarco LSB31 Installation and maintenance instructions

Spirax Sarco

Spirax Sarco LSB31 Installation and maintenance instructions

SIIG US22 Series Quick installation guide

SIIG

SIIG US22 Series Quick installation guide

TRENDnet TK-801R datasheet

TRENDnet

TRENDnet TK-801R datasheet

CAMBRIONIX PowerPad8S user manual

CAMBRIONIX

CAMBRIONIX PowerPad8S user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.