Pepperl+Fuchs ML100-55-G/95/102 User manual

alle Maße in mm
Dimensions
Abmessungen
Technische Daten
Technical data
Elektrischer Anschluss
Electrical connection
Adressen/Addresses
Sicherheitshinweise:
• Vor der Inbetriebnahme Betriebsanleitung lesen
• Anschluss, Montage und Einstellung nur durch Fachpersonal
• Kein Sicherheitsbauteil gemäß E -Maschinenrichtlinie
Security Instructions:
• Read the operating instructions before attempting commissioning
• Installation, connection and adjustments should only be undertaken by specialist personnel
• Not a safety component in accordance with the E Machinery Directive
all dimensions in mm
www.pepperl-fuchs.com
Pepperl+Fuchs Group
68301 Mannheim · Germany
Tel. +49 621 776-4411
Fax +49 621 776-27-4411
E-mail: fa-info@de.pepperl-fuchs.com
Worldwide Headquarters
Pepperl+Fuchs Group · Mannheim · Germany
E-mail: fa-info@de.pepperl-fuchs.com
USA Headquarters
Pepperl+Fuchs Inc. · Twinsburg · USA
E-mail: fa-info@us.pepperl-fuchs.com
Asia Pacific Headquarters
Pepperl+Fuchs Pte Ltd · Singapore
E-mail: [email protected].com
Company Registration No. 199003130E
Sender
Empfänger
11 3
20
10.6
M8 x 1
10.6
4.1
2.8
25.4
31
34.2
12.18.7
M3
Reflexionslichtschranke f r Glaserkennung
M8-Stecker, 4-polig
Retroreflective sensor for glass detection
M8 connector, 4-pin
ML100-55-G/95/102
Allgemeine Daten
Betriebsreichweite 0 ... 2,5 m
Reflektorabstand 0,05 ... 2,5 m
Grenzreichweite 2,5 m
Referenzobjekt Reflektor H50
Lichtsender LED
Lichtart rot, Wechsellicht
Polarisationsfilter ja
Lichtfleckdurchmesser ca. 180 mm im Abstand von 2,5 m
Öffnungswinkel ca. 4 °
Lichtaustritt frontal
Fremdlichtgrenze EN 60947-5-2:2007+A1:2012
Kenndaten funktionale Sicherheit
MTTFd 860 a
Gebrauchsdauer (TM) 20 a
Diagnosedeckungsgrad (DC) 0 %
Anzeigen/Bedienelemente
Betriebsanzeige LED grün: Netz ein (Power on) Teach-In : LEDs gelb/grün; gleichphasiges Blinken; 2,5 Hz Teach
Fehler: LEDs gelb/grün; gegenphasiges Blinken; 8,0 Hz
Funktionsanzeige LED gelb: leuchtet bei Empfang des Sendestrahls aus bei Strahlunterbrechung
Bedienelemente Teach-In Drehschalter
Bedienelemente Hell-/Dunkelumschalter voreingestellt zu hellschaltend
Kontrasterkennungsstufen 18 % - Klarglasflaschen
40 % - Farbglas oder nichttransparente Materialien
einstellbar durch Teach-In-Schalter
Elektrische Daten
Betriebsspannung B10 ... 30 V DC
Welligkeit max. 10 %
Leerlaufstrom I0< 20 mA
Ausgang
Schaltungsart Die Schaltungsart des Sensors ist umschaltbar. Der Auslieferungszustand ist: hellschaltend
Signalausgang 1 NPN-Ausgang, kurzschlussfest, verpolsicher, offener Kollektor
Schaltspannung max. 30 V DC
Schaltstrom max. 100 mA , ohmsche Last
Spannungsfall d
≤
1,5 V DC
Schaltfrequenz f 1000 Hz
Ansprechzeit 0,5 ms
Umgebungsbedingungen
mgebungstemperatur -30 ... 60 °C (-22 ... 140 °F)
Lagertemperatur -40 ... 70 °C (-40 ... 158 °F)
Mechanische Daten
Gehäusebreite 11 mm
Gehäusehöhe 31 mm
Gehäusetiefe 20 mm
Schutzart IP67
Anschluss Steckverbinder M8 x 1 , 4-polig
Material
Gehäuse PC (Polycarbonat)
Lichtaustritt PMMA
Masse ca. 10 g
Anzugsmoment Befestigungsschrauben 0,6 Nm
Normen- und Richtlinienkonformität
Richtlinienkonformität
EMV-Richtlinie 2004/108/EG EN 60947-5-2:2007+A1:2012
Normenkonformität
Normen L 60947-5-2
Zulassungen und Zertifikate
L-Zulassung c Lus Listed, Class-2-Stromquelle oder L-gelistetes Netzteil mit beschränktem Spannungsaus-
gang mit (evtl. integrierter) Sicherung (max. 3.3 A gemäß L248), Typ-1-Gehäuse
CCC-Zulassung Produkte, deren max. Betriebsspannung
≤
36 V ist, sind nicht zulassungspflichtig und daher nicht
mit einer CCC-Kennzeichnung versehen.
Emitter
Receiver
11 3
20
10.6
M8 x 1
10.6
4.1
2.8
25.4
31
34.2
12.18.7
M3
04/24/2020
Date DIN A3 ->
Option:
2
1
3
4
+UB
Q
0 V
n.c.
102
1 3
2 4
Option:
2
1
3
4
+UB
Q
0 V
n.c.
102
General specifications
Effective detection range 0 ... 2.5 m
Reflector distance 0.05 ... 2.5 m
Threshold detection range 2.5 m
Reference target H50 reflector
Light source LED
Light type modulated visible red light
Polarization filter yes
Diameter of the light spot approx. 180 mm at a distance of 2.5 m
Angle of divergence approx. 4 °
Optical face frontal
Ambient light limit EN 60947-5-2:2007+A1:2012
Functional safety related parameters
MTTFd 860 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green: power on Teach-In : LED yellow/green; equiphase flashing; 2,5 Hz Teach Error:LED
green/yellow non equiphase flashing; 8.0 Hz
Function indicator LED yellow: lights up when receiving the light beam OFF when light beam is interrupted
Control elements Teach-In rotary switch
Control elements Light-on/dark-on changeover switch preset to light on
Contrast detection levels 18 % - clear glass bottles
40 % - colored glass or opaque materials
adjustable due to Teach-In switch
Electrical specifications
Operating voltage B10 ... 30 V DC
Ripple max. 10 %
No-load supply current I0< 20 mA
Output
Switching type The switching type of the sensor is adjustable. The default setting is: light on
Signal output 1 NPN output, short-circuit protected, reverse polarity protected, open collector
Switching voltage max. 30 V DC
Switching current max. 100 mA , resistive load
Voltage drop d
≤
1.5 V DC
Switching frequency f 1000 Hz
Response time 0.5 ms
Ambient conditions
Ambient temperature -30 ... 60 °C (-22 ... 140 °F)
Storage temperature -40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Housing width 11 mm
Housing height 31 mm
Housing depth 20 mm
Degree of protection IP67
Connection Connector M8 x 1 , 4-pin
Material
Housing PC (Polycarbonate)
Optical face PMMA
Mass approx. 10 g
Tightening torque, fastening screws 0.6 Nm
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/EC EN 60947-5-2:2007+A1:2012
Standard conformity
Standards L 60947-5-2
Approvals and certificates
L approval c Lus Listed, Class 2 Power Source or listed Power Supply with a limited voltage output with
(maybe integrated) fuse (max. 3.3 A according L248), Type 1 enclosure
CCC approval CCC approval / marking not required for products rated
≤
36 V
= Hellschaltung
= Dunkelschaltung
= Light on
= Dark on
Part. 297833 45-5193C
Doc.
Die Serie ML100 ist durch ihr Miniaturgehäuse mit integrierten Vollme-
tall-Gewindebuchsen gekennzeichnet. Alle optischen Varianten sind mit
einer roten Sender LED ausgestattet. Dadurch werden Montage und
Inbetriebnahme optimal vereinfacht. Die Schaltzustände sind durch die
hervorgehobenen LEDs aus allen Richtungen sehr gut sichtbar.
Funktion:
Eine Reflexionslichtschranke enthält Sender und Empfänger in einem
Gehäuse. Das Licht des Senders wird von einem Reflektor zum Empfän
ger zurückgestrahlt. Bei Unterbrechung des Lichtstrahls durch ein Objekt
wird die Schaltfunktion ausgelöst.
Dieser Sensor ist speziell zur Erkennung transparenter Medien und Klar
glas geeignet. Im Kontrastmodus erfolgt eine automatische Nachrege
lung der Schaltschwelle bei Verschmutzung.
Montagehinweise:
Die Sensoren können über Durchgangsbohrungen direkt oder über
einen Haltewinkel bzw. Klemmkörper befestigt werden. Klemmkörper
sind nicht im Lieferumfang enthalten.
Vergewissern Sie sich, dass die Untergrundfläche plan ist, um Gehäuse
verzug beim Festziehen zu vermeiden. Wir empfehlen, die Mutter und
Schraube mit Federscheiben zu sichern, um einer Dejustierung des Sen
sors vorzubeugen.
Beachten Sie bei der Montage die Lage und Sichtbarkeit des Bedien
felds bzw. der LED Anzeigen.
Anschluss:
Schließen Sie das Gerät gemäß Anschlussbild an.
Einstellanweisung:
Wenn Betriebsspannung anliegt, leuchtet die LED grün. Der Sensor ist
automatisch im Zustand maximaler Empfindlichkeit (Auslieferungszu
stand) bzw. im Zustand der letzten Teach In Einstellung.
Montieren Sie einen geeigneten Reflektor gegenüber der Lichtschranke.
Richten Sie den Lichtstrahl auf den Reflektor aus. Die gelbe LED muss
konstant leuchten.
Schalterstellung "T" (Teach-In-Betrieb)
Beim freiem Lichtstrahl (gelbe LED an) den Schalter in Stellung "T" brin
gen und ca. 2 Sekunden warten, bis die gelbe und grüne LED blinken
(2,5 Hz).
Der Sensor kann nun in 2 Kontrastmodi betrieben werden. Drehen Sie
dazu das Potenziometer wahlweise auf Kontraststufe I oder Kontrast
stufe II.
Teach In erfolgreich:
Die grüne und gelbe LED leuchten. Kontrasterkennung ist aktiviert. Das
Gerät ist betriebsbereit. Bringen Sie das zu erfassende Objekt in den
Strahlengang.
Wenn das Objekt erkannt wird, erlischt die gelbe LED.
Teach-In nicht erfolgreich:
Die grüne und gelbe LED blinken schnell abwechselnd (ca. 8 Hz) für ca.
5 Sekunden. Der Sensor geht anschließend in den Zustand mit maxima
ler Empfindlichkeit. Danach die Teach In Prozedur wiederholen.
einigung:
Bei Verschlechterung des Empfangs (Verschmutzung) blinkt die gelbe
LED schnell mit ca. 4 Hz.
Um Verschmutzung und Verschlechterung des Empfangs vorzubeugen,
empfehlen wir, den Lichtaustritt regelmäßig zu reinigen und Verschrau
bungen sowie die Steckverbindungen zu überprüfen.
Der Sensor regelt sich nach dem Reinigen automatisch nach. Das kann
im Modus Klarglaserkennung bis zu 4 Sekunden dauern.
The ML100 series is characterized by its miniature housing with integral,
all metal threaded bushings. All versions are equipped with a visible red
transmitter LED. This greatly simplifies installation and commissioning.
The switching states are easily visible from all directions thanks to the
highly visible LEDs.
Function
A retroreflective sensor contains emitters and receivers integrated in a
single housing. The emitted light is reflected back to the receiver by a ref
lector. When the light beam is interrupted by an object, the switching
function is triggered.
This sensor is specially designed to detect transparent media and clear
glass. In contrast mode, the switching threshold is automatically adjusted
in case of pollution.
Mounting instructions:
The sensors can be secured directly by means of thru holes or using a
mounting bracket or mounting clamp. Mounting brackets are not inclu
ded in the scope of delivery.
Ensure that the surface is level in order to prevent the housing from
becoming distorted when the fittings are tightened. We recommend
securing the nuts and screws using spring disks to prevent the sensor
from becoming misaligned.
Pay careful attention to the position and visibility of the programming
interface or LED displays during mounting.
Connection:
Connect the device as set out in the connection diagram.
Setup instructions:
If operating voltage is present, the LED lights up green. The sensor is
automatically set to maximum sensitivity (default setting) or to the last
teach in setting.
Mount a suitable reflector opposite the sensor.
Direct the light beam at the reflector. The yellow LED must be perman
ently lit.
Switch position "T" (teach-in mode)
When the light beam is clear (yellow LED lit), move the switch into the "T"
position and wait approx. 2 seconds until the yellow and green LEDs
flash (2.5 Hz).
The sensor can now be operated in 2 contrast modes. To do so, turn the
potentiometer either to contrast level I or contrast level II.
Teach in successful:
The green and yellow LEDs light up. Contrast detection is activated. The
device is ready for operation. Place the object to be detected into the
beam.
When the object is detected, the yellow LED goes out.
Teach-in not successful:
The green and yellow LEDs flash alternately at rapid intervals
(approx. 8 Hz) for approx. 5 seconds. The sensor is then set to maximum
sensitivity. Then repeat the teach in process again.
Cleaning:
In the event of impaired reception (soiling), the yellow LED flashes
rapidly with a frequency of approx. 4 Hz.
To prevent soiling and impaired reception, we recommend cleaning the
optical face and checking the screw joints and connections at regular
intervals.
The sensor adjusts itself automatically after cleaning. This process can
take up to 4 seconds in clear glass detection mode.
Um eine fehlerfreie Funktionalität bei transparenten Objek
ten zu gewährleisten, empfehlen wir, dass Sie Sender und
Empfänger grundsätzlich in einer vertikalen Anordnung in
stallieren, siehe Abbildung.
To guarantee an accurate functionality while using transpar
ent objects, we recommend to install emitter and receiver in
a vertical alignment, cf. figure.
Bestimmungsgemäße Verwendung
Intended use
200
150
100
50
0
-50
-100
-150
-200 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
X [m]
Y [mm]
Charakteristische Ansprechkurve
Courbe de response caractéristique
Curve di risposta caratteristica
Characteristic response curve
Curva de respuesta característica
Möglicher Abstand (Versatz) zwischen
optischer Achse und Referenzobjekt.
Permissible distance (offset) between
optical axis and reference target.
Ecart possible entre l'axe optique et la
cible de référence.
Desplazamiento entre el eje óptico y
objeto de referencia.
Distanza possibile (sfalsato) tra l'asse
ottico e l'ogetto di riferimento.
X
Y
H85-2
H50
H33
MH20
MH33
Reflektortyp/Reflector type/Type de réflecteur/Type de réflecteur
Abstand/Distance/Distance/Distance
X [m]
REF-H85-2
REF-H50
REF-H60 x 50
REF-MH20
REF-H33
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
1.2 m
1.8 m
2.5 m
3.5 m
0.05 m
1.7 m0.05 m
0.05 m
0.05 m
0.05 m
Reflektorabhängige Betriebsreichweite, typisch
Reflector-dependent effective operating distances, typical
Distances types de fonctionnement effectives en fonction du réflecteur
Distancias operativas eficaces dependientes del reflector, típicas
Frontal view
Z
XX
Frontal view
Richtig Falsch
E
S
E
S
E
S
Empfänger
Sender
Bewegungsrichtung des Objektes
E
SE
S
Frontal view
Z
XX
Frontal view
Right Wrong
R
E
R
E
R
E
Receiver
Emitter
R
ER
E

Other Pepperl+Fuchs Accessories manuals

Pepperl+Fuchs 2-D LiDAR R2000 Series Reference guide

Pepperl+Fuchs

Pepperl+Fuchs 2-D LiDAR R2000 Series Reference guide

Pepperl+Fuchs SmartRunner Detector User manual

Pepperl+Fuchs

Pepperl+Fuchs SmartRunner Detector User manual

Pepperl+Fuchs SmartRunner 3-D ToF User manual

Pepperl+Fuchs

Pepperl+Fuchs SmartRunner 3-D ToF User manual

Pepperl+Fuchs VL18-54-MS/32/40a/82b/118 User manual

Pepperl+Fuchs

Pepperl+Fuchs VL18-54-MS/32/40a/82b/118 User manual

Pepperl+Fuchs UC500-30GM-2EP-IO-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC500-30GM-2EP-IO-V15 User manual

Pepperl+Fuchs UC2000-L2-E6-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC2000-L2-E6-V15 User manual

Pepperl+Fuchs IPT FP Series User manual

Pepperl+Fuchs

Pepperl+Fuchs IPT FP Series User manual

Pepperl+Fuchs PHA-F200-B6-V15B Series User manual

Pepperl+Fuchs

Pepperl+Fuchs PHA-F200-B6-V15B Series User manual

Pepperl+Fuchs NCB20-L2-N0-V1 User manual

Pepperl+Fuchs

Pepperl+Fuchs NCB20-L2-N0-V1 User manual

Pepperl+Fuchs NJ10-30GM50-E2-V1-3G-3D User manual

Pepperl+Fuchs

Pepperl+Fuchs NJ10-30GM50-E2-V1-3G-3D User manual

Pepperl+Fuchs UC L2M Series User manual

Pepperl+Fuchs

Pepperl+Fuchs UC L2M Series User manual

Pepperl+Fuchs NBN4-12GS40-Z4L-V1-3G-3D User manual

Pepperl+Fuchs

Pepperl+Fuchs NBN4-12GS40-Z4L-V1-3G-3D User manual

Pepperl+Fuchs UC2000-30GM-2EP-IO-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC2000-30GM-2EP-IO-V15 User manual

Pepperl+Fuchs NCN40-L2-N0-V1 User manual

Pepperl+Fuchs

Pepperl+Fuchs NCN40-L2-N0-V1 User manual

Pepperl+Fuchs UC-18GS Series Installation and operation manual

Pepperl+Fuchs

Pepperl+Fuchs UC-18GS Series Installation and operation manual

Pepperl+Fuchs SIL VIM8 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs SIL VIM8 Series User manual

Pepperl+Fuchs KFU8-DW-1.D User manual

Pepperl+Fuchs

Pepperl+Fuchs KFU8-DW-1.D User manual

Pepperl+Fuchs UC4000-L2-E4-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC4000-L2-E4-V15 User manual

Pepperl+Fuchs INY360D-F99-2I2E2-V17 User manual

Pepperl+Fuchs

Pepperl+Fuchs INY360D-F99-2I2E2-V17 User manual

Pepperl+Fuchs OPC User manual

Pepperl+Fuchs

Pepperl+Fuchs OPC User manual

Pepperl+Fuchs GLV18-55-G/73/120 User manual

Pepperl+Fuchs

Pepperl+Fuchs GLV18-55-G/73/120 User manual

Pepperl+Fuchs UC4000-L2-E5-V15-Y70120089 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC4000-L2-E5-V15-Y70120089 User manual

Pepperl+Fuchs INX DH-F199-B30 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs INX DH-F199-B30 Series User manual

Pepperl+Fuchs IDM-Z1-X64-B-J1-BT-N0 User manual

Pepperl+Fuchs

Pepperl+Fuchs IDM-Z1-X64-B-J1-BT-N0 User manual

Popular Accessories manuals by other brands

Security Point ZOOM-Z2E Instructions and warnings

Security Point

Security Point ZOOM-Z2E Instructions and warnings

SICK LBR operating instructions

SICK

SICK LBR operating instructions

Panasonic FX-100 Series instruction manual

Panasonic

Panasonic FX-100 Series instruction manual

DoKaSch Opticooler RAP Operation manual

DoKaSch

DoKaSch Opticooler RAP Operation manual

MICRO-EPSILON optoNCDT 1220 operating instructions

MICRO-EPSILON

MICRO-EPSILON optoNCDT 1220 operating instructions

PCB Piezotronics 080A121 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 080A121 Installation and operating manual

Attero Tech VoiceBox 4I/OP user manual

Attero Tech

Attero Tech VoiceBox 4I/OP user manual

INSTEON 2845 22 Series owner's manual

INSTEON

INSTEON 2845 22 Series owner's manual

PPM Ultra Installation, operation and maintenance manual

PPM

PPM Ultra Installation, operation and maintenance manual

Makita CW002G instruction manual

Makita

Makita CW002G instruction manual

Gared Sports Mini-EZ Installation, operation and maintenance instructions

Gared Sports

Gared Sports Mini-EZ Installation, operation and maintenance instructions

X4-Life ECO instruction manual

X4-Life

X4-Life ECO instruction manual

STEINEL PROFESSIONAL sensIQ S Information

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL sensIQ S Information

Smanos WI-20 user manual

Smanos

Smanos WI-20 user manual

Edirol UA-1A owner's manual

Edirol

Edirol UA-1A owner's manual

Banner iVu Plus BCR quick start guide

Banner

Banner iVu Plus BCR quick start guide

Aurora AU-A1ZBDSS quick start guide

Aurora

Aurora AU-A1ZBDSS quick start guide

Amped Avid 5 user manual

Amped

Amped Avid 5 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.