manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pyronix
  6. •
  7. Security System
  8. •
  9. Pyronix Matrix 6/816 User manual

Pyronix Matrix 6/816 User manual

Other manuals for Matrix 6/816

1

Other Pyronix Security System manuals

Pyronix OCTAGON II User manual

Pyronix

Pyronix OCTAGON II User manual

Pyronix Enforcer 32WE User manual

Pyronix

Pyronix Enforcer 32WE User manual

Pyronix STERLING 10 User manual

Pyronix

Pyronix STERLING 10 User manual

Pyronix Enforcer 32WE User manual

Pyronix

Pyronix Enforcer 32WE User manual

Pyronix Paragon Plus User manual

Pyronix

Pyronix Paragon Plus User manual

Pyronix PCX 46 User manual

Pyronix

Pyronix PCX 46 User manual

Pyronix ENFORCER RINS1706-1 Service manual

Pyronix

Pyronix ENFORCER RINS1706-1 Service manual

Pyronix HOMECONTROLHUB User manual

Pyronix

Pyronix HOMECONTROLHUB User manual

Pyronix PCX 256 User manual

Pyronix

Pyronix PCX 256 User manual

Pyronix XD15TT User manual

Pyronix

Pyronix XD15TT User manual

Pyronix Enforcer 32WE User manual

Pyronix

Pyronix Enforcer 32WE User manual

Pyronix Matrix 424 User manual

Pyronix

Pyronix Matrix 424 User manual

Pyronix Wireless Alarm system User manual

Pyronix

Pyronix Wireless Alarm system User manual

Pyronix Enforcer Setup guide

Pyronix

Pyronix Enforcer Setup guide

Pyronix RINS1902-2 User manual

Pyronix

Pyronix RINS1902-2 User manual

Pyronix PCX-12 User manual

Pyronix

Pyronix PCX-12 User manual

Pyronix ENFORCER V11 Service manual

Pyronix

Pyronix ENFORCER V11 Service manual

Pyronix PCX 78 User manual

Pyronix

Pyronix PCX 78 User manual

Pyronix XDL12TT-AM User manual

Pyronix

Pyronix XDL12TT-AM User manual

Pyronix Enforcer 32-W User manual

Pyronix

Pyronix Enforcer 32-W User manual

Pyronix PARAGON E User manual

Pyronix

Pyronix PARAGON E User manual

Pyronix Enforcer User manual

Pyronix

Pyronix Enforcer User manual

Pyronix Enforcer 32WE User manual

Pyronix

Pyronix Enforcer 32WE User manual

Pyronix PCX 256 User manual

Pyronix

Pyronix PCX 256 User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Matrix 6 / 816 Getting Started
RINS700-2 Page 1
TIPRING R-1 T-117V~ + BAT - + SIREN - NC1 C1 NO1 PGM2PGM3PGM4 PGM5 PGM6 + AUX - K+ KD K- Z1 COM Z2 Z3 COM Z4 +AUX - Z5 COM Z6 Z7 COM Z8
NBUSJY
816
2 AMP AC FUSE
5 AMP BATTERY FUSE
1A AUX FUSE
1A KEYPAD FUSE
RS-232
NVM RESET
Transforme r
VV
230 /17
To mains
V
~ 230
~17V
Battery 12V
To analogue
telephone network
To o th e r
telephone equipment
RKP No1
external
ombined
sounder
& strobe
BELLE
с
B- B+ STB BT TFBA
K+ KD K- KT KTR
4K7 4K7
4K7
4K7
Zone 1
Magnetic Contact
Zone 2
PIR
Detector
+AUX-
4К7
4K7
4 Wire Fire
Detector
Customer Support
0870 122 3360 (UK Only)
Calls are charged at national rate
Email: customer.support@pyronix.com
Terminal
Block
Link out unused
zones with 4K7Ω
resistors.
MATRIX 6 / 816 GETTING STARTED
Please note that the terminals on the Matrix
816 are the same as the Matrix 6
Customer Support
+44(0)845 6434 999 (local rate) or
+44(0)1709 535 225
Email:
customer.suppor[email protected]
Matrix 6 / 816 Getting Started
Page 2 RINS700-2
Matrix 6 / 816 programming
Entering Engineer Mode
Enter () where:
() is the engineer code (default
= 9999).
Changing Engineer Code
Enter .
Enter new engineer code ().
If four- or five-digit code, press .
An acceptance tone will be heard.
Re-enter new engineer code ().
If four- or five-digit code, press .
An acceptance tone will be heard.
Setting Bell Time
Enter .
Enter time in minutes ( to , default =
20) followed by .
An acceptance tone will be heard.
Setting Entry Time
Enter .
Enter time in seconds ( to , default
= 30) followed by .
An acceptance tone will be heard.
Setting Exit Time
Enter .
Enter time in seconds ( to , default =
30) followed by .
An acceptance tone will be heard.
Programming Zones
Enter:
Arm Mode A:
 -  Zones 1 - 8
 -  Zones 9 – 16
Arm Mode B:
 -  Zones 1 - 8
 -  Zones 9 - 16
Arm Mode C:
 -  Zones 1 - 8
 -  Zones 9 – 16
Arm Mode D:
 -  Zones 1 - 8
 -  Zones 9 - 16
Enter the zone type you require as a 2-digit number:
00 = Entry Exit 07 = Patrol
01 = Access/Interior 08 = Shunt Keypad
02 = Instant 09 = Tamper
03 = Omitted (Bypass) 10 = Latch Keyswitch
04 = Fire 11 = Momentary Keyswitch
05 = Panic 12 = Unused
06 = 24 Hour
Press to accept the zone type.
Entering Account Code
Enter .
Enter the 4-digit account code followed by .
Entering Telephone Numbers
Enter:
 – Telephone 1
 – Telephone 2
 – Telephone 3
Enter the telephone number. Use the following key
presses to enter special characters:
 = *, will be displayed a 
 = #, will be displayed as 
 = 2 second pause, will be displayed as 
= Delete current number and exit function
Exiting Engineer Mode
Enter 