The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F156
Model F1FR56
Intermediate Level
Sprinklers
Bulletin 031 July 2020
Bulletin 031 July 2020
Features
1. Upright and pendent installations.
2. Available as either a standard response Model F156 or
quick response Model F1FR56.
3. ½” (15mm) orifice with a ½” NPT (R½).
4. Maximum working pressure of 250 PSI (cULus).
For Model F1/F1FR 3/4” K 8.0 (115) Sprinkler Types
refer to Bulletin 170 for technical specifications and
approvals.
Approval Organizations
1. Listed by Underwriters Laboratories, Inc. and
Certified for Canada (cULus)
2. Certified by FM Approvals
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Product Description
The Reliable Models F156 and F1FR56 Intermediate Level
Sprinklers include shields which protect the glass bulb from
water spray impingement caused by sprinklers located at a
higher elevation.
Typical applications are for storage racks which require
multi–level sprinklers and beneath open grid catwalks.
Application
Model F156 and F1FR56 Intermediate Level sprinklers are
used in fixed fire protection systems: Wet, Dry, Deluge or Pre-
action. Care must be exercised that the orifice size, tempera-
ture rating, deflector style and sprinkler type are in accordance
with the latest published standards of the National Fire Protec-
tion Association or the Authority Having Jurisdiction.
Installation
Model F156 sprinklers are standard response sprinklers
and Model F1FR56 are quick response sprinklers. Both types
are intended for installation as specified in NFPA 13. Upright
sprinklers must be installed with the Model D Sprinkler Wrench
specifically designed by Reliable for use with these sprinklers,
and pendent sprinklers must be installed with the Model GFR2
Sprinkler Wrench specifically designed by Reliable for use
with these sprinklers.
Model F156
Upright Intermediate
Model F1FR56
Pendent Intermediate
Model F1FR56
Upright Intermediate
Model F156
Pendent Intermediate
Glass bulb sprinklers have orange covers to protect the bulb
during the installation process. REMOVE THIS PROTECTION
ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY
TESTED. Model D and GFR2 wrenches are designed to install
sprinklers when covers are in place.
Maintenance
The Models F156 and F1FR56 Sprinklers should be inspect-
ed and the sprinkler system maintained in accordance with
NFPA 25. Do not clean sprinklers with soap and water, am-
monia or any other cleaning fluid. Remove dust by using a soft
brush or gentle vacuuming. Remove any sprinkler which has
been painted (other than factory applied) or damaged in any
way. A stock of spare sprinklers should be maintained to allow
quick replacement of damaged or operated sprinklers. Prior
to installation, sprinklers should be maintained in the original
cartons and packaging until used to minimize the potential
for damage to sprinklers that would cause improper or non-
operation.
2.
Model F1FR56 Quick Response Upright & Pendent Intermediate Level Sprinklers
Model F156 Standard Response Upright & Pendent Intermediate Level Sprinklers
Installation Data:
Sprinkler Type Nominal
Orifice
Thread
Size
“K” Factor Max. Working
Pressure
Sprinkler
Identification
Number (SIN)
Sprinkler
Height Approvals
US Metric
Pendent ½” (15mm) ½” NPT (R ½) 5.6 80 250 PSI
(cULus)
175 psi (FM)
RA1414 2.25” 1,2
Upright ½” (15mm) ½” NPT (R ½) 5.6 80 RA3195 2.25” 1,2
Model F156 and F1FR56 Intermediate Level Sprinklers
Installation Data:
Sprinkler
Type
Nominal
Orifice
Thread
Size
“K” Factor Max. Working
Pressure
Sprinkler
Identification
Number (SIN)
Sprinkler
Height Approvals
US Metric
Pendent ½” (15mm) ½” NPT (R ½) 5.6 80 250 PSI
(cULus)
175 psi (FM)
RA1314 2.25” 1,2
Upright ½” (15mm) ½” NPT (R ½) 5.6 80 RA1325 2.25” 1,2
Fig. 1
Temperature Ratings For F1FR56:
Classification Sprinkler Temperature Bulb Color
°F °C
Ordinary 135 57 Orange
Ordinary 155 68 Red
Intermediate 175 79 Yellow
Intermediate 200 93 Green
High 286 141 Blue
Temperature Ratings For F156:
Classification Sprinkler Temperature Bulb Color
°F °C
Ordinary 135 57 Orange
Ordinary 155 68 Red
Intermediate 175 79 Yellow
Intermediate 200 93 Green
High 286 141 Blue
Extra High 360 182 Mauve
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Temperature Rating
5. Sprinkler Finish
Installation Wrenches
Upright — Model D Sprinkler Wrench
Pendent — Model GFR2 Sprinkler Wrench
Pendent Sprinkler Finishes (1)
Standard Finish
Bronze
Special Application Finishes
Electroless Nickel PTFE(4)(5)
Bright Chrome
Chrome Dull
Lead Plated(2)(4)
Wax Coated(2)(3)(4)
Wax Over Lead(2)(3)(4)
(1) Other colors and finishes are available. Consult factory for details.
(2) Model F156 Standard Response only.
(3) 55°F (68°C), 175°F (79°C), 200°F (93°C) and 286°F (141°C) tem-
perature ratings only.
(4) Only the sprinkler is wax coated, lead or Electroless Nickel PTFE
plated. The shield finish remains galvanized steel.
(5) cULus listed Corrosion Resistant.
Upright Sprinkler Finishes
Standard Finish
Bronze
Special Application Finishes
White Polyester
Note: Paint or any other coating applied over the factory finish will void
approvals and warranties.
Shields
Galvanized Steel
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by
Recycled
Paper
Revision lines indicate updated or new data.
EG. Printed in U.S.A. 07/20 P/N 9999970391
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years.

Other manuals for F156 Series

8

This manual suits for next models

2

Other Reliable Irrigation System manuals

Reliable RFS42 Manual

Reliable

Reliable RFS42 Manual

Reliable RFC56 User manual

Reliable

Reliable RFC56 User manual

Reliable DDX PrePaK D Maintenance manual

Reliable

Reliable DDX PrePaK D Maintenance manual

Reliable F4FR User manual

Reliable

Reliable F4FR User manual

Reliable DH56 HSW-PL User manual

Reliable

Reliable DH56 HSW-PL User manual

Reliable F156 Series User manual

Reliable

Reliable F156 Series User manual

Reliable DH80 Dry User manual

Reliable

Reliable DH80 Dry User manual

Reliable G6-80 User manual

Reliable

Reliable G6-80 User manual

Reliable Pantman F1 User manual

Reliable

Reliable Pantman F1 User manual

Reliable J112SS Series Manual

Reliable

Reliable J112SS Series Manual

Reliable Concealer G4A User manual

Reliable

Reliable Concealer G4A User manual

Reliable G5-56 300 User manual

Reliable

Reliable G5-56 300 User manual

Reliable DH80 User manual

Reliable

Reliable DH80 User manual

Reliable XL Manual

Reliable

Reliable XL Manual

Reliable F1S5-FSLO User manual

Reliable

Reliable F1S5-FSLO User manual

Reliable LT56 Series User manual

Reliable

Reliable LT56 Series User manual

Reliable F1FR User manual

Reliable

Reliable F1FR User manual

Reliable F1-SS Series User manual

Reliable

Reliable F1-SS Series User manual

Reliable F1FR28 Series User manual

Reliable

Reliable F1FR28 Series User manual

Reliable F1 LO Manual

Reliable

Reliable F1 LO Manual

Reliable G4 User manual

Reliable

Reliable G4 User manual

Reliable F3QR56 Dry Manual

Reliable

Reliable F3QR56 Dry Manual

Reliable F1FR-SS Series Manual

Reliable

Reliable F1FR-SS Series Manual

Reliable RFC43 User manual

Reliable

Reliable RFC43 User manual

Popular Irrigation System manuals by other brands

Tyco Fire Protection Products PROTECTOSPRAY EA-1 manual

Tyco Fire Protection Products

Tyco Fire Protection Products PROTECTOSPRAY EA-1 manual

Solem WooBee Quick installation guide

Solem

Solem WooBee Quick installation guide

Sime KLICKER Translation from the original instructions

Sime

Sime KLICKER Translation from the original instructions

Tyco Fire Product CENTRAL TFP1 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL TFP1 instruction manual

Havahart 5266 owner's manual

Havahart

Havahart 5266 owner's manual

Base Line BaseStation 3200 manual

Base Line

Base Line BaseStation 3200 manual

Base Line BaseStation 3200 manual

Base Line

Base Line BaseStation 3200 manual

K-Rain Sure Throw ST-IS45 instruction sheet

K-Rain

K-Rain Sure Throw ST-IS45 instruction sheet

GEM F892 manual

GEM

GEM F892 manual

Senju Sprinkler ZN-QR manual

Senju Sprinkler

Senju Sprinkler ZN-QR manual

Tyco EC-5 Series quick start guide

Tyco

Tyco EC-5 Series quick start guide

Tyco DS-1 Series manual

Tyco

Tyco DS-1 Series manual

Perrot ZN23-3D Maintenance and operating instructions

Perrot

Perrot ZN23-3D Maintenance and operating instructions

Viking 10284 Technical data

Viking

Viking 10284 Technical data

Toro TS170 operating manual

Toro

Toro TS170 operating manual

Rain Bird isa 300/400 Installation, programming, and operation guide

Rain Bird

Rain Bird isa 300/400 Installation, programming, and operation guide

Cellfast 52-303 user manual

Cellfast

Cellfast 52-303 user manual

Tyco RFII Series quick start guide

Tyco

Tyco RFII Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.