manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Reliable
  6. •
  7. Irrigation System
  8. •
  9. Reliable Pantman F1 User manual

Reliable Pantman F1 User manual

Other manuals for Pantman F1

5

This manual suits for next models

1

Other Reliable Irrigation System manuals

Reliable HL22 User manual

Reliable

Reliable HL22 User manual

Reliable Pantman F1 User manual

Reliable

Reliable Pantman F1 User manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable RFC30 LL User manual

Reliable

Reliable RFC30 LL User manual

Reliable XL Manual

Reliable

Reliable XL Manual

Reliable G5 Series User manual

Reliable

Reliable G5 Series User manual

Reliable XL Commercial User manual

Reliable

Reliable XL Commercial User manual

Reliable F1 LO User manual

Reliable

Reliable F1 LO User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable G4 User manual

Reliable

Reliable G4 User manual

Reliable F1FR-300 User manual

Reliable

Reliable F1FR-300 User manual

Reliable DH56 HSW User manual

Reliable

Reliable DH56 HSW User manual

Reliable The Non-Ferrous Concealer F4FR-NF User manual

Reliable

Reliable The Non-Ferrous Concealer F4FR-NF User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F1FR56 Manual

Reliable

Reliable F1FR56 Manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable RFC43 User manual

Reliable

Reliable RFC43 User manual

Reliable GFR User manual

Reliable

Reliable GFR User manual

Reliable F1-SS Series User manual

Reliable

Reliable F1-SS Series User manual

Reliable J112SS Series Manual

Reliable

Reliable J112SS Series Manual

Reliable G6-80 User manual

Reliable

Reliable G6-80 User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable JL-14 User manual

Reliable

Reliable JL-14 User manual

Reliable F1FR-FS56 User manual

Reliable

Reliable F1FR-FS56 User manual

Popular Irrigation System manuals by other brands

Tyco TY-B Series manual

Tyco

Tyco TY-B Series manual

Toro ZSERIES 570Z brochure

Toro

Toro ZSERIES 570Z brochure

OpenSprinkler OSPi user manual

OpenSprinkler

OpenSprinkler OSPi user manual

EINHELL GE-WW 5537 E Original operating instructions

EINHELL

EINHELL GE-WW 5537 E Original operating instructions

Hunter Institutional Series instructions

Hunter

Hunter Institutional Series instructions

Cellfast 52-305 user manual

Cellfast

Cellfast 52-305 user manual

Tyco Fire Product Star Galaxy SGQR instruction manual

Tyco Fire Product

Tyco Fire Product Star Galaxy SGQR instruction manual

Tyco Fire Product CENTRAL A instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL A instruction manual

Oral Care Technologies Hydro Floss Instructions for use

Oral Care Technologies

Oral Care Technologies Hydro Floss Instructions for use

Tyco Fire Product Gem F892 instruction manual

Tyco Fire Product

Tyco Fire Product Gem F892 instruction manual

Irrigation-Mart KIT-GK100-RV-B quick start guide

Irrigation-Mart

Irrigation-Mart KIT-GK100-RV-B quick start guide

Tyco CC3 manual

Tyco

Tyco CC3 manual

Valley Bender160 owner's manual

Valley

Valley Bender160 owner's manual

Toro 730 Series Installation and service instructions

Toro

Toro 730 Series Installation and service instructions

Eden 97063-EDAMZ quick start guide

Eden

Eden 97063-EDAMZ quick start guide

Netafim NETBEAT user manual

Netafim

Netafim NETBEAT user manual

Tyco Fire Product CENTRAL ELO-231 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL ELO-231 instruction manual

Johnson Controls tyco ESFR-17 manual

Johnson Controls

Johnson Controls tyco ESFR-17 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1
Model F1FR
Intermediate Level
Sprinklers
Bulletin 170 Rev. E
Bulletin 170 Rev. E
Features
Upright and pendent installations.
Available as either a standard response
Model F1 or quick response Model F1FR.
Temperature ratings of 135°F (57°C), 155°F
(68°C), 175°F (79°C), 200°F (93°C) and
286°F (141°C) for Models F1 and F1FR; the
Model F1 is also available in additional rating
of 360°F (182°C).
17/32” (20mm) orifice with ¾” NPT (R¾).
For Model F156/F1FR56 ½” K 5.6 (80) Sprinkler Types
refer to Bulletin 031 for technical specifications and
approvals.
Listings & Approvals
Listed by Underwriters Laboratories, Inc. (UL)
Listed by Underwriters’ Laboratories of Canada (ULC)
Certified by FM Approvals
NYC MEA No. 258-93-E
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Product Description
The Reliable Models F1 and F1FR Intermediate Level
Sprinklers include shields which protect the glass bulb from
water spray impingement caused by sprinklers located at a
higher elevation.
Typical applications are for storage racks which require
multi–level sprinklers and beneath open grid catwalks.
Application
Model F1 and F1FR Intermediate Level sprinklers are used
in fixed fire protection systems: Wet, Dry, Deluge or Preaction.
Care must be exercised that the orifice size, temperature rat-
ing, deflector style and sprinkler type are in accordance with
the latest published standards of the National Fire Protection
Association or the Authority Having Jurisdiction.
Installation
Model F1 sprinklers are standard response sprinklers and
Model F1FR are quick response sprinklers. Both types are
intended for installation as specified in NFPA 13. Upright
sprinklers must be installed with the Model D Sprinkler
Wrench specifically designed by Reliable for use with these
sprinklers, and pendent sprinklers must be installed with the
1.
2.
3.
4.
1.
2.
3.
4.
Model F1
Pendent Intermediate
Model F1
Upright Intermediate
Model GFR1 Sprinkler Wrench specifically designed by Reli-
able for use with these sprinklers.
Glass bulb sprinklers have orange covers to protect the
bulb during the installation process. REMOVE THIS PRO-
TECTION ONLY AFTER THE SYSTEM HAS BEEN HYDRO-
STATICALLY TESTED AND, WHEN APPLICABLE, THE ES-
CUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches
are designed to install sprinklers when covers are in place.
Maintenance
The Models F1 and F1FR Sprinklers should be inspected
quarterly and the sprinkler system maintained in accor-
dance with NFPA 25. Do not clean sprinklers with soap and
water, ammonia or any other cleaning fluid. Remove dust by
using a soft brush or gentle vacuuming. Remove any sprin-
kler which has been painted (other than factory applied) or
damaged in any way. A stock of spare sprinklers should be
maintained to allow quick replacement of damaged or op-
erated sprinklers. Prior to installation, sprinklers should be
maintained in the original cartons and packaging until used
to minimize the potential for damage to sprinklers that would
cause improper or non-operation.
Model F1FR
Upright Intermediate Model F1FR
Pendent Intermediate
2.
Model F1FR Quick Response Upright & Pendent Intermediate Level Sprinklers
Installation Data:
Sprinkler
Type
Nominal
Orifice Thread Size
“K” Factor Sprinkler
Identification
Number (SIN)
Shield Part
Number
Sprinkler
Height Approvals
US Metric
Pendent 17/32” (20mm) ¾” NPT (R ¾) 8.00 115.30 R3612 88701412 2.3” 1,2,3,4
Upright 17/32” (20mm) ¾” NPT (R ¾) 8.00 115.30 R7092 88701410 2.3” 1,2,3,4
Model F1 Standard Response Upright & Pendent Intermediate Level Sprinklers
Installation Data:
Sprinkler
Type
Nominal
Orifice Thread Size
“K” Factor Sprinkler
Identification
Number (SIN)
Shield Part
Number
Sprinkler
Height Approvals
US Metric
Pendent 17/32” (20mm) ¾” NPT (R
¾) 8.00 115.30 R1712 88701412 2.3” 1,2,3,4
Upright 17/32” (20mm) ¾” NPT (R
¾) 8.00 115.30 R7022 88701410 2.3” 1,2,3,4
Models F1 and F1FR Upright Intermediate Level Sprinklers
Models F1 and F1FR Pendent Intermediate Level Sprinkler
3.
Temperature Ratings For F1FR:
Classification Sprinkler Temperature Bulb Color
°C °F
Ordinary 57 135 Orange
Ordinary 68 155 Red
Intermediate 79 175 Yellow
Intermediate 93 200 Green
High 141 286 Blue
Temperature Ratings For F1:
Classification Sprinkler Temperature Bulb Color
°C °F
Ordinary 57 135 Orange
Ordinary 68 155 Red
Intermediate 79 175 Yellow
Intermediate 93 200 Green
High 141 286 Blue
Extra High 182 360 Mauve
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Orifice Size
Temperature Rating
Sprinkler Finish
Installation Wrenches
Upright — Model D Sprinkler Wrench
Pendent — Model GFR2 Sprinkler Wrench
Finishes (1)
Standard Finishes
Bronze
Special Application Finishes
Bright Chrome
Satin Chrome
Lead Plated (2) (4)
Wax Coated (2) (3) (4)
Wax Coated Over Lead Plated (2) (3) (4)
(1) Other colors and finishes are available. Consult factory for details.
(2) Model F1 Standard Response only.
(3) 155°F (68°C) to 200°F (93°C) ratings only.
(4) Only the sprinkler is lead plated or wax coated. The shield finish
remains galvanized zinc.
Shields
Galvanized Zinc
1.
2.
3.
4.
5.
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by
Recycled
Paper
Revision lines indicate updated or new data.
EG. Printed in U.S.A 08/10 P/N 9999970034
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Automatic sprinklers
Flush automatic sprinklers
Recessed automatic sprinklers
Concealed automatic sprinklers
Adjustable automatic sprinklers
Dry automatic sprinklers
Intermediate level sprinklers
Open sprinklers
Spray nozzles
Alarm valves
Retarding chambers
Dry pipe valves
Accelerators for dry pipe valves
Mechanical sprinkler alarms
Electrical sprinkler alarm switches
Water flow detectors
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Deluge valves
Detector check valves
Check valves
Electrical system
Sprinkler emergency cabinets
Sprinkler wrenches
Sprinkler escutcheons and guards
Inspectors test connections
Sight drains
Ball drips and drum drips
Control valve seals
Air maintenance devices
Air compressors
Pressure gaugesIdentification signs
Fire department connection
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Reliable...For Complete Protection