47-0028-08 • RevB • 2017-02-03
Tech Support Line (877) 260-5578
www.ResolutionProducts.com
WARRANTY
Resolution Products, Inc. will replace products that are defective in
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE318
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Products, Inc. could void the user’s authority to operate this
equipment.
FCC ID: U5X-RE318
CE DECLARATION OF CONFORMITY
Hereby, Resolution Products, Inc. declares that this RE618-CE is
in compliance with the essential requirements and other relevant
provisions of directive 1999/5/EC.
(This declaration can be translated to other languages via a myriad
of translation tools found on the Internet.)
Pro Tips
The cover can be removed without removing the wall clip.
Both titanium probes must be in the same puddle for the Trident to detect water.
Tamper detection depends on how the Trident is installed.
• Trident secured to wall: Tamper is indicated when lifted off the clip.
• Trident NOT secured to wall: Tamper is indicated when the cover is removed.
When changing the batteries replace both with new batteries.
Physical
Housing Dimensions
Weight with Batteries
Mounting Fastener
2.43 x 2.48 x 1.17 inches (6.2 x 6.3 x 3.0 cm)
1.34 ounces (38 grams)
#6 screw (not provided)
Environmental
Operating Temperature
Maximum Humidity
Water Resistance
32°F to 120°F (0°C to 49°C)
85% non-condensing relative humidity
IP67 rated (waterproof for over 30 minutes at 1 meter depth)
Frequency
Replacement Batteries
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Temperature Accuracy
433.92 MHz
Two Panasonic CR2032
10 years
3.0 VDC (Nominal) 2.3 VDC (Low)
20 mA (Maximum) 0.5 uA (Quiescent)
Cover Tamper, Wall Tamper, Low Battery, Supervision
+/- 2°C
RE618
RE618-CE
FCC, IC, RCM
EN60950-1, EN300 220, EN301 489