7 Start-up – Settings . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.1 Determining the fail-safe position . . . . . . . . . . . . . . . . . . . 51
7.2 Setting the volume restriction Q . . . . . . . . . . . . . . . . . . . . 52
7.3 Adapting the display . . . . . . . . . . . . . . . . . . . . . . . . . 52
7.4 Limiting the signal pressure . . . . . . . . . . . . . . . . . . . . . . 53
7.5 Checking the operating range of the positioner . . . . . . . . . . . . . 53
7.6 Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.6.1 MAX – Initialization based on maximum range . . . . . . . . . . . . 56
7.6.2 NOM – Initialization based on nominal range . . . . . . . . . . . . . 57
7.6.3 MAN – Initialization based on a manually selected range . . . . . . . 58
7.6.4 SUb substitute calibration . . . . . . . . . . . . . . . . . . . . . . . 59
7.7 Zero calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
7.8 Performing settings for open/close valves . . . . . . . . . . . . . . . 63
7.9 Reset to default values . . . . . . . . . . . . . . . . . . . . . . . . . 65
8 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
8.1 Enabling and selecting parameters . . . . . . . . . . . . . . . . . . 66
8.2 Operating modes . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
8.2.1 Automatic and manual modes. . . . . . . . . . . . . . . . . . . . . 67
8.2.2 Fail-safe position (SAFE). . . . . . . . . . . . . . . . . . . . . . . . 68
8.3 Malfunction/maintenance alarm . . . . . . . . . . . . . . . . . . . . 68
8.3.1 Confirming error messages . . . . . . . . . . . . . . . . . . . . . . 69
9 Adjusting the limit switch . . . . . . . . . . . . . . . . . . . . . . . 70
9.1 Retrofitting an inductive limit switch . . . . . . . . . . . . . . . . . . 72
10 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
11 Servicing explosion-protected devices . . . . . . . . . . . . . . . . . 73
12 Code list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
13 Settings in TROVIS-VIEW software. . . . . . . . . . . . . . . . . . . 99
13.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
13.1.1 System requirements . . . . . . . . . . . . . . . . . . . . . . . . . 99
13.2 Installing TROVIS-VIEW software . . . . . . . . . . . . . . . . . . . 100
13.3 Starting TROVIS-VIEW and performing basic settings . . . . . . . . . 101
13.4 Data transmission . . . . . . . . . . . . . . . . . . . . . . . . . . 103
13.4.1 Offline operation (indirect data transmission) . . . . . . . . . . . . . 104
13.4.2 Online operation (direct data transmission) . . . . . . . . . . . . . . 104
13.4.3 Setting parameters. . . . . . . . . . . . . . . . . . . . . . . . . . 105
13.5 Initializing the positioner . . . . . . . . . . . . . . . . . . . . . . . 107
13.6 Status classification . . . . . . . . . . . . . . . . . . . . . . . . . 109